| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within campus area as per direction of Engineer -In - Charge. |
| 2 | All kinds of soil. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead within campus area as per direction of Engineer -In - Charge. |
| 4 | Supplying chemical emulsion in sealed containers including delivery as specified. |
| 5 | Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 6 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : |
| 7 | Along external wall where the apron is not provided using chemical emulsion @75litres/ sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: |
| 8 | With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration |
| 9 | Treatmentofsoilunderexistingfloorsusingchemical emulsion © one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement: 2 Coarse sand) to match the existing floor: |
| 10 | With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 11 | Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : |
| 12 | With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 13 | Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth |
| 14 | 1:5:10 (1 cement : 5 coarse sand (zone-Ill) derived from naturalsources :10gradedstoneaggregate40mm nominal size derived from natural sources) |
| 15 | Providing and laying in position specified grade of reinforced cement concrete,excludingthecostofcentering,shuttering,finishingand reinforcement - All work up to plinth level : |
| 16 | 1:1.5:3(1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 17 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 19 | Foundations,footings,basesof columns,etc.formass concrete |
| 20 | Shelves (Cast in situ) |
| 21 | Lintels,beams,plinthbeams,girders,bressumersand cantilevers |
| 22 | Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete upto plinth level. |
| 23 | Thermo-Mechanically Treatedbars of gradeFe-500D or more. |
| 24 | Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete above plinth level. |
| 25 | Thermo-Mechanically Treatedbars of gradeFe-500D or more. |
| 26 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 27 | Cement mortar 1:6(1 cement :6 coarse sand) |
| 28 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 29 | Cement mortar 1:6(1 cement : 6 coarse sand) |
| 30 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 31 | Cement mortar 1:4(1 cement :4 coarse sand) |
| 32 | Providingandfixing 18mmthickgangsawcut,mirrorpolished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters,window sills,facias andsimilar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red |
| 33 | Area of slab upto 0.50 sqm |
| 34 | Area of slab over 0.50 sqm |
| 35 | Providing and fixing Ist quality ceramic glazed wall tiles of size 600x300mm or moreconforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 36 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202(PartI)non-decorative type,core of blockboardconstruction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 37 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 38 | 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws |
| 39 | Providingandfixingchromiumplatedbrass curtainrodhaving wall thickness of 1.25 mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete: |
| 40 | 25 mm dia |
| 41 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 42 | 250x16 mm |
| 43 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 44 | 200x10 mm |
| 45 | 100x10 mm |
| 46 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 47 | 100 mm |
| 48 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 49 | Providing and fixing to existing door frames. |
| 50 | 30mm thick FiberglassReinforcedPlastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at requiredplaces for fixing of fittings and polyurethanefoam (PUF)/ Polystyrenefoamtobeused asfillermaterialthroughoutthehollowpanel,casted monolithically withtestingparameters of F.R.P.laminate conformingtotable 3ofIS: 14856,completeasper direction of Engineer-in-charge. |
| 51 | Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws: |
| 52 | 35 mm thick shutters |
| 53 | withISImarkedM.S.pressedbutthinges bright finished of required size |
| 54 | Kiln seasoned and chemicallytreatedhollock wood |
| 55 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with: |
| 56 | 4.0 mm thick glass panes |
| 57 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. |
| 58 | Using M.S. angels 40x40x6 mm for diagonal braces |
| 59 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 60 | 25 mm thick |
| 61 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 62 | Providing and laying Vitrified tiles in floor in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 63 | Glazed Vitrified tiles Matt/Antiskid finish of size |
| 64 | Size of Tile 600 x 600 mm |
| 65 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 66 | Size of Tile 600x600 mm |
| 67 | Providing and laying full body vitrified tile in floor, skirting, windows sills and jambs etc of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.30 kg / sqm including grouting the joints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only. Laying of slab will be done with the help of notch trowel,wedge,clipsofrequiredthickness,vacuumcupsforlifting, leveling system and rubber mallet for placing the slab gently and easily. Size of tile 800x2400 mm of all colours and shades. |
| 68 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. |
| 69 | Single tee with door |
| 70 | 110x110x110 mm |
| 71 | Single tee without door |
| 72 | 110x110x110 mm |
| 73 | Bend 87.5° |
| 74 | 110 mm bend |
| 75 | 12 mm cement plaster of mix: |
| 76 | 1:6 (1 cement: 6 coarse sand) (including height up to 10 metre) |
| 77 | 15 mm cement plaster on rough side of single or half brick wall of mix: (including height up to 10 metre) |
| 78 | 1:6(1 cement: 6 coarse sand) |
| 79 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: |
| 80 | New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 81 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 82 | Two or more coats on new work |
| 83 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 84 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 85 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand andmanufacturerincluding applying additional coats wherever required to achieve even shade and colour |
| 86 | Old work (one or more coats) |
| 87 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 88 | One or more coats on old work |
| 89 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade |
| 90 | Old work (one or more coats applied @ 0.83 ltr/10 sqm). |
| 91 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (including height up to 10 metre) |
| 92 | With cement mortar 1:4 (1cement: 4 coarse sand) |
| 93 | Disconnecting damaged overhead/terrace PVC water storage tankof any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. |
| 94 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with“S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material including malba, all complete as per the direction of Engineer-in charge. |
| 95 | Orissa pattern W.C Pan of size 580x440 mm |
| 96 | Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge. (a) Internal Work- Exposed on wall |
| 97 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 98 | Nominal concrete 1:4:8 or leaner mix (including equivalent design mix) |
