Renovation of UPHC 02-- 1 Supplying profiles of requredsection made of Aluminium Alloy extrusions conforming to IS:732-1983 and IS:1285-1975; Annodized (with required film thickness and specified colour/natural) matt finished conforming to IS: 1868-1983 for fabrication of composite door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed/ certifiedmake and brand as per direction of Engineer-In- Charge . (Payment will be made on finished length of the work). 2 (A) In 10-12 Micron thickness Annodizing film. 3 (I) NaturalWhite. 4 (j) Fixed partitions. (Unsupported length of Vertical members upto 1.5 mtr. Height of both ends of vertical members restrainedbut panels more than0.9 Sq.m.). 5 (i) Top bottom & side member. 6 Supplying profiles of requredsection made of Aluminium Alloy extrusions conforming to IS:732-1983 and IS:1285-1975; Annodized (with required film thickness and specified colour/natural) matt finished conforming to IS: 1868-1983 for fabrication of composite door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed/ certifiedmake and brand as per direction of Engineer-In- Charge . (Payment will be made on finished length of the work). 7 (A) In 10-12 Micron thickness Annodizing film. 8 (I) NaturalWhite. 9 (j) Fixed partitions. (Unsupported length of Vertical members upto 1.5 mtr. Height of both ends of vertical members restrainedbut panels more than0.9 Sq.m.). 10 (ii) Intermidiate member. 11 Supplying profiles of requredsection made of Aluminium Alloy extrusions conforming to IS:732-1983 and IS:1285-1975; Annodized (with required film thickness and specified colour/natural) matt finished conforming to IS: 1868-1983 for fabrication of composite door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed/ certifiedmake and brand as per direction of Engineer-In- Charge . (Payment will be made on finished length of the work). 12 (A) In 10-12 Micron thickness Annodizing film. 13 (I) NaturalWhite. 14 (j) Fixed partitions. (Unsupported length of Vertical members upto 1.5 mtr. Height of both ends of vertical members restrainedbut panels more than0.9 Sq.m.). 15 (iii) Glazing clip. 16 Supplying profiles of requredsection made of Aluminium Alloy extrusions conforming to IS:732-1983 and IS:1285-1975; Annodized (with required film thickness and specified colour/natural) matt finished conforming to IS: 1868-1983 for fabrication of composite door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed/ certifiedmake and brand as per direction of Engineer-In- Charge . (Payment will be made on finished length of the work). 17 (A) In 10-12 Micron thickness Annodizing film. 18 (I) NaturalWhite. 19 (k) Movable door shutter. 20 (i) Door frame (Top & sides). 21 Supplying profiles of requredsection made of Aluminium Alloy extrusions conforming to IS:732-1983 and IS:1285-1975; Annodized (with required film thickness and specified colour/natural) matt finished conforming to IS: 1868-1983 for fabrication of composite door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed/ certifiedmake and brand as per direction of Engineer-In- Charge . (Payment will be made on finished length of the work). 22 (A) In 10-12 Micron thickness Annodizing film. 23 (I) NaturalWhite. 24 (k) Movable door shutter. 25 (ii) Shutter : 26 (a) Top rail.. 27 Supplying profiles of requredsection made of Aluminium Alloy extrusions conforming to IS:732-1983 and IS:1285-1975; Annodized (with required film thickness and specified colour/natural) matt finished conforming to IS: 1868-1983 for fabrication of composite door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed/ certifiedmake and brand as per direction of Engineer-In- Charge . (Payment will be made on finished length of the work). 28 (A) In 10-12 Micron thickness Annodizing film. 29 (I) NaturalWhite. 30 (k) Movable door shutter. 31 (ii) Shutter : 32 (b) Bottom rail. 33 Supplying bubble free float glass of approved make and brand. Conforming to IS: 2835-1987. 34 (ii) 4 mm thick coloured / tinted / smoke glass. 35 Providing and fixing exterior quality Aluminium Composite Panel (ACP)wall cladding on existing Al. /MS frame work with GI brackets, ACP fixedon the existing frame work by folding the edges of ACP panel (Engravingthe rear surface of ACP sheet) with CP angles, cleats and strainless Steelscrews forming groves at the periphery of ACP panel. Such grooves filledwith foam and silicon sealant etc. complete with all materials (butincluding the cost of silicon sealant), labour, scaffolding and all otherincidental charges complete in all respect as per specification anddirection of Engineer-in-charge. (Mode of payment is on finished surfacearea of ACP) 36 (b) 4mm thick (0.50mm Al.+3.0mm LDPE +0.50mm Al. PVDF coating) 37 (II) Cement concrete with 30 mm. down graded shingles excluding shuttering.N.B. VarietyIn ground floor . 38 (a) 1:3:6 proportion. 39 Hire and labour charge for shuttering with centreing and necessary staging up to 4 m. using approved stout props and thick hard wood planks of approved thick ness with required bracing for concrete slabs, beams, columns, lintels curved or staight including fitting fixing and striking out after complection of works. (up to roof of ground floor). 40 (f) 25mm. To 30mm. Shuttering with out staging in foundation etc. 41 Ordinary cement concrete (mix 1:1.5:3) with graded stone chips (20mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant codes. 42 (ii) River bazree. 43 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc.initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at inter-section, complete as per drawing and direction. 44 (a) For works in foundation, basement and up to roof of ground floor/up to 4m. Tor steel/Mild steel. 45 SAIL/ TATA/RINL 46 Supplying, fitting and fixing white vitreous china Sink in position on C.I. brackets including two coats of painting of brackets. . 47 Plain edge sink with over flow. 48 610mm x 450mm x 200mm. 49 Suppling, fitting and fixing Wall mounted water closet of white glazedvitreous chinaware of approved make and brand in position complete withnecessary nut and boalts (Equivalent to Code No. 20061 or 92065 &Model Studio or Rubbic of Hidware or equivalent.)(This item to be executed on specific permission of SuperintendingEngineer 50 Supplying, fitting and fixing bib cock or stop cock. 51 Chromium plated Bib Cock long body with wall flange with aerator (Equivelent to Code No.512 & Model- Tropical /sumthing special of ESSCO or Similar brand). 52 Supplying, fitting and fixing bib cock or stop cock. 53 Chromium plated Stop Cock (Equivelent to Code No.513(A) & 513(B) Model- Tropical /sumthing special of ESSCO or Similar brand). 54 Supplying, fitting and fixing PVC pipes of approved make ofof Schedule 80 (medium duty) conforming to ASTMD-1785 and threaded to match with GI Pi;es as per IS:1239 (Part-I) with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting piles, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accessories, specials. Payment for painting will be made seperately). 55 For Exposed Work PVC Pipes. 56 50 mm. 57 (a) M.S. orW.I. ornamental grill of approved design joints continuously welded with M.S., W.I. flats and bars for windows ,railing etc. fitted and fixed with necessary screws and lugs in ground floor.(Add extra @1% for each addl. floor up to 4th floor and @1.25% for each addl. floor above 4th floor). 58 (i) Grill weighing above 10 kg./sq.m.and up to 16kg/sq.m. 59 18% gst 60 1% lwc