| Sl. No. | Item Description |
| 1 | Note:-Please refer schedule \"A\" notesbefore quoting the tender.(ii) Amount of Schedule of credit shall be deducated off line by the department. |
| 2 | GENERAL SUMMARY |
| 3 | Lump sum price worked out by the contractor for BUILDING WORK as listed in Schedule ‘A’ Part-I (Ref prepriced schedule attached separately). |
| 4 | Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’Part- II (Ref prepriced schedule attached seperately) |
| 5 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’Part- III (Ref prepriced schedule attached seperately) |
| 6 | Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’Part- IV (Ref prepriced schedule attached seperately) |
| 7 | Lump sum price worked out by the contractor for EXTERNAL ELETRICWORKS as listed in Schedule ‘A’Part- V (Ref prepriced schedule attached seperately) |
| 8 | Lump sum price worked out by the contractor for ROAD PATH & CULVERT WORKSas listed in Schedule ‘A’Part- VI (Ref prepriced schedule attached seperately) |
| 9 | Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule ‘A’Part- VII(Ref prepriced schedule attached seperately) |
| 10 | Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’Part-VIII(Ref prepriced schedule attached seperately) |
| 11 | Lump sum price worked out by the contractor for FENCING, GATE AND COMPOUND WALL WORKS as listed in Schedule ‘A’Part-IX(Ref prepriced schedule attached seperately) |
| 12 | Lump sum price worked out by the contractor for DEMOLITION/ DISMANTLING WORKSas listed in Schedule ‘A’Part-X (Ref prepriced schedule attached seperately) |
| 13 | Lump sum price worked out by the contractor for RAIN WATER HARVESTING WORKSas listed in Schedule ‘A’Part-XI (Ref prepriced schedule attached seperately) |
| 14 | Lump sum price worked out by the contractor for EXCAVATION, EARTH WORK AND SITE DEVELOPMENT WORKSas listed in Schedule ‘A’Part-XII (Ref prepriced schedule attached seperately) |
| 15 | SCH \"A\" Pt - XIII (MISCELLANEOUS ITEMS) |
| 16 | INTERNAL WATER SUPPLY WORKS NOTE:- For items of internal water supply notes given at the beginning of Sch ‘A’ Part-II (InternalWater Supply Works) shall also be applicable. |
| 17 | S&F of fancy type long nose bib tap, cast copper alloy (ISI Marked) with crutch, or butterfly handle, chromium plated, screwed down, screwed for iron pipe or brass and fixed for 15 mm bore pipe complete all as specified and directed. |
| 18 | S&F of two way bib cock with wall flange quarter turn (low flow) 16mm dia complete all as specified and directed. |
| 19 | S&F of chromium plated urinal spreader for urinal for fixing with 15 mm dia pipe complete all as specified and directed. |
| 20 | INTERNAL ELETRIFICATION WORKS NOTE:- For items of internal Electrifications notes given at the beginning of Sch ‘A’ Part-III (internalElectrification Works) shall also be applicable. |
| 21 | M&L point wiring for lightpoint wiring complete with 2x 1.5 Sq.mm PVC insulation unsheathed muilt-starnded FRLSH copper conductor 1100 Volts grade for phase & neutral draw through in and including not less than 20 mm dia & 1.8 mm thick PVC conduit and conduit accessories, concealed in walls and terminated to and including provision of modular flush boxes adequate size & thick ness not less than 1.6mm with modular metal frame plate and white cover for housing switch, sockets, regulators etc, including 1.5 sqmm PVC insulated unsheathed multi-stranded FRLSH copper conducotor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for the following points .NOTE;-The quoted rate is deemed to inclusive of cost of metal flush boxes, modular white cover plate and blank plate. |
| 22 | (a) One light point controlled by one way 6A modular switch. |
| 23 | (b) One fan point controlled by one way6A modular switch. |
| 24 | (c) One Exhaust fan point controlled by one 6 Amps one-way modular switch |
| 25 | (d) One Wall fan point controlled by one 6 Amps two-way modular switch |
| 26 | (f)One Socket Outlet contolled by 6 Amps modular switch on Independent board |
| 27 | (g) One Socket Outlet controlled by 6 Amps modular switch on same board |
| 28 | All as per Sl item No. 5.01 above, but with cable 2.5 sqmm for phase and neutral & 2.5 sqmm for earth continuity complete for 6/16 Amps socket point |
| 29 | M & L for Point wiring using approved colour coding as per IS ( Red, Black and Green for single phase circuits) with multi-stranded copper conductor 1.5 Sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked with valid CML No in and including medium grade, in stove enamelled steel conduit and conduit accessories concealed in wall/roof/floor etc. ISI marked , including PVC insulated multi-stranded copper conductor 1.5 Sq mm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dollyswitch complete all as specified and directed. |
| 30 | One light point/ fan point controlled by one 16 amp one way flame proof |
| 31 | All as per Sl item No. 5.09 above, but with cable 2.5 sqmm for phase and neutral & 2.5 sqmm for earth continuity complete for 6/16 Amps Flame prrof socket point |
| 32 | Supply & fixing flame proof exhaust fan of size 300 mm sweep,motor 0.25 HP,1440 RPM, AC single phase 230V with blades , frame andlouver,complete all as specified and directed by Engr-in-Charge. |
| 33 | S&F of LED batten, 1x 9/10W, 240V, PF> 0.90, THD <10, colour temperature 5500K to 6500K, CRI> 80, system lumen not less than 120 lm/watt, 2 feet length complete with suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multi stranded copper flexible cable 0.5 sqmm suitable size from ceiling rose complete all as specified and directed. |
| 34 | S&F Sheet metal enclosure for pre wired distribution board double door, vertical type powder coated triple pole & Neutral (VTPN) 4 way with out MCCB, three phase 415 volt with 200 Amps rated tinned electrolytic copper bus bar with neutral link complete concealed in wall complete all as specified and directed by Engr-in-Charge. |
| 35 | S&F of MCB 4P, 16 Amp, 415 volts 10 KA complete all as specified and directed. |
| 36 | S&F of MCB 4P, 40 Amp, 415 volts 10 KA complete all as specified and directed. |
