Tender For Construction work of Interpretation Center and Cafeteria under Smart City Project - EARTH WORK 2 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil 3 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 4 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 5 ANTI TERMITE WORK 6 Diluting and injecting chemical emulsion for PRE CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 7 P.C.C. WORK 8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 9 R.C.C. WORK 10 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishingand reinforcement as per direction of the engineer-in-charge; Concrete of M25 grade with minimum cement content of 330 kg /cum 11 All works upto plinth level 12 All works above plinth level upto floor V level 13 Providing centering & shuttering including strutting, propping etc. & removal of form including all materials, labour and T & P etc. required for proper completion of work all complete 14 Foundations, footings, bases of columns, etc. for massconcrete 15 Lintels, beams, plinth beams, girders, bressumers and cantilevers 16 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more. 17 BRICK WORK 18 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 19 FINISHING WORK 20 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 21 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 22 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 23 DOOR & WINDOW WORK 24 Providing & fixing of Alluminium Windows & ventilator/ Partition in wood finished colour including all necessary T&P withnecessary fittings all complete direction of architect in charge.(Make -Eternia/ Spectrum/ Tostem) 25 Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 26 Frame anchor HRD-C 10x140 27 Frame anchor HRD-C 10x120 28 Providing and fixing double glazed hermetically sealed glazing inaluminium windows, ventilators and partition etc. with 6 mm thick Toughned glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete 29 FLOORING WORK 30 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying oftiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily Glazed vitrified floor tiles polished finish of size Size of Tile 800 x 1200 mm 31 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar.Red sand stone 32 MISSLENIOUS WORK 33 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqmof cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineerin- Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 34 25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with :Second class teak wood 35 Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will bepaid separately). 36 Providing & fixing of Puff Panels including all necessary T&P nut bolts, Washer all complete in direction of engineer in charge. 37 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes 38 Supplying & Laying ofwater proof Board including nut bolt washer & including necessary T&P all complete in direction of engineer in charge. Make Ramco Hilux or equvellent 39 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 40 Structural steel work in single section, fixed with or without connectingplate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete 41 Providing and Fixing 15 mm thick densified tegular edged eco friendlylight weight calcium silicate false ceiling tiles of approved texture ofsize 595 x 595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanised steel sections (galvanising@ 120 grams per sqm including both side) consisting of main ‘T’runner suitably spaced at joints to get required length and of size24x38 mm made from 0.33 mm thick (minimum) sheet, spaced1200 mm centre to centre, and cross “T” of size 24x28 mm madeout of 0.33 mm (Minimum) sheet, 1200 mm long spaced betweenmain’T’ at 600 mm centre to centre to form a grid of 1200x600 mmand secondary cross ‘T’ of length 600 mm and size 24 x28 mmmade of 0.33 mm thick (Minimum) sheet to be inter locked at middleof the 1200x 600 mm panel to from grid of size 600x600 mm, restingon periphery walls /partitions on a Perimeter wall angle pre-coatedsteel of size(24x24X3000 mm made of 0.40 mm thick (minimum)sheet with the help of rawl plugs at 450 mm centre to centre with 25mm long dry wall screws @ 230 mm interval and laying 15 mmthick densified edges calicum silicate ceiling tiles of approved texturein the grid, including, cutting/ making opening for services likediffusers, grills, light fittings, fixtures, smoke detectors etc., whereverrequired. Main ‘T’ runners to be suspended from ceiling using G.I.slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mmdia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods withgalvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at1200 mm centre to centre along main ‘T’, bottom exposed with 24mm of all Tsections shall be pre-painted with polyster baked paint,for all heights, as per specifications, drawings and as directed byEngineer-in-Charge 42 Providing & Fixing of Display Panel with signages (made in wood & glass) as per Drawing & design with display material including all necessary T&P etc all complete in direction of engineer in charge. 43 Cost of Audio Video System 44 Chair 45 Table 46 Providing & fixing of Side Pole Umbrella Made in PVC coated Polyster fabric and frame made in stainless steel and powder coated base weight 150 Kg approx and base size 900x900 mm etc including all necessary T&P all complete in direction of engineer in charge .Model SIDE POLE UMBRELLA 2.4 mtr x 2.4 mtr SIDE POLE UMBRELLA Make Loomcraft/ Western outdoor/ Mccoy) 47 WIRING POINTS AND SUBMAINS 48 Point wiring in PVC Conduit 49 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 50 Group C 51 Power plug wiring in PVC conduit (2 x 4 sqmm.) :- 52 Wiring for light/ power plug with 2X4 sq. mm FRLS PVCinsulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 53 Circuit / Sub main wiring in PVC conduit :- 54 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 55 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earth wire 56 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire 57 4 x 6 sq.mm. + 2 x 6 sq.mm. Earth wire 58 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 59 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 60 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 61 20 mm. 62 S/F light plug point modular type accessories :- 63 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required 64 S/F power plug point modular type accessories :- 65 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 66 S/F modular type electronic fan regulator :- 67 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 68 S/F modular type blanking plate :- 69 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 70 2 Pair 71 S/F MODULAR BOXES, BASE & COVER PLATE :- 72 Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches inrecessetc as required 73 1 or 2 Module (75 mm x 75 mm) 74 S/F MODULAR TYPE SWITCH / SOCKET :- 75 Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required 76 Telephone Socket outlet 77 DISTRIBUTIONBOARDS,MCBs, MCCBsANDSFUs 78 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 79 4 way (4 + 12), Double door, horizontal type 80 6 way (4 + 18), Double door, horizontal type 81 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required 82 single pole 83 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 84 40 amps. 85 63 amps. 86 Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required. 