| 1 | Connecting Corridor Between Academic and Hospital Campus at Govt Medical College Orai District Jalaun (U.P.) |
| 2 | CIVIL WORK |
| 3 | Boring, Providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-20 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 300 mm dia single bulb piles |
| 4 | Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches including all T & P phowarah and basket etc. complete. |
| 5 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. |
| 6 | Providing and layingin cement concrete 1:4:8 (1 cement :4 fine sand :8 graded stone aggregate 40 mm nominal size) and curing complete,including cost ofform-work,in foundation and floors. |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 8 | foundations, footings, bases of columns, etc. for mass concrete |
| 9 | columns, pillars, piers, Abutments, posts and Struts |
| 10 | R.c.c. works with cement approved coarse sand and 2 cm. (3/4\") guageapproved stone ballast in the proportion of 1:1.5:3 in Plinth Beam excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc. and also including supply of all materials, labour, T & P etc., required for proper completion of the works. Strength of the concrete shall not beless than M-20. |
| 11 | Same as Item No. 9 but R.C.C. work in Footing and foundation. |
| 12 | Same as Item No. 9 but R.C.C. work in column |
| 13 | Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work(whennot includedin anover all rates )wroughttorequired shape as necessary including bending for proper completion of thework andincluding supply of steel itswastage bendhooks andauthorisedover lappingshallbe measured upto floor two level. |
| 14 | First class brick work in 1:6 cement and coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc reqiored for proper completion of the work. |
| 15 | 12 mm cement plaster in single coat on rough side of single or halfbrick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand . |
| 16 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand &anufacturer, over the plastered wall surface to prepare the surface even & smooth complete. |
| 17 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 18 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 19 | Providing & Installation of Microcell Polycarbonate panels of 16mm thick (min.) single panel. Panel Width shall not be less than 1040 mm to ensure best performance for wind uplift, vibration, oil canning and visual appearance. The panels shall be uniform in color with an integral Microcell/Multicell. Panels shall be manufactured with Vertical Standing Seam with maximum height 15mm at both sides of the panel. Snap-on connector to interlock the panels shall have a double tooth grip-lock locking mechanism to ensure maximum uplift capability. Panel shall be with additional End- cap/Aluminum U-Profile (mill finish) for ends. Panels shall be co-extruded UV protected. Panel shall be fixed over structural steel / MS purlin/ M.S. tubular truss including all work complete in all respect conforming to the detail technical specifications enclosed and as per approved shade / colour and directions of Engineer-In-Charge |
| 20 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick. |
| 21 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). |
| 22 | Painting or Vanishing two coat on iron work in small areas or new wood work with one coat of ready mixed priming paint and one coat of approved superior ready mixed paint of clear synthetic varnish including supply of all materials, labour, T & P etc. required for proper completion the work. Paint to be used should confirm to the I.S.I. No. 103 1950. |
| 23 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 24 | Wiring for circuit/sub-main wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVCconduit as required. 2X2.5 sqmm + 1x 2.5 sqmm earth wire |
| 25 | Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: 20mm |
| 26 | Supplying and fixingfollowing size/modules, GI box along with modular base& cover plate for modular switches in recess etc as required.1 or 2 module(75mm X 75 mm ) |
| 27 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch,connection etc. as required. |
| 28 | Installation, testing and commissioning of prewired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required. |
| 29 | Wiring for group controlled(looped) light point/fan point/exhaust fan point/call bell point(without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper condutor single core cable in suface/recessed PVC conduit, and earthing the point with 1.5 sq. mm. FRLS PVA insulated copper conductor single core cable etc. as required. Group C |
| 30 | Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C\" series,miniature circuit breaker (MCB) suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required. Single Pole |
| 31 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 35 sq. mm and Upto 95 sq. mm. |
| 32 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. 150 mm Dia |
| 33 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1100 Volts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size.as per direction of Engineer-Incharge.complete in all respect The armouring of the cable shall be properly connected with the earth conductor by clamps etc.6 sqmm2 core |
| 34 | Supply of12 W LED DOWNLIGHTERcomplete in all respect. Make-Philips or Eq |
| 35 | Earth Work in Laveling, Dressing, Making huts, Making Approch road for Material and other Contengency Work in favour of CONNECTING CORRIDOR BETWEEN ACADEMIC AND HOSPITAL CAMPUS AT GOVT MEDICAL COLLEGE ORAI DISTT.- JALAUN (U.P.) by Direction of Enginear in charge. All work should be done including labour & Material Costin. and also Payment done after making PCR & Other Official Paper work. |
| 36 | GST Extra as per applicable |