| 37 | S & F LED Security light fitting 25 Watt, system luman efficacy of LED not less than 120 luman/W, PF> 0.95, THD < 10%, colour temprature 6000 to 6500K, CRI > 70, system lumen not less then 3000 Lm, made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens with toughed glass having bottom separate driver compartment with IP 66 Protection and Impact resistant of IK 07 etc and all accessories previewed complete including mounting bracket of 40 mm inner dia light grade GI pipe of required length and shape incl bending, forging or welding etc and suitable bolts and nuts with washers, including connecting with PVC insulated multi stranded copper flexible cable of size 0.5 sqmm three core from ceiling rose to fitting complete all as specified and directed by Engr-in-Charge. |
| 38 | S&Ftelephone/ TV socket with shutter, 1 module including modular cover plate, metal flush box (16 Gauge) concealed in wall/roof complete all as specified and directed by Engr-in-charge. |
| 39 | S&F of MCB SPN 6-20 Amps, 240 volts 10 KA complete all as specified and directed. |
| 40 | EXTERNAL WATERSUPPLY WORKS NOTE:- For items of EXTERNAL WATER SUPPLY WORKS notes given at the beginning of Sch ‘A’ Part-IV (EXTERNAL WATER SUPPLY WORKS) shall also be applicable. |
| 41 | M & L for DI fittings as in bends (any type, radius and angle) Tapers and y type, (straight, bends increasing, or double socket etc. (Tee pieces single branch, ‘Y’ junction, double branch, cross (all socket or socket and spigot) collars caps and plugs etc. complete all as specified and directed. |
| 42 | Supply, laying, connecting, jointing and testing centrifugally cast (Spun) Ductile iron pressure pipe 80mm dia ISI marked conforming to IS-8329-2000 (Reaffirmed 2005 edition 4.1)with socket spigot ends, suitable for “Plus on joints (Tyton Joint)” each standard working lengths supplied with rubber gaskets duly ISI marked for water supply class K-7 with socket with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe without polyethylene sleeves but including “Push on Joint” supplied with ISI marked EPDM rubber gasket conforming to IS-5382-1985 (reaffirmed 2003) laid in trenches complete all as specified and directed. |
| 43 | Supply, laying, connecting, jointing and testing centrifugally cast (Spun) Ductile iron pressure pipe 100mm dia ISI marked conforming to IS-8329-2000(Reaffirmed 2005 edition 4.1) with socket spigot ends, suitable for “Plus on joints (Tyton Joint)” each standard working lengths supplied with rubber gaskets duly ISI marked for water supply class K-7 with socket with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe without polyethylene sleeves but including “Push on Joint” supplied with ISI marked EPDM rubber gasket conforming to IS-5382-1985 (reaffirmed 2003) laid in trenches complete all as specified and directed. |
| 44 | M & L for construction of brick masonry valve pit chamber for the size of 1200x 1200x1000 mm including necessary earth work, PCC coping plastering on internal surface of valve pit. Framed work for the valve pit chamber cover made of MS sheet angle equal angle 40x40x5 mm and MS sheet 3mm thick confirming to Fe410-o and Fe310-o including welding cutting hinges locking arrangement complete and two coated synthetic paints applied on the valve pit cover and MS frame work complete all specified in drawing and directed by Engr-in-charge |
| 45 | M & L for construction of brick masonry valve pit chamber for the size of 900x 900x600 mm including necessary earth work, PCC coping plastering on internal surface of valve pit. Framed work for the valve pit chamber cover made of MS sheet angle equal angle 40x40x5 mm and MS sheet 3mm thick confirming to Fe410-o and Fe310-o including welding cutting hinges locking arrangement complete and two coated synthetic paints applied on the valve pit cover and MS frame work complete all specified in drawing and directed by Engr-in-charge |
| 46 | EXTERNAL ELETRICWORKS NOTE:- For items of EXTERNAL ELECTRIC WORKS notes given at the beginning of Sch ‘A’ Part-V (EXTERNAL ELETRIC WORKSshall also be applicable. |
| 47 | M&L for supply, install, connecting and commissioning ofCPRI approved main LT distribution panel board (LT PANEL 1, main panel), outdoor type, both side openable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof IP-54, cubical type, fabricated from 3.15 mm thick CRCA sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4 Nos insulated bus bar each made of high conductivity aluminium suitable for 400 Amps, prewired with suitable size of copper cable including PCC work and panel mounted on angle Iron of size 40x40x6mm and length of leg should not be less than 0..9M including fixing of arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following.(A) INCOMING(i) MCCB, 4 Pole, 415V, 50HZ 250 Amps with breaking capacity of Icu=ICS=35/36KA, Adjustable thermal and fixed magnetic release -01Nos (B) OUTGOING(i) Digital Multifuction meter withselector switch and three current transformers of suitable ratio and capacity -01 Set.(ii) LED type Phase indicator lamps for three phases set of three - 01 set.(iii) Busbar chamber having insulatedaluminiumbusbar, each suitable for 400 Amps for three phases and neutral -01 set.(iv) MCCB, 4 Pole,415V, 50HZ 100 Amps with breaking capacity of Icu=ICS=16KA, Adjustable thermal and fixed magnetic release -01Nos.(v) MCCB, 4 Pole,415V, 50HZ 63 Amps with breaking capacity of Icu=ICS=16KA, Adjustable thermal and fixed magnetic release -02Nos.(vi) MCB, 4 POLE of capacity32 AMPS,10 kA at 415V - 03 Nos.(vii) Spare space for MCCB - 01 No. |
| 48 | S & F oftubing galvanised 40 mm bore light gradeISI marked bent to the shape of bracket 1.2 Mtr in length for mounting of street light fitting and fixed on pole with clamp and nut, bolt and washerwith two coat paint complete all as directed. |
| 49 | M&L for supply, install, connecting and commissioning ofCPRI approved main LT distribution panel board (LT PANEL 2, main Office), outdoor type, both side openable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof IP-54, cubical type, fabricated from 3.15 mm thick CRCA sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4 Nos insulated bus bar each made of high conductivity aluminium suitable for 250 Amps, prewired with suitable size of copper cable including PCC work and panel mounted on angle Iron of size 40x40x6mm and length of leg should not be less than 0..9M including fixing of arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following.(A) INCOMING(i) MCCB, 4 Pole, 415V, 50HZ 160 Amps with breaking capacity of Icu=ICS=25KA, Adjustable thermal and fixed magnetic release -01Nos . (B) OUTGOING(i) Digital Multifuction meter withselector switch and three current transformers of suitable ratio and capacity -01 Set.(ii) LED type Phase indicator lamps for three phases set of three - 01 set.(iii) Busbar chamber having insulated aluminium busbar, each suitable for 250 Amps for three phases and neutral -01 set.(iv) MCCB, 4 Pole,415V, 50HZ 100 Amps with breaking capacity of Icu=ICS=16KA, Adjustable thermal and fixed magnetic release -01Nos.(v) MCCB, 4 Pole,415V, 50HZ 63 Amps with breaking capacity of Icu=ICS=16KA, Adjustable thermal and fixed magnetic release -02Nos.(vi)MCB, 4 POLE of capacity32 AMPS,10 kA at 415V - 02 Nos.(vii) MCB, 2 POLE of capacity32 AMPS,10 kA at 240V - 02 Nos.(viii) Spare space for MCCB - 01 No |
