Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. |
| 2 | Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification. |
| 3 | Supplying and filling in foundation, basement, etc with filling M-Sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 4 | Refilling with excavated earth other than M-sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officersin layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification. |
| 5 | Supplying and filling of gravel by lorry in basement filling including conveyance loading and unloading charges and all other incidential charges filling laying watering and consolidation etc., complete as directed by the Department Officers with standard specification. |
| 6 | Cement Concrete 1:5:10 (One Cement, Five M-sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundationincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification. |
| 7 | Cement Concrete 1:5:10 (One cement, Five M-sand and Ten hard broken stone) using 40 mm gauge hard broken jelly for flooring including laying,consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification. (The rate is inclusive of necessary planking for panellingwherever necessary and as directed by the departmental officers. |
| 8 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid) |
| 9 | Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) |
| 10 | For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc. |
| 11 | For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. |
| 12 | For plane surfaces such asrectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc. |
| 13 | Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part thereof but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers. |
| 14 | Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kg/mᶾ and maximum water cement ratio of 0.50, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers.The coarse and fine aggregates to be used should comply with the requirements of IS Standards.(No separate payment will be made by the Department for the excess usage of materials). |
| 15 | For Foundation and Basement |
| 16 | For Superstructure in Ground floor |
| 17 | For Superstructure in First Floor |
| 18 | For Superstructure in Second Floor |
| 19 | For Superstructure in Third Floor |
| 20 | For Superstructure in Fourth Floor |
| 21 | Providing and laying in position, Standardised Concrete Mix M-20 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/mᶾ and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers.The coarse and fine aggregates to be used should comply with the requirements of IS Standards.(No separate payment will be made by the Department for the excess usage of materials). |
| 22 | For Foundation and Basement |
| 23 | For Superstructure in Ground floor |
| 24 | Cement Concrete 1:3:6 (One Cement, Three M-sand and Six broken stone jelly) using 40mm size hard broken stone jelly for dummy columns, excluding cost of centering shuttering reinforcement grills and fabrication charges but including curing etc. complete. (Reinforced Cement Concrete 1:2:4 for slab to be extended upto top of splashing with pressed tiles and future extension rods to be embedded in CC 1:3:6 (One Cement, Three M-Sand and Six hard broken stone jelly).Dummy columns should be at least 1 metre height) |
| 25 | For Superstructure in Third Floor |
| 26 | Plain Cement Concrete 1:2:4 (one cement, two m-sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specifications and as directed by the departmental officers. |
| 27 | For Foundation and Basement |
| 28 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification.(Contractor has to make his own arrangements for the supply of steel and binding wire) |
| 29 | Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. |
| 30 | For Superstructure in Ground floor |
| 31 | For Superstructure in First Floor |
| 32 | For Superstructure in Second Floor |
| 33 | For Superstructure in Third Floor |
| 34 | For Superstructure in Fourth Floor |
| 35 | Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three M-Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers. |
| 36 | Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of \"U\" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification. |
| 37 | 160mm dia PVC Pipe (Two Floors ) |
| 38 | Brick work inCement Mortar 1:3 (One cement and Three M-sand) using Fly Ash Bricks of 230 x 110 x 70mm size conforming to IS: 12894-1989 Class designation not less 50 kg./ sq.cm. average compressive strength in cement mortar 1:5 for load bearing structures for foundation and basement and for superstructure including curing, etc., complete complying with standard specifiction. |
| 39 | For Foundation and Basement |
| 40 | For Superstructure in Ground floor |
| 41 | Brick work inCement Mortar 1:5 (One cement and Five M-sand) using Fly Ash Bricks of 230 x 110 x 70mm size conforming to IS: 12894-1989 Class designation not less 50 kg./ sq.cm. average compressive strength in cement mortar 1:5 for load bearing structures for foundation and basement and for superstructure including curing, etc., complete complying with standard specifiction. |
| 42 | For Foundation and Basement |
| 43 | Brick work inCement Mortar 1:6 (One cement and Six M-sand) using Fly Ash Bricks of 230 x 110 x 70mm size conforming to IS: 12894-1989 Class designation not less 50 kg./ sq.cm. average compressive strength in cement mortar 1:5 for load bearing structures for foundation and basement and for superstructure including curing, etc., complete complying with standard specifiction. |
| 44 | For Superstructure in Ground floor |
| 45 | For Superstructure in First floor |
| 46 | For Superstructure in Second floor |
| 47 | For Superstructure in Third floor |
| 48 | For Superstructure in Fourth floor |
| 49 | Brick partition walls of 11.50cm thickness using best quality Fly ash Bricks of size 230x110x70mm in Cement Mortar 1:3 (One Cement and Three M.Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) |
| 50 | For Superstructure in Ground floor |
| 51 | For Superstructure in First Floor |
| 52 | For Superstructure in Second Floor |
| 53 | Damp proof course with Cement Mortar 1:4 (One Cement and Four M-sand) 12mm thick mixed with best approved quality water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used and finishing, curing etc. complete complying with standard specification. |
| 54 | Plastering with Cement Mortar 1:5 (One cement and Five M-Sand), 12mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equivalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 55 | Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three M-Sand) 10mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equivalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers. |
| 56 | Plastering with Cement Mortar 1:3 (One Cement and Three P-Sand) 20mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers. |
| 57 | Plastering with Cement Mortar 1:4 (One Cement and Four P-Sand) 20mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers. |
| 58 | Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination byrubbing with wire brush.Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier.The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed.Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface.After drying, second coat shall be applied on the first coat as directed by the departmental officers.The rate inclusive of cost of materials and labour, etc., complete. |
| 59 | Supplying and fixing following Ornamental Burma Teakwood entrance door as per the drawings and designs approved by the departmental officers .The size of the opening is 4.80x3.90m. The outer frame of the door is 150mmx125mm teakwood. The main door shutter opening size is 3.00mx3.00m.The main door should be double leaves and each door shutter fully panelled.The door shutter outer frame of size 150mmx50mm teakwood. The door panells shall be of 50mm thick teakwood planks with ornamental designs approved by the Executive Engineer. The Lock rail shall be of 200x50mm tk teakwood. The top of the door to a height of 900mm finished with fixed glazing of approved pattern using 12mm thick toughened glass with MS grill. the sides of the door shall be fixed glazing of size 900mmx3900mm finished with 12mm thick toughened designed glass. All the door frames and fixed glazing frames are made out of 150mmx125mm teakwood of best quality. The door frames and shutters shall be given two coats of best approved quality melamine finish. The rate inclusive of cost of approved quality teakwood, 12mm thick designed toughened glass, brass hinges, brass tower bolts, brass aldrops, door stoppers, brass screws etc.,The cost includes cost of material, labour charges, conveyance charges, fixing charges,designing charges and glass design charges, electricity charges and all other incidental charges., etc. All materials should be got approved by the Executive Engineer before use on works. |
| 60 | Supplying and fixing in position Stainless steel door frameas per I.S.4351/1976 of size 105x60mm with 35x12mm rebate on all sides with 1.00 mm thick (18 gauge) sheet frames special profile extruded section including bottom tie hold faste at appropriate placesand provision to fix aldrops tower bolts hinges and lock strike plate etc.The door frame inner shall be packed with CC 1:2:4 using 12mm guage HBG stone jelly including fixing the door frames inposition and dimantling the masonry and concrete wherever necessary and redoing the same original condition after fixing including scaffolding charges and labour charges and door frame will be given one coat of Red Oxide primer etc. Complete complying with standard specification The rate shall inclusive of all materials, labour, transportation, loading, unloading, handling, charges etc. The sample of materials should be got approved by the Exe. Engineer before use on works. |
| 61 | Supplying and fixing of Solid Core Flush Shutters with teak plywood on both side with teak wood lipping alround 35mm thick confirming to IS.12406/1989 with 35x12mm T.W.lipping on all edges with necessary adhesive and C.P.Screws, including fixing of aldrops, tower bolts, hinges and lock strike plates, putty, fevicol, varnish for T.W.lipping thinner colouring agent etc., and aluminium anodised 12m size hinges 3 nos best quality of aluminium anodised fittings of 200mm, towe bolt 150mm 1 no, 20mm aldrops 16mm dia rod 1 no 125mm long handle 2 nos 40mm dia nylon bush 1 no, door stopper 1 no shall be provided. The rate is inclusivecost of fevicol and fixing charges, transportation, loading, unloading and all other incidential charges, handling charges etc., complete comlying with standard specification. |
| 62 | Single leaf |
| 63 | Supplying and fixing of Solid Core Flush Shutters with teak plywood on both side with teak wood lipping alround 35mm thick confirming to IS.12406/1989 with 35x12mm T.W.lipping on all edges with necessary adhesive and C.P.Screws, including fixing of aldrops, tower bolts, hinges and lock strike plates, putty, fevicol, varnish for T.W.lipping thinner colouring agent etc., and aluminium anodised 12m size hinges 3 nos best quality of aluminium anodised fittings of 200mm, towe bolt 150mm 1 no, 20mm aldrops 16mm dia rod 1 no 125mm long handle 2 nos 40mm dia nylon bush 1 no, door stopper 1 no shall be provided. The rate is inclusivecost of fevicol and fixing charges, transportation, loading, unloading and all other incidential charges, handling charges etc., complete comlying with standard specification. |
| 64 | Double Leaves |
| 65 | Supplying and fixing FRP door frames of size 65x50mm and FRPflush type shutter of over all thickness of shutters 35mm with two core filling eigther with agro based materials or with fiber proof firm in case of light weight and with quality seasoned and treated hard wood cleats wherever found necessary for fixing furniture fittings and with necessaryrebate for hinges with colour pigments and casing good quality fiberglass materials G.F. resine thickness of F.R.P. being 3mm with fiber glass matt resin at 1:2 ratio by weight.The sample of materials should be got approved by the Executive Engineer before use onwork. |
