| 1 | M & L for Excavating over areas, n exc 1.5 m deep and getting out |
| 2 | M & L for Earth fillings Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5m high from base / Spreading and levelling in layers n exc. 25 cm thick/ Add for well ramming including watering as required |
| 3 | M & L for Cement concrete in foundations, filling and mass concrete type E-2 PCC 1:7:12 (40 mm graded) PCC 1:5:10Reducer 300 mm X 200 mm |
| 4 | M & L for Brick work with sub- class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement Motor ratio 1:4 |
| 5 | M & L for Brick work with sub- class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement Motor ratio 1:4 |
| 6 | M & L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter C/Shuttering |
| 7 | M & L for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like RCC Slab Beam |
| 8 | M & L for Reinforced cement concrete (nominal mix) inFoundations, including rafts, footings, foundation beams; plinth beams; bases for type B1 ratio 1:2:4 (20 mmgraded aggregate) columns, etc.; |
| 9 | M & L for Brick work with sub- class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement Motor ratio 1:4Brick masonry in super structure with CM 1:4 |
| 10 | M & L for Rendering 20 mm thick cement plaste with cement sand ratio 1:4 even or smooth without using extra cement. |
| 11 | M & L for40mm thick brick tiles laid on mud mortar and joints grouted flush tiles are bedded in cement mortar (1:6) or lime mortar (1:3), 15mm thick mixed with 5% of crude oil by weight of cement on mud phuska |
| 12 | M & L for Damp proof course to horizontal or vertical surfaces including necessary formworkin cement concrete 1:2:4 type B0 40 mm including Applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cu. m. per sq. m |
| 13 | M & L for Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) →Paint Work |
| 14 | M & L for 3mm thick wall care putty on wall |
| 15 | M & L including S & F for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally TMT bars Steel Reinforcement Steel Reinforcement |
| 16 | M & L including S & F for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally TMT bars Steel but 6mm to 8 mm dia bars |
| 17 | M & L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match Add to rates for item no for joint free non skid tiles.- Wall Tile |
| 18 | M & L for Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: gear operated type with bevel gear box and crank handle - Rolling Shutter |
| 19 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable sizecomplete. |
| 20 | Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor. |
| 21 | S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc |
| 22 | One light point or one fan point controlled by one switch with cables 1.5 sq. mm size |
| 23 | One 3 pin socket outlet, 5 amps, independent, with cables 1.5 sq. mm size |
| 24 | Supply and fixing Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in surface recessed as required in PVC conduit - 2x2.5 sq. mm + 1x1.5 sq. mm earth wire |
| 25 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required. 150 MM Dia. |
| 26 | M & L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement |
| 27 | Material (supplied only) Supply of Plastic water tank, approved quality |
| 28 | Hoisting and Fixing Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I |
| 29 | M & L Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed dia of pipe 40 mm |
| 30 | M & L gor 40 mm UPVC Pipes (SCH-40) |
| 31 | M & L for PVC 150 MM Pipe |
| 32 | S & F 100 MM Cast iron soil, waste and vent pipes in any length with or without ears, with cement jointst fixed to walls |
| 33 | S & F Bends (any radius), diminishing pieces or tapers (larger bore measured) for bore of pipe 100 mm |
| 34 | S & F Sockets (double) collars for CI pipe, bore of pipe 100 mm |
| 35 | M & L for Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc. complete (Fe 410 -W (Gde E- 250) quality A |