| 50 | M&L for supply, install, connecting and commissioning ofCPRI approved main LT distribution panel board (LT PANEL 3, Single living ORs), outdoor type, both side openable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof IP-54, cubical type, fabricated from 3.15 mm thick CRCA sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4 Nos insulated bus bar each made of high conductivity aluminium suitable for 150 Amps, prewired with suitable size of copper cable including PCC work and panel mounted on angle Iron of size 40x40x6mm and length of leg should not be less than 0..9M including fixing of arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following.(A) INCOMING(i) MCCB, 4 Pole, 415V, 50HZ 100 Amps with breaking capacity of Icu=ICS=25KA, Adjustable thermal and fixed magnetic release-01Nos. (B) OUTGOING(i) Digital Multifuction meter withselector switch and three current transformers of suitable ratio and capacity -01 Set.(ii) LED type Phase indicator lamps for three phases set of three - 01 set.(iii) Busbar chamber having insulated aluminium busbar, each suitable for 150 Amps for three phases and neutral -01 set.(iv) MCCB, 4 Pole,415V, 50HZ 63 Amps with breaking capacity of Icu=ICS=16KA, Adjustable thermal and fixed magnetic-01Nos.(v)MCB, 4 POLE of capacity32 AMPS,10 kA at 415V - 02 Nos.(vi) MCB, 2 POLE of capacity32 AMPS,10 kA at 240V - 02 Nos.(vii) Spare space for MCCB - 01 No. |
| 51 | Supply, installation and testing of 16 mtrs high mast confirming to IS-875 (Part-III) - 1987, made out of steel plates confirming to BS-M10025 cut and holded to form a tapered polygonal section in two section having 20 sides, plate thickness not less than of base section 4 mm and of top section 3 mm , length of base and top section as 8.25 mm and dia of base section 360 mm and top section 150 mm in two section suitable for wind speed of 180 km/hour with double drum winch and stainless steel rope of grade AISI 304, 7/19 construction, 6 mm dia tralling cable copper conductor 5 core, 2.5 sqmm EPR/PCP insulated, PCP sheathed incl power tools of 1 HP/1.5 HP capacity (motorised system for bringing up and down the lights) and aviation light (LED type) lightening arrestor spike incl feeder pillar suitable for operation of light and motor as per manufacturer design. The mast should consist of8 NosLED flood lightfitting 200 Watt with external control gear box if needed with all accessories incl lamps mounted on suitable brackets as per manufacturers catalogue incl RCC foundation excavation and earth work in any type of soil complete all as per manufacturer inctruction/design and its reflection should be carried under the supervision of manufacturer, complete all as specified and directed. (a) ERRECTION PART:-(i) Construction of suitable shallow foundation with design mix (M 25) concrete for the high mast considering the safe soil bearing capacity at site as 100/sqmtr at 2 mtr depth with all material and labour-Job- 01. (ii)Errection of the high mast with the help of suitable equipment and wiring of luminaries with all wiring material and labour- Job - 01.(iii) Installation of control panel suitable fdn incl all material and labour Job 01. |
| 52 | (b) LT OUTDOOR PANEL :-Fabricate, supply,install, testing and commissioning of LT out door total enclsoed LT panel board of size 0.75mX0.5mX0.3m approx totally enclosed made out of 3mm thick CRCA sheet dust and vermin proof IP-54, with front opening 440V 3 Phase 4 wire having200 Amps capacity aluminium bus bar insulated wth sleeves, incoming MCCB TPN 63 Amps 440 Volts 25 KA - 01 No and copper wiring with multistranded cable including timer switch electronic type 01 No with necessary MCBs SP 10 Amp 09 Nos contactors etc, cable glands, lugs,suitable control circuit for automatic switchingon and off of the mastand two coats of synthetic enamel paint over a coat of red oxide primer and making necessary pedestal 300 mm height from floor level with PCC work complete all as specified. (c) Provn of wiring from panel to light fitting with single core 4 sqmm copper conductor cable drawn through MS rigid/ flexible conduit with necessary fittings400Mtr. (d) Provn of single pointed air termination rod and necessary fitment required for protection against lightning protection. (Earthing shall be measured and paid seperately). (e) Testing and commisioning:- (i) Testing & Commissioning of above high mast system complete. Note:- Rate quoted against this item shall be deemed to included forfor all (i.e a to e) above provisions. |
| 53 | Supply and fix junction box Single Pole and neutral enclosure compression gland2with connector and clamp for pole mounting with two nos of nut bolt and washers and socket complete of size not less than 12\"x10\"x4\" complete all as specified and directed. |
| 54 | Supply and fix timer switches 250Vsingle phase of 20 amps rating wih contractor fitted inside steel enclouser complete all as specified and as directed. |
| 55 | S&F for LED decorative post-top light 35 watts, IP65, energysaving, environment friendly long life aesthetically designed withsymmetrical light distribution, spun aluminium landscape luminaire with high power LED as light source complete all as specified and directed. |
| 56 | S&F for LED bollard light 8Watts, IP 65 two feet height, the elegant yet minimalsitic design actssilent observer and giving lihgt, diffuser at the upper portion acts a beacon of path guidance in a landscape environment complete all as specified and as directed. |
| 57 | M&L for all-in-one solar street light made 24Watts with high efficiency mono crystalline solar PV module, lithium ferro phosphate battery with in-built BMS technology, high efficiency LED, MPPT solar charge controller and aluminium extruded body & is specially programmed to automatically control the dimming and brightness of light which increases the backup time complete all as specified and as directed. |