| 66 | Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle.The corners and joints should be welded and cleaned.Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong lockingsystems and as per size for arresting noise and energy loss.The connecting mechanism between sash and outer frame that enables opening of the window.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.The window should be got approved from the Executive Engineer before use on work. |
| 67 | Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profilethe size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles arereinforcedwith GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of2mm.The EPDM rubber (black colour) covered with all over the edges of frame and shutter.The corners and joints should be welded and cleaned.Radiations pin headed glass 4mm thick should be provided in the louvers.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work. |
| 68 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between.The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete.The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete. |
| 69 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing.The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade.The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete. |
| 70 | Supplying and fixing of M.S.grill of approved design for grill gate, grill work to doors and windows openings ramp etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification. |
| 71 | Manufacturing, supplying and fixing in position of MS steel windows (Three Leaves)with 4mm FRP transparent sheets instead of glass panes with the following specifications. Outer frames of windows made of \"Z\" section F7D of size 33 x 25 x 3 mm at 1.419 Kg/m and mullion \" O \" section (F4B) of size 46 x 25 x 3 mm at 2.28 Kg/m and shutter section made of F7D of 33 x 25 x 3 mm at 1.419 Kg/m as specified in IS 7452/1990. Each openeble shutter should not exceed a width of 600 mm to enable separate operations and easy maintenance. The panel of the shutter to be covered with 18 Gauge cold rolled sheet of superior quality and welded intact with shutter frames. horizontal stiffeners using 18 x 5 mm MS Flat at all four corners of each shutters to the suitable length welded to the shutters for holding the CR sheets in position firmly. Two numbers of sturdy hinges and one number of handle-cum-latch of special type made with 18 x 5mm MS Flats are rivetted to the shutters at an appropriate height in window. Suitable opening in left for its easy operation. A stopper square rod for handle is provided in the mullionsection at suitable placeto catch the window handle. Each window shutter having an adjustable position. a matching peg is provided in the outer frame of the window at suitable place. |
| 72 | Manufacturing, supplying and fixing of Steel doors with following specification.MS angle of size 40x40x6mm at 3.5 kg/m used for outer frame and MS Angle of size 35x35x5mm at 2.6 Kg/m for the shutter frame.Stiffeners with 32x6mm at 1.5 Kg/m MS Flat is provided as the lock rail of the door and welded intact on both ends to the shutter frame. 18 G CR Sheets of best quality is laid as panel in the shutter frames.18x5mm at 0.70 kg/m MS flat is welded over the 32x6mm at 1.50kg/m MS Flat on the rear side of the door, sandwitching the CR Sheet for rigidity.Additional stiffeners with 18x5mm at 0.7 Kg/m MS flats are provided diagonally on the rear side of the shutter.300mm length of hinges 2 Nos, for shtter is provided.6 Nos.of 250mm length hold fasts 200mm length specified at the ends are welded to the outer frame of the door. Tower bolt 2 Nos. at the top provided.250x16mm size of Two aldrops are provided in single leaf door at lock rail section in the door for inner and outer provided and one rotating locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear sideof the door at an appropriate place and 1 No. of M.S. handle of heavy duty. A tie bar is provided at the bottom of the outer frame to prevent twisting of the frame during transportation and fixing.All members are given one coat of red oxide primer as directed by the departmental officers.The rate includes cost of all materials, labour charges, transportation, taxes and all other incidental charges, etc., complete. |
| 73 | Single Leaf |
| 74 | Supplying and fixing of rolling shutters shall be pull and push type made of 18/Gx3\" lath sections which consist of five main parts such as curtain, lock plate, guide channels rollers and hood cover.These five main parts are made out of special components detailed below:Curtain shall be of 18/Gx3\" lath sections cut to required size and filled with heavy cast iron / MS clips.For 8\" 0\" (2.45m) high rolling shutter lath sections provided shall be not less than 37 numbers.Lock plate shall be of 10 GMS sheet reinforced with 40mm x 6mm MS angles at the bottom and fitted with heavy latches and locking arrangements on either sides.There should be one handle on either sides. Guide channel pressed guide channels shall be 10GMS sheet and attached to the side brackets with 20mm square bar.Side brackets shall be of 10G MS plate and cast iron \"U\" clamps shall be rivetted to the side brackets.Roller shall be of heavy cast iron pullies fitted with heavy duty \"C\" class 40mm steel pipe and high tensile high carbon coil springs. 2 springs shall be supplied.Side brackets shall be of 10G MS plate and cast iron \"U\" clamps shall be rivetted to the side brackets.Roller shall be of heavy cast iron pullies fitted with heavy duty \"C\" class 40mm steel pipe and high tensile high carbon coil springs - 2 springs shall be supplied.Hood cover shall be of 0.8mm CRCA sheet reinforced with 25mm x 25mm x 3 mm MS angle or gate channel.The rolling shutter in addition to the above should have pulling hook and shall be coated on exposed area with heavy coat of red oxide primer. |
| 75 | Gear Operated |
| 76 | Supplying, fabricating and fixing in position factory made Stainless Steel Flush Door Shutter 35mm thick using SS 304 Grade 1.6 mm thick, Stainless Sheets on both sides (Equivalent to IS 6911-04 Cr. 19, Ni 9) minimum 8-8.5% nickel and 18% chromium sourced from original stainless steel manufacturer with view panel size 30mm x 45mm made up of 6mm thick clear toughened glass fitted with double side adhesive tape and finished with dowconing silicon sealant, floor spring for each shutter, consealed tower bolt, suitable stainless steel locking arrangement and other necessary furniture fittings of approved quality. The vertical styles and other frame members and cross stiffeners shall be of same quality stainless steel box section of suitable size and thickness with proper core material as prescribed by the Departmental Officers. |
| 77 | Dadooing walls with Colour designed digital print ceramic tiles, with borders, with size of 300mm x 600mm x 10mm and above set in Cement Mortar 1:2 (One Cement and Two M-sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc,,complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be like Johnson / Kajaria / Somany / Nitco / RAK or Equivalent which has to be got approved by Executive Engineer before use on works) |
| 78 | Dadooing Granite walls Tiles with following best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two M-sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. |
| 79 | Supplying and fixing of Stainless Steel False Ceilingetc., complete complying with standard specification. (The False Ceiling should be got approved by the Executive Engineer before use on works) |
| 80 | Supplying and fixing of SS Wall Claddingetc., complete. |
| 81 | FLOORING - Providing vinyl flooring 3.00mm anti-static seamless PVC flooring thick. The floor shall be smooth, non-slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock., it shall be electro static discharge (ESD) combat PVC seamless flooring of very high-quality thickness not less than 2.00mm. Continuous roll shall be used and with minimum joints. The joint’s to be welded by special PV thermal unit’s using PVC welding bars of same colours. The sheets shall be highly durable to shock and in dentation. The flooring shall be done by skilled workers of the accredited agencies authorised by supplier of PVC sheets. The electrical resistance (Point to ground) shall be within 2.5 x 104 to 5 x 106 Ohms. The floor shall not allow build-up of electrical charges beyond 100V due to anti-static effect. The corners shall not be terminated sharply & concealed coving shall be used to overlap the wall panel to a height of approx. 25mm & sealed perfectly – uniformly. Self-levelling compounds shall be used. The copper strips to be made visible by grinding and no copper strip shall project more than 0.5mm above level surface to avoid damage to the PVC sheet. One earthing lead shall be brought out from every 150 square feet area and attaching it to the main earthing strip / ground. Copper grounding strips (0.05mm thick, 50mm width) shall be laid flat on the floor in the conductive adhesive and connected to the copper strip of grounding. The connection from copper grid shall be brought out uniformly at places to form equi-potential grid. The flooring shall be mechanically shocking proof, scratch proof, flame retardant and antimicrobial. The floor shall efficiently discharge electric up to 2 KV. The floor shall offer electrical resistance., The final surface shall be noncorrosive to biological fluids & detergent’s, shall be fire retardant, antimicrobial, colour shall be uniform, pleasant & matching with ambience etc., complete complying with standard specifications. |
| 82 | Paving the floor with best quality Double Charged Vitrified Tiles of size 800 x 800 x 10 mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three M-sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 83 | Granite tiles of lapotra of suitable sizeswith machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One Cement and three M-sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. |
| 84 | Providing full nosing to the steps or platforms to the Granite slab of 20mm thick including neat finishing, polishing, cost of powder, tools etc as directed by the departmental officers. |
| 85 | Flooring with Joint free Rectified Glazed Ceramic Tiles 305 x 305 x 8mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three M-Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 86 | Providing granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two M-sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panellingwherever necessary and as directed by the departmental officers) |
| 87 | For 25mm thick |
| 88 | For 40mm thick |
| 89 | Supplying and fixing fine polished cuddapah slab of 38 / 40mm thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as direct. |
| 90 | ProvidingCup-boardShutterusingtermite/waterproof plywoodof19mmthickoverwhichlaminatedsheetof 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Departmental Officers. The design pattern, water proof plywood,laminatesheetandothermaterials shouldbe got approved from the Executive Engineer before use on work. |
| 91 | Supplying and applying of Two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothly with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing.The surface shall then be allowed to dry for atleast 48 hours.It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface.Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the departmental officers.(The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (water proof abrasive sheet) cost of putty blade, labour charges for grinding the joints and sand papering, two coats of putty, scrapping the putty area to level the surface smooth, etc., complete). The putty should be got approved by the Executive Engineer before use on work. |
