| 1 | Rewiring of 12 C-type quarters (C-107-118) at Jyotipuram Colony |
| 2 | Supply of PVC Insulated and PVC Sheathed/XLPE Power Armoured Cable of 1.1 KV grade of 4 Core 50 Sq mm Aluminum Conductor cable. |
| 3 | Supplying and laying of 90 mm dia (OD-90 mm & ID-76 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 4 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 kV grade of 50 sq. mm direct in ground including excavation, sand cushioning, protective covering andrefilling the trench etc. as required. |
| 5 | Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 kV grade of 50 sq. mm (clamped with 25x3mm MS flat clamp) on wall surface as required. |
| 6 | Supplying and fixing 12 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) |
| 7 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 8 | Supplying and fixing 63A rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 9 | Wiring for circuit/submain wiring along with earth wire with the 2 x 10 Sq mm + 1 x 6 Sq mm earth wire of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 10 | Wiring for circuit/submain wiring along with earth wire with the 2 x 4 Sq mm + 1 x 4 Sq mm earth wire of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 11 | Wiring for circuit/ submain wiring along with earth wire with the 2 x 2.5 Sq mm + 1 x 2.5 Sq mm earth wire of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 12 | Supplying & Drawing Co-Axial TV Cable in the existing surface/recessed PVC conduit medium class PVC conduit as required |
| 13 | Wiring for light point/ tan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B |
| 14 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 15 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 1 No TV Antenna modular socket outlet, connection etc. as required. |
| 16 | Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable Gi box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 17 | Supply and fixing of 20 mm medium class PVC conduit alon with aceesories and surface/recess including cutting wall and making good the same in case of recess counduit.- For TV cable |
| 18 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 19 | Supply, Installation, Testing & commissioning of Main Distribution LT Panel, outdoor type, floor mounted, made out of 14/16swg CRC sheet steel, dust, vermin proof, duly powder coated and wired as per standard. The panel will consist of 1 No 100 A, I/Comer 4 pole MCCB, 6 Nos 63 A O/g DP MCB 10KA, 6 Nos Electronic Energy Meter LCD Display 0-60A, for O/g feeders with High Conductive electrolytic -grade aluminum bus bar of 150 Amps, TPN, with heat shrinkable sleeve, duly color coded and 5 Sets of LED Phase indicators etc. as required, (as per drawing enclosed) |
| 20 | Installation, Testing & Commissioning of pre-wired, LED Tube Light fitting 18/20 Watt, complete with all accessories and tube etc directly on celing/wall including connection with 1.5 Sq mm FRLS PVC insulated copper conductor, single core cable and earthing etc as required |
| 21 | Supply of 18/20 Watt LED tube light 4 feet with commplete set like Clip etc. |
| 22 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing Modular Stepped type electronic Fan Regulator Including connection etc. as required |
| 23 | Supply, installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos, canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS: 374- 2019), THD less than 10%, remote or electronic regulator unit for coeed control and all remaining accessocies including saferuolo out |
| 24 | Installation of exhaust fan-12\" in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 25 | Supply of metal exhaust fan -12\" in existing opening |
| 26 | Supplying and fixing 3 pin 5 amp ceiling rose on exsisting junction box including connection etc. as required |
| 27 | Supplying and fixing brass batten/ angle holder including connection etc. as required |
| 28 | Supply Installation & commissioning of LED Lamp B22, 15 Watt, Complete |
| 29 | Supplying and fixing call bell/buzzer suitable for single phase, 230 V, complete as required |
| 30 | Supply installation & commissioning of LED LampBulk head fitting, Complete. |