| Sl. No. | Item Description |
| 1 | Taking down chowkhat or frame (without taking off shutter from the frame)not exceeding 1.5 Square Metre each , removing from the site including Cutting holes exc 150 Sq.cm but n.exc 400 Sq.cm in super facia area into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required complete all as specified and as directed. |
| 2 | Taking down chowkhat or frame (without taking off shutter from the frame) exceeding 1.5 sqm and not exc 4.00 sqm each , removing from the site Including Cutting holes exc 150 Sq.cm but n.exc 400 Sq.cm in super facia area into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required complete all as specified and as directed. |
| 3 | Taking down trellis work (Jafri),including battens in trellis (posts and rails) complete all specifiedanddirected . |
| 4 | S&F Mild steel door shutter with MS angle iron shutters frame 35 mm X 35 mm X 5 mm in two panel covered with 1.25 mm thick MS plain black sheet welded to shutter with 2 Nos sliding door bolt of 16 mm dia300 mm long with locking arrangement, 2 Nos of tower bolt of200 mm longincluding MS angle iron frame 40 mm x40 mmx 5 mm as in chowkhat with 6 Nos hold fast of flat iron 30mm X5 mm ,200 mm long with bottom flat iron of size 30mmx5mm,diagonally bracing of 30 mmX5 mm and 100 mm size4 Nosbutt hinges including necessary cutting, welding, binding as required with two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces complete all as specifiedand as directed.[Single shutters of approx width 0.7 to 1.2 m andht 1.8 to 2.10 M.] |
| 5 | S&F framed work such as grills gratings,sunshed cover fixed with nut bolts incl,cutting drilling holesetc., with ends of bars shouldered and/ or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed baluster, walk ways, railings, framedwork or water tanks and similar work conforming to Fe 290Gde E 165 complete all as specified and directed. |
| 6 | S&F Solid PVC door frame of size 50mmX47mm made out of 5mm single side prelam PVC sheet used instead of plain colour PVC sheet (edges will be moulded with prelam sheet) reinforced with MS square tube, suppling & fixing in opening as per specification complete all as specifiedand as directed |
| 7 | S&F factory made solid PVC moulded door shutterwith wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6mm raised panel design with 5 mm thick moulded PVC sheet on the front face &5mm prelam PVC sheet on back face, supplying & fixing in frame at site complete all as specifiedand as directed |
| 8 | S&F fixed type ventilators aluminium powder coated of frame size 50.80X 25.40mm,1.5 mm thick will be fixed with louvers with 4mm thick frosted glass with rubber gasket and aluminium beading ,stainless steel wire mess 0.30 mm dia and width of aperture 1.45mm to be fixed over louvers portion onlyincluding necessarycutting holes on wall and fixing arrangements complete all as specifiedand as directed (Al. section thickness 1.20 mm } |
| 9 | S&F aluminium windowssliding type three track powder coated consisting of frame bottom with gutter of sizemin 92.34 X 31 mm,sideand top of size min 92.34X29.70, shutters vertical 39X18 mm,shutter top &bottom of size min 18X39 mm ,shutter interlock min size 39X18 mm with rollers and conceled locking arrangements with 4 mm thick tintedglass with rubber gasket,brush and aluminium beading ,stainless steel wire mess 0.30 mm dia and width of aperture 1.45 mmetcincluding necessarycutting holes on wall and floor complete all as specifiedand as directed (Al. section thickness 1.20 mm } |
| 10 | S&F 105 mm X 60 mm sizepressed steel frames for door with one or morerebatesincluding necessary Supply and fixing lugs, hinges, lock strike plate etc including one shop coat of red oxideprimerincluding M&L PCC 1:3:6 type C-0 using 12.5 mm graded store aggregate for filling in pressed steel frame complete all as specified and as directed |
| 11 | S&F 125 mm X 60 mm sizepressed steel frames for door with one or morerebatesincluding necessary, Supply and fixing lugs, hinges, lock strike plate etc including one shop coat of red oxideprimer M&L PCC 1:3:6 type C-0 using 12.5 mm graded store aggregate for filling in pressed steel frame complete all as specified and as directed |
| 12 | M&L second class hardwood in scantlings , timber clean sawn framed and fixed including dismantling unframed timber scantlings 40 sq. cm & over in section, in any position. .including preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer Complete all as specified and directed. |
| 13 | S&F 30 mm thick factory made flush shutters, solid core construction, with block board core and plywood facepanels, commercial type on both sides, including preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer Complete all as specified and directed. |
| 14 | S&F 2nd class HW factory made glazed and skeleton shutters 35 mm thickopen rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chemfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, cla-use 8.24 (a); for doors supplied and fitted to chowkats including preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer Complete all as specified and directed. |
| 15 | S&F for Extruded aluminium alloy handle of 150 mm size fabricatedtype, anodised complete all as specified.. |