| 92 | Supplying fixing and errecting of steel roof trusses and roof truss purlins fixing for G.I. sheet roofing using MS. L. angle of size 50x50x6 mm raffter, Tie angles and MS angle of size 50x50x6mm for sturts and MS plat of size 12 mm thick for fixing G.I. sheet. The purlins using MSL. angle of size 50x50x6 mm shall be properly anchored to the supporting super structure and fixed in concrete at wall and spacing of purlins are to be arranged to use the standard size or sheet and spacing should not execeed 1680 mm and free over hang at eves should not be more than 400 mm, the cleats shall be wellded to the trusses firmly and fixed on the down stream side of purlins.The ridge purlins fixed at 77 to 115 mm away the apex of the roof. The trusses shall have welded joints only at all guessets plate junctions except gussets at bottom chords to have bolts and nuts to permit transportation of trusses as directed.The foundation anchor bolts of trusses will be fixed in concrete at wall in bed blocks and well cured, labour for erection of trusses of approved quality transportation, priming coat for all members, cutting, bending, and welding etc.,The trusses should be connected at bottom 1 / 3 part by steel tie angles and with top and bottom wind bracings as per design given.The chord of the trusses of bottom channel should suitablely cambered.The truss and purlinsshould be given priming coat of Rex Oxide primer of approved quality including labour for erection, transportation, wellding etc., complete complying with standard specification. |
| 93 | Supplying and fixing colour galvanum sheet roof of 0.47mm thickand steel tubular box section of 100x50x3mm of 1meter interval including priming coat fixing in position with all necessary accessories complete complying with standard specification and as directed by the departmental officers. |
| 94 | Supplying and fixing in position steel balustrades using 20mm square rods spaced at 150mm centre to centre so that the two balustrades in each step shall be placed centrally and the top of balustrades connected with the hand rails (cost of hand rail shall be measured and paid separately) by means of MS flats of size 40mm x 6mm in the groove 40mm x 6mm provided at the bottom of hand rail; the bottom of balustrades shall be fixed on to the top of step concrete.An additional MS flat of size 50mm x 6mm shall be provided at the centre of balustrades connecting all square rods to the entire length including cost of square rods, flat and applying one coat of red oxide primer to the iron surfaces, etc., complete complying with standard specification and as directed by the departmental officers. |
| 95 | Supplying and fixing 40mm dia GI pipe for staircase hand rail including labour charges for cutting, welding and fixing with MS flats (excluding cost of flat), etc., as directed by the departmental officers. |
| 96 | Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. |
| 97 | Painting two coats of newly plastered wall surface with ready mixed Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. |
| 98 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 99 | Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 100 | Polishing the teak wood door with two coats of best French (Lac) polish with approved quality and brand over a coat of bee\"s waxing including preparing the wooden surface to receive polishing, etc.,complete complying as per the standard specifications. (The make, quality and colour of french polish, bees vax should be got approved by the Executive Engineer before use on works.) |
| 101 | Supplying and erecting in position of 500 litres capacity Industrial Model Reverse Osmosis Water-cum-Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. (a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set(c) Feed Pump 0.50 HP – 1 No.(d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No.(e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos.(f) Flow Meter - 1 No. 20” Filter with Housing - 1 No., Low Pressure Switch - 1 No., Level Switch - 1 No. & Necessary CPVC Pipes and Fittings.The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc.The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact. |
| 102 | Supplying and erecting in position of 250 litres capacity Industrial Model Reverse Osmosis Water-cum-Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. (a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set(c) Feed Pump 0.50 HP – 1 No.(d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No.(e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos.(f) Flow Meter - 1 No. 20” Filter with Housing - 1 No., Low Pressure Switch - 1 No., Level Switch - 1 No. & Necessary CPVC Pipes and Fittings.The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc.The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact. |
| 103 | Providing Pre construction Anti termite treatment for the building including all chemicals as per standard specifications. Labour charges for preparing the areas for treatment spraying chemicals and other incidential charges etc., complete. The rate shall be inclusive ofgiving anti-termite treatment to the building for the following four stages including breaking the termite mounds making holes with crow bars at an intervel of 12\"to a depth of 8\" in the periphery of building and pouring chemicals etc., complete as per ISI 6313-1981 and. The antitermite chemicals used should have 0.5% concentration with 3L solution for the entire operation etc. as directed by the Engineer incharge and including cost of chemicals labour transportion etc., Stage:1 Spraying Anti-termite treatement chemicals solution for the foundation before laying the foundation concrete bottom and sides of the foundation.Stage:2 Spraying anti-termite chemicals solution to the grade beams level spraying has to be done for the grade beams brick masonry in the superstructure in contact with back fill earth.Stage:3 Spraying anti-termite chemicals solution on sand for the flooring before laying the flooring concrete. The treatment has to be carried out on the sand filling the basement after leveling operation is over.Stage:4 Spraying anti-termite chemicals solution around the building outside of the building by making crow bar holes at an intervel of 12\" to a depth of 8\" around the building before laying the plinth projection.This holes has to be be closed after the treatment. |
| 104 | Supplying and Fixing of English Brass Letters of approved size and colour.The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes. |
| 105 | 25 cm size |
| 106 | Emblem (15\") |
| 107 | Supplying and Fixing of Tamil Brass Letters of approved size and colour.The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes. |
| 108 | 25 cm size |
| 109 | Paving the floor with Tactile Paver Type of New Tek BT Yellow Colour Ceramic Tiles of size 305 x 305 x 15mm for Vision Impairment Person of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three M-Sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg/sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works). |
| 110 | Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two M-sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed. |
| 111 | 50mm thick precast slab using 20mm HBGS jelly |
| 112 | 75mm thick precast slab using 20mm HBGS jelly |
| 113 | Supplying Fabricating and placing in position of Aluminium natural colour matt finish fixed Partition with 5.50mm thick plain glass the outer frame of the Aluminium section of size 101.60x44.45x3.18mm @ 2.319Kg/m. at internal vertical 2 Nos & Horizontal 1 No, mullion of aluminium section of size 62 x 38 x 2mm @ 1.174 Kg/m with necessary aluminium clips of size 79.15 x 17.27 x 1.50mm at 0.176 Kg/m with necessary rubbor beading L angles including dismantling and redoing masonry as concrete where necessary etc., complete.The Aluminium section are to be anodised with matt finish under electrically controlled condition in allfdjsfdslk with ISI 1868 / 1962 specification for an average anodie film thickness of not less than 15 microns.All aluminium sections are should be got approved by Executive Engineer before use on works. |
| 114 | Supplying and fixing in position aluminium anodised fully glazed door and frame made out of box section 101.6x44.45x3.18mm thick at 2.319 kg\m door shutter made out of box section 47.1x44.45x2.5mm at 1.202 kg\m for vertical style and top, lock rail sections of size 50x44.50x2.5mm @ 1.292 Kg/m and bottom 100.4x44.45x2.50mm at 1.974kg\m using clips of size 17.15x17.27x1.5mm at 0.176 kg\m with necessary metal screws, rubber beading, strike plate type handle ofsize 100x30x1.60mm at 0.988 kg\m on both sides, tower bolts, lock pivot arrangements with5.50 mm thick Plain glass with 1 No. of hydraulic door closers of approved quality using aluminium extruded section body tubler type universal with double speed adjustment with ISI monogram including cost of furniture fitting such as Pivot, hinges, Tower bolt, lock, door stopper and all materials labour power consumption required for fabrication drilling required for fabrication drilling holes in RCC columns floorslabs masonry wall wherever necessary with power drills to the required extent and make the same to original condition after fixing and as directed. All the aluminium sections are to be anodised with matt finish under electrically controlled condition in accordance with IS 1868-1962 for an average anodic flim thickness of 15 microns etc., complete. The materials should be got approved by the Engineer incharge before use on works. The rate shall be inclusive of all materials, labourfor fixing transportation loading, unloading, and all other incidential charges. |
| 115 | Gas Outlet Points: (Self sealing type - Single / DIN outlet pipe) with \"S\" type bracket made up of copper and the out let of non-interchangeable for other gas. The outlet points are brazed with brass bracket with self sealing valve (Stainless Steel) with all accessories and complete set and are covered by plastic cover duly colour coated as per specific gas and button cover etc., complete as directed by the Departmental Officers and as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification. |
| 116 | Medical Gas Copper Pipeline arrangement to hang on the wall of socket type connection installation of seamless cleaned and degreased non arsenical phosphorous gas copper pipe line with saddles complete with brazing work including all copper fitting (tee, elbow, reducer, coupling). The copper pipelines should be tested suitable for a steam of working pressure of 17.34 kg. / cm2 (17 bar) and confirm to BS 864 Standard with specially made for brazed socket type connection.The medical gas copper pipeline should be tested as per standard and commissioning after painting as per International Code No. IS 2379/1963 Table-V.The pipelines installed at the various wings and floors etc., complete as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification. |
| 117 | 28mm OD 0.90 mm Thick Copper Pipe |
| 118 | 22mm OD 0.90 mm Thick Copper Pipe |
| 119 | 15mm OD 0.90 mm Thick Copper Pipe |
| 120 | 10mm OD 0.90 mm Thick Copper Pipe |
| 121 | Brass Isolation Valve suitable for the copper pipe and should be of non lubricated 90 degree turn lever ball valve of reputed make, conneced in line with medical gas pipe line system by using suitable size brass valve adopter union, ferrule, nipple, rubber \"O\" ring, tapion lap and etc.All pipe line regulators shall be capable of controlling pipe line pressure and must compatible with the requirements specified in IS 12827-1989. All valves should be pneumatically tested for twice the working pressure for the gas line as per IS Code 12827 / 1989 & ISO 7396 / 1987 Sepecification. |
| 122 | 28mmIsolation Valve |
| 123 | 22mmIsolation Valve |
| 124 | 15mm Isolation Valve |
