| 1 | Taking and refixing existing pre painted galvalume roof sheeting of any thickness and any colour as in roof covering including fixing unserviceable self tapping screws and washers with newself tapping screws and washers complete all as specified and directed. Note :- The quoted rate shall deemed to be included for new self tapping screws with 3mm EPDM seal and washers for fixing the sheets to make the roof leakproof completely |
| 2 | Dismantling of plain or corrugated steel sheeting any guage, thickness including nainital or similar pattern in roof covering complete all as specified and directed. |
| 3 | S&F pre painted galvalume Aluminium Zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with suitable length self tapping screws to wooden/steel truss as per site requirementcomplete all as specified and directed. |
| 4 | S&F pre painted galvalume Aluminium Zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in ridges, roof overing/cladding to wall, fixed with suitable length self tapping screws to wooden/steel truss as per site requirementcomplete all as specified and directed. |
| 5 | S&F 1.00mm thick plain, galvanised, mild steel sheeting in valley gutters, drip and straight flashing (for covering crumple joints) with grade of Zinc coating 275 fixed to wood or steel member and wall, welded or shouldered joints are provided, including bending as required shape as per site condition, turning up, mitred angles, stopped ends, outlets etc complete all as specified anddirected. |
| 6 | M&Lfor roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust and brushing with neat cement slurry @ 3Kg of cement per Sq meter including removing existing tarfelting complete all as specified anddirected. |
| 7 | M&Lfor50mm thick PCC 1:2:4, type B1 (using 20mm graded crushed stone aggregates) as in floors and pavings padding concrete/levelling course complete finished even and smooth without using extra cement complete all as specified anddirected. |
| 8 | M&Lfor 10mm thk rendering in CM(1:3) mixed with water proofing compound as per manufacturer instruction on concrete surface and making the surface even and smooth as in required slope for draining out the rain water complete all as specified anddirected.Note:-Water proofing compound shall be measured and paid separately as supply only |
| 9 | M&L for cleaning and preparation of the surface to receive Fosroc Proofex ORGor its equivalent in approved make water proofing system shall be a sound base, any crack shall be treated with cementious repair mortar of Fosroc Renderoc CS or epoxy crack filling mortar by proper grooving arrangement complete all as specified anddirected. |
| 10 | M&L forTPO membrane of non-flammable waterproofing of roof which shall be a 1.5mm thick loose laid membrane using Fosroc ORG membrane or its equivalent in approved make layers are overlapped to achieve a minimum weld of 110mm, Hot air welding can be either hand applied or by means of automatic machines and the rolls either end are overlapped with layers of non-woven geotextile fiber, the separation layer provided to prevent the mechanical abrasion and cushioning between the Fosroc Proofex ORG membrane or its equivalent in approved make and the concrete substructure, the termination of Fosroc Proofex ORG or its equivalent in approved make by aluminium strip anchoring complete all as specified anddirected..Note: Work shall be executed by authorised applicator with prior experience of more than 5 years in applying similar system. |
| 11 | Supply only liquid water proofing compoundcomplete all as specified and directed |
| 12 | M&Lfor cutting grooves in wall 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed. |
| 13 | Taking down cement plaster on brick/concrete/stone masonry walls etc incl racking out joints, hacking for key, scrubbing down with water etc complete including removing rubbish off the premisescomplete all as specified and directed |
| 14 | M&Lfor rendering 10 mm thick on surface other than fair face of block masonry/brick workin CM (1:6) for wall finished even & smooth without using extra cementcomplete all as specified and directed |
| 15 | M&Lfor rendering 5 mm thick on brick work or concrete surface in CM (1:3) for ceiling finished even & smooth without using extra cementcomplete all as specified and directed |
| 16 | M&Lfor 15 mm thick cement plaster on fair face of brick work or concrete surface in CM (1:4) in two coats (5mm setting coat mixed with WPC over 10mm thick backing coat) for wall finished even & smooth complete all as specified anddirected.Note:-Water proofing compound shall be measured and paid separately as supply only. |