| 16 | S&F for aluminium anodised barrel tower bolt of 150mmof extruded section complete all as specified. |
| 17 | S&F 100mmButt hinges, extruded aluminium aloy with galvanised mild steel hinge pin, anodised and fixed |
| 18 | S & Fdoor stopper of aluminium alloy body and tongue 150 mm long , anodised fixed in door with screws etc. |
| 19 | S&F 150 mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete. |
| 20 | S&F Aluminiumy alloy, anodised, sliding door bolts 300mm length ,with hasp staple (16 mm dia bolt type )and fixing clip of sheet cast or extructed sections and fixing boltand slidingbolts of extructedsectionsor cast aluminium alloy and fixed, complete all as specified and directed. |
| 21 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide all as specified and directed. |
| 22 | S&F galvanised mild steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.45mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 23 | M&L forRaking out joints/ pointing in cement mortarto squared rubble masonry, coursed or uncoursed complete all as specified and directed. |
| 24 | Taking down cement plaster on brick work or stone walls, etc incl raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 25 | M&L two coat cement plaster on brick / concrete/ stone surfaces ,first coat 15mm thick CM 1:6 and second coat cement plaster 5mm thick in CM 1:4 with WPCfinished even and smooth without using extra cment. (WPC will be paid seperately under respective item). |
| 26 | M&L for 15 mm thick rendering in cement mortar (1:6) on brick / concrete/ stone surfaces finished even and smooth without using extra cement with including taking down of existing cement or cement lime plaster complete all as specified and as directed. |
| 27 | M&L for rendering 5 mm thick in Cement Mortar (1:3) on ceiling finished even and smooth without using extra cement with including taking down of existing cement or cement lime plaster complete all as specified and as directed. |
| 28 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 29 | M &L for Brickwork with subclass \"B\"bricks, straright or curved on plan exc 6m mean radius built in Cement mortar 1:6 complete all as specified and directed. |
| 30 | M&L for Brickwork with old size subclass \"B\" bricks, straight or curved on plan in half brick thick wall built in CM 1:4 complete all as specified and directed. |
| 31 | M&L for 15 mm thick rendering in cement mortar (1:4) on brick / concrete/ stone surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 32 | M&L for preparation of the newly plastered surfacesof wall & applying3 coats of white wash on wall surfaces complete all as specified and directed. |
| 33 | M&L for water based premium acrylic smooth exterior emulsion of approved colour with silicon additive excellent dirt pickup resistance with low VOC less than 50, Antifungal/ Anti Algai properties in two coats not less than 1.79 litre(undiluted)/10 Sqm diluted with water as per manufacturer\"s instruction over and including one coat of exterior primer over and including 1mm thick wall care putty in two layers on new plastered surface complete all as specified and directed. |
| 34 | M & L for two coat of acrylic emulsion paint over a coat of 1mm thickwall care putty in two layers on new plastered surfaces on wall incl. preparation of surfaces complete all as specified and directed. |
| 35 | M&L for preparation of the newly plastered surfacesof ceiling & applying3 coats of white wash on ceiling surfaces complete all as specified and directed. |
| 36 | M&L for one coat of white wash on old decorated surface of ceiling ncluding preparation of old surface i.ebrooming down with steel wire brushes scraping downmoulds moss and efflorescent salts and treating oil and greasy spots, removing of nails, making good holes , craks etc and washing floors, cleaning glass , joinery , electric fitting, etcall as specified and directed. |
| 37 | M&L for Two coat of white wash on old decorated surface of walls including preparation of old surface i.ebrooming down with steel wire brushes scraping downmoulds moss and efflorescent salts and treating oil and greasy spots, removing of nails, making good holes , craks etc and washing floors, cleaning glass , joinery , electric fitting, etcall as specified and directed. |
| 38 | M&L for complete removal of existing treatment and applyingwall care whiteputty 1mm thick in two layers for levelling the surfaces of walls and applying two coat of acrylic emulsionover and includinga coat of interiorprimer incl. preparation of surfaces ofwallscomplete all as specified and directed. |
| 39 | M&L Complete removal of existing treatment and applied for water based premium acrylic smooth exterior emulsion of approved colour with silicon additive excellent dirt pickup resistance with low VOC less than 50, Antifungal/ Anti Algai properties in two coats not less than 1.79 litre(undiluted)/10 Sqm diluted with water as per manufacturer\"s instruction over and including one coat of exterior primer over and including 1mm thick wall care putty in two layers on oldplastered surface complete all as specified and directed. |