87 Supplying and fixing 20 A, 415 V, TPN Industrial type socketoutlet, with 4 pole and earth, metal enclosed plug topalongwith 20 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 88 G.I.EARTHING 89 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 90 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 91 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 92 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 93 Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. CAT- AAA 94 Supply and fixing of 12 Watt to 15 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing with extended heat sink, diffuser of Polycarbonate meterial and driver set complete in all respect. CAT- AAA 95 Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA 96 Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA 97 Providing & Fixing of modular plate type white RJ 45 CAT 6 Data outlet / information outlets ETL verified to meet or exceed TIA / EIA category 6 requirements, universal wiring label permitting to either T568A or T568B, UL listed,for computer networkingcomplete in all respect with cover plate, grid plate, screws, MS box, etc with connections as required. 98 1 nos. RJ 45 Data Outlet 99 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos.blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperaturerise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 100 1200 mm sweep 101 Supply,installation, testing and commissioningof Main DistributionBoard suitable for upto 125 amp FP MCCB incomer and single / three phase outgoing MCBs, IP 43 protection, double metal door, factory fabricated, wall mounting type in surface / recess, powder coated, 415 V / 200 amp copper Bus Bar, earth and neutral bar, removable gland plates, cable glands including connection with outgoing feeders completeinall respect. DBs shall be original factory fabricated of approved make. The rates shall be excluding all incoming and outgoing circuit breakers. 102 8 Way TPN 103 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 104 a) for 110mm dia pipe. 105 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110MM Dia 106 EARTH WORK 107 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil 108 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 109 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 110 ANTI TERMITE WORK 111 Diluting and injecting chemical emulsion for PRE CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 112 P.C.C. WORK 113 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 114 R.C.C. WORK 115 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishingand reinforcement as per direction of the engineer-in-charge; Concrete of M25 grade with minimum cement content of 330 kg /cum 116 All works upto plinth level 117 All works above plinth level upto floor V level 118 Providing centering & shuttering including strutting, propping etc. & removal of form including all materials, labour and T & P etc. required for proper completion of work all complete 119 Foundations, footings, bases of columns, etc. for massconcrete 120 Lintels, beams, plinth beams, girders, bressumers and cantilevers 121 Suspended floors, roofs, landings, balconies and access platform 122 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more. 123 BRICK WORK 124 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 125 FINISHING WORK 126 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 127 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 128 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including waterthinnable priming coat with cement primer 129 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 130 DOOR & WINDOW WORK 131 Providing & fixing of Alluminium Windows & ventilator inwood finished colour including all necessary T&P withnecessary fittings all complete direction of architect in charge.(Make -Eternia/ Spectrum/ Tostem) 132 Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 133 Frame anchor HRD-C 10x140 134 Frame anchor HRD-C 10x120 135 Providing and fixing double glazed hermetically sealed glazing inaluminium windows, ventilators and partition etc. with 6 mm thick Toughned glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete 136 FLOORING WORK 137 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sqm 138 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying oftiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily Glazed vitrified floor tiles polished finish of size Size of Tile 800 x 1200 mm 139 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar.Red sand stone 140 MISSLENIOUS WORK 141 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqmof cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineerin- Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 142 Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will bepaid separately). 143 Providing & fixing of Puff Panels including all necessary T&P nut bolts, Washer all complete in direction of engineer in charge. 144 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes 145 Supplying & Laying ofwater proof Board including nut bolt washer & including necessary T&P all complete in direction of engineer in charge. Make Ramco Hilux or equvellent 146 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 147 Structural steel work in single section, fixed with or without connectingplate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete 148 Providing and Fixing 15 mm thick densified tegular edged eco friendlylight weight calcium silicate false ceiling tiles of approved texture ofsize 595 x 595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanised steel sections (galvanising@ 120 grams per sqm including both side) consisting of main ‘T’runner suitably spaced at joints to get required length and of size24x38 mm made from 0.33 mm thick (minimum) sheet, spaced1200 mm centre to centre, and cross “T” of size 24x28 mm madeout of 0.33 mm (Minimum) sheet, 1200 mm long spaced betweenmain’T’ at 600 mm centre to centre to form a grid of 1200x600 