| 17 | M&Lfor preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali-resistant priming paints over 1mm thick wall care putty complete all as specified anddirected. |
| 18 | M&Lfor preparing newly plastered ceilings surfaces and applying three coat of white wash complete all as specified anddirected. |
| 19 | M&Lfor applying twocoats ofacrylic emulsion paintof Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives over and including priming coat of exterior primer applied on new plastered surfacesofwallscomplete all as specified anddirected. |
| 20 | M&L forpreparing old painted ceiling surfaces and applying one coat of white wash complete all as specified anddirected. |
| 21 | Demolition of cement concrete (unreinforced) of any description and in any position complete all as specified anddirected. |
| 22 | M&Lfor preparation of floor and wall surfaces, treatment and sealing of all joints, corners, junctions of pipes and Masonry with polymer mixed slurrycomplete all as specified anddirected. |
| 23 | M&Lfor applying first layer of cement slurry at 0.488 kg/ sqm mixed with Acrylic based polymer \"ARMOUR -CRETE\" of structural water proofing pvt ltd by ratio 1:2 (one Armour Crete : Two cement) or \"POLYCRYL\" of Green boro polychem pvt ltd by ratio 1:2 (one polycryl : Two cement) or Ready to use PIDIFIN 2k of PIDILITE INDUSTRIES or SHALICRETE-500 of capital steel and chemicals pvt ltd and silica sand by ratio 1:2:2 (Shalicrete : Cement : Silica Sand) or NAFUFILL BB2 of MC Bauchemic India Pvt Ltd (ready to use) at 0.126 kg/sqm as per manufacturers instructions complete all as specified anddirected. Note:-This layer will be allowed to Air Cure for 4 hours |
| 24 | M&Lapplying second layer of 1.5mm to 2.0mm thick slurry of cement at 0.242kg/sqm mixed with acrylic based polymer \"ARMOUR CRETE\" of structural water proofing pvt ltd and silica sand by ratio 1:2:2 (Armour -crete : cement : silica sand) or \"POLYCRYL\" of Green boro polychem pvt ltd and silica sand by ratio 1:2:2(Polycryl : cement : silica sand) or ready to use PIDIFIN 2k of PIDILITE INDUSTRIES or SHALICRETE-500 of capital steel and chemicals pvt ltd and silica sand by ratio 1:2:2 (Shalicrete : Cement : Silica Sand) or NAFUFILL BB2 of MC Bauchemic India Pvt Ltd (ready to use) at 0.126 kg/sqm as per manufacturers instructions complete all as specified anddirected. Note:-This layer will be allowed to Air Cure for 4 hours followed by water curing of 48 hours |
| 25 | M&L forPCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregates) as in foundation, filling and mass concrete all as specified |
| 26 | M&Lfor non-skid Ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tiles exceeding 0.06 sqm but not exc 0.11 sqm as in floorsset and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles laid over and including cement screed 15 mm thick in CM(1:6) complete all as specified and directed. |
| 27 | S&F vitreous Chinawash down water closet (pedestal pattern), white with \"P\" trap(excluding fluhing cistern and flush pipe) including PVC seat cover complete all as specified anddirected |
| 28 | S&F vitreous China squatting pan Orissa pattern of size 630mm x 450mm white with integral foot rest (excluding flushing cistern and flush pipe) including lime concrete bedding all round and finished just below level of rim of pan to receive the floor complete all as specified anddirected |
| 29 | S&F75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified anddirected |
| 30 | S&F75mm bore PVC (SWR) multi floor trap, plain with grating including jointing with solvent complete all as specified anddirected |
| 31 | S&F in repairs PVC SWR pipe75 mm bore, single socketed in any length with rubber ring joints,fixed to walls including mild steel clamps of suitable size complete all as specified anddirected |
| 32 | S&F in repairs PVC SWR pipe110 mm bore, single socketed in any length with rubber ring joints,fixed to walls including mild steel clamps of suitable size complete all as specified anddirected |
| 33 | S&F 75 mmbore PVC (SWR) bend of any radiuscomplete all as specified anddirected |
| 34 | S&F110 mmbore PVC (SWR) bend of any radiuscomplete all as specified anddirected |
| 35 | S&F75mmbore PVC (SWR) junction single, (single T) equal or unequal with access doorcomplete all as specified anddirected |
| 36 | S&F 110mmbore PVC (SWR) junction single, (single T) equal or unequal with access doorcomplete all as specified anddirected |
| 37 | S&F75mm dia PVC vent cowlcomplete all as specified anddirected |
| 38 | S&F 75mm dia bore PVC (SWR) bend with oval access door of any radiuscomplete all as specified anddirected |