| 125 | Oxygen manifold arrangements of 2 banks x 12 cylinder each wing with semi automatic control panel which includes contact gauge 2 Nos., outlet pressure gauge, brass heavy duty IO x regulator 2 Nos. with suitable adopter, flexible SS Hose. Mainfold shall be of a construction and of a designs and material suitable for the service pressure in accordance with IS 1282-1989.Emergency alarms with illuminating display for low / high pipeline pressure and malfunctioning of system. 1) Mainfold top frame with provision for connecting 12 cylinders on right bank and 12 cylinders on left bank with high pressure interconnecting copper tubing, silver brazing, non return valve, fasteners and cylinder spport middle angle frame for claping 2 x 12 cylinders and related fasteners.The O2 manifoldshould with stand a pressure of 140 kg. / CM2.The installation is commissioned after testing as per standards and painted as per International Code and as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification. |
| 126 | Nitrous Oxide Manifold Arrangements of 2 banks x 3 cylinder each wing, with automatic control panel which includes contact gauge 2 Nos., outlet pressure gauge, brass heavy duty IOX regulator 2 Nos. with suitable adopter, flexible SS hose. Mainfold shall be of a construction and of a designs and material suitable for the service pressure in accordance with IS 1282-1989. Emergency alarams with illuminating display for low / high pipeline pressure and malfunctioning of system.1) 2 x 3 cylinder Nitrus Oxide Manifold should be suitable with stand a pressure of 140 Kg. / Cm2 and above along with high pressure copper annealed tail pipes with end brass adapter suitable for Nitrous Oxide Cylinders and manifold.2) Top frame comprising of high pressure copper pipes of size 12mm ID 1.5mm wall thick with high pressure brass fittings made of high tensile brass and connections through non-return valves, high pressure copper tail pipes made of high pressure copper pipe size of 7mm ID x 1.5mm thick. 3) The design of middle and bottom frames should be provided to fit both round and flat bottom cylinders safely with fitted heavy duty regulator. The Manifold should be tested at 3500 pig as per IS 12827 / 1989 & ISO 7396 / 1987 Specification. |
| 127 | Flow Meter made up of Brass with Humidifier Bottle Flow Meter should be back pressure compressed and should be accurate gas flow measurement with control range 0-13 litres per minute.It should meet strict permission and dumbling standard.The meter body should be made of brass materials.The humidifier bottle should be made of unbreakable polycorbonate material and auto cleavable at 134 degree centigrate.The rate includes flow meter and its accessories (silicon tube with mask). The cost of materials including transport, etc., complete as per standard specification and as directed by the Departmental Officer and as per IS 12827 / 1989 and ISO 7396 / 1987 Specification. |
| 128 | Ward Vaccum Unit with Gauge both mounted on a collection jar of capacity 600 ml and with a wall bracket for mounting it on the wall.The collecion jar should be made of unbreakable polycarbonate materials which is fully auto cleavable at 134 degree centigrade as per standard specification and as directed by the Departmental Officers and as per IS 12827 / 1989 and ISO 7396 / 1987 Specification.The rate includes cost of silicon hose with SS nipple on either side. |
| 129 | Supply, installation, testing and commissioning of equivalent to Ingersoll Rand Reciprocating Air Cooled Type (10 HP + 5 HP) rating Vaccum Pump as per following provisions. As per IS 12827 / 1987 & ISO 7396 / 1987 Specification a) Vaccum pump - 10 HP - 1 set b) Electric motor - 5 HP -1 No.c) DOL Starter with OLR - 1 No. d) Vaccum switch - 1 No.e) Vaccum Gauge - 1 No.f) Control Frame with Fittings - 1 No.g) Suction Scrubber -1 No.h) V-Belts - 1 No.i) GI & MS Fittings - 1 No.j) Brass Fittings - 1 No.k) Exhaust Silencer - 1 No.i) Base frame for motor and vaccum pump - 1 setm) Pilot line with fittings - 1 set, Vaccum Room & Air Compressor Room Inside |
| 130 | Supply, installation, testing and commissioning of Compressed Air System of Reciprocating Oil Free Air Compressor belt driven type air compressor with following provisions.As per IS 12827 / 1987 & ISO 7396 / 1987 Specification Compressor package consists of following: a) 10 HP Air Compressor - 2 Nos.b) Electric Motor 10 HP-1 No.c) Dol Starter - L&T-10 HP - 1 No.d) Base Frame Kit (for Motor and Compressor) - 1set e) Pressure Swith - 1 No.f) Pressure Gauge - 1 No. g) NRV and Pilot Fittings - 1 No. h) Delivery Tube - 1 Noi) Foundation Bolts & Anchor Fasteners - 1 Lot j) Belt Guard - 1 No.k) Air Drier 50 to 60 cfm. capacity - 1 No.Drain Ball Valve - 1 No., Air Outlet Ball valve - 1 No., Vacuum Room &Air Compressor Room Inside Accessories:Non-Return Valves, Air Pressure Switch, Pressure Gauge, Isolation Valves, Air Filters etc., Inter connecting piping: Mild Steel Pipe of 2\" with fittings. |
| 131 | Supply and fixingof Fire fighting applicationoblique type stainless steel Hydrant Valve of size 63mm dia with oblique type instantaneous coupling with rotating wheel to open and close the valve including MS flange of table “E”, bolts & nuts with washer as per IS 5290 at ring main around the building and wet riser inside the building including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 132 | Supply of Fire Fighting Application MS Hose Box to keep two number of hoses and 1 No. of branch pipe with nozzle having proper glass window type double door with universe open key, painted inside white and outside Post Office Red.Near every hydrant point including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 133 | Supply, and fixing in positionof Fire Fighting Application Hose of 63mm dia of 15 metres length binded by copper wire with 63mm dia stainless steel male and female instantaneous fire fighting special coupling as per IS 901 asdirected by the Departmental Officers.Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the DepartmentalOfficers. Make: OMEX / KARTAR/ LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 134 | Supply, and fixing inpositionof Fire Fighting Application 63mm dia stainless steel short length Branch Pipe with hexagonal type spray nozzle of 15mm (or) 20mm jet bore. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 135 | Supply, installation of Fire Fighting Application 180 degree swinging type, hose reel drum with 20mm dia braidedthermoplastic hose of 30 metres long, so as to extend to necessary distance by self rolling spindle wheel including necessary 20mm dia ball valve and open and close spray nozzle, warm clip, etc., as per the standard pattern of any reputed make at every floor nearer to hydrant valve, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary., etc., completeas per standard specification and as directed by the DepartmentalOfficers.Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 136 | Supply and fixing nominal bore quartized bulb type sprinkler bulb 68 Deg C fast response pendent type including GI collar for each sprinkler bulb, mounted in MS pipe line using suitable size MS threaded coupling, thread, shellac etc., as per standard methods and including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 137 | Supply, Installing, testing and commissioning of Stainless Steel Corrugated Flexible Braided Pipe (Hose) for dropping sprinklers below false ceiling. Pipe shall be 16 bar pressure rating and 1500mm long, 25mm dia with union / reducer, collar, clamps, etc. It shall have UL listed and FM approved. Braided- 1.00m Length |
| 138 | Supplying and installing of approved type Rosette Plates (Recessed Type in Two Pieces) for sprinklers below false ceiling area. The Rosette shall be fabricated by MS plate of 2mm thick and the finish shall be powder coated and colour, as directed by the Departmental Officers. |
| 139 | Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe as per IS 1239 to withstand a developing pressure of 10 kg. / sq.cm including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers & joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidentalcharges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: JINDAL / EQUIVALENT. |
| 140 | 150 mm dia |
| 141 | 100 mm dia |
| 142 | 80 mm dia |
| 143 | 65mm dia |
| 144 | 50mm dia |
| 145 | 40mm dia |
| 146 | 25mm dia |
| 147 | Supply, erection, testing and commissioning of 150 mm dia of Heavy Duty Foot Valve including all accesories, such as, MS flange of table ‘E’, gaskets, bolts & nuts, etc., installed at end of 150 / 200mm dia suction pipe line at sump including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete and as per standard specification and as directed by the DepartmentalOfficers. Make: NORMEX / KARTAR / EQUIVALENT. |
| 148 | Supply, erection, testing and commissioning of 100 mm dia of Heavy Duty Foot Valve including all accesories, such as, MS flange of table ‘E’, gaskets, bolts & nuts, etc., installed at end of 150 / 200mm dia suction pipe line at sump including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete and as per standard specification and as directed by the DepartmentalOfficers. Make: NORMEX / KARTAR / EQUIVALENT. |
| 149 | Supply, erection, testing and commissioning of Cast iron bodyButterfly Valveof followingsizes at required places to control the flow of water including necessary MS flange of table ‘E’, gaskets, bolts & nutsincluding conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: ZOLOTO/ KARTAR / EQUIVALENT. |
| 150 | 150 mm dia |
| 151 | 100 mm dia |
| 152 | 65 mm dia |
| 153 | Supply, erection, testing and commissioning of Cast iron body and Gun metal or stainless steel internal Non-return valve of followingsizes to control one way flow of water. To be installedpump room at delivery line and near overhead tank at terrace level near to jockey pump and motor including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc. as per IS 5312 and as directed by the department officers.(MAKE:KARTHAR/ZOLOTO) |
| 154 | 150 mm dia |
| 155 | 100 mm dia |
| 156 | Supply, erection, testing and commissioning of Gun Metal Non-Return Valve of size 50mm dia including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc., installed at pump house delivery line for the purpose of priming to suction line so that to control one way including conveying, fixing and incidental charges etc., complete as per standardspecification and as directed by the Departmental Officers.Make: LEADER / EQUIVALENT. |
| 157 | Supply, erection, testing and commissioning of cast iron body and bronze internal non-rising spindle sluice valve of sizes at required places to control the flow of water including necessary MS flange of table ‘E’, gaskets, bolts & nuts including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: NORMEX / KARTAR / EQUIVALENT. |
| 158 | 150 mm dia |
| 159 | 100 mm dia |
| 160 | Supply and laying of following sizes of Armoured Aluminium / copper Cables for electrical motor, control panel, pressure switch, jockey motor etc..The rate inclusive of all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.Make: POLYCAB/ PARACON / FINOLEX / EQUIVALENT. |
| 161 | 4 core 10 sq.mm. armoured Aluminium / Copper cable |
| 162 | Earthing arrangements with GI Earth Plate includingcharcoaland salt with necessary excavation in all soils and to full depth as may be required and masonry work, re-filling the sides of foundation with excavated earth as per the standard specification and as directed by the Departmental Officers. |
| 163 | Supply, erection, testing and commissioning ofPressure Gauge with 0 to 14 kg. range of reputed make with necessary valve, milling thread MS coupling fixed at delivery pipe line in pump house to read the developing pressure including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the DepartmentalOfficers.Make: H-GURU / ISI MAKE / EQUIVALENT. |