| 99 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within campus area as per direction of Engineer -In - Charge. |
| 100 | Demolishingbrickworkmanually/bymechanicalmeansincluding stacking of serviceable material and disposal of unserviceable material within campus area as per direction of Engineer -In - Charge. |
| 101 | In cement mortar |
| 102 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within campus area as per direction of Engineer -In - Charge. |
| 103 | Of area 3 sq. metres and below |
| 104 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : |
| 105 | Of area 3 sq. metres and below |
| 106 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 107 | For thickness of tiles 10 mm to 25 mm |
| 108 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 109 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within campus area as per direction of Engineer -In - Charge. |
| 110 | 100 mm dia pipe |
| 111 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within campus area as per direction of Engineer -In - Charge. |
| 112 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within campus area as per direction of Engineer -In - Charge. |
| 113 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 114 | W.C. pan with ISI marked white solid plastic seat and lid |
| 115 | ProvidingandfixingP.V.C.lowlevelflushingcisternwithmanually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 116 | 10 litre capacity - White |
| 117 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 118 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 119 | Semi rigid pipe |
| 120 | 40 mm dia |
| 121 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 122 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 123 | Rectangular shape 1500x450 mm |
| 124 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 125 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 126 | 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms. |
| 127 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. |
| 128 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litre with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. |
| 129 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall |
| 130 | 25 mm nominal dia Pipes |
| 131 | ProvidingandfixingChlorinatedPolyvinylChloride(CPVC)pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
| 132 | 15 mm nominal dia Pipes |
| 133 | 20 mm nominal dia Pipes |
| 134 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 135 | 20 mm nominal bore |
| 136 | 25 mm nominal bore |
| 137 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 138 | 45 cm length |
| 139 | 15 mm nominal bore |
| 140 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
| 141 | 150 mm diameter |
| 142 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting hole and making good the walls etc. : Internal work – Exposed on wall. |
| 143 | 20 mm dia. nominal bore |
| 144 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work): |
| 145 | 20 mm nominal bore |
| 146 | 25 mm nominal bore |
| 147 | Providing and placing on terrace (at all floor levels) polyethylene water storagetank,IS : 12701marked,withcoverandsuitablelocking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 148 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 149 | 15 mm nominal bore |
| 150 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 151 | 15 mm nominal bore |
| 152 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 153 | 15 mm nominal bore |
| 154 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 155 | 15 mm nominal bore |
| 156 | Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. |
| 157 | Providing and fixing PTMT bib cock of approved quality and colour. |
| 158 | 15 mm nominal bore, 86 mm long, weighing not less than 88 gms |
| 159 | Providing and fixing PTMT grating of approved quality and colour. |
| 160 | Circular type |
| 161 | 125 mm nominal dia with 25 mm waste hole |
| 162 | Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements. Weighing not less than 106 gms. |
| 163 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. |
| 164 | 15 mm nominal bore. Weighing not less than 32 gms. |
| 165 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : |
| 166 | Inside size 90x80 cm and 45 cm deep including C.I. coverwithframe(lightduty) 455x610mminternal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : |
| 167 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 168 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality |
| 169 | L D- 2.5 |
| 170 | Rectangularshape 600x450mminternal dimensions |
| 171 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : |
| 172 | For fixed portion |
| 173 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 174 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 175 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 176 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 177 | With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 178 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately). |
| 179 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. |
| 180 | Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 181 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 182 | Providing & fixing false ceiling at all heights withGRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanized @ 120 gram per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600 mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 183 | With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles. |
| 184 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as perspecifications and direction of Engineer- In-charge complete in all respect. |
| 185 | SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 186 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used)as per specifications and directions of Engineer-in-charge.Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75 mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2). |
| 187 | 25 mm average thickness. |
| 188 | After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod pf approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS:16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for: (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3(ii) Sites with structure height more than 20m for all wind speeds. |
| 189 | Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. |
| 190 | Using R2 series with frame (70mm & above) x (40mm & above) & both glazed and fly screen sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 meter). |
| 191 | Fixed window / ventilator with mullion / transom. |
| 192 | Using R2 series with frame (39mm & above ) x (39mm & above) & mullion (39mm & above) x (60mm & above). (Height upto 1.2 meter) |
| 193 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. |
| 194 | 1.0 mm thick. |
| 195 | Cost of total DSR Items = Rs. 1,14,89,230.42 A Deduct GST Factor on DSR-2023 Items @ total of DSR rates - 0.973 of DSR rates) i.e. 1,14,89,230.42 - 0.973 A = Rs. 3,10,209.22 |
| 196 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, and C.I. trap for standard urinal with vent arm with operating and other couplings in C.P.brass: 50 mm dia other couplings in C.P. brass, including cutting and making good the walls and floors wherever required. |
| 197 | Providing and Fixing on wall face unplasticidsed Rigid PVC rain water pipes confirming to IS: 13592 Type-B,including jointing with seal ring confirming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes with 6 kg/cmxcm Pressure.110 mm diameter |
