| 1 | H-Beams 152 X 152 mm., 37.1 Kg./Mtr.-9 mtr.Long= 333.9 kg |
| 2 | H-Beams 152 X 152 mm., 37.1 Kg./Mtr.-11 mtr. Long = 408.1 kg |
| 3 | 140 Kg.,8.0 Mtrs. long PCC pole |
| 4 | 33/11 KV Power transformer , OFTC Type , 5000 KVA(LOSS 4KW + 23 KW) |
| 5 | 33/11 KV 3.15 MVA Power transformer Old |
| 6 | 33 KV VCB, Outdoor Porcelain cladtype with complete structure and accessories excluding CT & pannel |
| 7 | 33 KV CT Outdoor Oil immersed type, 3 Core,200-100/5-5-1 Amp, Class 0.5 for differential protection |
| 8 | 11 KV VCB, Outdoor Porcelain cladtype with complete structure and accessories excluding CT& pannel |
| 9 | 11 KV control & relay panel withstatic relay for Transformer protection |
| 10 | 33 KV, ISOLATOR600 AMP.(Turn and twist type) |
| 11 | 9 KV Gapless type(5 KA) polymer lightening arrestor |
| 12 | 33 KV Single Phase PTs. |
| 13 | 11 KV Pin Insulator Polymer Composit (5 KN) |
| 14 | 33 KV Pin Insulator Polymer Composite (10 KN) |
| 15 | 11 KV Top clamp 65X65X6 mm. angle type |
| 16 | 33 KV (45KN) Composite Polymer Disc Insulators |
| 17 | 11 KV(45KN) Composite Polymer Disc Insulators |
| 18 | 11 KV Strain hardware (T&C type) fittings |
| 19 | D.C. Cross-arms 8 ft centre to center (100x50x6mm)Channel |
| 20 | Copper Control Cable 4 Core. 2.5 Sq.mm. (Unarmoured) |
| 21 | Copper Control Cable 2 Core. 2.5 Sq.mm. (Unarmoured) |
| 22 | (v) ACSRDog conductor 0.10 sq. inch (100 sq.mm. Al.Eq.), (6/4.72 + 7/1.57 mm) |
| 23 | ACSRPanther conductor 0.20 sq. inch (200 sq.mm Al.Eq.) |
| 24 | Copper Control Cable 8 Core. 2.5 Sq.mm. (Unarmoured) |
| 25 | 33 KV control & relay panel withstatic relay for Transformer protection |
| 26 | 11 KV.C.Ts.(Outdoor dry type)300-150/5-5 Amps |
| 27 | 11 KV control & relay panel withnumerical static relay for double feeder protection |
| 28 | 11 KV, ISOLATOR800 AMP.(Turn and twist type) |
| 29 | 33 KV Polymer Lightening arrestor Gapless type |
| 30 | 11 KV Single Phase PTs. (Resin Molded) |
| 31 | 33 KV Top clamps 75x75x6 mm Angle |
| 32 | Horizontal & Cross Bracing set of MS angle of 50X50X6 mm for 8 ft (2.4 mtr ) centre DP |
| 33 | Galvanized Iron (GI) Flat 50X6 MM |
| 34 | D.C. Channel 100x50x6mm 4.8 mtrs center to center |
| 35 | D.C. Cross arms 5 ft centre to center (100x50x6 mm) Channel |
| 36 | Copper Control Cable 12 Core. 2.5 Sq.mm. (Unarmoured) |
| 37 | 3 phase 4 wire 3x63.5 volts lb=5 amps Imax = 10 amp, HTtrivector meter class of accuracy 0.5s, DLMS Compliant category A Meters along with GSM (GPRS compatible )modems(Forsubstation metering) |
| 38 | SHEET METAL METER BOX SUITABLE FOR H.T. STATIC TRAVECTOR METERS WITH TTB |
| 39 | Marshelling box with 10 no. connectors |
| 40 | T CLAMP FOR 33KV & 11KV BUS, SUBSTATION upto DOG |
| 41 | Bi Metallic Clamp for Power Transformer of Brass Flat 50x50x10MM |
| 42 | Clamp65X8 mm Flat of MS Flat for H-Beam ( Each weight 3.2 kg) |
| 43 | MS strain plate 65x8mm 250mm long |
| 44 | 33 KV composite polymer Strain set with hard ware suitable for Panther Conductor |
| 45 | Stone Block/Pre cast block for base pedding(450X450X75MM) |
| 46 | Concreting of structures & foundation (1:3:6) |
| 47 | Back Clamps for H-Beam of MS Flat 65x8mm (Each weight 1.92 Kg) |
| 48 | Stay set complete without Stay wire 16 mm. (Painted) |
| 49 | STAY WIRE 7/3.15 MM.(7/10 SWG) |
| 50 | Concreting of stay (20 mm / 25 mm) @ 0.3 cmt. per stay |
| 51 | Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire |
| 52 | Concreting of foundation of VCB (1:3:6) @ 3.5 cmt per VCB plinth |
| 53 | PTR Fndn.Cncrt.:1:1.5:3 Rio 5.634,1:5:8 Rio7.545 cmt&M.S.Flat/rod 324.87 kg |
| 54 | M.S.Nuts with Bolts |
| 55 | Red oxide paint |
| 56 | Aluminium paint |
| 57 | Danger Boards Enamelled 33 KV |
| 58 | Earthing Rod 3 mtrs.(Gelvanised) 25 mm Rod |
| 59 | Bentonite compound powder |
| 60 | GI Pipe 150 mm B Grade |
| 61 | CHEM ROD 50MM DIA.AND 2000 MM LONG |
| 62 | Erection cost |
| 63 | 18% (CGST+MPGST) on Erection cost |