| 40 | S&F roof mild steel trusses ( Framed), trusses purlins, crane ganttires, rails and fastenings and heavy brackets framing ( Beams, tee, angle, channel or Flat Section) including distance pieces, cleats etc with round / rectangular/ square hollow mild steel tube section Fe 410-w (Gde-250 quality-A)complete all as specified and directed. |
| 41 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick, trapozoidal patternof any colour having tensile strength of 550 Mpa as in roof covering/cladding in wall, fixed with self tapping screws including dismantling plain or corrugated asbestos sheeting , any gauge, thickness complete all as specified and directed. |
| 42 | S&Fin repair 25mm dia stainless steelcurtain rod not less than 0.70mm thick including fixing of sufficient brackets ( minium 2 nos at every 1.50m length) & end Knobs complete all as specified and directed . |
| 43 | S&F GI tubing 15 mm bore medium grade with all fittings fixed to walls and ceilings or laid in floors including taking down 15 mm diaGI tubing and connections complete all as specified and directed |
| 44 | S&F 20 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors incl fittings and the holes in walls and floors shall be made by drilling with drill or jumper and not by dismantling the brick/concrete. After fixing holes shall be made good with CM 1:3 properlyincluding taking down 15 mm diaGI tubing and connections complete all as specified and directed complete all as specified. |
| 45 | S&FGI tubing 20 mm bore medium grade with all fittings fixed to walls and ceilings or laid in floors including taking down 20mm diaGI tubing and connections complete all as specified and directed |
| 46 | Cutting chases, pinning in, in brick wall making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring etc. and making good, in cement mortor 1:3 cutting not exceeding 10cm girth complete all as specified and directed. |
| 47 | S&F in repair for 110mm dia PVC(SWR)pipes single socketed, in any length with rubber ring joints,fixed to walls complete all specified. |
| 48 | S&F in repairfor 75/90 mm dia PVC(SWR)pipes single socketed, in any length with rubber ring joints,fixed to walls. complete all as specified . |
| 49 | S&F in repair for 75/90 mm dia PVC(SWR)pipes single socketed, in any length with rubber ring joints,laid in trenches or in floors complete all as specified . |
| 50 | S&F in repairfor 110mm dia PVC(SWR)pipes bends any radious \ complete all as specified and directed. |
| 51 | S&F in reapir for 75 /90 mm dia PVC(SWR)pipes bends any radious. complete, complete all as specified and directed. |
| 52 | S&F in reapir for 110mm dia PVC(SWR)pipes junction,single (single T/Y ) equal or unequal any radious.with acces door, complete all as specified and directed. |
| 53 | S&F in reapir for mm dia PVC(SWR)pipes junction,single (single T/Y ) equal or unequal any radious.with acces door, complete all as specified and directed. |
| 54 | S&F in reapir for 110mm dia PVC(SWR) vent cowl, complete all as specified and directed. |
| 55 | M&L in repairfor 75 mm dia of out letPVC (SWR) floor trap plain withCP grating including jointing with solvent cement complete all as specified and directed. |
| 56 | S&F for in repairs 15mm angle cock chromium plated,cast copper alloy, with brass ceramic disc spindleand capston heads,scewed down high pressure, with or without lettered \"hot\" or Cold\" with long srewed shanks and flynuts, srewedfor iron pipe fixed and complete all as specified and directed. |
| 57 | S&F for 15mm ,bib tapFancy type long body chromium plated,cast copper alloy, with brass ceramic disc spindle and capston heads,scewed down high pressure, with or without lettered \"hot\" or Cold\" with long srewed shanks and flynuts, srewedfor iron pipe fixed in repair and complete all as specified and directed. |
| 58 | S&F for shower rose brass chromium plated without swivel joints, 100 mm in size including fixing to steel pipe complete all as specified and directed fixedin repairs, complete all as specified and directed. |
| 59 | S&F for in repairs Brass CP WHB mixer for mixing hot & cold water screwed down for 15mm bore iron pipe complete all as specified. |
| 60 | S&F for in repairs Brass CP Wall mixer for mixing hot & cold water screwed down for 15mm bore iron pipe complete all as specified. |
| 61 | S&F for in repairs Soap dish of CP fixed with pvc rawal plugs and screw, complete all as specified and directed. |
| 62 | S&F for in repair CP tubular towel rail D type 20mm dia and 60cm long complete all as specified and directed. |
| 63 | S&F for peg set of six S.S.fixed to wall with PVC plugs and screw, complete all as specified and directed. |
| 64 | Supply only15mm dia PVC connection with PTMT nuts of length 450 mm, complete all as specified and directed. |
| 65 | S & F in repair Rotational moulded poly-ethylene multilayer water storage tanks (cylinderical vertical with closed top) 500 litres capacity, triple layer in construction white in colour hoisted and fixed in positionincluding dismantaling of old tank with all fittings complete all as specified and directed. |
| 66 | S&FPVC float valve assembly including assessories with float valve 20mm diacomplete all as specified and directed. |
| 67 | S&F for in repair gun metal globe /valve with iron wheel head screwed both ends for iron pipe of 20mm bore, complete all as specified and directed. |