| 198 | Extra for mixing water proofing compound (LW+) confirming to IS:2645 @ 500 ml/bag of cement in cement mortar and slurry used for fixing floor tiles of any size |
| 199 | Providing and fixing CPVC brass elbow( one side threaded and another side plain ) in existing pipe linewith CPVC solvent & testing of joints complete as per direction of Engineer in Charge.External work, 20 mm nominal dia |
| 200 | Providing and fixing CPVC brass elbow( one side threaded and another side plain ) in existing pipe linewith CPVC solvent & testing of joints complete as per direction of Engineer in Charge.External work,25 mm nominaldia |
| 201 | Providing and fixing CPVC brass reducer elbow (one side threaded and another side plain )in existing pipe linewith CPVC solvent & testing of joints complete as per direction of Engineer in Charge.External work,25x15 mm nominaldia |
| 202 | Providing and fixing CPVC brass reducer elbow (one side threaded and another side plain )in existing pipe linewith CPVC solvent & testing of joints complete as per direction of Engineer in Charge.External work,20x15 mm nominaldia |
| 203 | Providing and fixing CPVC brass tee (one side threaded and another side plain ) in existing pipe linewith CPVC solvent & testing of joints complete as per direction of Engineer in Charge.External work20x15x20 mm nominaldia |
| 204 | Providing and fixing CPVC brass tee (one side threaded and another side plain ) in existing pipe linewith CPVC solvent & testing of joints complete as per direction of Engineer in Charge.External work25x15x25 mm nominaldia |
| 205 | Providing and fixing CPVCreducer brass coupling(one side threaded and another side plain )in existing pipe linewith CPVC solvent & testing of joints complete as per direction of Engineer in Charge.External work,20x15 mm nominaldia |
| 206 | Providing and fixing CPVCreducer brass coupling(one side threaded and another side plain )in existing pipe linewith CPVC solvent & testing of joints complete as per direction of Engineer in Charge.External work,25x15 mm nominaldia |
| 207 | Providing and fixing CPVCreducer brass coupling(one side threaded and another side plain )in existing pipe linewith CPVC solvent & testing of joints complete as per direction of Engineer in Charge.External work,25x20 mm nominaldia |
| 208 | Providing and fixing CPVC union in existing pipe linewith CPVC solvent & testing of joints complete as per direction of Engineer in Charge.External work20 mm nominaldia |
| 209 | Providing and fixing CPVC union in existing pipe linewith CPVC solvent & testing of joints complete as per direction of Engineer in Charge.External work25 mm nominaldia |
| 210 | Attending repair work with hanging Jhula including necessary ropes, safety belt, helmate, safety shoes etc on the exterior side forhigh rise buildings up to height of 35 meters with making necessory arrangement for hanging Jhula hanging with appropriate ropes locking/fixing arrangemens at Terrace capacity for 02 to 03 persons for repair of water supply and sewage /drainage line( Cost of Item or materials for the execution of job in water supply and sewage /drainage line will be paid separately) |
| 211 | Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer, labouretc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150 mm dia upto 600 mm (8 Hrs working ) |
| 212 | Providing and fixing white vitreous china under counterwash basin ofSize: 520 x 450 x 200 mm of approved makewith 32mm CP Brass Waste of standard pattern including making all connections : Italian collection all completeas per direction of engineer in charge. |
| 213 | Providing and fixing Pressmatic valveof approved quality conforming to IS standards and weighing not less than 500 gms. 15mm nominal dia |
| 214 | Providing and fixing SS hanger (set of pegs) heavy dutyof approved quality of size 450mm. |
| 215 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 800x2400 mm |
| 216 | Credit for MS section like angle, tee, flats, grill etc. |
| 217 | Credit for SCI/CI pipe |
| 218 | Credit for G.I. pipe |
| 219 | Credit for CP fittngs etc |
| 220 | Providing and fixing double glazed hermetically sealed tougnened glass in existing windows, ventilators, frameand partitionetc. with 5 mm thick tougnened glass both side, having 12 mm air gap (5-12-5 mm) , including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant)all complete i/c removing/dismantling of old broken glass etc as per specifications, drawings and direction of Engineer-in-charge complete. (Including height up to 10.0 mtere) |
| 221 | Providing and placing in position up to floor five level micro concrete of approved brand and manufacturer which shall be cement based prepacked single component chloride free, no shrink, free from self compacting, ready to use after mixing water in soecified proportion as per manufacturer specification and direction of engineer-in-charge (payment under this item shall be made only after prepare wet curing has been done and surface has been satisfactroly evaluted by sundries/taping with blunt a metallic instrument) (including height up to 10.0 metre) |
| 222 | Providing and fixing white vitreous china table top/counter topwash basin of catageryJDS-WHM-25907N of Jaquar make or equavalent series of make Euronics, hindware, Parryware with 32mm CP Brass Waste of standard pattern including making all connections : Italian collectionas per direction of engineer in charge Table Top Basin, In White Matt ofSize: 530x420x140 mm, Shape - Rectangular as per direction of engineer in charge all complete |
| 223 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet ofSize: 370x665x750 mm of catagery CNS-WHT-853S220SPPSM of Jaquar make or equavalent series of make Euronics , hindware, Parrywareincluding integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. |
| 224 | Providing and fixingsingle lever Basin mixture of catagery KUP-35005BPM of Jaquar make or equavalent series of make Euronics , hindware, Parryware including painting of fittings and brackets, cutting and making good the walls wherever required:- |
| 225 | Providing and fixing 600 mm Stainless steel H -type handle onexisting toughtend glass shutteras per thedirections of engineer-in-charge . |
| 226 | Providing and fixing C.P. brass angle valve With Wall Flange for basin mixer and geyser points of catagery FON-40053 of Jaquar make or equavalent series of make Euronics, hindware, Parryware, 15mm nominal bore |
| 227 | Providing and fixing C.P. brass bib cock With Wall Flange of catagery FON-40037 of Jaquar make or equavalent series of make Euronics, hindware, Parryware, Euronics15mm nominal bore |
| 228 | Providing and fixingCPHealth Faucet (ABS Body) with 8mm Dia, 1.0 Meter Long Spirochrome flex tube & Wall Hook ofcatagery ALD-587of Jaquar make or equavalent series of make Euronics, hindware, Parryware,all complete, as per direction of engineer in charge |
| 229 | Providing and fixing Soap Dispenser with Glass Bottle of catagery ACN-1135Nof Jaquar make or equavalent series of make Euronics, hindware, Parryware, Euronics all complete, as per direction of engineer in charge |
| 230 | Providing and fixing Soap Dish Holder of catagery ACN-1131Nof Jaquar make or equavalent series of make Euronics, hindware, Parrywareall complete, as per direction of engineer in charge |
| 231 | Providing and fixing Toilet paper/ Roll Holder with Stainless Steel Flap of catagery ACN-1153Sof Jaquar make or equavalent series of make Euronics, hindware, Parryware all complete, as per direction of engineer in charge |
| 232 | Providing and fixing Towel Rack 600mm Long Without Lower Hangers but with 3 hooks, Stainless Steel of catagery ACN-1181FHSof Jaquar make or equavalent series of make Euronics, hindware, Parryware all complete, as per direction of engineer in charge |
| 233 | Providing & fixing of 06mm thick both side High pressure Interior compact laminate of approved quality & make ( Century, Exteria, fundermax, Merino, Durian, Greenlan Trespa). These are EN 438-Part 6 complying panels which are manufactured by high pressure and temperature in a hot press. The core of the panel consists of desired numbers of imported, long fibre virgin kraft papers, impregnated with specially formulated double hardened Phenolic resin and another top layer of imported virgin Blue wool scale passed, decorative paper layer impregnated with melamine resin. The panels are flame retardant type class 1 as per BS:476 Part 7, ASTM E84 and EN 438-Part 6. HPL panels have a tested Flexural Modulus of ≥ 11,000 MPa and Flexural strength of ≥100 MPa which makes the product enormously sturdy from inside. This product shows no distortion in extreme climatic changes such as from -20°C to +80°C or from dry climate to a relative humidity in excess of 85% - 90%. HPL panels pass a 3000 hours artificial weathering and are rated with a 5 for Grey scale rating & 7/8 for Blue wool rating. This material has antibacterial and anti fungal properties and density is 1.45gm/cm3 with 10 years warranty the cladding system will be installed on aluminium box section 25x38x1.5mm (P/F aluminium box section shallbe paid in respective item). Installation will be done via rivets/adhesive and 3M tape complete as per direction of engineer-in-charge. (including height up to 10 metre) |
| 234 | Providing & fixing of 06mm thick both side High pressure Exterior Grade laminate of approved quality & make of Century, Exteria, fundermax,Durain, Merino, Greenlam, Trespa). These are EN 438-Part 6 complyingpanels, which are manufactured by high pressure and temperature in a hot press. The core of the panel consists of desired numbers of imported, long fibre virgin kraft papers, impregnated with specially formulated double hardened Phenolic resin and another top layer of imported virgin Blue wool scale passed, decorative paper layer impregnated with melamine resin. The panels are flame retardant type class 1 as per BS:476 Part 7, ASTM E84 and EN 438-Part 6. Poly-methyle methacrylate UV protecting films are provided at the top of the Deco layer for optimum UV protection (passes 1500Hrs). HPL panels have a tested Flexural Modulus of ≥ 11,000 MPa and Flexural strength of ≥100 MPa which makes the product enormously sturdy from inside. This product shows no distortion in extreme climatic changes such as from -20°C to +80°C or from dry climate to a relative humidity in excess of 85% - 90%. HPL panels are equipped with a maximum possible weather resistance at extreme oceanic climates as it has duly passed the salt spray test conducted for 500 Hours. HPL panels pass a 3000 hours artificial weathering and are rated with a 5 for Grey scale rating & 7/8 for Blue wool rating. Density is 1.45gm/cm3 with 10 years warranty the cladding system will be installed on aluminium box section 25x38x1.5mm (P/F aluminium box section shallbe paid in respective item) with aluminium POP rivets are being used for fastening purpose (with appropriate sliding and fixed holes). complete as per direction of engineer-in-charg. (including height up to 10 metre) |
| 235 | Extra for CNC cutwith required design and patternin06mm thickHigh pressure laminate (Exterior/interiorGrade)allcomplete as per direction of engineer-in-charg. |
| 236 | Providing and fixing in wall lining of 14mm thick WPC louversPre-laminated one side decorative lamination and other side balancing lamination, with necessary fixing arrangement and screws etc. all complete as per direction of engineer in charge . (including height up to 10 metre) |
| 237 | Providing and fixingPremium qualityGRC cobbles of size not less than 150x150x22 mm of approved design and shape laid in required colour and patternin footpath & courtyard etc jointed with neat cement slurry mixed with pigment to match the shade of tiles, including cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 238 | Providing and fixingblinds of contour shape sheer series of Vista make or equivalanet make of required colour, shape and size all complete as per direction of engineer in charge. |
| 239 | Providing and fixing DORMA automatic sensordoor accessories for clear passage width 1000-1500mm clear passage height 3000mm panel weight double sliding 100 KGs x 2. (Clear span of officeup to 5.50 metre)1. Glass clamping rail 1000 mm - 2 Nos.2. Floor guide for glass door - 2 Nos. 3. ECW 8-2 Nos silver (For inside and outside).4. Light barrier SBK 111-1 pair5. Remote6. UPS and Digital Locking arrangement all completed including installation as per direction of Engineer-in-charge |
| 240 | Providing and fixing false ceiling system with 100mm vide Aluminium strips of approved texture in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sectionsincluding, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc complete as per direction of engineer-in-charge. (including height up to 10 metre) |
| 241 | Making Hatching of required design and pattern including colour logo etc on Toughened glass all complete as per direction of Engineer in charge |
| 242 | Providing and fixing 18mm thick onesides Pre-laminatedand other sideHDHMR board of approved brand and shade with suitable full threaded steel screws etc. in partitions, boxes, shelves, racks and cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge (Note: Fittings to be paid separately). |
| 243 | Providing and fixing 6mm thick prelainated both side HDHMR board of approved brand and shade with suitable full threaded steel screws etc. on the backing of racks, drawer, cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in charge. |
| 244 | Providing and fixing Premium qualityGRC wall tiles (thickness to be specified by the manufacturer) , of approved make and colours, shadesas approved by Engineer-in-Charge, in wall linning, skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete (including height up to 10 metre) |
| 245 | Providing & fixing 2mm thick transparent acrylic sheet fixed with putty or silicon in steel doors, windows, clerestory windows, all complete as per direction of Engineer-in-charge. (including height up to 10 metre) |
| 246 | Electrical |
| 247 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 248 | Group C |
| 249 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 250 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 251 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 252 | Group B |
| 253 | Group C |
| 254 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 255 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 256 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 257 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 258 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 259 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 260 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 261 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 262 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 263 | Group B |
| 264 | Group C |
| 265 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 266 | 3 x 1.5 sq. mm |
| 267 | 6 x 1.5 sq. mm |
| 268 | 9 x 1.5 sq. mm |
| 269 | 3 x 4 sq. mm |
| 270 | 6 x 4 sq. mm |
| 271 | 9 x 4 sq. mm |
| 272 | 3 x 6 sq. mm |
| 273 | 6 x 6 sq. mm |
| 274 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 275 | 20 mm |
| 276 | 25 mm |
| 277 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 278 | 20 mm |
| 279 | 25 mm |
| 280 | 32 mm |
| 281 | 40 mm |
| 282 | 50 mm |
| 283 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. |
| 284 | 150 mm X 150 mm X 60 mm deep |
| 285 | 200 mm X 150 mm X 75 mm deep |
| 286 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 287 | 5/6 amps switch |
| 288 | 15/16 amp switch |
| 289 | 6 pin 15/16 amp socket outlet |
| 290 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 291 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 292 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. |
| 293 | 1 or 2 Module (75mmX75mm) |
| 294 | 3 Module (100mmX75mm) |
| 295 | 4 Module (125mmX75mm) |
| 296 | 6 Module (200mmX75mm) |
| 297 | 8 Module (125mmX125mm) |
| 298 | 12 Module (200mmX150mm) |
| 299 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 300 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 301 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 302 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 303 | Upto 450 mm sweep |
| 304 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 305 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 306 | Group C |
| 307 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 308 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. |
| 309 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 310 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 311 | 8 way, Double door |
| 312 | 12 way, Double door |
| 313 | 16 way, Double door |
| 314 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 315 | 4 way (4 + 12), Double door |
| 316 | 6 way (4 + 18), Double door |
| 317 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB\"s (but without MCB\"s and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 318 | 4 way (4 + 12), Double door |
| 319 | 8 way (4 + 24), Double door |
| 320 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 321 | Single pole |
| 322 | Single pole and neutral |
| 323 | Triple pole |
| 324 | Triple pole and neutral |
| 325 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 326 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 327 | 25 amps |
| 328 | 40 amps |
| 329 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 330 | 40 amps |
| 331 | 63 amps |
| 332 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 333 | Supplying and fixing 20 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 amps \"C\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 334 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 335 | Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. |
| 336 | For 8 way, Double door SPN MCBDB |
| 337 | For 10/12 way, Double door SPN MCBDB |
| 338 | For 14/16 way, Double door SPN MCBDB |
| 339 | Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. |
| 340 | For 4 way, Double door TPN MCBDB |
| 341 | For 6 way, Double door TPN MCBDB |
| 342 | Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. |
| 343 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 344 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 345 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 346 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 347 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 348 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 349 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. |
| 350 | Supplying, installation, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor having high performance, non regulating programmable type, suitable for connected load upto 10Amp, for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. |
| 351 | Supplying, installation, testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight (Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. |
| 352 | 1 output per phase and suitable for single phase supply |
| 353 | Providing and fixing 900 mm long fan downrods from existing fan clamps alongwith PVC insulated 3c x 1.5 sq mm [confirming to IS:694] flexible cable in flexible PVC conduitincluding connection, earthing etc as required |
| 354 | Fabrication, supply, installation, testing & commissioning of,Electricalpanel of cubical construction with front facia of minimum 2.88 sqmm , double door, indoor floor-mounted type, fabricated out of 2 mm thick CRCA sheet, with enclosure protection class IP 42, suitable for operation on415-volt, 50 Hz, 3 phase, 4 wire A.C. supply system, dust and vermin proof, powder-coated in an approved siemens grey shade after 7 tank treatment processes, compartmentalized with hinged lockable doors, detachable cable gland plates made of 3 mm thick CRCA sheet, cable alleys of suitable sizefor cable routing, openable type rear cover and complete with 4 strips of Aluminium bus bars of 500 Amps capacity with heat-shrinkable coloured sleeves and DMC/SMC bus bar supports at required intervals, control terminals, and suitable sized terminal blocks for incoming and outgoing cables, including providing and fixing interconnection with suitable sized solid aluminium strip/ bus Bar and control wiring with suitable sized insulated copper conductor cable. |
| 355 | The entire panel shall have one common aluminium/ G.I. bar of size 20 mm x 5 mm at the rear with 2 earth studs/terminals. A suitable size M.V. Danger Board shall be fixed on the panel. The panel base should have four 300 mm long legs (made of angle irons 50 x 50 x 6 mm) to raise the panel from the floor. The base frame of the panel should be grouted into the floor with four bolts and nuts. The panel shall have provision to accommodate the following switch gears as mentioned below and as per the drawing approved by the engineer-in-charge with the required front area and minimum depth of 300 mm. (Drawings will be approved by the Engineer-in-Charge before fabrication of the panel). |
| 356 | Providing and fixing following switch gears, meters and accessoriesin existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 357 | Incomer |
| 358 | 400 Amp, 4-pole, MCCB, 36 kA breaking capacity, Ics = 100%Icu with TM release, Adjustable overloadand Adjustable short-circuit protection with Spreaders Terminals. ( L&T/Legrand/ Siemens /ABB/ Schneider) - 1 Nos. |
| 359 | Extended Rotary Handle (RHOM) for 400 A MCCB-1 Nos. |
| 360 | MCB SP, 10 KA, 6 AMP for Control circuit. ( L&T/Legrand / Siemens /ABB/ Schneider) - 3 Nos. |
| 361 | Digital Multifunction Meter (L&T/Legrand/Siemens/ABB/Schnieder) - 1 Nos. |
| 362 | R, Y, B LED phase indicating lamps(L & T, Siemens, BCH, Telemecanique, Vaishnav, Kaypee/ESS-BEE) - 3 Nos. |
| 363 | CTs 400/5 A amps, 15 VA with class 1.0 accuracy. (AE /KAPPA/Trinity)-3 Nos. |
| 364 | Outgoing |
| 365 | 63 Amps , 4-Pole, MCCB, 25 kA breaking capacity , Ics = 100% Icu with TM Release, Adjustable overloadand Adjustable short-circuit protection with Spreaders Terminals, DIN-rail kit etc complete. ( L&T/Legrand/ Siemens /ABB/ Schneider) - 3 Nos. |
| 366 | Direct Rotary Handle (RHOM) for 63 A MCCB - 3 Nos. |
| 367 | 100 Amps , 4-Pole, MCCB, 25 kA breaking capacity , Ics = 100% Icu with TM Release, Adjustable overloadand Adjustable short-circuit protection with Spreaders Terminals, DIN-rail kit etc complete. ( L&T/Legrand/ Siemens /ABB/ Schneider) - 6 Nos. |
| 368 | Direct Rotary Handle (RHOM) for 100 A MCCB - 6 Nos. |
| 369 | Fabrication, supply, installation, testing & commissioning of,Electricalpanel of cubical construction with front facia of minimum 2.55 sqmm , double door, outdoor floor-mounted type with slanted roof, fabricated out of 2 mm thick CRCA sheet, with enclosure protection class IP 54, suitable for operation on415-volt, 50 Hz, 3 phase, 4 wire A.C. supply system, dust and vermin proof, powder-coated in an approved siemens grey shade after 7 tank treatment processes, compartmentalized with hinged lockable doors, detachable cable gland plates made of 3 mm thick CRCA sheet, cable alleys of suitable sizefor cable routing, openable type rear cover and complete with 4 strips of Aluminium bus bars of 300 Amps capacity with heat-shrinkable coloured sleeves and DMC/SMC bus bar supports at required intervals, control terminals, and suitable sized terminal blocks for incoming and outgoing cables, including providing and fixing interconnection with suitable sized solid aluminium strip/ bus Bar and control wiring with suitable sized insulated copper conductor cable. |
| 370 | The entire panel shall have one common aluminium/ G.I. bar of size 20 mm x 5 mm at the rear with 2 earth studs/terminals. A suitable size M.V. Danger Board shall be fixed on the panel. The panel base should have four 300 mm long legs (made of angle irons 50 x 50 x 6 mm) to raise the panel from the floor. The base frame of the panel should be grouted into the floor with four bolts and nuts. The panel shall have provision to accommodate the following switch gears as mentioned below and as per the drawing approved by the engineer-in-charge with the required front area and minimum depth of 300 mm. (Drawings will be approved by the Engineer-in-Charge before fabrication of the panel). |
| 371 | Providing and fixing following switch gears, meters and accessoriesin existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 372 | Incomer |
| 373 | 250 Amp, 4-pole, Onload Manual Change-over switch, with operating handle. (L&T/Legrand/ Siemens /ABB/ Schneider) - 1 Nos. |
| 374 | 250 Amp, 4-pole, MCCB, 36 kA breaking capacity, Ics = 100%Icu with TM release, Adjustable overloadand Adjustable short-circuit protection with Spreaders Terminals. ( L&T/Legrand/ Siemens /ABB/ Schneider) - 1 Nos. |
| 375 | Extended Rotary Handle (RHOM) for 250 A MCCB-1 Nos. |
| 376 | MCB SP, 10 KA, 6 AMP for Control circuit. ( L&T/Legrand / Siemens /ABB/ Schneider) - 3 Nos. |
| 377 | Digital Multifunction Meter (L&T/Legrand/Siemens/ABB/Schnieder) - 1 Nos. |
| 378 | R, Y, B LED phase indicating lamps(L & T, Siemens, BCH, Telemecanique, Vaishnav, Kaypee/ESS-BEE) - 3 Nos. |
| 379 | CTs 250/5 A amps, 15 VA with class 1.0 accuracy. (AE /KAPPA/Trinity)-3 Nos. |
| 380 | Outgoing |
| 381 | 40 Amps , 4-Pole, MCCB, 25 kA breaking capacity , Ics = 100% Icu with TM Release, Adjustable overloadand Adjustable short-circuit protection with Spreaders Terminals, DIN-rail kit etc complete. ( L&T/Legrand/ Siemens /ABB/ Schneider) - 2 Nos. |
| 382 | Direct Rotary Handle (RHOM) for 63 A MCCB -2 Nos. |
| 383 | 63 Amps , 4-Pole, MCCB, 25 kA breaking capacity , Ics = 100% Icu with TM Release, Adjustable overloadand Adjustable short-circuit protection with Spreaders Terminals, DIN-rail kit etc complete. ( L&T/Legrand/ Siemens /ABB/ Schneider) - 6 Nos. |
| 384 | Direct Rotary Handle (RHOM) for 63 A MCCB - 6 Nos. |
| 385 | Supplying and fixing of following sizes of flexible steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 386 | 20 mm |
| 387 | 25 mm |
| 388 | Supplying and fixing following rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 389 | 40 amps, DPMCB |
| 390 | 63 amps, DPMCB |
| 391 | Supplying and fixing following rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 392 | 40 amps, TP&N MCB |
| 393 | 63 amps, TP&N MCB |
| 394 | Supplying and fixing following rating, four pole, 415 volts, MCCB suitable for mounting in the existing Vertical TPN MCB DB complete with connections, testing and commissioning etc. as required. |
| 395 | 63 Amp \"C\" Curve, 10/18kA |
| 396 | 100 Amp \"C\" Curve, 10/18kA |
| 397 | Supplying and fixing following rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 398 | 32 A, Triple pole |
| 399 | 63 A, Triple pole |
| 400 | Providing and fixing following capacity & size, 4-pole 415 V, powder painted metallic bus-bar box , on surface/recess, cable knock-outs for entry/exit, 4-strips ofcolour coded copper strips in step type arrangement complete with bakelite insulator sheet, powder painted including earthing etc. as required. ( Make:Socomec / Tekson / HPL /Sainik/ Havells) |
| 401 | 63 A Bus-bar box of nominal size 28 x 23 x 13 cm |
| 402 | 100 A Bus-bar box of nominal size 36 x 30x 15 cm |
| 403 | Supplying and Laying of one number aluminium conductor, XLPE Insulated, PVC sheathed, armoured power cable of 1.1 kV grade , confirming to IS : 7098 (Part-1) 1988 of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 404 | 2c x 25 sq mm |
| 405 | 3.5 x35 sqmm |
| 406 | 3.5 x50 sqmm |
| 407 | Supplying, Laying and fixing of one number aluminium conductor, XLPE Insulated, PVC sheathed, armoured power cable of 1.1 kV grade , confirming to IS : 7098 (Part-1) 1988 of following size on wall surface/Cable tray as required. |
| 408 | 2c x 25 sq mm |
| 409 | 3.5 x35 sqmm |
| 410 | 3.5 x 50 sq. mm |
| 411 | The road crossings of power cablethrough trenchless boring.Trenchless horizontal boring using Manual/ Machine Moling techniqueat 0.75 metre below the ground level for following size pipes,including survey of under groundtilities,excavation of pits,moling with the hole size not exceeding 20% of the pipe dia,backfilling, compaction and restoration of the pits to original condition etc. as required. The rates for moling, as indicated are inclusive ofxcavation of pits, backfilling, compaction andrestoration of the pits to original condition. Any damages occurred to other utilities during the Moling operation shall be immediately notified and rectified by the contractor without any cost implication to the Department.The length of the Hole (excluding the sizes of the pits on both ends) shall be considered for the measurement of Moling length. However, intermediate pits will consider in the moling length.i)Upto 200 mm dia DWC HDPE / G.I. /PVC |
| 412 | Supplying and fixing following sizesDLP U-PVCtrunkingwith cover, separator partition andaccessories (Joints, Angles, Bends, End Caps, Brackets, Junctions etc) on surface etc complete as required. |
| 413 | 32 mm x 12.5 mm |
| 414 | 105 mm x 50 mm (2 compartments) |
| 415 | Supply, Installation, Testing and Commissioning of 900 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.. |
| 416 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, down rod upto 30 cm long , 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 8, Air delivery minimum 215 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%,without remote and compatible with existing step electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (BLDC Ceiling fan with minimum 2 year Warranty) |
| 417 | Supplying and installation of PVC Exhaust fanwith louver shutter 250 mm sweep in the existing opening, including making good the damage, connection, testing , commissioning etc as required.(Havells / C&G / Orient / Usha /Atomberg/ Almonard) |
| 418 | Supplying and installation of 225/ 230 mm sweep, single phase, metallic exhaust fanin the existing opening, including making good the damage, connection, testing, commissioning etc. as required.(HavellsVentil Airor with similar specifications C&G / Orient / Usha / Almonard) |
| 419 | Supplying and installation of 300 mm sweep, 1400 RPM heavy-duty, single phase, metallic exhaust fan Conforming to IS:2312 -1967in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.(HavellsTurbo force Heavy Duty Exhaust Fan or with similar specifications C&G / Orient / Usha / Almonard) |
| 420 | Supplying installation testing and commissioning of 400 mm sweep wall fan with thermal overload motor protection, delivery rate 85 CMM at 1330 rpm (or better) suitable for operation on220-240V and 50Hz Ac supply etc required.(Make: Crompton- Hiflo Wave plus/Havells/Orient/Usha/Almonard) |
| 421 | Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe and making good the same etc. complete as per direction of Engineer-in-charge. |
| 422 | Makinghole of the required size and shape inbrick masonry wall for the installation of an exhaust fan of size 225 mm/230 mm sweep and fixing 230 mm dia PVC pipe conforming to BIS-12818 and making good the wall by plastering, etc., complete as per the direction of the engineer-in-charge |
| 423 | Making hole of the required size and shape in a brick masonry wall for the installation ofexhaust fan of size 250 mm sweep and making good the wall by plastering, etc. complete as per direction of Engineer-in-charge. |
| 424 | Supply and fixing of 8 mm thick BWP/marine grade plywood wood board having a circular /rectangular hole to suit the sie of exhaust fan upto 380 mm on wall /window for etc as required including the cost of making hole, nuts and bolts,etc. as required. |
| 425 | Providing and fixing a metallic louvred shutter suitable for a 300 mm exhaust fan, the louvres should be able to open when the fan is on and close when the fan is turned off, on the existing opening on the wall, etc., as required. |
| 426 | Providing and fixing a metallic louvred shutter suitable for a 380 mm exhaust fan, the louvres should be able to open when the fan is on and close when the fan is turned off, on the existing opening on the wall, etc., as required. |
| 427 | Supply, installation, testing, and commissioning of integrated LED Batten luminaire, 600 mm (nominal size) with a minimum system lumen output of 1000 lumen andwith a minimum system luminous efficacy of 100 lm/W, made of aluminium housing having a colour temperature5500K - 6500 K, Average life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling/wall, including connections, earthing, etc. as required. |
| 428 | Supply, installation, testing, and commissioning of integrated LED Batten luminaire, 1200 mm (nominal size) with a minimum system lumen output of 4000 lumen and with a minimum system luminous efficacy of 120 lm/W, made of aluminium housing having a colour temperature5500K - 6500 K, Average life L70B50: 50000 hours, THD ≤ 10%, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling/wall, including connections, earthing, etc. as required. |
| 429 | Supply, installation, testing, and commissioning of 2 ft. x 2 ft. (nominal size) LED Surface Mounted LED Panel Light, in metallic housing, with a minimum system lumen output of 3960 lumens and a minimum system luminous efficacy of 110 lm/W, colour temperature of 5500K–6500K, average life L70B50: 50000 hours, THD ≤ 10%, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling, including connections, earthing, etc. as required. |
| 430 | Supply, installation, testing, and commissioning of 2 ft. x 2 ft. (nominal size) LED Recess Mounted LED Panel Light, in metallic housing, with a minimum system lumen output of 3960 lumens and a minimum system luminous efficacy of 110 lm/W, colour temperature of 5500K–6500K, average life L70B50: 50000 hours, THD ≤ 10%, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling, including connections, earthing, etc. as required. |
| 431 | Supply, installation, testing, and commissioning of LED bulkhead fittings with IP 66 ingress protection, with a minimum system lumen output of 1000 lumens and a minimum system luminous efficacy of 100 lm/W, made of aluminium housing having a colour temperature of 5500K–6500 K, average life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, diffuser, electronic driver, etc. as required directly on the wall, including connections, etc. as required. |
| 432 | Supply, installation, testing and commissioning of surface mountedLED downlighter luminaire inmetallic housing, with a minimum system lumen output of 1800 lumen andwith a minimum system luminous efficacy of 100 lm/W, Average LED life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, diffuser and electronic driver, directly on ceiling, including connections and earthing etc. as required. |
| 433 | Supply, installation, testing, and commissioning of recess mounted LED downlighter luminaire complete with aluminium powder coated pressure die cast housing and PC diffuser and electronic driver, with a minimum system lumen output of 1800 lumens and a minimum system luminous efficacy of 100 lm/W, average LED life L70B50: 50000 hours, THD ≤ 10%, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, diffuser and electronic driver, directly on ceiling, including connections and earthing, etc. as required. (Havells Integra Neo or of similar specification in Philips/ Jaquar/ LT/ Wipro/Regent) |
| 434 | Supplying, installation, testing and commissioning of 70 Watt LED street light luminaire made up of die-cast aluminium housing, with IP66 degree of protection, complete with the driver, LEDs with optical lens, toughened glass cover, etc. The luminaire should have suitable for operation on voltage range 140-270V, 1Φ, 50Hz AC supply system, and a mechanical impact resistance rating of lk>=07. surge protection of ≥ 10KV, PF≥ 0.90 and minimum system luminous efficacy of 100 lm/W. The luminaire shall be designed for an average system life L70B50: 50000 hours and suitable for mounting on the pole bracket up to outer dia 50 mm, including installation on existing street light pole bracket connections and earthing etc., as required. LM 79 and LM 80 reports need to be submitted from a NABL/UL accredited lab to verify the above parameters. |
| 435 | Supplying and fixing suitable size GI box in recess, including providing and fixing of Modular LED Foot light /skirting light,including connection etc. as required |
| 436 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 437 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling etc as required. |
| 438 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 439 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 440 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 441 | Dismantling of the existing recessed switch board of light points/power points, power/light plug points/socket outlet metal boxes of any size, along with phenolic laminated sheet, switches, sockets, etc., making good the damage to match the adjacent surface, etc., as required. |
| 442 | Dismantling of the existing recessed SPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required. |
| 443 | Dismantling of the existing recessed vertical type or horizontal type TPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required. |
| 444 | Dismantling of SPN Industrial type socket outlet alongwithMCB, in sheet steel enclosure including credit for same etc. as required. |
| 445 | Dismantling wires from the following sizes, existing circuit/submain/power wiring conduits, complete as required. The length of the conduit from which the wires are removed will be measured for payment purposes, irrespective of the number of wires in it. |
| 446 | Up to 25 mm conduit. |
| 447 | Above 25 mm conduit. |
| 448 | Dismantling of the existing ceiling rose, holder, and wall bracket and depositing the same with the listing of materials in the store. |
| 449 | Dismantling of existing fluorescent fitting from ceiling/ wall including making good the damage to match the adjacent surface, etc., as required. |
| 450 | Dismantling of the existing ceiling fan/ exhaust fan of any size installed in the building and depositing it in the MMC store. |
| 451 | Supplying, installation, testing and commissioning of 2 Ton, Inverter type hot & Cold , minimum 4 Star BEE rating,Hi-wall Split type Air conditioner completesuitable for operation on 230 V, 50 Hz single phase AC supply, with all standard accessories ( Indoor Unit, Outdoor Unit, Inter-connecting kit with copper pipe wrapped with insulation, Drain pipe and connecting cable, copperCondenser and Evaporator Coil, remote control, user manual with warranty certificate as per OEM specifications). i) Connecting copper pipes and cablelength3 mtrs.ii)Warranty :minimum 1 Year on complete Unit, PCB warranty 5 Years and 10 Years on Compressor.iii) Cooling capacity (100%)as per BEE label : 7000 Watt minimumiv) Rated ISEER : minimum 4v) The AC should be designed to work at a maximum operating ambient temperature of up to 52 degrees Celsius (outdoor temperature). |
| 452 | Supplying, installation, testing and commissioning of 2 Ton, Inverter type, minimum 4 Star BEE rating,Hi-wall Split type Air conditioner completesuitable for operation on 230 V, 50 Hz single phase AC supply, with all standard accessories ( Indoor Unit, Outdoor Unit, Inter-connecting kit with copper pipe wrapped with insulation, Drain pipe and connecting cable, copperCondenser and Evaporator Coil, remote control, user manual with warranty certificate as per OEM specifications). i) Connecting copper pipes and cablelength3 mtrs.ii) Warranty : minimum 1 Year on complete Unit, PCB warranty 5 Years and 10 Years on Compressor.iii) Cooling capacity (100%)as per BEE label : 7000 Watt minimumiv) Rated ISEER : minimum 4v) The AC should be designed to work at a maximum operating ambient temperature of up to 52 degrees Celsius (outdoor temperature). |
| 453 | Providing & fixingofrefrigerantcopper pipingwith insulation and wire for 1.5-2.0ton Split AC as per manufacturers specification , clamps, etc. complete as reqd. ( two copper pipes one suction andone discharge line with wire and foam insulation tubing will be measured as one unit) |
| 454 | Supply, Installation, testing and commissioningof wall mounted typevoltage stabilizer suitable for 2.0 Ton Split Air conditionerwith High / Low voltage cut off, thermal overload relayand Time Delay Relay, WORKING VOLTAGE RANGE : 150-285 Volts including connection etc. as required. (V-Guard make-Model VND 500 or similar of Totaline / Logicstat / Microtek/Luminous/ Bluebird with minimum 3 year warranty.) |
| 455 | Supplyingand fixingof floor mounted / wall mounted Out Door UnitMounting bracket suitable for1.5/ 2ton split Air conditioner etc complete as required. |
| 456 | Providing and fixingCPVCpipe for air conditioners 20mm dia with all accessories e.g. elbows, unions, sockets, reducers, reducing tees, nipples etc., including fixing the pipe with clamps at 1.00 m spacing on wall / floor etc as required.(Ashirwad /Astral /Finolex/ Supreme/ Prayag ) |
| 457 | Supply, installation, testing & commissioning of 7.5 kVA True online UPS of single phase in and single phase out arrangement including sealed maintenance free batteries sufficient to provide minimum 30 mins backup.The system shall be suitable for operation on input voltage range of 170 to 270 V & output voltages of 220V (adjustable) with+/- 1%of regulation and overload capacity of 10% for 10 min and suitable to operate in temperature range of 0-40 degree Centigrade including connection. The entire UPS system (including batteries) should have a warranty of minimum 2 years. This inlcudes Open Batteryrack, Battery interconnecting cable and UPS to Battery bank cable upto 5 mtrs etc as required [Make- Nexus Power Sytems/Emerson/Vertiv-liebert] |
| 458 | Supplying & fixing ofWater Pressure Pump (booster pump) 1 HP, single phase, 220 volt,Automatic ON and OFF Operation Monoblock motor pump sethaving suctionX deliverysize 32 mm X 25 mm, head up to36 m, tank capacity 24 litre, complete as required.(Model no KSB KHM0404 KSB make) |
| 459 | Supplying and fixingPRCD (Portable Residual Current Device) Plug top, 16 A 30 mA rating including connection etc. as required. |
| 460 | Supplying, installation testing and commissioning of BEE5 star rating, 15 litres capacity water storage heater, withprotection against over heating, Multifunction Safety Valveandexternal adjustable thermostat, with16 A, 240 V, plug top with in-built 30 mA RCDand02 nosflexible connection pipe suitable for working with 230V AC, 50 Hz, 1 Phase supply etc as required. (Make:Havells / Crompton/ AO Smith /Racold /Jaguar with 7 year warranty on inner tank, 3 year warranty on heating element, 2 year comprehensive Warranty) |
| 461 | Less credit for the unserviciable items dismantled items during execution of the work. |
| 462 | Assorted PIANO/modular Type Switches |
| 463 | Assorted PIANO/modular Type Sockets |
| 464 | Assorted Bell push/PIANO/modular Type |
| 465 | Assorted Call bell buzzer single phase |
| 466 | Assorted Brass batten/ angle holder/Brass Bracket |
| 467 | Assorted Fan regulator/resistance type |
| 468 | Assorted Telephone Socket outlet |
| 469 | Assorted T.V. Socket outlet |
| 470 | Assorted Capacitor, 3.15/2.50/2.25 mfd |
| 471 | Assorted 1200/1400 mm sweep ceiling Fanwith blades |
| 472 | less credit for the dismantled Copper wirewires from light points/ circuit/ submain/power circuit wiring,. |
| 473 | less credit for the dismantled aluminium wirewires from light points/ circuit/ submain/power circuit wiring,. |
| 474 | Assorted metal switch box. |
| 475 | Assorted MCB DB SPN with out MCBs |
| 476 | Assorted MCB DB TPN without MCBs |
| 477 | Assorted MCB SP |
| 478 | Assorted MCB DP |
| 479 | Assorted MCB TP AND TP&N |
| 480 | Assorted Industrial type sockets |
| 481 | ADD labour cess @1% onDSR 2022 (Elect.) amount Rs. 23,36,738.71/- |
| 482 | Add Difference in GST of (18 &12 %) by MF 0.0633 on DSR Elect i.e Rs. 23,36,738.71/- (DSR) + 23,367.39/- (L/Cess) = Rs. 23,60,106.10/- |
| 483 | Less COST INDEX on DSR(E) @ -2.73 % i.e. Rs. 23,36,738.71/-(DSR) + 23,367.39/- (L/Cess) + Rs. 1,49,394.72/- (GST difference) = Rs. 25,09,500.82/- |
| 484 | Correction factor on existing Items of DSR @ 0.973 as per CPWD Office Memorandum 158/SE (TAS)/GST/2024/02-E DATED 8-8-2024 (U) i.e Rs. 23,36,738.71/- (DSR) + Rs. 23,367.39/- (L/Cess) + Rs. 1,49,394.72/- (GST difference) + 0.00 (DSR Civil) - Rs. 68,509.37/- (Cost Index) = Rs. 24,40,994.45/- |