| 164 | Supply, erection, testing and commissioning of suitable Pressure Switch of reputed make line Indfoss or Donfoss including necessary valves, couplings, etc., connected with electrical main control panel and setup at proper differential so as to auto start and auto stop the electrical motor, jockey motor including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., completed as per standard specification and as directed by the Departmental Officers. Make: DONFOSS / INDFOSS / ISI MAKE / EQUIVALENT. |
| 165 | Supply, erection, testing and commissioning of 180 LPM, 70 metres Head Pressurization Pump with 10HP electrical motor of Kirloskar make with suitable base frame includingnecessary vibration bad mounting etc., including conveying, fixing and incidental charges, etc., complete as per standard specification and as directed by the Departmental Officers.(Make: KIRLOSKAR / EQUIVALENT). |
| 166 | Supply, erection, testing and commissioning of Fire Fighting 4 Way Fire Brigade Inlet with necessary gun metal 63mm dia non return spring shutter arrangements, so that to control one way flow at the time of emergency water supply by fire and rescue service fire engine entry including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.(Make: KIARTAR / OMEX /EQUIVALENT). |
| 167 | Wrapping and coating anti-corrosive treatment for the following under ground MS pipe having one coat of anti-corrosive metal primer, one layer of asphalt tar tape wound over the MS Pipe as per standard methods as per standard specifications and as directed by the Departmental Officers.(150mm dia) |
| 168 | Supply, erection, testing and commissioning of Air Release Valve of 20mm dia, so as to release airlock in 100mm dia MS pipe at top most wet riser, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.Make: KARTAR / EQUIVALENT. |
| 169 | Providing, fixing pipe supports from columns / wall or suspenders from roof slab to suit various dia of pipes made out of GI / MS adjustable rods threaded for a sufficient length to adjust the height of support along with clamping arrangement for holding pipes of anchor fastening, arrangement design of hanger and should confirm with specification.(100 mm dia) |
| 170 | Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT |
| 171 | Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT |
| 172 | Supply, installation, testing and commissioning of Micro Processor based conventional 8 Zone Fire Alarm Control Panel having the rating of 24 volt DC power supply, consisting 230 / 24 volt SMPS unit, 2 Nos. of 12 volt 7 AH standby batteries, suitably mounted on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers. |
| 173 | Supply, installation, testing and commissioning of Conventional Smoke Detector suitably mounted on ceiling with MS juction box / false ceiling using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers. (Make: Apollo / Ravel / Equivalent) |
| 174 | Supply, installation, testing and commissioning of Manual Call Point (MCP) providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers.(Make: Ravel / Equivalent) |
| 175 | Supply,installation, testing and commissioning of Electronic Hooter / Sounder providing on wall usingfixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers (Make: Ravel / Equivalent) |
| 176 | Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall usingfixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers.MAKE: KEI/POLYCAB |
| 177 | Supply & installation of in position the sign board of \"Exit\" with arrow to be placed at walking pathways by fixing on walls to direct occupants to outside the building in an emergency. The exit sign board will be auto glow photoluminiscent type which will glow at dark.(single side indication ) |
| 178 | Supply &installation of fire escape route plan laminated board auto glow print to be placed at each floor by fixing on walls to direct occupants to outside the building in an emergency. The fire escape route plan will be auto glow photoluminiscent type which will glow at dark(single side indication) |
| 179 | Supply and kept in position of 9 litres capacity Fire Buckets of 4 Nos. with Bucket Stand as per standard specifications and as directed by the Departmental Officers. |
| 180 | Providing & Fixing of Installation Control Valve with turbine type automatic Alarm Gong to be connected with control valve, drain & test valve and all other necessary components as per manufacturer\"s specifications complete as required.(Control Valvewith turbine type automatic Alarm Gong (for Sprinklers system).MAKE: HD |
| 181 | Supplying, laying and jointing UPVC pipes of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The UPVC pipes shall be got approved by Executive Engineer before use on works. |
| 182 | 20 mm dia UPVC. Pipe |
| 183 | 25 mm dia UPVC. Pipe |
| 184 | Supplying and fixing the followingUPVC specials of heavy type of approved quality and good variety of various sizes excluding fixing charges, but including cutting and threading of pipes painting tow coats with good variety and approved quality synthetic eamel paint over one coat of priming coat for the GI specials in case of pipeline above ground level and one coat of tar in case of pipe line below ground level for both internal and external water supply arrangements as directed by the departmental officers etc., complete complying with standard specification. GI specials should be got approved by the departmental officers before use on work. |
| 185 | 20 mm dia Elbow |
| 186 | 25 mm dia Elbow |
| 187 | 20 mm dia Tee |
| 188 | 25 mm dia Tee |
| 189 | 25 mm dia union |
| 190 | 20 x 15 mm dia Reducer |
| 191 | 25 x 20 mm dia Reducer |
| 192 | 20 x 15 mm dia Reducer Elbow |
| 193 | 20 x 15mm dia Reducer Tee |
| 194 | Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS makeof the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements).The valves to be used on work shall be got approved by the Executive Engineer before use on work. |
| 195 | 20 mm dia Gun Metal Gate Valve |
| 196 | 25 mm dia Gun Metal Gate Valve |
| 197 | 32 mm dia Gun Metal Gate Valve |
| 198 | 40 mm dia Gun Metal Gate Valve |
| 199 | 50 mm dia Gun Metal Gate Valve |
| 200 | Supplying and fixing in position of SS Heavy Duty Long Body Tap 15mm (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works) |
| 201 | Supplying and fixing in position of SS Elbow Action Tap of size 15mm of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works) |
| 202 | Supplying and fixing in position best quality and approved make Indian made white glazed earthernware wash hand basin of size 550 x 400mm (without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia \"B\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before useon works) |
| 203 | Supplying and fixing of SS Sink of size 600 x 600 x 200 mm, including Labour etc., complete complying with standard specifications and as directed by the departmental officers. |
| 204 | Supplying and fixing in position CP shower rose with CP stop cock arrangement of size 15mm dia inlet and 100mm outlet to the pipe line with necessary cutting, threading and jointing using shellac etc., complete complying with standard specification and as directed by the departmental officers (The CP shower rose should be got approved by the Executive Engineer before use on works). |
| 205 | Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks) |
| 206 | Supplying and fixing approved best qualityStainless steel 304 grade towel rail 600mm long and 20mm dia pipe.The ends of the pipe is to be bended with required depth and the same is fixled in the wall firmly and the ends are coveredwith stainless steel cupetc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). |
| 207 | Supplying and fixing best approved best quality Procelain CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications.(The soap tray should be got approved by Executive Engineer before use on works). |
| 208 | Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works.(Above Ground Level) (External Water supply) |
| 209 | 32 mm dia UPVC. Pipe |
| 210 | 40 mm dia UPVC. Pipe |
| 211 | 50 mm dia UPVC. Pipe |
| 212 | Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works.(Below Ground Level) (External Water supply) |
| 213 | 50 mm dia UPVC. Pipe |
| 214 | Supplying and fixing the followingUPVC specials of heavy type of approved quality and good variety of various sizes excluding fixing charges, but including cutting and threading of pipes painting tow coats with good variety and approved quality synthetic eamel paint over one coat of priming coat for the GI specials in case of pipeline above ground level and one coat of tar in case of pipe line below ground level for both internal and external water supply arrangements as directed by the departmental officers etc., complete complying with standard specification. GI specials should be got approved by the departmental officers before use on work. |
| 215 | 32 mm dia Elbow |
| 216 | 40 mm dia Elbow |
| 217 | 50 mm dia Elbow |
| 218 | 32 mm dia Tee |
| 219 | 40 mm dia Tee |
| 220 | 50 mm dia Tee |
| 221 | 32 mm dia union |
| 222 | 40 mm dia union |
| 223 | 50 mm dia union |
| 224 | 32 x 25 mm dia Reducer |
| 225 | 40 x 32 mm dia Reducer |
| 226 | 50 x 40 mm dia Reducer |
| 227 | 32 x 25 mm dia Reducer Elbow |
| 228 | 40 x 32 mm dia Reducer Elbow |
| 229 | 50 x 40 mm dia Reducer Elbow |
| 230 | 32 mm dia Hex Nipple |
| 231 | 40 mm dia Hex Nipple |
| 232 | 50 mm dia Hex Nipple |
| 233 | 32 mm dia Coupler |
| 234 | 40 mm dia Coupler |
| 235 | 50 mm dia Coupler |
| 236 | Supplying, fixing of cylindrical vertical notational polythene water storage tank of 1000 litres capacity confirming to I S. 12701 / 96. the tank is meant for outer (or) indoor, use complete withremovable hinged top locking arrangements and to make provision to fix with simply pipe lines necessary manhole with cover and including all PVC specials, plugs, screws, nails to fix the tanketc., and the tank should be fixed firmly as directed.The rate shall inclusive of all materials labour, conveyance, hoistings and fixing charges etc., (The water tank should be got approved by the Executive Engineer before use on works by the deptartmental Officers. |
| 237 | Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm colour glazed earthern ware of approved quality and brand with \"P\" or \"S\" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two M-sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.(The water closet should be got approved by the Executive Engineer before use on works). |
| 238 | Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm \"P\" or \"S\" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank fixed on to wall with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications.(The EWC and flushing tank with all accessories should be got approved by the Executive Enginer before use on works) |
| 239 | Supplying and fixing in position CP Two Way Bib Cock with Health Faucet etc., complete complying with standard specification. |
| 240 | Supplying and fixing of Fine Polished Granite Slab 1200 x 600 of 18 / 20mm thick in all floors for urinal partition including for labour charges for fixing and polishing etc., |
| 241 | Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise andsimilar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. |
| 242 | Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works) |
| 243 | Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level. |
| 244 | 75mm dia PVC Soil Waste Pipe |
| 245 | 110mm dia PVC Soil Waste Pipe |
| 246 | 160mm dia PVC Soil Waste Pipe |
| 247 | Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works). |
| 248 | 75 mm dia PVC Elbow |
| 249 | 110 mm dia PVC Elbow |
| 250 | 160 mm dia PVC Elbow |
| 251 | 75 mm dia PVC Elbow with Door |
| 252 | 110 mm dia PVC Elbow with Door |
| 253 | 160 mm dia PVC Elbow with Door |
| 254 | 75 mm dia PVC Tee |
| 255 | 110 mm dia PVC Tee |
| 256 | 160 mm dia PVC Tee |
| 257 | 75 mm dia PVC Double \"Y\" with door |
| 258 | 110 mm dia PVC Double \"Y\" with door |
| 259 | 160 mm dia PVC Double \"Y\" with door |