| 68 | S&F for sinks madeout of stainless steel 1 mm thick kitchen or laboratory with ;plugs, washers, and waste pipe including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets, and connecting union to pipe overall size 495 mm x 420 mm with bowl size410 mmx 330 mm x 160 mm complete all as specified and directed fixed in repair. |
| 69 | S&F in repair Stainless steel kitchen plate rack minimum 1mm thickof size 31\" X 30\" X 8\" complete all as specified and directed. |
| 70 | S&F in repairBevelled edge looking mirror of size 600x450 selected quality glass mounted5mm thick AC building board or commercial plywood andfixed to wooden plug with chromium plated screws and cup washer all as specified & directed. |
| 71 | M&L for treatement for sunken portion is as follows :- (a) Demolition of lean concrete and other type of filling in sunken portion & cleaned the sunken portion incl vertical wall surface complete as directed. (b) M&L providing 12mm dia holes of 40mm deep @ 200mm c/c at the junction of beam and columns as co-ordial points for inserting/ pouring cement slurry with dr fixit groutong compound by pressure grouting for sunken floors of toilet including sealing the holes with CM 1:3(c) M&L for water proofing plaster for sunken portionin CM 1:3, 20 mm thick in two coats with water proofing compound at the rate of 200 ml per 50 Kgof cement and finishing the surface even and smooth without using extra cement.(d) M&L for applying two coats of Dr fixit compound suitable for sunkun treatment as per manufacturer instructions over vertical surfaces and floors of sunken of toilet including cleaning of surfaces. (e) M&L for PCC 1:5:10 type D2 using 40 mm graded stone aggregate as in filling (sunken portion)(f) M&L for PCC 1:2:4 type B0 using 12.50 mm graded stone aggregate, mixed with WPC @ 200ml per 50 kg of cement, as sub base, 75mm thick on top. Note :- Above quoted rate includes:-(a) Test again of water tightness by pounding for 72 hours & rectify defects if any till total elimination of defect.(b) The sunken portion shall be tested for leakage / seepage / dampness by ponding with water for 72 hours. In case any defect is noticed the portion shall be grouted with Dr fixit suitable chemical & tested again. The process of grouting and testing shall be repeated till leakage / seepage / dampness is eliminated (c) Horizontalflat area to be measured. |
| 72 | M&L for vitreous china squatting pan, orissa pattern sise 580x440mm white with integral foot rest (excluding flushing cistern) including vitreous china ‘P’ or ‘S’ traps connection to trap and to flushing pipe to complete fixed in repairs and making good to floor, complete all as specified and directed. |
| 73 | S&F for in repairsofvitreous china wash basin, white, flat back, size 550 x 400mm Including waste coupling ,waste pipe and labour for fixing pillar tap ,pvc connection but including cutting for and pinning in ends of and including brackets complete all as specified and directed. . Note : Pillar tap andPVC connection will be measured paid separetly. |
| 74 | S&F for in repair PVC valveless syphonic action dual flush type (5/10 ltr) flushing cistern low level white with inlet ball valve,float end handle handle including bracket complete of capacity 10 litres, complete all as specified and directed. |
| 75 | Dismantiling of stone slabs and tiles (Kota stone etc.)of any discription or any thickness in floors, aprons, skirting, dado etc.laid bedded and pointed in any mortar complete all as specified and directed. |
| 76 | Dismantling floor, hearth or wall tilingof any description and in any positionincluding cement mortarbedding (but not backing) complete all as specified and directed. |
| 77 | Roughning sufaces of old concrete floor by picking , sweeping cleaning and washing down with water to remove dust etc. Complete all as specified and directed |
| 78 | M&L for non skid ceramic tiles, joint free, coloured tiles7mm to 8 mm thick (Square or rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set over and including 15 mm thick cement screed in (1:6) CM set and jointed in neat cement slurryand pointed in white or coloured cement to match with the colour of tiles complete all as specified and directed. |
| 79 | Ditto all same as item no 78 but as in skirtingfixed over and including 10 mm thick cement screed in(1:4) CM set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles complete all as specified and directed.with the colour of tiles complete all as specified and directed. |
| 80 | M&L for non skid ceramic tiles, joint free, coloured tiles7mm to 8 mm thick (Square or rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set over and including 15 mm thick cement screed in (1:6) CM set and jointed in neat cement slurryand pointed in white or coloured cement to match with the colour of tiles complete all as specified and directed. |
| 81 | M&L for digital glazed ceramic tiles, coloured tiles 300mm x 600mm x 7mm thickon vertical faces ie. as in skirting/dado etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles fix over and including 15 mm thick backing coat in cement mortar (1:4)completeall as specified and directed. |
