| 1 | Earth work in excavation in foundation trenches in ordinary soil(Loam,Clay or Sand) including laft upto 1.50 M and lead up to 30m and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the side of the foundation trenches ot into the plinth and rewmoval and disposal of surplus Earth as directed by the engineer-in-charge up to a distance of 30m from the foundation trenches.SI No 251 page 25 |
| 2 | Cement Concrete with 4 cm. gauge stone ballast, fine sand of 1.25 F.M. & cement in proportion of 10:5:1 in foundation & under floors including supply of all materials. labour. Tools & plants etc. required for proper completion of the work SI NO 274 SOR 2022 page 27 |
| 3 | Providing and laying in position specified grade of reinforcement cement concrete, including the cost of centering shuttering finishing and excluding reinforcement All upto plinth level 1:1.5:3 (1Cement:1.5Coarse sand:3Stone Aggregate 20mm nominal size)for FootingUPPWD SOR 2022SI no 5.1.2 |
| 4 | RCC Work in walls including attacked Pilasters buttresses plinth and string course fillet column pillar piers abutments posts and struts etc.including cost of centering shuttering finishing and excluding Reinforcement with 1:1.5:3(1Cement:1.5Coarse sand:3Stone Aggregate 20mm nominal size)for ColumnUPPWD SOR 2022SI no 5.3 |
| 5 | Brick work with common burnt clay F.P.S (non modular) bricks of class Mdesignation -100 class brickwork 1:6 Cement and Coarse sand for foundation and PlinthUPPWD SOR 2022SI no 6.1.2 page 30 |
| 6 | RCC Work in walls including attacked Pilasters buttresses plinth and string course fillet column pillar piers abutments posts and struts etc.including cost of centering shuttering finishing and excluding Reinforcement with 1:1.5:3(1Cement:1.5Coarse sand:3Stone Aggregate 20mm nominal size)for Plinth BeamUPPWD SOR 2022SI no 5.2.2 |
| 7 | M.S. (tor steel or plain) in plain work such as R.C.C. Or R.B. Work including bending for proper shape & including supply of steel & its wastage, bend, hooks and authorised overlaping shall be measured and including cost of binding wire 16 mm dia bar used (8mm to 16 mm) |
| 8 | Earthwork in filling or in embankment in ordinary soil. including cartage or earth from 8 Km any where out side the limit of regulated area distance and including loading unloadingof earthetc. required for proper completion of the work.Approved Rate |
| 9 | Brick work with common burnt clay F.P.S (non modular) bricks of class designation -100 class brickwork 1:6 Cement and Coarse sand for foundation and PlinthUPPWD SOR 2022SI no 6.4.2 page 30 |
| 10 | RCC Work withforBeam suspended floor roof having slope upto 15 degree landing balconies shelves chajjas lintels band plain window sill staircase and spiral stair cases above plinth level upto floor five level including the cost of centering shuttering finishing and excluding reinforcement with1:1.5:3(1Cement:1.5Coarse sand:3Stone Aggregate 20mm nominal size)forUPPWD SOR 2022SI no 5.3 (LINTELS) |
| 11 | RCC Work withforBeam suspended floor roof having slope upto 15 degree landing balconies shelves chajjas lintels band plain window sill staircase and spiral stair cases above plinth level upto floor five level including the cost of centering shuttering finishing and excluding reinforcement with1:1.5:3(1Cement:1.5Coarse sand:3Stone Aggregate 20mm nominal size)for BEAM UPPWD SOR 2022SI no 5.3 |
| 12 | RCC Work withforBeam suspended floor roof having slope upto 15 degree landing balconies shelves chajjas lintels band plain window sill staircase and spiral stair cases above plinth level upto floor five level including the cost of centering shuttering finishing and excluding reinforcement with1:1.5:3(1Cement:1.5Coarse sand:3Stone Aggregate 20mm nominal size)for COLUMNUPPWD SOR 2022SI no 5.3 |
| 13 | RCC Work withforBeam suspended floor roof having slope upto 15 degree landing balconies shelves chajjas lintels band plain window sill staircase and spiral stair cases above plinth level upto floor five level including the cost of centering shuttering finishing and excluding reinforcement with1:1.5:3(1Cement:1.5Coarse sand:3Stone Aggregate 20mm nominal size)for SLABUPPWD SOR 2022SI no 5.3 |
| 14 | M.S. (tor steel or plain) in plain work such as R.C.C. Or R.B. Work including bending for proper shape & including supply of steel & its wastage, bend, hooks and authorised overlaping shall be measured and including cost of binding wire 16 mm dia bar used (8mm to 16 mm) |