| 260 | Supplying and fixing in position PVC cowls of following dia of best approved quality conforming to BIS, etc., complete complying with standard specifications.(The PVC cowl should be got approved by the Executive Engineer before use on works). |
| 261 | 75 mm dia PVC Vent Cowls |
| 262 | 110 mm dia PVC Vent Cowls |
| 263 | 160 mm dia PVC Vent Cowls |
| 264 | Construction of Inspection chamber or manholeof the following size including necessary earth work excavation in all soils to full depth as maybe directed with sand filling at bottom of the chamber for 10cm thick, concreting CC 1:5:10 using 40 mm gauge HBGS jelly 10 cm thick and side walls 9\" thick brick work in cement mortar 1:5 using second class Ground Moulded chamber burnt bricks of size 9\" x 43/8\" x 23/4\" filling the size of foundation with excavated earth, plastering with cm 1:3, 20mm thick for inside and bottom and making necessary benching with brick jelly cement concrete to the required slope and fifnishing neatly etc., complete |
| 265 | CLEAR SIZE 0.60 X 0.60. |
| 266 | CLEAR SIZE 0.90 X 0.90. |
| 267 | Supply and fixing of Manhole Cover SFRC as per following size including labour and transportation charges etc., complete as directed by the departmental officers. |
| 268 | 600 x 600mm |
| 269 | 900 x 900mm |
| 270 | Supplying and fixing of Acryllic form name plate 3mm thick with Vinyl printing including embossing the letters of all fonts and sizes etc., complete as per the direction of the departmental officers. |
| 271 | Supplying and Fixing ,Manufacturing of Waiting Steel Chairs are perfect indoor and semi-outdoor have Three Perforlated Seats of size 175 x68 x77 cm etc., complete as per the direction of the departmental officers. |
| 272 | Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc.By first taking a pilot bore of 140mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation methord using rotary rigs fuel, labour for drilling bentonite and water required for drilling at site (Site will be shown by the TWAD Board Officers) including construction of mud pit. |
| 273 | Upto 60 m Depth ending below ground Level |
| 274 | From 61 m to 90 m Depth ending below ground Level |
| 275 | From 91 m to 120 m Depth ending below ground Level |
| 276 | From 120 m to 150 m Depth ending below ground Level |
| 277 | From 151 m to 180 m Depth ending below ground Level |
| 278 | From 181 m to 210 m Depth ending below ground Level |
| 279 | Supplying of best approved quality ofPVCcasing pipe of 6\" dia (Special Blue Slotted Pipes for Bore Wells) for borewell with socket end to suit borewell of required depth -6kg/cm2best approved quality with ISI mark with necessary PVC coupling etc., |
| 280 | Supplying and fixing the P.V.C. end cap of160 mm dia at the end of P.V.C. casing pipe etc., complete complying with standard specification.The bore cap should be got approved by the Executive Engineer before use on works. |
| 281 | Supplying of best and approved quality of Nylon rope of the following size including laying in the bore well and tying with copper wire it etc complete complying with standard specification. |
| 282 | UPVC Pipe (Un-Plasticized Polyvinyl Chloride)UPVC used for residential and home applications, water pressure in residential areas do not normally exceed the maximum tolerance. (Schedule-40)UPVC pipe 40mm dia |
| 283 | Supplying and fixing 5 HP / 3 Phase, 9 Stage sub mergible pump of approved make and quality with ISI mark with necessary accssories and fixed with delivery pipe errected in the borewell with necessary clamp etc., with following additional accssories.1 No of 3 Phase Star Delta Starter of 63 AMPS of approved quality and make with ISI mark.1 No of 3 Phase 63 AMPS Main Switch of approved quality and make with ISI mark.1 No of priventor of approved quality and make with ISI mark.1 No of pannel board of required size with indicator fuse unit voltmeter with necessary provision toaccomodate the starter and mini starter etc.1 No of capacitor with board as per standards of TNEB. |
| 284 | Supplying and erection of 3 Phase Panel Board including labour charges including transportation charges, erection charges etc., complete complying with standard specification and as directed by the departmental officers. |
| 285 | Supplying and erection of submersible wire following size cable PVC insulated and sheathed 3core flat type copper cable with ISI make including erection inside the bore well and open run of clamping etc., completer complying with standard specification., as directed by the departmental offcers., |
| 286 | Supplying and fixing of 160mm PVC Pipe etc,complete complying with standard specification. (6kg.per.sq.cm) |
| 287 | Designing ,supplying, erecting and commissioning of Sewage Treatment plant 50 KLD design capacity with the following accessories |
| 288 | Supply, erection and commissioning of bar screen, MSEP, 10 mm spacing for capacity 50 KLD to remove solid particles before entering to equalization tank |
| 289 | Supply, erection and commissioning Raw sewage Transfer Pump of capacity 2.5 m3/hr, 15 m head, horizontal centrifugal pump, CI, inclusive of suction and discharge valves, fittings, pump base plate, motor to transfer raw sewage from equalization tank to aeration tank |
| 290 | Supply, erection and commissioning FBBR Media in aeration tank to increase the surface 400 m2/m3 for bacterial growth of required quantity inclusive of mesh to stop media to escape from aeration tank |
| 291 | Supply, erection and commissioning tube settler media in secondary settling tank to remove settling particles from water 1 lot |
| 292 | Supply, erection and commissioning of Coarse Pore Diffuser for equalization tank to equalize the water before entering to aeration tank, UPVC MOC |
| 293 | Supply, erection and commissioning of Fine Pore Diffuser for aeration tank to develop micro organisms, 90 mm dia x 1000 mm long,EPDM MOC , |
| 294 | Supply, erection and commissioning of air blower for EQT and aeration tank of capacity 120 m3/hr, 0.4 m head, MOC CI, twin loobe blower inclusive of valves, pressure gauge, suction filter, base plate 1 set |
| 295 | Supply, erection and commissioning Filter feed Pump of capacity 2.5 m3/hr, 30 m head, horizontal centrifugal pump, CI, inclusive of suction and discharge valves, fittings, pump base plate, motor to transfer clarified water from clarified water tank to PSF and ACF 1 set |
| 296 | Supply, erection and commissioning of pressure sand filter of size 500 mm dia x 1500 mm HOS, MSEP/FRP, inclusive of frontal piping, valves, pressure gauge, sand and pebbels media 1 set |
| 297 | Supply, erection and commissioning of activated carbon filter of size 500 mm dia x 1500 mm HOS, MSEP/FRP, inclusive of frontal piping, valves, pressure gauge, sand and pebbels, carbon media 1 set |
| 298 | Supply, erection and commissioning sludge transfer Pump of capacity 1.5 m3/hr, 10 m head, horizontal centrifugal pump, CI, inclusive of suction and discharge valves, fittings, pump base plate, motor to transfer sludge from settling tank to sludge holding tank 1 set |
| 299 | Supply, erection and commissioning of Hypo Chloride Dosing Sys. Of capacity 0 to 6 LPH, 4 bar pressure, meteting pump, 100 liters HDPE tank, inclusive of pipe, valves and fittings 1 set |
| 300 | Supply, erection and commissioning of interconnecting piping for water and air, UPVC pipe line for water, MS pipe line for non submerged air line inclusive of supports and fittings 1 lot |
| 301 | Supply, erection and commissioning of instrument for STP like pressure gauge, level switch, electro magnetic flow meter as required for proper monitoration of plant working 1 lot |
| 302 | Supply, erection and commissioning of electrical panel of non draw out type, non compartmental type with required feeder, OLR, stop/start switch, Trip indicator, interconnecting cabling cabling from individual drive to panel along with cable tray and its supports, cable lugs, gland, earthing, cable tie 1set |
| 303 | Supply, erection and commissioning sewage submersible pump 3 m3/hr @ 10 m head, CI, inclusive of suction and discharge valves, fittings, with dry run protection, pump base plate, motor to transfer raw sewage from collection well to collection tank 1 set |
| 304 | Supply, erection and commissioning sewage treated water pump, centrifugal, 3 m3/hr @ 20 m head CI, inclusive of suction and discharge valves, fittings, pump base plate, motor to transfer from sewage treated water tank to treated water transfer 1 set |
| 305 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) ( 4 points / Coil) Higher End |
| 306 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End ) |
| 307 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End |
| 308 | Supply and fixing of WT bulk head fitting with guardsuitablewith 7W / 9W LED bulb |
| 309 | Supply and fixing of Aesthetically designed ultra modern 24WRound surface Mounting luminaire with high brightness LED fittingon wall or ceiling, with PVC unsheathed leads from terminals to the fitting. (Havels / Equivalent ) |
| 310 | Supply and fixing of Aesthetically designed ultra modern 24W 1 x1 LED surface Mounting luminaire with high brightness LED fittingonceiling, with PVC unsheathed leads from terminals to the fitting. (Havels/ Equivalent ) |
| 311 | Supply and fixing of Aesthetically designed ultra modern 36W 2\" x 2\" surface Mounting luminaire with high brightness LED fittingon wall or ceiling, with PVC unsheathed leads from terminals to the fitting. (Havels/ Equivalent ) |
| 312 | Supply and fixing of single box type 4\" 20 W LEDfitting complete with TW round blocks on wall or ceiling with20 W LED tube light with Single side connectionwith PVC unsheathed Copper leads from terminals to the fitting. ( Havells /Crompton/equivalent) |
| 313 | Supply and fixing of 2 x 4 feet 18W Twin crystal glass LED tube light with TW round blocks on Wall or ceiling with PVC unsheathed copper leads from terminals to the fitting with LED tube |
| 314 | supply and fixing of 1200mm (48\") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 300 mm down rod on the existing fan clamp |
| 315 | Supply and fixing of 200mm sweep (light duty) Modular High Speed exhaust fan complete with necessary wall opening and making good of the wall( Higher End) |
| 316 | Supply and fixing of 60W LED Street light fitting complete with 32mm dia GI pipe (class \"B\") wth 1 no 32mm dia GI bend complete on the eisting post/ wall with SMC box with 15A fuse unit and 5A flush type switch with PVC unsheathed copper leads from fuse carrier to the fitting, MS clamps and aluminium painting with including necessary labour (Havells/ Philips) |
| 317 | Supply and fixing of 65mm (2 1/2\") GI pipe (Class \"B\") of 8 metre length with 300mm X 300mm X 6mm MS base plate duly welded at the bottom withconcreting the construction of masonry pedestal with suitable MS box to house the 10A SP MCB two 4way connector on suitable hylem sheet with SMC box and supply and fixing of 1X70W led type street light fitting (Make: Philips / Havells / Equivalent) with necessary cowl arrangements on the above post with PVC unsheathed leads with coil earthing and painting of suitable colour |
| 318 | Supply and fixing of 50WLED flood light fiting on the suitable existing post or wall .(Havells/ Philips) |
| 319 | Supply and fixing of 150WLED High bay light fiting on the suitable existing post or wall .(Havells/ Philips) |
| 320 | Supply and fixing of 3 nos.6A two module socket , 1 no. 6/16A two module socket , 3 nos. 6A one module switch, 1 no.16A one module switch on suitable module surface mounting Box ( Plastic ) with module cover plate (plastic) on wall with connections. Higher End |
| 321 | Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End |
| 322 | Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug) |