| 82 | M&L for non skid ceramic tiles, joint free, coloured tiles7mm to 8 mm thick (Square or rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc set over and including 15 mm thick cement screed in (1:6) CM set and jointed in neat cement slurryand pointed in white or coloured cement to match with the colour of tiles complete all as specified and directed. |
| 83 | M&L Granite slab16 mm to 18 mm thick machine cut, bedded and joined withcementand pointed with white cement with admixture of pigment to match over and including 20 mm thick screed bedCM (1:3) .the shade of granite stone including cutting and polishing type as incill and jamb/skirting, steps cooking plateformsincludigng rounding off the exposed edges and polishing all asspecified and directed.. |
| 84 | M&L for prepolished/ mirror polished machine cut Kota stone slab 18 mm to 20 mm thick , as in flooring,laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, over and including screed bed or bedding layer of mortar 20 mm thick in cement mortar (1:3 ) complete all as specified and directed. |
| 85 | M&L formirror polished/prepolishedMachine cut kota stone single piece slab as in steps tread,windows cill,18-20 mm thick ,over and including 15 mm thick screed in CM(1:4) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing , polishing and rounding the edges complete all as specified and directed. |
| 86 | M&L Kota stone slab 12-15 mm thick mirror polished/ preposlished in skirting, steps riser etc over and including 10mm thick plater in CM (1:4) & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and directed. |
| 87 | M&L cement concrete 1 : 3 :6 type C-2 using 40mm graded stone aggregate as in plinth protection 75mm thick finishing cement concrete surfaces even & smooth without using extra cement including filling of construction joint with bitumenous sealing compound. |
| 88 | Demolition of cement concrete in any description and in any position not otherwise specially provided complete all as specified and directed. |
| 89 | M&L Plain cement concrete (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundations / mass concrete complete all as specified. |
| 90 | M & L PCC (1:2:4) Type Bo using 12.5 mm graded stone aggregate as levelling course/mass concrete complete all as specified and directed. |
| 91 | Demolition of RCC in anythicknes (reinforced cut as required to facilitate demolition ) complete all as specified and directed. |
| 92 | S&F for Mild steel TMT bars 10mm dia, and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality. |
| 93 | S&F for Mild steel TMT bars 6mm to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality. |
| 94 | M&Lreinforced cement concrete type A1 (1:1.5:3) using 20 mm graded aggregate slab support on walls beams and columns in floors , roofs , landing balconies deck slab etc complete all as specified and directed. |
| 95 | M&L use and waste formwork to soffits of suspended slabs such as roof slabs , floor slabs , landings and similar works , not exceeding 200 mm thick ( horizontal or sloping ) including slab edges for rough finishedsurfaces of concretecomplete all as specified and directed |
| 96 | M&L fir cement concrete ( 1:2:4) type B-1 (20mm graded agrregate) in lintels upto 1.5m clear span, cills, stes, seimic and other similar bands, plinth course, string course, lacing cours, arapets and railingsupto 60cm in height, coping, kneelers, apex stones, bed plates, kerbs, water througs and the like including wheathering slightly rounded or chamfered angle and throating complete all as specified and directed. |
| 97 | S&F forin repair 18 mm thickmarine plywood board interior grade with 1mm thickwhite mica lamilation one side and 1mm thick coloured mica on another sideas in cupboard , shelve and shutter etc fixed with screws complete all as specified and directed. |
| 98 | M&L for external teak wood for plywood for external teak wood lipping, 6mm thick, fixed with nails for 18/19mm thick marine plywood boards including preparation and policing complete all as specified and directed. |
| 99 | S&F for aluminium anodised barrel tower bolts of extruded section of 100mm size, complete all as specified and directed. |
| 100 | S&F for continuous (piano) hinges mild steel bright finish or electro galvanised width of width of flaps nexc 30 mm (when open), complete all as specified and directed. |
| 101 | S&F for extruded aluminium alloy handle of 100 mm size fabricatedtype, anodised.complete all as specified . |
| 102 | S&F for Hasp and staple safety type Aluminium anodised with MS hinge pin including bolt to hinge pin of 100 mm size sixed with screw complete all as specified . |
| 103 | S&F for magnate catcher of metal body and striking plate heavy duty includind fixed with screw, complete all as specified and directed. |
| 104 | S&F sheet glass shelf assembly consisting of 5.5mm thick glass shelf 12cm wide with chromium plated bracket and guard and railing 60cm long completed all as specified and directed |