| 58 | S&F Modular telephone jack, 1 module to be fixed on moduler switch board complete all as specified and directed. |
| 59 | S&F Modular TV jack 1 module to be fixed on modular switch board complete all as specified and directed. |
| 60 | SEWAGE DISPOSAL WORKSNOTE:- For items of SEWAGE DISPOSAL WORKS notes given at the beginning of SCHEDULE \"A\" PART -VIII (SEWAGE DISPOSAL WORKS) shall also be applicable. |
| 61 | S & F of HDPE DWE (double wall corrugated) sewagepipe SN-8 ISI Mark as per IS 16908 Part I- 2013 laid in trenches joined and tested as per manufactures instruction complete all as specified and directed for the following size:- |
| 62 | (a)150 MM bore pipe |
| 63 | (b) 200 MM bore pipe |
| 64 | Construction ofBrick Septic Tank of 100 Users includingexcavation, in any type of soil, PCC foundation, walls of fly ash brick masonry with top cover of M25 concrete including intercepting chamber and screen chamber made ofBrick masonary in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCI complete as specified (TD No CEBZ/TD/77/2011 Sheet 1/3 to 3/3) |
| 65 | Construction ofBrick Septic Tank of 50 Users includingexcavation, in any type of soil, PCC foundation, walls of fly ash brick masonry with top cover of M25 concrete including intercepting chamber and screen chamber made ofBrick masonary in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCI complete as specified (TD No CEBZ/TD/76/2011 Sheet 1/2 to 2/2) |
| 66 | Construction ofRCC hume pipe septic tank designed to carry sewage and sludge water, excavation in any type of soil, PCC (1:4:8) type D-2 as in foundation, vent shaft, connection etc. for 10 users complete all as specified and directed. |
| 67 | Construction of Soakage well includingexcavation, in any type of soil, PCC foundation walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made ofBrick masonary in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats3.00m dia x 3.00 m deep effective depthcomplete all as specified and directed (Drg NoCEBZ/TD/78/2011 sheet 1/2 to 2/2. |
| 68 | Construction of Soakage well includingexcavation, in any type of soil, PCC foundation walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made ofBrick masonary in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats1.20 mdia x 3.00 m deep effective depthcomplete all as specified and directed (Drg NoCEBZ/TD/78/2011 sheet 1/2 to 2/2. |
| 69 | Fencing, Gate and Comound Wall WorksNOTE:- For items of Fencing, Gate and Comound Wall Works notes given at the biginning of Schedule \"A\" Part-IX (Fencing, Gate and Comound Wall Works)shall also be applicable. |
| 70 | Provision of steel gate of size 5.5 mtr wide all as shown in on drg No CEBZ/TD/104/2011 Sheet No 1/3 to 3/3 with MS work confirming to Fe 290 Gde E-165 including gate pillar and necessary earthwork etc. complete all as specified and directed.Note:- Contractor shall make provision of gate light, however gate light shall be measured an paid separately as per requirement. |
| 71 | Excavation earth work and site development worksNOTE:- For items of Excavation earth work and site development wotks notes given at the beginning of SCHEDULE \"A\" PART -XII (Excavation earth work and site development wotks) shall also be applicable. |
| 72 | Approved earth filling with approved soil brought from outside MD land filling in tranches or paving laid in layers not exceeding 25 cm thick spread, levelled rammed including watering etc. complete all as specified and directed. |
| 73 | DEMOLITION/ DISMANTLING WORKSNOTE:- For items of Demolition/Dismantling Works notes given at the beginning of SCHEDULE \"A\" PART -X (Demolition/ Dismantling Works) shall also be applicable. |
| 74 | Taking down main switch, DB box including MCBs of any capacity complete all as specified and directed. |
| 75 | Taking down service connection including disconnecting from pole to DG/Main switch complete all as specified and directed. |
| 76 | Taking down/up of steel tubing of 80 mm dia GI pipe including all fitting complete all as specified and directed. |
| 77 | ARBORICULTUREWORKS |
| 78 | Supply & stacking of good/ sweet earth/ soil from outside MoD land, well sieved 90% to pass through IS sieve of 10mm size free from stone rubbish like lumps, stones, roots and other foreign material suitable for gardening.The soil should be fresh from quarry. The colour of the soil generally be brown incl cost of all royalty and carriage. All tools plants, taxes octroi etc complete all as specified and directed. Note : Measurements will be reduced by 20% for payment towards voids. |
| 79 | Supplying and stacking of framyard manure at site including royalty and carriage with any lead complete all as specified and directed (Note : Farm yard manure measured in stack will be reduced by 25% against the total volume of good earth used in filling towardsvoids. |
| 80 | Material and labour for plantingFicus Daniallaand 600mm hight incl following:(i) Digging hole of size 600mm dia x 600mmdepth,removing & conveyingexcavated soil to a distance exc 50m and n.exc 250m.(ii) Filling the hole with fresh garden soil, farm yard manure in 3:1 proportion upto a heightr of 0.60m levelling and watering previous night as specified and approved by Engr-in-Charge and maintaining for a minimum period of 02 yrsor till formation of well established plants whichever is later complete all as directed. (iii) Adequate proportion of DAP, Urea,bone dust, oil cake etc to be provided accordingly.(Note : Good earth (fresh garden soil) & farm yard manure shall be measured and paid for separately). |
| 81 | Material and labour for planting Ficus Benjamina and 600mm hight incl following:(i) Digging hole of size 600mm dia x 600mmdepth,removing & conveyingexcavated soil to a distance exc 50m and n.exc 250m.(ii) Filling the hole with fresh garden soil farm yard manure in 3:1 proportion upto a heightr of 0.60m levelling and watering previous night as specified and approved by Engr-in-Charge and maintaining for a minimum period of 02 yrsor till formation of well established plants whichever is later complete all as directed. (ii) Adequate proportion of DAP, Urea,bone dust, oil cake etc to be provided accordingly.(Note : Good earth (fresh garden soil) & farm yard manure shall be measured and paid for separately). |