| 323 | Supply and run of 2 of 1.5sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in rigid pipe concealed in wall and ceiling with continuous earth wire connection of 1.5sq.mm copper wire and making good of the concealed portion with suitable colour (For UPS ) |
| 324 | Supply and run of 2 of 4sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4sq.mm copper wire and making good of the concealed portion with suitable colour.(For Plug set ) |
| 325 | Supply and run of 2 of 6sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with contiinuous earth wire connection of 6sq.mm copper wire and making good of the concealed portion with suitable colour. (For 12 Way LDB) |
| 326 | Supply and Run of 2 of 10 sq.mm.PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigidpipe concealed inwall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position.(UPS Outgoing) |
| 327 | Supply and run of 4 of 6sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 6sq.mm copper wire and making good of the concealed portion with suitable colour.(For 32A Encloser 8.5 TR Laminnor -3 ) |
| 328 | Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position. (For 4 and 6 Way 7 seg DB and 4way VDB 63A-26 Nos and UPS-4 Nos, lift-1No, 11TR-1 No) |
| 329 | Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End |
| 330 | Supply and fixing of 7 segment4 way TPN MCB sheet steel distribution board (Higher end) with metal / acrylic doorcover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no. 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 4 ways in each segment) and seperate provision for MCB / Isolators ( totally 12 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. withthe following in flush with wall with earth connection only. (For Ac Plug and 16A Plug) |
| 331 | Supply and fixing of 7 segment6 way TPN MCB sheet steel distribution board (Higher end) with metal / acrylic doorcover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no. 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 6 ways in each segment) and seperate provision for MCB / Isolators ( totally 18 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. withthe following in flush with wall with earth connection only. (For Plug set) |
| 332 | Supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCBswitch as incoming and 12 nos. 6A to 32A SP MCB as outgoing in flush with wallwith earth connection only.HigherEnd( For STP & Morturay ) |
| 333 | Supply and fixing of 6 way Vertical Triple pole and neutral MCCB sheet steel enclosure distribution board ( with MCCB Incomer ) with double door (metal door) with 1 no. 160 A 4 P MCCB switch as incoming and 4 nos. 63A 3P MCB , 6 nos. 6A to 32A SP MCB as outgoing with suitable cable end box on wall with earth connection only. Higher End (for 4 way VDB 100A) |
| 334 | Supply and fixing of 32A FP MCB in flush with sheet enclosure in wall with earth connection(For OT 8.5 TR Laminar AC-3 Nos x 2 Auto Clave-1 Street light -1 ) |
| 335 | Supply and fixing of 63A FP MCB in flush with sheet enclosure in wall with earth connection ( 11TR-1 No x 2 UPS -4 Nos x2) |
| 336 | Supply and Laying of 4x16sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. |
| 337 | Supply and clamping of 4 x 16 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps |
| 338 | Supply and fixing of brass cable gland for 3-1/2 x 120 sq.mm. PVC armoured LTUG cable with earth connection |
| 339 | Supply and providing cable end termination of 31/2 x 120sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete |
| 340 | Supply and clamping of3 1/2 x 120 sqmm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps.(From 200A NS Panel to 6 way MCCB DB 160A) |
| 341 | Supply and frxing of brass cable gland for 3 1/2 x 150 sqmm PVC armoured LTUG cable with earth connection |
| 342 | Supply and providing cable end termination of 3 1/2 x 150 sqmmPVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete |
| 343 | Supply and clamping of 3 1/2 x 150 sqmmPVC LTUG armoured LTUG cable on post or on wall with MS Clamps.( From 250A Panel to 200A Panel board FloorPanel) |
| 344 | Supply and fixing of brass cable gland for 3 1/2 x 185 sqmm PVC armoured LTUG cable with earth connection |
| 345 | Supply and providing cable end termination of 3 1/2 x 185 sqmmPVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete |
| 346 | Supply and laying of 2 runs of 31/2 x 185 sqmm size of PVC armoured LTUG cable in a cable trench . ( From HT Room to 250A Panel E &NS) |
| 347 | Supply and clamping of 2 runs of 31/2 x 185 sqmm of PVC armoured LTUG cable onPost or wall .( From Genset to AMF Panel) |
| 348 | Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection |
| 349 | Supply and run of 1\" x 1/8\" (25mmx3mm) tinned copper flat with necessary clamps/supports onall / floor/ ground for earth connection. |
| 350 | Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earthconnection |
| 351 | Earthing as per the ISI specification with an earth electrode of 2.10 metre Class\"B\" GI pipe of dia not less than 40mm with copper earth plate of size 125mm x50mm x6mm with necessary funneling arrangement swith necessary masonry work and with 38mm RCC cover slab for the brick masonry |
| 352 | Supply and erection of 250 Amps Capacity dust and vermin proof floor mounting cubical panel board fabricated out of 16 SWG MS sheet for outer body, stiffness and doors and with supply and fixing of following interior switches with centre bus bar chamber and vertical no of switches one over the other on both sides of bus bar chamber with cable adopter chamber ofthe extreme wnd of one side with two coats of quality paint over one coat of zinc oxide primer superscription of incoming and outgoing feeding cable details, capacity of switches etc., with white paint and 2 nos metallic danger board affixed complete on base channel supports to satisfy the latest CEIG rules withthe following switches confirming to IS specifications.1] 250A FP switch disconnector fuse interior only with HRC fuses double break - 1No [L & T / Siemens]2]200 A TPN switch disconnector fuse interior only with HRC fuses double break-4Nos [L & T / Siemens].A separate chamber on the top of one side should be fixed with 0-500V voltmeter, 0.500A Ammeter, C.T, Selector switches with one set LED pilot lamp with HRC fuses.The bus bar chamber should have 3 Nos of 1 \" x 1/4\" tinned copper flat for 3 phases andneutral and 1 \" x 1/8\" for body earth busmust be run all round the panel to provide earth connection to the cubicle switches cable glandsetc., the bus bars should be supported on synthetic enamel compound at equal internal as per IS specification. The incoming and outgoing switches should be connected to the bus with the following copper flats.(Main Panel Essencial and Non Essencial Panel) |
| 353 | Supply and erection of 200 Amps Capacity dust and vermin proof floor mounting cubical panel board fabricated out of 16 SWG MS sheet for outer body, stiffness and doors and with supply and fixing of following interior switches with centre bus bar chamber and vertical no of switches one over the other on both sides of bus bar chamber with cable adopter chamber ofthe extreme wnd of one side with two coats of quality paint over one coat of zinc oxide primer superscription of incoming and outgoing feeding cable details, capacity of switches etc., with white paint and 2 nos metallic danger board affixed complete on base channel supports to satisfy the latest CEIG rules withthe following switches confirming to IS specifications.1] 200A FP switch disconnector fuse interior only with HRC fuses double break - 1No [L & T / Siemens]2]160 A TPN switch disconnector fuse interior only with HRC fuses double break-1Nos [L & T / Siemens].3]100 A TPN switch disconnector fuse interior only with HRC fuses double break-4Nos [L & T / Siemens].4]63 A TPN switch disconnector fuse interior only with HRC fuses double break-1Nos [L & T / Siemens].A separate chamber on the top of one side should be fixed with 0-500V voltmeter, 0.500A Ammeter, C.T, Selector switches with one set LED pilot lamp with HRC fuses.The bus bar chamber should have 3 Nos of 1 \" x 1/4\" tinned copper flat for 3 phases andneutral and 1 \" x 1/4\" for body earth busmust be run all round the panel to provide earth connection to the cubicle switches cable glandsetc., the bus bars should be supported on synthetic enamel compound at equal internal as per IS specification. The incoming and outgoing switches should be connected to the bus with the following copper flats.(Each Floor 2 Nos for Essencial and Non Essencial - 6 Nos) |
| 354 | Design, Engineering, Fabrication,Renewal by Supply, Erection, Testing, Commissioning and Handing over of 1 No 26 Persons Bed cum Passenger Lift as per following technical specifications which includes all taxes and duties.Technical Specifications:Location: the Critical Care Block in Govt.Hospital at Vaniyambadi in Thirupathur District.1. No of lift: One No2. Type of lift: Mono Space (Gearless Machine)(with Machine Room )3. Capacity of lift: 26 Persons (1768 Kgs)4. Speed: 1.00mtr / sec5. Type of drive: Microprocessor based specific variable voltage variable frequency (V3F) drive with enhanced ride comfort and near zero leveling functions.6. No of floors: Ground+2 floors. 7. Total travel:9.9 Mts Servicing Ground +2 floor 3 stops, & 3 opening.8. Leveling accuracy: High level accuracy with smooth and jerk free stopping. 9.Construction ofCar: Special car made of stainless steel hairline finish panels complete with single tile false ceiling with direct CFL lighting, tubular handrail, 300mm sweep fan, stretcher impact guard at all three side to prevent the SS damages and for better aesthetics.10. Position of machine: Directly above the lift well.11. No of Entrance: 1 No (Front)12. Car size: 1600 mm wide x 2400 mm deep x 2200mm height.Clear opening: 1200mm X 2000mm height |
| 355 | 13. Lift well size : 2400 mm wide x 3200mm depth (existing) RCC construction with brick masonry .14. Lift pit depth :1800 mm15. Power supply: 415V, Three phase and 230 V 50 Hz single phase AC supply for light.16. Control: Micro computer based full- collective logic system with / without attendant mode. 17. Car Indicator: Digital 7 segment 1.1mm Height direction & position indicator with height intensity indication in Red color. 18. Landing Indicator:Digital 7 segment 1.1mm Height direction & position indicator with height intensity indication in Red color19. Emergency alarm bell: Battery operated alarm bell to be provided with automatic charging .20. Emergency light: Battery operated light to be provided with automatic chargingdevice.21. Fire man’s switch: To be provided at ground floor.22. Minor builders work: To be provided by lift contractor.23. Scaffoldings: To be provided by lift contractor.24. Steel for lift machinery: To be provided by lift contractor.25. Stainless steel sill angles and facia plates: To be provided by lift contractor.26. Servicing and maintenance: Free comprehensive servicing and maintenance should be provided by lift contractor during the guarantee period of one year. |
| 356 | 27. Automatic Rescue Device: To facilitate the landing of the nearest floor at the time of power failure. This shall consist of suitable type battery system with charger, inverter under voltage protection system etc. 28. Lift license: Preparation of drawing, payment of charges to CEIG and insurance policy and obtaining CEIG safety certificate as per lift act should be done by the lift contractor.29. Floor annunciate with music30.Special features a) Inverter based battery operated emergency light & alarm bell.b) Stainless steel signal fixtures.c) Aluminium checkered plate flooring.d) Call Registering Type Micro push button.e) Automatic rescue device.f) Full Collective Logic controlg) PCB control push buttonh) Separate fan switch in the cari) Constant voltage Transformer for control system.j) In built brake release leverk) Pit ladderl) Stretcher impact guard at all three sidem) Intercomn) Load weighing deviceo) Lift floor announcementp) Minor civil worksq) Scaffolding r) Obtaining Lift License |