| 105 | M&L for provn of water proofing roof treatment toRCC roof with approved modified membrane of weighing not less than 3kg/sqmcomprising with following items and all as specified:- (i) The surface of roof,parpet and gutters drain mouths etc over which water proofing treatment is to be applied shall be cleaned of all foreign matter such as fungus,mass dust etc by wire brushing and dusting.For cast iron drain and outlets a groove shall be cut as specified and directed.(ii) Oil based Bitumenprimer conforming to IS-3384-1986 @ 0.3 kgs per sqm to be applied on prepared surface till the surface is properly impregnated.(iii) Applyingone coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqm(iv) Laying of water proofing teratment of weight not less than 3 Kg / sqmAPP modified polymeric water proofing membrane composed of 100 micron (±10% ) high density polyethylene sheet ( HMHDPE) as center core, which is standwiched between high quality polymeric bitumen mix having softening , high heat resistance and cold flexible protected on either side with a thin thermo fusible HMHDPE film with side and laps 75 mm and 100 mm as per manufacture instruction etc.(v) Applyingone coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqmover the membrane (vi) A fillet of PCC (1:2:4) of 100x100mm shall be provided at all junctions of vertical and horizontal surfaces and wherever there is a change of dirction. The membrane should not be taken over at any steep turns and hence all corners/timers should be rounded and including M&L for cutting of grooves at wall all around 65mm deep 10mm wide for APP membrane to be laid in gap as required on site as directed by Engineer In Charge |
| 106 | M&L for cool roof tiles 7mm to 9mm thick 300mmX 300mm in size white/ plain in colour conforming to sun reflective Index (SRI) value minimum of 70 and including 15mm thick 1:3 Screed bed fixed with 3 mm spacers and jointsshall be filled with epoxy grout complete all as specified and directed. |
| 107 | M&L for provn of water proofing roof treatment toRCC roof with approved modified membrane of weighing not less than 3kg/sqmcomprising with following items and all as specified:-(i) The surface of roof,parpet and gutters drain mouths etc over which water proofing treatment is to be applied shall be cleaned of all foreign matter such as fungus,mass dust etc by wire brushing and dusting.For cast iron drain outlets a groove shall be cut as specified and directed.(ii) Oil based Bitumenprimer conforming to IS-3384-1986 @ 0.3 kgs per sqm to be applied on prepared surface till the surface is properly impregnated.(iii) Applyingone coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqm (iv) Laying of water proofing teratment of weight not less than 3 Kg / sqmAPP modified polymeric water proofing membrane composed of 90 micron (±10% ) high density polyethylene sheet ( HMHDPE) as center core, which is standwiched between high quality polymeric bitumen mix having softening , high heat resistance and cold flexible protected on either side with a thin thermo fusible HMHDPE film with side and laps 75 mm and 100 mm as per manufacture instruction etc. (v) Applyingone coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqmover the membrane (vi) Applying aluminium paint in two coat @ 100 gm/sqm in each coat on finished membrane surfaces complete all as specified and directedat site .(vii) A fillet of PCC (1:2:4) of 100x100mm shall be provided at all junctions of vertical and horizontal surfaces and wherever there is a change of dirction. The membrane should not be taken over at any steep turns and hence all corners/timers should be rounded and including M&L for cutting of grooves at wall all around 65mm deep 10mm wide for APP membrane to be laid in gap as required on site as directed by Engineer In Charge |
| 108 | M & L forPCC ( 1: 2: 4) type B-0 using (12.5mm graded stone aggregate) etcon roof top as a leveling course / paddingto maintainthe slope,finished the surfaces even and smooth without using extra cementetc. |
| 109 | Taking downof oldroof treatment of any description including mud phushka, lime, concrete,tiles , cement plaster, padding upto 30cm depth from roof surfaces etc including cleaning, brushing and watering to joints and grooves and throwing the same to a distance exc 250 mtr and n exc 500 mtr from the roof of height 3 to 9 mheight etc . |
| 110 | Supplying only liquid waterproofing compound complete all as specified and directed. |
| 111 | M&L rendering 10mm thick in cement mortar 1:4 mixed with and including water proofing compound @ 200ml per 50 kg bag of cement applied over roof slab ,complete all as specified and directed.Note : Water roofing comound shall be measured and aid seperately |
| 112 | S&Fchecken wire mesh 0.71 mm dia and aperture size 25mm fixed in position etc complete all as specified and directed. |
| 113 | Labour only for removal of unsound RCC by hammer chiseling or pneumaticchopper and exposing reinforcement all around includingproviding jacking up arrangement or temporary supports ofadequate strength to avoid any damage to the existing structure and removing rubbish to outside MD land complete all as specified as directed. |
| 114 | M & L for cleaning exposed rusted reinforcement in site with wire brushes and applying polymer based rust remover of make Dr fixit Rust Remover (Rust removing chemical) or \"Defroster\" or equivalent chemical as approved as per manufacturers instructions complete all as specified and as defected |
