| 1 | Ghantaghar |
| 2 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 3 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 4 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead. |
| 5 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm. |
| 6 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres leadFor thickness of tiles above 25 mm and upto 40 mm. |
| 7 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 8 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all loads including all lifts involved. |
| 9 | Scraping old white or colour wash in incliding disposal of refuse as directed by the Engineert-in-charge within distance of 60mt.(200ft) |
| 10 | shifting of hoarding/ advertisement pole , and stacking of material , nearby suitable pace , complete in all aspects |
| 11 | Excavation in foundation in ordinary soil, loame, clay or sand including lift upto1.5 m and lead upto 30 m including filling watering and rammming of excavated earth in to the trenches or in to the space between the building & the side of foundation trenches or in to the plinth , removal & disposal of surplus earth as directed by the engineer in charge upto a distance of 30 m from the foundation trenches . ( Excluding royalty ) |
| 12 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 13 | First class brickwork in 1:6 cement andcoarse sand mortar in foundation and plinth including supply of all materials, labour and T&P etc. required for proper completion of the work but in the proportion of 1:5 cement and coarse sand |
| 14 | First class brickwork in 1:6 cement andcoarse sand mortar in foundation and plinth including supply of all materials, labour and T&P etc. required for proper completion of the work above but in superstructure, including necessary cutting and moulding of bricks as required and including honey comb brick work, thickness of wall not to be less 1 brick thick. Add extra labour to above items |
| 15 | As in item no. 309 above but for wall of half brick (4½\") thick. Add for extra item over item 309 |
| 16 | Providing and laying in Cement concrete 1:4:8 (1 Cement: 4 approved Coarse sand: 8 Coarse aggregate) size of aggregate shall be 4cm gauge or as approved including supply of all material labor, T&P etc. required for proper completion of the work. |
| 17 | Design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works above plinth level upto floor level |
| 18 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 19 | Columns, Pillars, Piers, Abutments, Posts and Struts sqm |
| 20 | Suspended floors, roofs, landings, balconies and access platform |
| 21 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level/ above |
| 22 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). ss. tube |
| 23 | Mild steel or iron work in heavy sizes such as trusses, built up gates, door, frames, record racks roof work, gate etc. wrought to required form including drilling holes, rivetting or welding where necessary, and also including supply of steel, bolts, nuts etc. & their fixing required for proper completion of the work. |
| 24 | For Wire mesh |
| 25 | 12 mm Thick plaster with kankar lime over brick minimum thickness not to be less than 3/8\" (10mm) thick including supply of all materials, labour and T&P etc. required for proper completion of the work but with cement and coarse sand mortar(1:6) |
| 26 | Add for extra labour and material for plaster over rough face of brick walls |
| 27 | Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm (Approved makes: Berger,Asian paints, Nerolac) |
| 28 | Neat cement Punning |
| 29 | 1:3 (1 cement : 3 fine sand) |
| 30 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 31 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 32 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 33 | Unistone Terracota Tile Cladding |
| 34 | Providing & Fixing of \"UniStone\", Glass Reinforced Concrete (G.R.C.) Screens casted with \"Spray Mix\" concrete design in approved size, pattern, thickness and shade. Border Thickness: 40-50mm Inner membrane: 25-30mm OR Overall 35mm thick seamless module pattern |
| 35 | Providing and laying factory made chamfered edge Cement Concrete paver blocks/Cobble Stoneinfootpath,parks,lawns,drivewaysorlight trafficparking etc, of required strength, thickness & size/ shape, made bytable vibratory method using PU mould, laid in required colour &pattern over 50mm thick compacted bed ofsand, compacting andproper embedding/laying of inter locking paver blocks into the sandbedding layer through vibratory compaction by using plate vibrator,filling the joints with sand and cutting of paver blocks as per requiredsize and pattern, finishing and sweeping extra sand. complete all asper direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour,design & pattern. |
| 36 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 12 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :sand stone - exposed face fine dressed with rough backing30 mm thick |
| 37 | Providing and laying gang saw cut 18 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick baseof cement mortar 1:4 (1cement : 4 coarse sand) including groutingthe joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. |
| 38 | 1800mm Round/ Square _Customised Analog Clock Standalone Heavy duty Tower Clock GPS Enabled auto plug & play single face, clock suitable opning in the wall, Electro- Mechanical Movement made with weather-proof high precision hard and rust free Stainless steel and Brass wheel, instead of Plastic Chinese Movt. In the event of power cut this should be automatically switchover to battery back-up. The On-line battery back-up upto 120 hrs. time. If the power cut prolongs even beyond 120 Hrs. time, than the tower clock will stop working but as soon as the electric power comes back, than the clock should come to the right time with the help of GPS time signals received from the satellite. The clock should be totally automatic in functioning. No manual time setting required with auto charging – high charge and deep discharge protection. |
| 39 | DIGITAL BELL/ STRIKE/ CHIME SYSTEM with 2 Speaker Ampliefier Automatic System Hourly clock Chime_ Striking automatic GPS Enabled system, Out of 24 Chime/ Strike every strike Enable or Disable facility, automatic ON & OFF Amplifer, Speaker system. Providing : - Analog Complete GPS Enabled auto adjust Complete Movement. - GPS Device. - SOLAR Compatable (Easy to connect direct SOLAR PANEL without Solar Panel) - Controller with 120 Hours On-Line backup with auto charger. - Ttranslucent DIAL_ METAL FRAME_ Minute and Hour Hands Metal bushes with screw. - Automatic ON & OFF switching for LED backlit for night Dial illuminate viewing.(including charges of packaging,transportation and installation) |
| 40 | Fabrication, supply of Ozone make Flag Signage, having the double side openable backlit signage of size 4\"-4\" (L)x 6\"-0\" (H), Signage shall be suppoted on SS-304 grade pole of 6\" dia with MS base plate, The overall height sall be 15\" 6\" from FFL. On the top & bottom the laser cut mirror finish decoratiove crown/vectoria corners shall be made in SS 304. (Note: Manufacturer shall have the own Lasercut machine bidder need to upload invoice of machine at the time of bidding). The side signage frame shall be made of 6063-aluminum frame with section weight 5.3 to 5.5kg/m with minimum tensile strength 22000 psi, The front frame shall be cladded by SS-304 grade sheet on both side as per drawing provided having 4mm clear solid compact polycarbonate on both side and reinforced with internal support frame, completely sealed with the help ofsilicon and EPDM to make it dust and water proof. Should have the inbuilt STRONG clipping and frame arrangement for holding the flex of digital media alongwith all necessary cleats and corner joinery require to build the signage with sufficient strength. The aluminum frame should have polyester powder coating with minimum thickness of 60 micron. (Note: The Bidder need to provied own Powder coating machine/paint shop of the manufacturer). The Internal led light of 22W LED Tube with batten (HELONIX, ORIENT, PHILIP, OSRAM, HAVELS) shall be fixed 2 nos Led light on all four sides total 8 nos led light sahall be fixed inside the signage including the all required wiring and1 no. MCB for NO/OFF provision. Main source of current and connection to MCB of this signage shall be the client responsibility.) Installation, J Bolt/ Fastner as per approved make charges excuding of matrial frieght.The stand alone signage shall be fixed on RCC 1:2:4 Footing Block with bottom PCC bed of 1:4:8 ratio with fastner or \"J\" Bolt as per satisfactory by site encharge. |
| 41 | Stone Etching Portrait |
| 42 | Dustbins |
| 43 | Placard Signage (Make Ozone) |
| 44 | Materials shifting |
| 45 | Electrification works @10% of civil cost |
| 46 | Add cosultancy |