| 82 | Material and labour for plantingPygmy date palm and 600mm hight incl following:(i) Digging hole of size 600mm dia x 600mmdepth,removing & conveyingexcavated soil to a distance exc 50m and n.exc 250m.(ii) Filling the hole with fresh garden soil farm yard manure in 3:1 proportion upto a heightr of 0.60m levelling and watering previous night as specified and approved by Engr-in-Charge and maintaining for a minimum period of 02 yrsor till formation of well established plants whichever is later complete all as directed. (ii) Adequate proportion of DAP, Urea,bone dust, oil cake etc to be provided accordingly.(Note : Good earth (fresh garden soil) & farm yard manure shall be measured and paid for separately). |
| 83 | Material and labour for plantingGulmohar and 900mm hight incl following:(i) Digging hole of size 600mm dia x 600mmdepth,removing & conveyingexcavated soil to a distance exc 50m and n.exc 250m.(ii) Filling the hole with fresh garden soil farm yard manure in 3:1 proportion upto a heightr of 0.60m levelling and watering previous night as specified and approved by Engr-in-Charge and maintaining for a minimum period of 02 yrsor till formation of well established plants whichever is later complete all as directed. (ii) Adequate proportion of DAP, Urea,bone dust, oil cake etc to be provided accordingly.(Note : Good earth (fresh garden soil) & farm yard manure shall be measured and paid for separately). |
| 84 | Material and labour for plantingAlstonia Scholaris (Local name - Satparni) and 1200mm hight incl following:(i) Digging hole of size 600mm dia x 600mmdepth,removing & conveyingexcavated soil to a distance exc 50m and n.exc 250m.(ii) Filling the hole with fresh garden soil farm yard manure in 3:1 proportion upto a heightr of 0.60m levelling and watering previous night as specified and approved by Engr-in-Charge and maintaining for a minimum period of 02 yrsor till formation of well established plants whichever is later complete all as directed. (ii) Adequate proportion of DAP, Urea,bone dust, oil cake etc to be provided accordingly.(Note : Good earth (fresh garden soil) & farm yard manure shall be measured and paid for separately). |
| 85 | Material and labour for plantingGarmalo (Local name - Amaltash) and 600mm hight incl following:(i) Digging hole of size 600mm dia x 600mmdepth,removing & conveyingexcavated soil to a distance exc 50m and n.exc 250m.(ii) Filling the hole with fresh garden soil farm yard manure in 3:1 proportion upto a heightr of 0.60m levelling and watering previous night as specified and approved by Engr-in-Charge and maintaining for a minimum period of 02 yrsor till formation of well established plants whichever is later complete all as directed. (ii) Adequate proportion of DAP, Urea,bone dust, oil cake etc to be provided accordingly.(Note : Good earth (fresh garden soil) & farm yard manure shall be measured and paid for separately). |
| 86 | Material and labour for plantingNeemand 600mm hight incl following:(i) Digging hole of size 600mm dia x 600mmdepth,removing & conveyingexcavated soil to a distance exc 50m and n.exc 250m.(ii) Filling the hole with fresh garden soil farm yard manure in 3:1 proportion upto a heightr of 0.60m levelling and watering previous night as specified and approved by Engr-in-Charge and maintaining for a minimum period of 02 yrsor till formation of well established plants whichever is later complete all as directed. (ii) Adequate proportion of DAP, Urea,bone dust, oil cake etc to be provided accordingly.(Note : Good earth (fresh garden soil) & farm yard manure shall be measured and paid for separately). |
| 87 | Material and labour for plantingBakoli and 600mm hight incl following:(i) Digging hole of size 600mm dia x 600mmdepth,removing & conveyingexcavated soil to a distance exc 50m and n.exc 250m.(ii) Filling the hole with fresh garden soil farm yard manure in 3:1 proportion upto a heightr of 0.60m levelling and watering previous night as specified and approved by Engr-in-Charge and maintaining for a minimum period of 02 yrsor till formation of well established plants whichever is later complete all as directed. (ii) Adequate proportion of DAP, Urea,bone dust, oil cake etc to be provided accordingly.(Note : Good earth (fresh garden soil) & farm yard manure shall be measured and paid for separately). |
| 88 | Material and labour for planting Kadamb and 600mm hight incl following:(i) Digging hole of size 600mm dia x 600mmdepth,removing & conveyingexcavated soil to a distance exc 50m and n.exc 250m.(ii) Filling the hole with fresh garden soil farm yard manure in 3:1 proportion upto a heightr of 0.60m levelling and watering previous night as specified and approved by Engr-in-Charge and maintaining for a minimum period of 02 yrsor till formation of well established plants whichever is later complete all as directed. (ii) Adequate proportion of DAP, Urea,bone dust, oil cake etc to be provided accordingly.(Note : Good earth (fresh garden soil) & farm yard manure shall be measured and paid for separately). |
| 89 | Material and labour for plantingand developing pyramid type Ashoka tree of 600 mm hight incl following:(i) Digging hole of size 600mm dia x 600mmdepth,removing & conveyingexcavated soil to a distance exc 50m and n.exc 250m.(ii) Filling the hole with fresh garden soil farm yard manure in 3:1 proportion upto a heightr of 0.60m levelling and watering previous night as specified and approved by Engr-in-Charge and maintaining for a minimum period of 02 yrsor till formation of well established plants whichever is later complete all as directed. (ii) Adequate proportion of DAP, Urea,bone dust, oil cake etc to be provided accordingly.(Note : Good earth (fresh garden soil) & farm yard manure shall be measured and paid for separately). |
| 90 | Material and labour for planting Morpankhi and 600mm hight incl following:(i) Digging hole of size 600mm dia x 600mmdepth,removing & conveyingexcavated soil to a distance exc 50m and n.exc 250m.(ii) Filling the hole with fresh garden soil farm yard manure in 3:1 proportion upto a heightr of 0.60m levelling and watering previous night as specified and approved by Engr-in-Charge and maintaining for a minimum period of 02 yrsor till formation of well established plants whichever is later complete all as directed. (ii) Adequate proportion of DAP, Urea,bone dust, oil cake etc to be provided accordingly.(Note : Good earth (fresh garden soil) & farm yard manure shall be measured and paid for separately). |