mmand secondary cross ‘T’ of length 600 mm and size 24 x28 mmmade of 0.33 mm thick (Minimum) sheet to be inter locked at middleof the 1200x 600 mm panel to from grid of size 600x600 mm, restingon periphery walls /partitions on a Perimeter wall angle pre-coatedsteel of size(24x24X3000 mm made of 0.40 mm thick (minimum)sheet with the help of rawl plugs at 450 mm centre to centre with 25mm long dry wall screws @ 230 mm interval and laying 15 mmthick densified edges calicum silicate ceiling tiles of approved texturein the grid, including, cutting/ making opening for services likediffusers, grills, light fittings, fixtures, smoke detectors etc., whereverrequired. Main ‘T’ runners to be suspended from ceiling using G.I.slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mmdia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods withgalvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at1200 mm centre to centre along main ‘T’, bottom exposed with 24mm of all Tsections shall be pre-painted with polyster baked paint,for all heights, as per specifications, drawings and as directed byEngineer-in-Charge 149 Providing & fixing of Centre Pole Umbrella Made in PVC coated Polyster fabric and frame made in stainless steel and powder coated base weight 150 Kg approx and base size 900x900 mm etc including all necessary T&P all complete in direction of engineer in charge .Model Single CENTER POLE UMBRELLASINGLE VOLA ROUND 2.4 mtr x 2.4 mtr SINGLE POLE UMBRELLA Make Loomcraft/ Western outdoor/ Mccoy) 150 WIRING POINTS AND SUBMAINS 151 Point wiring in PVC Conduit 152 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 153 Group C 154 Power plug wiring in PVC conduit (2 x 4 sqmm.) :- 155 Wiring for light/ power plug with 2X4 sq. mm FRLS PVCinsulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 156 Circuit / Sub main wiring in PVC conduit :- 157 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 158 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earth wire 159 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire 160 4 x 6 sq.mm. + 2 x 6 sq.mm. Earth wire 161 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 162 20 mm. 163 S/F light plug point modular type accessories :- 164 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required 165 S/F power plug point modular type accessories :- 166 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 167 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 168 Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches inrecessetc as required 169 1 or 2 Module (75 mm x 75 mm) 170 S/F MODULAR TYPE SWITCH / SOCKET :- 171 Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required 172 Telephone Socket outlet 173 DISTRIBUTIONBOARDS,MCBs, MCCBsANDSFUs 174 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 175 4 way (4 + 12), Double door, horizontal type 176 6 way (4 + 18), Double door, horizontal type 177 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required 178 single pole 179 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 180 40 amps. 181 63 amps. 182 Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required. 183 Supplying and fixing 20 A, 415 V, TPN Industrial type socketoutlet, with 4 pole and earth, metal enclosed plug topalongwith 20 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 184 G.I.EARTHING 185 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 186 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 187 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 188 ERECTIONOFLIGHTINGFIXTURESANDFANS 189 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep 190 Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. CAT- AAA 191 Supply and fixing of 12 Watt to 15 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing with extended heat sink, diffuser of Polycarbonate meterial and driver set complete in all respect. CAT- AAA 192 Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA 193 Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA 194 Supply of AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting frame and other accessories etc.complete 195 300 mm sweep 900 rpm 196 Supply,installation, testing and commissioningof Main DistributionBoard suitable for upto 125 amp FP MCCB incomer and single / three phase outgoing MCBs, IP 43 protection, double metal door, factory fabricated, wall mounting type in surface / recess, powder coated, 415 V / 200 amp copper Bus Bar, earth and neutral bar, removable gland plates, cable glands including connection with outgoing feeders completeinall respect. DBs shall be original factory fabricated of approved make. The rates shall be excluding all incoming and outgoing circuit breakers. 197 8 Way TPN 198 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 199 a) for 110mm dia pipe. 200 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110MM Dia 201 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 202 Concealed work, including cutting chases and making good the walls etc 203 20mm dianominal bore 204 25mm dia nominal bore 205 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 206 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. 207 Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm. 208 Providing, laying and jointing glazed stoneware pipes grade A with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 209 100mm diameter 210 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all roundS.W. pipes including bed concrete as per standard design 211 100mm dia SW pipe 212 Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 213 With Sewer bricks conforming to IS : 4885 214 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. 215 a)White Vitreous China Flat back wash Basin size 550x400 mm with single 15 mm C.P. brass pillar tap. 216 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 217 32 mm dia 218 40 mm dia 219 Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 220 Providing and fixingStainless Steel AISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required: 221 Kitchen sink with drain board 222 510x1040mm bowl depth 250mm 223 CP Brass fittings 224 Providing and fixing unplasticised PVC connection pipe with brass unions 225 45 cm length 226 15 mm nominal bore 227 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 228 a) 15 mm nominal bore 229 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil 230 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 231 50 mm thick Chunar sand stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. Red sand stone 232 First Class M-150 brick work in 1:4 cement and coarse sand mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. 233 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).