| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | All kinds of soil. |
| 3 | Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth |
| 4 | 1:5:10 (1 cement : 5 coarse sand (zone-Ill) derived from naturalsources :10gradedstoneaggregate40mm nominal size derived from natural sources) |
| 5 | Providing and laying in position specified grade of reinforced cement concrete,excludingthecostofcentering,shuttering,finishingand reinforcement - All work up to plinth level : |
| 6 | 1:1.5:3(1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 8 | Foundations,footings,basesof columns,etc.formass concrete |
| 9 | Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete upto plinth level. |
| 10 | Thermo-Mechanically Treatedbars of gradeFe-500D or more. |
| 11 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 12 | Cement mortar 1:6(1 cement :6 coarse sand) |
| 13 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 14 | Cement mortar 1:6(1 cement : 6 coarse sand) |
| 15 | Providing and fixing wire gauge shutters using galvanizedM.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : |
| 16 | 35 mm thick shutters |
| 17 | withISImarkedM.S.pressedbutthinges bright finished of required size |
| 18 | Kiln seasoned and chemicallytreatedhollock wood |
| 19 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 20 | 250x16 mm |
| 21 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 22 | 200x10 mm |
| 23 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 24 | 100 mm |
| 25 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 26 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 27 | Hot finished welded type tubes |
| 28 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 29 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. |
| 30 | Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides |
| 31 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with: |
| 32 | 4.0 mm thick glass panes |
| 33 | Providing and fixing precoated galvanised iron profile sheets (size, shape andpitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheet shallbe fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 34 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 35 | Ridges plain (500- 600mm) |
| 36 | 12 mm cement plaster of mix: |
| 37 | 1:6 (1 cement: 6 coarse sand) |
| 38 | 15 mm cement plaster on rough side of single or half brick wall of mix: |
| 39 | 1:6(1 cement: 6 coarse sand) |
| 40 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour: |
| 41 | New work(twoormorecoats)over andincludingwater thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 42 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete. |
| 43 | On steel work |
| 44 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 45 | Two or more coats on new work |
| 46 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 47 | One or more coats on old work |
| 48 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 49 | Old work (Two or more coat applied @ 1.67 Itr/ 10 sqm) on existing cement paint surface |
| 50 | Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge. (a) Internal Work- Exposed on wall |
| 51 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : |
| 52 | Of area 3 sq. metres and below |
| 53 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 54 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : |
| 55 | For fixed portion |
| 56 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 57 | Forshuttersofdoors,windows&ventilatorsincluding providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 58 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 59 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 60 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 61 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. |
| 62 | Upto 5 mm depth and 5 mm width |
| 63 | Providing & fixing false ceiling at all heights withGRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanized @ 120 gram per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600 mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 64 | With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles. |
| 65 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite)soliddoor/window/Clerestorywindows&otherFrames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A categorywithpropertyofbeingtermite/borerproof,water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and lengthcomplete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.edepth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 66 | Frame size 65 x 100 mm |
| 67 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white color and other side of board laminted with PVCfoil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and bathroom/ kitchen cabinet etc. of required sizes comprisingof virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread offlame of Class Acategory with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge.(Note: stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws shall be paid separately) |
| 68 | 25 mm thick |
| 69 | Cost of DSR items = Rs. 14,11,370.09 ADeduct GST Factor on DSR-2023 Items @ total of DSR rates - 0.973 of DSR rates) i.e. 14,11,370.09 - 0.973 A = Rs.38,106.99 |
| 70 | Credit for MS section like angle, tee, flats, grill etc. |
| 71 | Credit for SCI/CI pipe |
| 72 | Credit for G.I. pipe |
| 73 | Credit for CP fittings etc |
| 74 | Electrical |
| 75 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 76 | Group A |
| 77 | Group B |
| 78 | Group C |
| 79 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 80 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 81 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 82 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 83 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 84 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 85 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. |
| 86 | Group A |
| 87 | Group B |
| 88 | Group C |
| 89 | Supplying and drawing following size of FRLS PVC insulated copper conductor single core cable in the existing surface/ recessed steel/ PVC conduit as required |
| 90 | 1 x 1.5 sq. mm |
| 91 | 2 x 1.5 sq. mm |
| 92 | 3 x 1.5 sq. mm |
| 93 | 4 x 1.5 sq. mm |
| 94 | 5 x 1.5 sq. mm |
| 95 | 6 x 1.5 sq. mm |
| 96 | 9 x 1.5 sq. mm |
| 97 | 1 x 4 sq. mm |
| 98 | 3 x 4 sq. mm |
| 99 | 6 x 4 sq. mm |
| 100 | 3 x 6 sq. mm |
| 101 | 2 x 10 sq. mm + 1 x 6 Sq.mm |
| 102 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 103 | 20 mm |
| 104 | 25 mm |
| 105 | 32 mm |
| 106 | 40 mm |
| 107 | 50 mm |
| 108 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 109 | 5/6 A switch |
| 110 | 15/16 A switch |
| 111 | 3 pin 5/6 A socket outlet |
| 112 | 6 pin 15/16 A socket outlet |
| 113 | Bell push |
| 114 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 115 | 5/6 A switch |
| 116 | 2 way 5/6 A switch |
| 117 | 15/16 A switch |
| 118 | 3 pin 5/6 A socket outlet |
| 119 | 6 pin 15/16 A socket outlet |
| 120 | Telephone socket outlet |
| 121 | TV antenna socket outlet |
| 122 | Bell push |
| 123 | 6 A to 32 A rating, 240 V,\"C\" curve, SPmodular MCB |
| 124 | 25 amp switch |
| 125 | Computer Jack ( RJ 45)Cat6 (1 module) |
| 126 | Supplying and fixing two module stepped type electronic piano fan regulator on the existing phenolic cover plate switch box including connections but excluding cover plate etc. as required. |
| 127 | Supplying and fixing one module stepped type electronic piano fan regulator on the existing phenolic cover plate switch box including connections but excluding cover plate etc. as required. |
| 128 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 129 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 130 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 131 | 1 or 2 Module (75mmX75mm) |
| 132 | 3 Module (100mmX75mm) |
| 133 | 4 Module (125mmX75mm |
| 134 | 6 Module (200mmX75mm) |
| 135 | 8 Module (125mmX125mm) |
| 136 | 12 Module (200mmX150mm) |
| 137 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 138 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 139 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 140 | Supply, installation, testing and commissioning of surface mountedLED downlighter luminaire inmetallic housing, with a minimum system lumen output of 1500 lumen andwith a minimum system luminous efficacy of 100 lm/W, Average LED life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, diffuser and electronic driver, directly on ceiling, including connections and earthing etc. as required. |
| 141 | Installation, testing, commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/ CFL / LEDlamps per fitting/ /Downlighters/ LED Panel Light /LED batten on wall or ceiling, complete with all accessories including connection and earthing etc. as required. |
| 142 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq, mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 143 | Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 144 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 145 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. |
| 146 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 16 amp modular socket outlet and 16 A /25 A modular SP MCB, \"C\" curve including connection, painting etc. as required. |
| 147 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 148 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 149 | 12 way , Double door |
| 150 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 151 | Single pole |
| 152 | Double pole |
| 153 | Supplying and fixing following rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 154 | 40 A Double pole |
| 155 | 63 A Double pole |
| 156 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 157 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 158 | 63 A |
| 159 | Providing and fixingMS fan hook on the existing ceiling truss withnut, bolt, etc., complete as required. |
| 160 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 161 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling etc as required. |
| 162 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 163 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclo sure with cover plate having locking arrangement and wa tering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 164 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 165 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 166 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, down rod upto 30 cm long , 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 8, Air delivery minimum 215 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%,without remote and compatible with existing step electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (BLDC Ceiling fan with minimum 2 year Warranty ) |
| 167 | Supply, installation, testing, and commissioning of integrated LED Batten luminaire, 1100 mm (nominal size) with a minimum system lumen output of 4800 lumen and with a minimum system luminous efficacy of 120 lm/W, made of aluminium housing having a colour temperature5500K - 6500 K, Average life L70B50: 50000 hours, THD ≤ 10%, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling/wall, including connections, earthing, etc. as required. |
| 168 | Supply, installation, testing, and commissioning of integrated LED Batten luminaire, 1100 mm (nominal size) with a minimum system lumen output of 2400 lumen and with a minimum system luminous efficacy of 120 lm/W, made of aluminium housing having a colour temperature5500K - 6500 K, Average life L70B50: 50000 hours, THD ≤ 10%, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling/wall, including connections, earthing, etc. as required. |
| 169 | Supply, installation, testing, and commissioning of integrated LED Batten luminaire, 600 mm (nominal size) with a minimum system lumen output of 1000 lumen andwith a minimum system luminous efficacy of 100 lm/W, made of aluminium housing having a colour temperature5500K - 6500 K, Average life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling/wall, including connections, earthing, etc. as required. |
| 170 | Supply, installation, testing, and commissioning of LED bulkhead fittings with IP 66 ingress protection, with a minimum system lumen output of 1000 lumens and a minimum system luminous efficacy of 100 lm/W, made of aluminium housing having a colour temperature of 5500K–6500 K, average life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, diffuser, electronic driver, etc. as required directly on the wall, including connections, etc. as required. |
| 171 | Supply, installation, testing, and commissioning of 2 ft. x 2 ft. (nominal size) LED recessed Mounted LED Panel Light, in metallic housing, with a minimum system lumen output of 3960 lumens and a minimum system luminous efficacy of 110 lm/W, colour temperature of 5500K–6500K, average life L70B50: 50000 hours, THD ≤ 10%, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, suitable for recessed mounting, Armstrong/grid/POP/GB ceiling complete with all accessories, diffuser and electronic driver, directly on the ceiling, including connections and earthing etc. as required. |
| 172 | Supplying and installation of PVC Exhaust fanwith louver shutter 250 mm sweep in the existing opening, including making good the damage,including connections, earthing,testing, commissioning etc as required.(Havells / C&G / Orient / Usha / Almonard/ Atomberg) |
| 173 | Rewinding of following size ceiling fan / exhaust fan/ Wall fanmotor including complete removal of existing burnt out winding and rewinding of the fan with suitable size enameled copper wire, including sleeving, suitable insulation materials, varnishing etc., complete with dismantling and reassembling after repair, including connection testing etc. as required. Removed winding wire shall be retained by the contractor and suitably credited with its value and net value to be quoted. |
| 174 | 1200mm Sweep ceiling fan |
| 175 | 1400mm Sweep ceiling fan |
| 176 | Rewinding of stator winding of following size exhaust fans with suitable size enameled copper wire (as per manufacturer specification) including slaving of stator suitable insulation materials ie “E” class varnish complete with dismantling and reassembling after repair i/c connection testing etc as required (Brunt copper wire will be retained by the contractor). |
| 177 | 300mm / 380 mm exhaust fan |
| 178 | 450 mm exhaust fan |
| 179 | Providing and replacing ball bearing in following sizeceiling fan/exhaust fan, including removing old ball-bearing, installing new ball bearing and testing the fan, etc., as required.(Scrap material will be retained by the contractor).(Both side shield ball bearing of SKF/ NBC /TATA ) |
| 180 | 1200mm Sweep ceiling fan. |
| 181 | 1400mm Sweep ceiling fan. |
| 182 | 300mm/ 380 mm exhaust fan |
| 183 | 450 mm exhaust fan. |
| 184 | Providing and replacing2.5 MFD fan capacitor in the ceiling fan/exhaust fan/wall fan, including connection and testing, etc., as required. (The old capacitor will be retained by the contractor). |
| 185 | Reconditioning of the oversized bush /bearing housing to a suitable ball bearing in the ceiling fan/ exhaust fan/ wall-mounted fans as required and assembling and testing of the fan after repair. All the scrap material should be retained by the contractor. |
| 186 | Providing and replacing the worn-out M.S. shaft of the exhaust fan /wall fan with a suitable size new shaft etc., as required, including removing the old shaft, installing the new shaft, and testing the fan.All the scrap material should be retained by the contractor. |
| 187 | Providing and fixing PVC clamp with connector for the ceiling fan capacitor in the existing ceiling fan, including connection, testing, etc., as required, including credit for the old PVC clamp, which will be retained by the contractor. |
| 188 | Supplying, installation testing and commissioning of BEE5 star rating, 25 litres capacity water storage heater, withprotection against over heating, Multifunction Safety Valveandexternal adjustable thermostat, with16 A, 240 V, plug topand02 nosflexible connection pipe suitable for working with 230V AC, 50 Hz, 1 Phase supply etc as required. (Make:Havells / Crompton/ AO Smith /Racold /Jaguar with 7 year warranty on inner tank, 3 year warranty on heating element, 2 year comprehensive Warranty) |
| 189 | Supplying and fixingPlasticBatten/Angle holder alonwith9/10 watt LED blub including connection etc. as required. |
| 190 | Providing and fixing 3 mm thick PVC/phenolic laminatedround sheet cover with a minimum of 170 mm dia on the existing fan box with two screws, etc., as required. |
| 191 | Providing and fixing 3 mm thick PVC / phenolic laminatedround sheet cover on the existing junction boxwith two screws, etc., as required. |
| 192 | Fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 193 | 6 to 16 way,Double door |
| 194 | Fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 195 | Single pole |
| 196 | Single pole and neutral |
| 197 | Double pole |
| 198 | Triple pole |
| 199 | Triple pole and neutral |
| 200 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 6 pin 15/16 A modular socket outlet and 2 nos. 151/6 A modular switch, connections etc. as required. |
| 201 | Supplying and fixing Plug top following rating including connection etc. as required. |
| 202 | 16 A, three pin, Plug top ISI marked |
| 203 | 6 A, three pin, Plug top ISI marked |
| 204 | Supplying and fixingBakelite Sheetof following size with screw in the existing looping box/ panelincluding cutting the sheet to required shape and size complete etc as reqd. |
| 205 | 6 mm thick |
| 206 | Supplying and laying of G.I. pipe of 50 mm dia.(nominal),medium class, ISI markedinwall / floorincluding cuttingchase, and making good the wall/ floor and finishing with matching surface after housing G.I. pipe in chase. ( for protection of UG cable) |
| 207 | Supplying, installation, testing and commissioning of 45 Watt LED street light luminaire made up of die-cast aluminium housing, with IP66 degree of protection, complete with the driver, LEDs with optical lens, toughened glass cover, etc. The luminaire should have suitable for operation on voltage range 140-270V, 1Φ, 50Hz AC supply system, and a mechanical impact resistance rating of lk>=07. surge protection of ≥ 10KV, PF≥ 0.90 and minimum system luminous efficacy of 100 lm/W. The luminaire shall be designed for an average system life L70B50: 50000 hours and suitable for mounting on the pole bracket up to outer dia 40 mm, including installation on existing street light pole bracket connections and earthing etc., as required. LM 79 and LM 80 reports need to be submitted from a NABL/UL accredited lab to verify the above parameters. |
| 208 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV /HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. |
| 209 | ADD labour cess @1 % onDSR 2022 (Elect.) amount Rs. 2,64,989/- |
| 210 | Add Difference in GST of(18 &12 %) by MF 0.0633 on DSR Elect i.e Rs. 2,64,989/- (DSR) + 2,649.89/- (L/Cess) = Rs. 2,67,638.89/- |
| 211 | Less COST INDEX on DSR(E) @ -2.73 % i.e Rs. 2,64,989/- (DSR) + Rs. 2,649.89/- (L/Cess) + Rs. 16,941.54/- (GST difference) = Rs. 2,84,580.43/- |
| 212 | Correction factor on existing items of DSR @ 0.973 as per CPWD office Memorandum 158/SE (TAS)/GST/2024/02-E DATED 8-8-2024 (U) i.e Rs. 2,64,989/- (DSR) + Rs. 2,649.89/- (L/Cess) + Rs. 16,941.54/- (GST difference) + 0.00 (DSR Civil) - Rs. 7,769.05/- (Cost Index) = Rs. 2,76,811.38/- |