| 91 | Material and labour for plantingBottle Palm and 600mm hight incl following:(i) Digging hole of size 600mm dia x 600mmdepth,removing & conveyingexcavated soil to a distance exc 50m and n.exc 250m.(ii) Filling the hole with fresh garden soil farm yard manure in 3:1 proportion upto a heightr of 0.60m levelling and watering previous night as specified and approved by Engr-in-Charge and maintaining for a minimum period of 02 yrsor till formation of well established plants whichever is later complete all as directed. (ii) Adequate proportion of DAP, Urea,bone dust, oil cake etc to be provided accordingly.(Note : Good earth (fresh garden soil) & farm yard manure shall be measured and paid for separately). |
| 92 | Material and labour for plantingBottle Brush and 600mm hight incl following:(i) Digging hole of size 600mm dia x 600mmdepth,removing & conveyingexcavated soil to a distance exc 50m and n.exc 250m.(ii) Filling the hole with fresh garden soil farm yard manure in 3:1 proportion upto a heightr of 0.60m levelling and watering previous night as specified and approved by Engr-in-Charge and maintaining for a minimum period of 02 yrsor till formation of well established plants whichever is later complete all as directed. (ii) Adequate proportion of DAP, Urea,bone dust, oil cake etc to be provided accordingly.(Note : Good earth (fresh garden soil) & farm yard manure shall be measured and paid for separately). |
| 93 | Material and labour for plantingChandniand 600mm hight incl following:(i) Digging hole of size 600mm dia x 600mmdepth,removing & conveyingexcavated soil to a distance exc 50m and n.exc 250m.(ii) Filling the hole with fresh garden soil farm yard manure in 3:1 proportion upto a heightr of 0.60m levelling and watering previous night as specified and approved by Engr-in-Charge and maintaining for a minimum period of 02 yrsor till formation of well established plants whichever is later complete all as directed. (ii) Adequate proportion of DAP, Urea,bone dust, oil cake etc to be provided accordingly.(Note : Good earth (fresh garden soil) & farm yard manure shall be measured and paid for separately). |
| 94 | Material and labour for planting Kachnar of 600mm hight incl following:(i) Digging hole of size 600mm dia x 600mmdepth,removing & conveyingexcavated soil to a distance exc 50m and n.exc 250m.(ii) Filling the hole with fresh garden soil farm yard manure in 3:1 proportion upto a heightr of 0.60m levelling and watering previous night as specified and approved by Engr-in-Charge and maintaining for a minimum period of 02 yrs or till formation of well established plants whichever is later complete all as directed. (ii) Adequate proportion of DAP, Urea,bone dust, oil cake etc to be provided accordingly.(Note : Good earth (fresh garden soil) & farm yard manure shall be measured and paid for separately). |
| 95 | Material and labour for plantingJamun of 600mm hight incl following:(i) Digging hole of size 600mm dia x 600mmdepth,removing & conveyingexcavated soil to a distance exc 50m and n.exc 250m.(ii) Filling the hole with fresh garden soil farm yard manure in 3:1 proportion F24upto a heightr of 0.60m levelling and watering previous night as specified and approved by Engr-in-Charge and maintaining for a minimum period of 02 yrsor till formation of well established plants whichever is later complete all as directed. (ii) Adequate proportion of DAP, Urea,bone dust, oil cake etc to be provided accordingly.(Note : Good earth (fresh garden soil) & farm yard manure shall be measured and paid for separately). |
| 96 | Material and labour for plantingMangoof 600mm hight incl following:(i) Digging hole of size 600mm dia x 600mmdepth,removing & conveyingexcavated soil to a distance exc 50m and n.exc 250m.(ii) Filling the hole with fresh garden soil farm yard manure in 3:1 proportion upto a heightr of 0.60m levelling and watering previous night as specified and approved by Engr-in-Charge and maintaining for a minimum period of 02 yrsor till formation of well established plants whichever is later complete all as directed. (ii) Adequate proportion of DAP, Urea,bone dust, oil cake etc to be provided accordingly.(Note : Good earth (fresh garden soil) & farm yard manure shall be measured and paid for separately). |
| 97 | Material and labour for plantingAmla of 600mm hight incl following:(i) Digging hole of size 600mm dia x 600mmdepth,removing & conveyingexcavated soil to a distance exc 50m and n.exc 250m.(ii) Filling the hole with fresh garden soil farm yard manure in 3:1 proportion upto a heightr of 0.60m levelling and watering previous night as specified and approved by Engr-in-Charge and maintaining for a minimum period of 02 yrsor till formation of well established plants whichever is later complete all as directed. (ii) Adequate proportion of DAP, Urea,bone dust, oil cake etc to be provided accordingly.(Note : Good earth (fresh garden soil) & farm yard manure shall be measured and paid for separately). |
| 98 | Material and labour for plantingGuava of 600mm hight incl following:(i) Digging hole of size 600mm dia x 600mmdepth,removing & conveyingexcavated soil to a distance exc 50m and n.exc 250m.(ii) Filling the hole with fresh garden soil farm yard manure in 3:1 proportion upto a heightr of 0.60m levelling and watering previous night as specified and approved by Engr-in-Charge and maintaining for a minimum period of 02 yrs or till formation of well established plants whichever is later complete all as directed. (ii) Adequate proportion of DAP, Urea,bone dust, oil cake etc to be provided accordingly.(Note : Good earth (fresh garden soil) & farm yard manure shall be measured and paid for separately). |
| 99 | Material and labour for planting Lemonof 600mm hight incl following:(i) Digging hole of size 600mm dia x 600mmdepth,removing & conveyingexcavated soil to a distance exc 50m and n.exc 250m.(ii) Filling the hole with fresh garden soil farm yard manure in 3:1 proportion upto a heightr of 0.60m levelling and watering previous night as specified and approved by Engr-in-Charge and maintaining for a minimum period of 02 yrsor till formation of well established plants whichever is later complete all as directed. (ii) Adequate proportion of DAP, Urea,bone dust, oil cake etc to be provided accordingly.(Note : Good earth (fresh garden soil) & farm yard manure shall be measured and paid for separately). |