| 15 | M S Iron Work for grill balcony and staircase railing of approved quality and drawing including supply of all material fabrication labour T&P etc in all respect as per direction of Engineer-In-Charge for proper completion of work. UPPWD SOR 2022 SI no 16new page 44 |
| 16 | 12mm thick cement plasteron brick work with cement mortar of mix 1:4 (1cement:4Coarse sand) UPPWD SOR 2022 SI no 584 (ii)page 55 |
| 17 | 15mm thick cement plasteron rough side og single or half brick wallwith cement mortar of mix 1:4 (1cement:4Coarse sand) UPPWD SOR 2022 SI no 2new page 55 |
| 18 | Supply and Fixing of S.S Mosquito proof heavy quality iron wire gauge or expanded metal heavy quality over window and including supply of C.P teak wood batten 8cmx1cm flat iron 25mm x 4mm and including supply of necessary screw all material labour totl and plant etc required for proper completion of work. UPPWD SOR 2022Page 35 SI No 455(a) |
| 19 | Providing and laying vitrified floor tiles in different sizes with water absorption less than 0.8% and confirming to IS: 15622, of approved make in all colours and shades laid on 20mm thick cement motar 1:4 (1 cement: 4 coarse sand ), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc, complete.With Base page 59 |
| 20 | Providing and Laying \"Brick Coba\" 12mm thick laid with M-100 class brick bat coba 7.50cm thick with gap of 15mm to each other over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreding cement slurry mixed with acrelic cement concrete water proofing compound in1:4 cement and coarse sand mortar finished smooth and top mashed false squre 30cmx30cm and side wall parapet shall be mono tythic plaster wall upto 30cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight and including supply of all material labour T&P etc complete for proper completion of work.UPPWD SOR 2022 Page 46 |
| 21 | Providing and Applying white cement based putty of average thickness 2 mm of approved brand and manufacture, over the plastered wall surface to prepare the surface even and smooth complete including cost of all material Labour T&P etc. Complete required for proper completion of the work.SINo 13.80 UPPWD SOR 2022 Page 61 |
| 22 | Painting two coat orincluding preparing the surface by thoroughly clearingthe surface of all dirt dust and scrapping and papering Including cost of all material labour T&P etc required for proper completion of work.UPPWD SOR 2022 SI no (2New+3New)(33+80)=113 Page 61 |
| 23 | Distempering with oil bound distemper (first coat including priming coat)of approved brand and manufacture on undercoated wall surface to give an even surface including supply of all material labour and T&P etc required for proper completion of work.UPPWD SOR 2022 SI No (649+2x650)Page 62 |
| 24 | Finishing wall (Two Coat ) with exteriorpaint (Apex) of approved brand and manufacture and of required shade on undercoated wall surface to give even shade including one coat of primer applied curing cost of all material labour T&P etc.UPPWD SOR 2022 SI No 21new Page 63 |
| 25 | Electrical Works |
| 26 | Point Wiring in PVC Conduit, with Modular Type Switch Wiring Point for Light with 1.5 Sq.mm |
| 27 | Wiring Point for Fan/Fresh Air Fan |
| 28 | Wiring Point for Plug with 1.5 Sq.mm. |
| 29 | Suuply & Fixing Power Plug With |
| 30 | Supply & Fixing of Switch Box Made 175x100x65 mm Size |
| 31 | Supply & Wiring of circuit wiring with two number 2.5 Sq.mm. FRLSH PVC |
| 32 | Supply & Wiring of circuit wiring with two number 4 Sq.mm. FRLSH PVC |
| 33 | Supplying And Fixing of 6Amp to 32 Amp SP MCB (10KA) C Curve |
| 34 | Supply & Fixing/Flush Mountain 8 Way SPN Distribution Board |
| 35 | Supply & Fixing of Fan Box With hexagonal Side of |
| 36 | Supply of Ceiling Fan mototr of A.C Permanent insulation, capacitor rating confirming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated voltage 220/240 volts,50Hz,1-ph AC the fan assemble should consist of down rod blades, shackle canopies etc and with double ball bearing system (BEE 4 Star rated-1200mm Sweep) SI No 1501(ii) (ELECTRICAL WORKS) |
| 37 | Supply And Fixing of LED Tube Light1x22 watt, 2200 system lumens 100lm/watt PF>0.95 THD<10%,CRI>80,Tube with aluminium heat with 3 year warrantee with polycarbonate tube light complete including tube suitable for both surface and suspended complete in all respect.SI No 1413 (ii) (ELECTRICAL WORKS) |