| 115 | Labour only for welding with new additional reinforcement bars as required of site i.e. where dia of existing bar is found reduced than the original size of bars complete all as specified and directed.Note: Reinforcement bars will be measured and paid separately under respective items here in before |
| 116 | M&L for priming the old and / or new steel reinforcement with one coat of Fosroc \"Nito Zinc primer\" or Dr Fixit epoxy zinc primer or equivalent as approved by brush applicationcomplete all as specified and directed. |
| 117 | M&L for hard drawn steel wire fabric cut to length bent to shape, dia of fabric 3 mm and aperture 50 mm, cover entire steel surface, not exceeding 4 kg per Sqm complete all as specified and directed |
| 118 | M&L for bounding the entire exposed surface with one coat of \"Fosroc Nitcobond SBR\" as permanufacturers instructions complete all as specified and directed |
| 119 | M & L for one layer of Fosroc spray for SL concrete 20mm thick (comprises composition1:2:1 plain cement concrete i.e. one part of cement two parts of fineaggregate and one part of 10mm and down size trap stone aggregate) mixed with sprayset SL 2 to 2.5 % weight of cement and 12.5 to 16.5 liter of water mixed as per manufacturers instructions an gunnting pressure nozzle with a delivery capacity of 2.5 kg Sqm over column beam roof slab and other similar work complete all as specified and directed.. |
| 120 | M & L for 10 mm thick rendering in cement mortar 1:4 over guniting concrete surface and finished the surfaces even and smooth or matching/ flushing with adjoining plastered surfaces . |
| 121 | M & L broken stone or boulders hard core of gauge n.exc 63mm deposited spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface complete all as specified and directed. |
| 122 | Moorum/red bajri filling in floors or pavings laid in layers n.exc 15cm thick spread levelled and rammed including watering |
| 123 | M&L Plain cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundations / mass concrete complete all as specified. |
| 124 | M &L for random rubble uncoursed well bounded bedded and solidly hearted in Cement mortar 1:6complete all as specified and directed. |
| 125 | Excavating in trenches in any type of soil , n exc 1.5 m wide and n. exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soil complete all as specified and as directed. |
| 126 | Returning, filling in, including spreading ,leveling, watering and well ramming in layers n. exc 25 cm with soil complete all as specified and as directed. |
| 127 | Removal of excavated material (soil) to a distance n. exc 50 m and depositing where directed at a level n.exc 1.5 mabove the starting point complete all as specified and as directed. |
| 128 | M&L PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in coping, kerb, haunching etc including necessary formwork complete all as specified and directed |
| 129 | M&L,precast cement concrete 1:2:4 type B1 using 20mm graded BT stone agregate including necessary form work as in manholes cover slab etc, set in cement mortar 1:4 complete all as specified and as directed. (Note :- Re-inforcement shall be measured and paid for separately under respective items of Sch \"A\" here in after) |
| 130 | Material and labour in repair providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade chemically treatedwith aproved colour, design & pattern as in foothpath, parks, lawns, drive ways or light traffic parking etc. of required strenght, thickness & size / shape, , laid in required colour & pattern over and including 30 to 50mm thick uniformly levelled surface ofstone dust cushioning, , filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra cementincluding dismantling of old unserviceable tile complete all as specified and directed. |
| 131 | M&L for cement concrete ( 1:2:4) type B-1 (20mm graded agrregate) in lintels upto 1.5m clear span, cills, stes, seimic and other similar bands, plinth course, string course, lacing cours, arapets and railingsupto 60cm in height, coping, kneelers, apex stones, bed plates, kerbs, water througs and the like including wheathering slightly rounded or chamfered angle and throating complete all as specified and directed. |
| 132 | Taking down copper/aluminium point wiring (light fan, socket or power) complete including fittings such as switch,sockets, c/rose, lamp holders, tube light fittings, sketch fitting , wooden boards, bell push, call bell, MCBs & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall floor etc. |
| 133 | Taking down main switch, DB/change over/VTPN, MCCB AC box of any capacity. |
| 134 | M&L for concealed point wiring with 1.5 Sqmm PVC-FRLSH insulated, sheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit,includingmodular metal flush boxes & modular white cover plate with frame as per site requirement all fittings such as tees, bends, elbows,etc. of External diameter 20mmall as per site requirements PVC insulated & sheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and directed. Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 135 | For one light, fanpoint controlled by one switch |
| 136 | For onecall bell point controlled by one push button switch. |
| 137 | For one5 Amp independent socket point controlled by one switch |
| 138 | For one 3 pin ,5 Amp socket point with other switch on the same board |