| 100 | Material and labour for planting Bel of 600mm hight incl following:(i) Digging hole of size 600mm dia x 600mmdepth,removing & conveyingexcavated soil to a distance exc 50m and n.exc 250m.(ii) Filling the hole with fresh garden soil farm yard manure in 3:1 proportion upto a heightr of 0.60m levelling and watering previous night as specified and approved by Engr-in-Charge and maintaining for a minimum period of 02 yrsor till formation of well established plants whichever is later complete all as directed. (ii) Adequate proportion of DAP, Urea,bone dust, oil cake etc to be provided accordingly.(Note : Good earth (fresh garden soil) & farm yard manure shall be measured and paid for separately). |
| 101 | Material and labour for planting Anarof 600mm hight incl following:(i) Digging hole of size 600mm dia x 600mmdepth,removing & conveyingexcavated soil to a distance exc 50m and n.exc 250m.(ii) Filling the hole with fresh garden soil farm yard manure in 3:1 proportion upto a heightr of 0.60m levelling and watering previous night as specified and approved by Engr-in-Charge and maintaining for a minimum period of 02 yrsor till formation of well established plants whichever is later complete all as directed. (ii) Adequate proportion of DAP, Urea,bone dust, oil cake etc to be provided accordingly.(Note : Good earth (fresh garden soil) & farm yard manure shall be measured and paid for separately). |
| 102 | Material and labour for plantingBamboo of 1200mm hight incl following:(i) Digging hole of size 600mm dia x 600mmdepth,removing & conveyingexcavated soil to a distance exc 50m and n.exc 250m.(ii) Filling the hole with fresh garden soil farm yard manure in 3:1 proportion upto a heightr of 0.60m levelling and watering previous night as specified and approved by Engr-in-Charge and maintaining for a minimum period of 02 yrsor till formation of well established plants whichever is later complete all as directed. (ii) Adequate proportion of DAP, Urea,bone dust, oil cake etc to be provided accordingly.(Note : Good earth (fresh garden soil) & farm yard manure shall be measured and paid for separately). |
| 103 | Material and labour for planting and developing lawn grass (phospolen) incl following:-(a) Preparing soil base by excavation/ploughing and loosening of ground upto 15cm and removing unwanted material, grass stones etc to a distance exceeding 50m but n.exc 250m.(b) Mixing good earth (fresh garden soil) & farm yard namure throughly in 3:1 proportion and filling in excavated area to a height of 15 cm and levelling completely.Note : Good earth (fresh garden soil) & farm yard manure shall be measured and paid for seperately).(c)Watering on previous night and planting cutting of required variety above plants at required spacing so as to form cover on planted area full growthand maintiaining for a minimum period of 02 yrsor till formation of well flower plantedwhichever is later to the satisaction of Engineer-in-Charge by watering, weeding, clipping and rolling etc complete). |
| 104 | Material and labour for planting and developinghedge plants namingalternanthera / codiaeum and 600 mm (minimum) height and 400 mmwide hedge etcincl following:-(a) Preparing soil base by excavation/ploughing and loosening of ground upto 60cm and removing unwanted material, grass stones etc to a distance exceeding 50m but n.exc 250m.(b)Watering on previous night and planting cutting of required variety above plants at required spacing so as to form cover on planted area full growthand maintiaining for a minimum period of 02 yrs or till formation of well flower plantedwhichever is later to the satisaction of Engineer-in-Charge by watering, weeding, clipping and rolling etc complete). |
| 105 | SOLAR ROOF TOP SOLAR PLANT GENERATION 90Kwp |
| 106 | Design,Supply, install,testing and commissioning of ON Grid connected roof top solar generation system of capacity 40 KWp AC capacity all as specified in PS and directed as per PS clause and specification as follows (ForAdm Bldg):- |
| 107 | (A) Supply, Installation, testing and commissioning of 40 KWp SPV system comprising of 540/545/535Wpsolar photo voltic modules/array of high efficiency made of mono crystalline silicon solar PV cells with supply and fix of terminal box on the module havingprovision for opening & replacing the cable etc.as per direction of IEC. The general features of PV modules shall be as given below :- a) The module shell be made up mono crystalline silicon cells. b) The interconnected cells shall be laminatedin vacuum to withstand adverse environmental conditions. c) The module frame is made of corrosion resistant materials, preferably having aluminium anodized finish. d) The minimum clearance between the lower edge of the modules & the developed ground level shall be 300 mm. e) Surge arresting devices to be provided at junction box and module shall be provided with bypass diode. f) The SPV module must be IEC 61215, IEC 61730 part I & part II, IEC 61701 certified from any of the accredited certifying agencies. g) Each solar PV module must be warranted by manufacturer at least 90% rated power at the end of 10 years & 80% at the end of 25 years. Note: Qty of PV module shall be decided as per OEM recommendation, design and layout drawing submitted to department duly approved by CWE BhopalNote :- (i) Makes of panel provided shall be as per MNRE specification/ standard and registered in ALMM. (ii) 5% spare qty of modules shall be provided by the contractor for repair / replacement purpose. (iii) Addln module shall be provided / installed by the contractor to meet specified power output incase if the same not achived during testing and commissioning without any extra cost.(iv) Each PV module used in any solar power project must use a RF identification tag. The following information must be mentioned in the RFID used on each module:- |
| 108 | (iv) Each PV module used in any solar power project must use a RF identification tag. The following information must be mentioned in the RFID used on each module:- (a) Name of the manufacturer of PV Module(b) Name of the Manufacturer of Solar cells(c) Month and year of the manufacture for solar cells and the module(d) Countryoforigin(make in INDIA only)(e) I-Vcurve for the module(f) Wattage, Im, Vm and FF for the module(g) Unique Serial No and Model No of the module(h) Date and year of obtaining IEC PV module qualification certificate(j) Name of the test lab issuing EC certificate(k) Other relevant information on traceability of solar cells & module. |