| 357 | 31.Special features to be added in the Lifts for people with wide range of abilities should be as per annexure I enclosed.32. Over speed governor, phase failure and phase reversal relay, alarm bell, T guide brackets for car and counter weight. Rubber padding under winding unit. Motor of adequate capacity electromagnetic brake with compression springs, car safety gears, buffers, electro mechanical door locks. Emergency key, side supporting angles, motor over load protection devices, final limit switch, main suspension ropes, counter weights etc,. 33. Guarantee: Guarantee for the materials & workmanship of equipments complete should be offered by the lift firm for a period of not less than one year.34. Site testing in accordance with IS 14665 should be carried out at the time of handing over. (Make:Johnson/Kone/OTIS/Equivalent) |
| 358 | Supply , Testing Commissioning and Handingover of 1 No 160 KVA Diesel Generator set of 0.8 P.F. Three phase 415V/ 420 Volts, 50Hz, 1500 RPM Diesel Generator Set with acoustic enclosure conforming to CPCB IV+ Norms and BIS Specifications Approved capacity comprissing of Kirloskar Engine model 6R 1080TA developing 154 BHP water cooled clock wise rotating feed pump with 128KW/ 160 KVA operating capacity brushless alternator close coupled underneath fuel tank standard safeties LLOP with stop solenoid battery with lead Electric start and vibration fitting and accessories and AMF panel as detailed below including transporting & unloading charges.(A) Engine: Water cooled diesel engine suitable for Generator application with a shaft out put of 154BHP at 1500 RPM under NTP conditions. The Engine shall comprise the following standard fitting flexible coupling fly wheel, ai cleaner, fan blower, radiator, water pump, fuel filter, lubricating oil filter, etc.(B) 12/24 Volt Electronic starting Equipment:Complete with starter motor, dynamo, standard batteries with cable, flexible exhaust piping of 50cms length.(C) ENGINE INSTURMEN PANEL / MOUNTED:Starting push botton / starting key, lubricating oil, temperature gauge, lubricating oil pressure gauge,water temperature gauge, safety control for low lubricating oil, pressure, safety control for high water temperature, safety control for over speed, hour meter (mechnical ) and RPM indicator, battery charging ammeter. The engine should be capable of providing 10% over load for one hour for every 11 hours continuous at full load. |
| 359 | (D)ALTERNATOR:160 KVA/128KW Capacity of brushless alternator, AC 3 phase, 50Hz, 415/420V, 0.8 PF, 1500 RPM under NTP conditions, conforming to IS:13364 (Part-II)/ 1992 to be means of coupling.(E) AMF CONTROL PANEL:The AMF control panel (cubical) should be fabricated with vermin proof and dust proof best quality sheet steel and floor mounted with removable rear panels and hinged front doors with enamel painted and incorporating the following with suitable provision for connection incoming and outgoing leads having been made on the control panel.1. AC Ammeter and selector switch. 2 . Volmeter and selector switch. 3. 3Nos current transformer with suitable ratio 4. Frequency meter 5. KWH meter6. 1 No power factor meter 7. Battery charging set comprising of the following for charging the battery from mainsa. Transformer / Rectiferb. DC Ammeterc. DCVolt meterd. ON / OFF switche. Charging rate selector switchf. push button startg. push button stoph. push button reset8. 1 set Air break contactor with auxiliary netural contactor for main supply |
| 360 | 9. 1 set Low volage HRC fuse for the short circuit protection of the main supply10. 1 set Alternator contactor with auxiliary netural contactor. 11. 1 set Three pole bimetal release for over load protection of alternator12. 1 set low voltage HRC fuse for the short circuit protection of the alternator 13.1 set DC control relays incorporating engine start/ stop and failure to start / lockout 14. 1 set selecor switch auto/ manual15. 1 no Push button \"Start\"16. 1 no Push button \"Stop\" 17. 1 no Push button \"Reset\"18.1 No signal lamp for indicating load on mains19. 1 no signal lamp for indicating load on set. 20.1no signal lamp for indicating set fails to start. 21.1no signal lamp for indicating set running. 22.1No signal lamp for indicating battery 23. 1set Pilot lamps of 3 nos24. MCCB of 250A capacity with magnetic thermal overload release, instant start circuit trip and under voltage release switch.25.Rectangular copper bus bars (1No for each phase, neutral and earthing terminals) of adequate capacity duly colour coded with head shrinkable PVC sleeves. 26.1No mains voltage monitor 27.Hooter/Audio alarm for indicating set fails to start and for DG O/L.28.1set Timers29.Audio and Visual indicator arrangements for: a) Low lubricating oil pressure |
| 361 | b) High water temperaturec) Over speed 30.1No Earth fault relay31.Isolator to isolate the neutral Note:-1. The control panel should be complete with necessary fuses, cables, label, other accessories with neutral isolation arrangements.2. The engine should trip for the following: a) Low lubricating oil pressureb) High water temperature c) Over speed3.Supply and fitment of Auto Mains Failure Panel, 1 EB Service wih 200 Amps switch and contactors SUF Control relays, timers etc suitable for auto change over of DG & EB Service. F.FUEL TANKFuel tank of 200 litres capacity and with inlet and outlet connections, level indicator with scale etc. G.BASE FRAME:Base frame should be fabricated with MS channel frame of rigidly welded construction for mounting of generaor set. The engine and alternator should be coupled by suitably designed diaphragm type flexible coupling with guard and mounted on the base frame wih proper alignment.H) ACOUSTIC ENCLOSURE:The Acoustic enclosure,Self standing weather proof KG- CPCB Typed Acoustic canopy KG 250WS floor mounting type with modular construction with the provision to assemble and dismantle easilyanddesigned to suit all weather condtions. Erection of acoustic enclosure suitable for 160 KVA Diesel generator complete with all accessories as above and suitable supports etc.1. Supply of manuals for operation & maintenance of DG set with warranty card etc. |
| 362 | Erecion of Get set:-Providing suitable concrete foundation with cement concrete 1:2:4 with sand cushion around the foundation erection of 160 KVA Generator set over the exisiting foundation and erection of Generator set with proper alignment over the existing foundation to suit 160 KVA Generator set Foundation size L4200xW1600xH200mm. |
| 363 | Preparation of Electrical schematic diagram, site plans, physical layout 5 copies and payment of CEIG fees submission of completion report, rectification report, obtaining drawing approval, safety certification etc., complete including lamination copy fixed at HT sub station. |
| 364 | Supply and fixing of 10 KVA Automatic invertor with input Voltage 180V-260V and output voltage 200V -230V 50Hz with16 No 12V 150AH tubulur Battery and testing complete with connection.(Three Phase IN & Single Phase Out) (Make Exide/ Luminous/equ) |
| 365 | Supply and erection of 2.0 Ton capacity ( 3star Rated) Split type Airconditioner unit confirming to ISI 1301 (part-2) 1992 with amendment No.1 fitted with Hermetically sealed compressor operationon 230V 50Hz AC supply system with refrigerant gas R-22 suitable for high wallmounting evaporator and specification as under general requirement interconnection of pipes abd cable.(SR) (Make: Blue Star, Carrier, Voltas.) |
| 366 | Supply and erection of 5KVA capacity Automatic Voltage stabilizer suitable to operation on 230 volts, single phase,50Hz,AC supply system with tie delay relay and High/Low voltage cut off, input voltage range 170V to 270V AC single phase, wall mounting type stabilizer with necessary clamp. (SR)(V-Guard) |
| 367 | Supply and fixing of Copper pipe to connect Indoor and Outdoor units |
| 368 | Supply and fixing of MS stand for fixing outdoor unit. (SR) |
| 369 | AIR HANDLING UNIT (8.5 TR) Supply,installation, commissioning of 8.5 TR Double skin AHU suitable for operation theatre with aluminium inner skin and aluminium outer skin with minimum 50mm PUF insulation in between 3400CFM, 125mm of Static Pressure without Mixing box for fresh air and outlet drive arrangment, fan, S.S drain pan, suitable TEFC drive motor, 6R deep coil with face velocity not exceding 500FPM, fire proof canvas with 10&5 micron filters.(Ceiling MountedM-2674) |
| 370 | Supply, installation, Commissioning of 8.5 TR Air Cooled condensing unit with scroll compressor and microprocessor control panel with vibration mounting pads with nitrogen pre-charged. Connecting with the Indoor AHU Unit. |
| 371 | Supply and filling of R-407C Refrigerant gas. |
| 372 | Supply and fixing of hard drawn copper refrigerant piping of 5/8” dia interconnecting indoor and outdoor units with necessary fittings, supports etc., |
| 373 | Supply and fixing of hard drawn copper refrigerant piping of 7/8” dia interconnecting indoor and outdoor units with necessary fittings, supports etc., |
| 374 | Supply and fixing of flexible canvas connection between indoor unit and ducting and rubber pads. |
| 375 | Supply, Fabrication and erection of fabricated ducting 22 gaugesheet made up ofAluminium sheets of complete withMS angle supports angle flanges, anchor fastess,teesand bends where ever necessaryetc as required. |
| 376 | Supply and fixing of duct mouth dampers |
| 377 | Supply and providing thermal insulation of9 mm thick vidoflex with aluminum foil. |
| 378 | Supply and fixing of extruded aluminum powder coated supply and return air grilles/diffuserswith volume control damper. |
| 379 | Supply and fixing of suitable MS angle frame for mounting the outdoor unit |
| 380 | Supply and fixing of laminar air flow unit a. cabinet made from stainless steel 304b. dimension 2’x 2’x1’ - 4 Nos c. HEPA filters, size : 1220x610x 100mm -4 Nos size : 915x610x100mm -2Nos Type : box type Media Ultra clean glass fiber paper – imported Casing: M.S power coatedRetention: 0.3 MicronEfficiency : 99.97%Pressure drop: 25mm of WCCleanliness level : Class 100/1000 |
| 381 | Supplyand providing of power supply for indoor to outdoor unit motors for 10 Sqmm copper flexible single cable |
| 382 | Supplyand providing of control supply for indoor to outdoor unit Hp and Lp cut outs for 1.5Sq mm copper flexible cable |
| 383 | Supplyand providing of signal cable for indoor to outdoor unit sensor controls for 0.5Sq mm 4 core flexible signal cable |
| 384 | Supply 11 TR norminal capacity ceiling suspended ductable air conditioner with the following components. 11 TR capacity ceiling suspended Ductable Air conditioner high tech,low height,low noice level indoor unit with fin and tube type cooling coil,Detachable type drier provided in refrigerant cicuit to reduce moisture content multi stage type distributor for feeding equal quantities of the refrigerant mixture to all the section of the coil,with required valves,directly coupled blower to reduce troubles and wear & tear compared to belt drive blower.Thermostatic expansion valve lift and pull type aluminum framed durable,washable air filter.lntegrated electrical panel with complete microprocessor control with display for easy operation and maintenance of unit common operating conditions of 45 F suction temperature Auto reset type HP/LP safety cut to improve reliability of compressor. |
| 385 | Supply and fixing of hard drawn copper refrigerant piping of 1 1/8\" dia,interconnecting indoor and oudoor units with necessary fittings,supports etc. |
| 386 | Supply and Providing of insulation for copper refrigerant piping and water drain pipe line |
| 387 | Supply and providing acoustic for initial portion of ducting with 12mm thick fiber glass rigid board covered with tissue paper and aluminum perforated sheet. |
| 388 | Supply and fixing of water drain pipe line (1\" PVC pipe) |
| 389 | GST @ 18% |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy