| 1 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.)By Mechanical Means. |
| 2 | Excavationforfoundationinearth,soilsofalltypes,sand,gravelandsoftmurum, includingremovingtheexcavatedmaterialuptoadistanceof50metresbeyondthe building area and stackingandspreadingasdirected,dewatering,preparingthebed forthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means |
| 3 | Providingdry/trap/granite/quartzite/gneissrubblestonesoling15cmto20cm thickincluding hand packing and compacting etc. complete. |
| 4 | Providing and laying Cast in situ / Ready Mix cement concrete in M 10 of trap / granite / quartzite / gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying / pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant ( Pan mixer ) etc. complete. With fine aggregate ( Crushed sandVSI Grade) |
| 5 | Providing and laying in situ / Ready Mix cement concrete M 20 of trap / granite / quartzite / gneiss metal for R.C.C. work in foundations like raft, stripfoundations, grillage and footingsofR.C.C.columns and steel stanchions etc.including bailing out water, Steel centering formwork, laying / pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided ( Excluding reinforcement and structural steel ) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 6 | Providing and laying Cast in situ / Ready Mix cement concrete M 20 of trap / granite / quartzite / gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying / pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided andcuring etc. complete.( Excluding reinforcement and structural steel ).with fullyautomatic micro processor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate ( Crushed sand VSI Grade ) |
| 7 | Providing and laying Cast in situ / Ready Mix cement concrete M 20 of trap / granite / quartzite / gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying / pumping, compaction androughening the surface if special finish is to be provided and curing etc.complete. ( Excluding reinforcement and structural steel ). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate ( Crushedsand VSI Grade) |
| 8 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations,slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 9 | Providing second class Burnt Brick masonry with conventional /I.S. type bricks in cm 1:6 in foundations and plinth of inner walls / in plinthexternal walls includingbailing out water manually , striking joints on unexposedfaces, raking out joints on exposedfaces and watering etc. Complete. |
| 10 | Filling in plinth and floors with contractorsmaterial/brought from outside and approved byEngineer inchargein layers of 15 cmto 20 cm including watering and compactionetc.complete. |
| 11 | Providing secondclass Burnt Brick masonry with conventional / I.S. typebricksin cm 1:6 in superstructure including striking joints, raking out joints, wateringand scaffolding etc. Complete |
| 12 | Providinginternalcementplaster12mm thickinsinglecoatincementmortar1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc.complete. |
| 13 | Providing internal cement plaster 20 mm thick in single coat in cement mortar 1.4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. |
| 14 | Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to605mm x590mm to 605mm of8to10mm thicknessandconfirming to IS. 15622-2006( groupBla) of approvedmake, shade andpatternforflooring inrequired positionlaidonabedof 1:4 cement mortar including neat cement float, filling joints,curingandclearing etc. complete. |
| 15 | Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete |
| 16 | Providingandlayinginpositionflooring oftelephoneblack/AmbaWhite/Catbary brown / Rubyred / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. |
| 17 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing,gussetplatesetc.asperdetaileddesignsanddrawingsorasdirected including cutting,fabricating,hoisting,erectingfixinginposition,Makingriveted/ bolted/welded connectionandone coat of anticorrosive paint andover it 2 coats of oil painting approved quality and shade etc. complete. |
| 18 | Providing andfixing colourcoatedZincalume (R)AZ150(min150gms/sq.mt. totalon each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550MPayieldstrength, metallic hot dip coated with Aluminium-Zinc alloy (55%aluminium 43.4%zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganicpigment).Thepaintshallhaveatotal coatingthicknessofnominal35um, comprising of nominal 25 um exterior coat on top surface andnominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center.The endribshallbe designedforanti-capillarygroove.andreturnleg.Thefeed material should have coil manufacturersproductdetailsmarkedaregularinterval.Includingfastenerswithmin. fastenedwithmin.25umZinc-Tinalloycoated,Hexhead, |
| 19 | Providing and fixing plain zinc sheeting of 0.80 mm thick (22 B.W.G.) over the ridge hip or valley to galvanized iron sheet roofing including all fastening and bolt galvanised iron screws and bolts, lead and bitumen washers etc. complete.(Weight of 6.8 Kilogram/sq.m.). |
| 20 | Providing and applyingtwo coats of exterioracraylic emulsion paint confirming to corresponding I.S.of approved manufacture and of approvedcolour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete. |
| 21 | Providing and fixing information, board |
| 22 | Test of Brick-Water Absorpation,(Set of 5 Bricks)Compressive Strenght, Effiorescence |
| 23 | Compressive test of Concrete Cubes(Set of 3 Cubs) |
| 24 | Steel bar Testing (Up to 16 mm)-(Set of 3 Bars) |
| 25 | Steel bar Testing (Up to 16 mm)-Tensile Strength.% Elongation, Yield Stress, Wt./m,Bend Rebend Test ,Proof |
| 26 | Royalti Charges HardMurum |
| 27 | Royalti Charges For- Rubble |
| 28 | Add Royalty Charges - Sand |
| 29 | Add GST Charges - 18% |