| 109 | (B) Module Mounting Structure (MMS)Supply & fixing of the anti-corrosive factory made Gl structure on the RCC Roof for fixing of PV modules by fixing of suitable size fastner, spring washer, nuts & bolt. The minimum thickness of galvanization & mounting steel structure shall be as per IS 47592 & IS 2061-1992 respectively withstand the wind load of 180 Km/hr. as per IS 875. The array structure shall be fixed properly using maintenance free earthing kit. Note:- (i)The total load for roof top SPV should be less than 60 Kg/m2.(ii) The design of module mounting structure complying load withstand as per relevant IS alongwith fixing arrangement on roof shall be submittedby the contractor duly vetted from IIT/NIT/Govt Engg college for approval by CWE.(iii) The material shall be corrosion resistant and electrolyticaly compatible with material used in module frame. (iv)The fasteners should be of stainless steel and should allow easy replacement of any module.(v) The minimum clearance of the structure from the roof levelshould be 300 mm. |
| 110 | (C) Solar DC Cables:- (i) Supply & laying of 1.1kv single core multi strandedPVC FRLSH insulated & unsheathed copper wire/ copper cable for 3 ph supply in ISI marked PVC rigid conduit pipe by saddling as per direction of IEC. (For Solar Array DC supply connection). Note : (i) The size of cable shall be as per design given by OEM & approved by vender empanelled by DISCOM.(ii)Cable should be passes through PVC rigid pipe and pipe should be fixed properly inside cable tray for easily maintenance, is included in quoted rate |
| 111 | (D) DC Combine boxA DC combine box shall be used to combine the DC cables of the solar module array with DC fuse protection for the outgoing DC cables to the DC distribution box. |
| 112 | (E) Array junction boxes_-The number of junction boxes as per design given by OEM are to be provided in the PV array for termination of coinnecting cables. All wire/cables must be terminated through cable lugs. Copper busbar/terminated blocks housed in the junction box conforming to IP 65 degree of protection with EPDM rubber gasket to prevent water entry. Junction boxes shall be mounted on the MMS such that they are easily accessible and protected from direct sunlight & harsh weather. |
| 113 | (F) On Grid Power Conditioning unit ( Inverter):-Supply & installation of 415V 3-ph, 50 Hz microprocessor DSP type grid connected Inverters which converts DC energy produce by the solar array to AC energy such that it synchronizes with the existing AC power source on site. Provisioning of power manager to get all parameter details. The Inverter shall have inbuilt MPPT (Maximum Power Point Tracker) feature so as to extract maximum power from PV modules & the MPPT units environmental testing should qualify IEC 60068-2 (1,2,14,30)/ Equivalent BIS standard. (The voltage variation of +/- 10% & frequency variation +/-3 Hz) Note :-(i) No of inverters shall be provisioned as per design given by OEM. (ii) Inverter should have internal protection arrangements against any sustainable fault in feeder line and against the lightning on feeder.(iii) Should have isolating transformer(iv) Inverter efficiency >97% (without inbuilt galvanic isolation) and >93% (with inbuilt galvanic isolation). (v) No load losses shall be less than 1% of rated power.(vi) The above quoted rate is inclusive of MS structure stand duly fixed on roof for placing inverter. |
| 114 | (G) Solar meter & Net meter:-As per DISCOM requirement to be provided.(H) AC Distribution Board:-(i) Supply & installation of 415V 3-ph 50Hz AC distribution board control AC power from PCU/ Inverter & provided by nacessary surge arrestors system and solar energy meter (KWH) with IP65 protection and suitable capacity MCCBs.; Qty-01 No Note: ACDB shall be covered as per OEM design in such a way that structure must sustain 180 km/hr wind speed. The cost of provn for same is inclusive in quoted rate. |
| 115 | (J) AC Cables:-(ii) Distribution wiring in 1.1kv single core multi strandedPVC FRLSH insulated & unsheathed copper wire fixed on wall on PVC batten or saddle(For AC power supply from Inverter to AC distribution board Panel).Note :- (i) The size of cable shall be as per design given by OEM & approved by vender empanelled by DISCOM.(K) Protection:-The system shall be provided with all necessary protection like earthing, lightening & surge protection as per relevant standard.(L) Performance testing:-Ratio between the theoretical energy outputs of the SPV plant is termed as performance ratio and is measured in accordance with IEC 61724. Based on prevailing climatic and temperature conditions in India, a performance ratio of 75% is expected for crystalline modules. (M) Other Misc items:-As per requirement given by OEM and approved by DISCOM to be provided.(N) Earthing:_As per MNRE specifications to be provided.(O) Lightening protection:-As per MNRE specifications to be provided.(P) Installation, Testing & Commissioning:-As per safety norms of SERC/CEA to be provided.(Q) O&M and Warranty:-5 years from the date of commissioning to be provided. |
| 116 | Note: The quoted rate deemed inclusive of the following:-(i) Transportation charges with Transportation Insurance for the all material of on grid solar roof top system including loading & unloading at site from workshop.(ii) Insurance for the complete system for the 5 Years.(iii) AMC-Suraksha which include 24 site Maintenance visits, Response time 2 hrs and turn around time 48 hrs, Monthly plant performance report. (v) Guarantee and warranty of Solar panel and connected devices is to be submitted to department. (vi) The report of generated unit of solar power on monthly basis is to be submitted to (iv) As per performance obligation, the contractor shall maintain minimum capacity utilization factor (CUF) of 13%. The report shall be submitted by the contractor to accepting officer as per guidelines promulgated by SECI. (v) Satisfactorily testing and commissioning of the system is to be done by the contractor in presence of the rep of accepting officer and the report of the complete system is submitted to department. |
| 117 | All as per item No 13.01 abovebut of 20 kwp AC capacity(ONE FOR JCO Mess) complete all as specified and directed. |
| 118 | All as per item No 13.01 above but of 15 kwp AC capacity(ONE FOR Single Living OR AND ONE FOR JCO Living plus OR Institute) complete all as specified and directed. |
| 119 | Supply and fix electronic meters temper proof LCD display with polycarbonate cover 3 Phase, 415 volt, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time,current reading, load, PF, voltage and KWHcomplete all as specified and directed. |