| 139 | For one light, point controlled by two wayswitch |
| 140 | M&L for concealed power point wiring with 2.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit,includingmodular metal flush boxes & modular white cover plate of suitable module with frame as per site requirement all fittings such as tees, bends, elbows,etc. all as per site requirements PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 2.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge .Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 141 | S&Fswitch, one way, 6 Amp 230, 1 module complete all as specified and directed. |
| 142 | S&F Modular switch, two way, 6 Amp 230, 1 module complete all as specified and directed. |
| 143 | S&F socket Modular 6 Amp-2/3 pin combined 2 module complete all as specified and directed. |
| 144 | S&F switch Modular, single pole, one way,16 Amp ,1 module 230 Voltcomplete all as specified and directed. |
| 145 | S&F socket modular 6/16 Amp, 2/3 pin combined ,2 module 230 Voltcomplete all as specified and directed. |
| 146 | S&F ceiling rose, surface backlite,three terminal complete all as specified and directed. |
| 147 | S&F Modularlamp holder insulated with back plate suitable for Angle/Batten fitting complete all as specified and directed. |
| 148 | S&F modular fan step regulator 120W2 modulecomplete all as specified and directed. |
| 149 | S&F modular bell push 6A ,1 modulecomplete all as specified and directed. |
| 150 | S&F call bellding dong230 Volt , single phase complete all as specified and directed. |
| 151 | Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 152 | S&F box type LED optic fitting1x9 Watt2 feet box type complete .Make:Havellls /Wipro/CG ll as specified and directed by Engr -in -Charge . MakeBajaj cat part No BCLSB10WH/ CG Cat par No LCTL-9-CDL or equivalent. |
| 153 | S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. |
| 154 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300MM sweep with, blades, and frame and louvers.(Initial Deficiency) |
| 155 | Taking down and refixing connecting electric water heater (Geyser 25 ltr) Incl supply and fixing of pvc pipe, fasterner complete all as specified and directed. |
| 156 | Taking down fan ,sealing cable end,dismantling blades and removing fan and bladesdeposited to mes store complete all as specified and directed. |
| 157 | S&F LED bulb 10 wattsuitable for angle / batten holder fitting complete all as specified and directed. |
| 158 | Supply and fixing ceiling fans with remote complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 159 | Taking down and refixing connecting electric meter SPup to 60 amp incl S & F suitable board close recessed type of suitable size complete all as specified and directed. |
| 160 | M&L concealed sub main wiring with two single core PVC FRLS insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size6 sqmm (for main current) drawn in & incl PVC conduitconduit less than 20mm dia ISI markedwith all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of01 Single core of size 6 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as specified and directed.Note: (i) cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.(ii)Two runs of single core for main current and one run of single core for earth continuity conductor & one run of PVC Casing-n-caping shall be measured as one unit length. |
| 161 | S&F testing and commissioning of MCB SP 6 Amp to 40 Amp 240 Volt 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed. |
| 162 | S&F testing and commissioning of MCB SP 63 Amp 240 Volt 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed. |
| 163 | –do- but SPN 40 Amps, 240 V complete all as specified and directed. |
| 164 | S&F sheet metal enclosureDB double door, IP-43 when MCBs to be used SPN, 8 way, 240 V with 200 Amps rated bus bar of suitable size complete all as specified and directed. |
| 165 | S&F double door metallic sheet metal enclosureDBdouble door(DPX-125 ) VTPN suitable for housing 63 MCCBas incomer 4 Way 415 Volts with 200 Amps rated bus bars complete all as specified and directed. |
| 166 | S&F MCCB 63 Amps 4 pole, suitable for 415 V breaking capacity 16 KA connected in wall/surface with wire and lugs complete all as specified and directed. |
| 167 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 168 | M&L for GI pipe bracket of size 40 mm diamedium gradeof length not less than 1.5 Mtr long and bent to a shapeincl fixingwallwith 02 Nos MSflate clampof suitable size incl nut bolt and washers complete all as specified and as directed. |
| 169 | M&L for provn of Earthing complete with galvanised steel earth plateelectrode, 600x600x6mm buried directly in ground (Earth pit not less than 2.25M deep below the GL) with top edge not less than 1.5 metres below ground level connected with galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steelall as shown in electric plate no 3 connected to earthing test point all as specified or indicated including testing on completion.Note :- (i) The rate quoted shall also deemed to include the cost of GI wire and protection pipe upto 7.5 Mtr beyond the earth plates electrode and also the costof the Test point. (ii) Joining of GI earth wire with pipe of the test point shall be done by using suitable cable lugs. |