| Sl. No. | Item Description |
| 1 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 mtr. Lead as per direction of Engineer -in-charge. 1:4:8 or leaner mix. (B-156/14.2.2) |
| 2 | Dismentling old plaster or skirting, raking out joints and cleaning the suerface for plaster including disposal of rubbish to the dumping within 50 mtr. Lead. (B-161/14.55) |
| 3 | Demolishing mud phuska / Lime dhar/ Kharanja in terracing and disposal of unserviceable material within 50 meters lead (B-159/14.27) |
| 4 | Supply and fixing wall machnines cut and polished stone slab shelbves, tands and in in cement mortar 1:3 with machines cut edges. Sand or other approved stone 50mm thick (B-75/6.52) |
| 5 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size). (B-54/3.1.7) |
| 6 | Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand). (B-69/6.1.6) |
| 7 | Random Rubble stone masonry with hard stone in superstructure aboveplinth level and upto five levelabove 30cm. thick walls in :Cement Mortar 1:6 ( 1-Cement : 6-Sand).Wall upto 30cm. and less thickness. (B-69/6.2.6) |
| 8 | Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering.M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). (B-55/3.2.4) |
| 9 | Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. (B-109/10.24) |
| 10 | Half brick masonry in Superstructure , above plinth level upto floor Vlevelusing bricks of designation 75Cement mortar 1 : 6 (1 cement : 6 coarse sand)Add extra providingand placing in position 2 Nos. ,6mm Ø M.S. barat every thirdcourse of half brick masonry . (B-66/5.8.3+5.9) |
| 11 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :25 mm thick (B-139/12.3.1) |
| 12 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick (B-139/12.3.2) |
| 13 | 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) (B-139/12.5) |
| 14 | Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish :25 mm thick. (B-139/12.2.1) |
| 15 | Supplying and fixing in walls machine cut and polished stone shelves, tands andin CM 1:3 with machine cut edges :Kota stone minimum 30mm thick. (B-72/6.17.3) |
| 16 | Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand)For area of each slab from 2001 to 5000 Sq.Cm (B-132/11.18.2) |
| 17 | Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand)For area of each slab from 901 to 2000 Sq.Cm :(B-132/11.18.1) |
| 18 | Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing completeFor area of each slab from 2001to 5000 Sqcm (B-132/11.19.2) |
| 19 | Providing and fixing steel glazed window frame made out of 80x40 mm hollow sheet section of 16 gauge thickness, joint mitred weldedand grinded including hold fast of steel lugs 13mm x 3mm and 15 Cm long embedded in C Cblock 15 x 10 x 10 Cm of 1:3:6 nominal concrete and including fixing of pivoted hinges of superior quality, window shutters made out of 50 x 25.0 mm hollow steel section 15 mm paitam of 18 gauge thickness, joint mitred and grinded including 10mm x 10mm square bars welded to framefor paitam fixing float glass 4mm thickpanes with glazing clips and metal sash putty andfixing of shutters frames peg stay, U shape handle 100 mm long, tower bolts 100 mm long of steel powder coated superior quality including fixing and jointing with frame hinges priming coat with steel primer complete in all respect as per direction of Engineer-in –charge Window openable.(B-102/9.28.1) |
| 20 | Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. (B-102/9.26) |
| 21 | Providing and fixing Square bars or other flat welded to window, ventilatiors etc. (B-102/9.27) |
| 22 | Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification : (B-56/3.8) |
| 23 | Pointingonstonemasonryincementsandmortar 1:3 (1 cement : 3 sand) :Flush / Ruled/ Struck or weathered pointing (B-143/12.31.1). |
| 24 | Pointingonstonemasonryincementsandmortar 1:3 (1 cement : 3 sand) :Deep groove pointing(B-143/12.31.3) |
| 25 | Structural steel work riveted,bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete:(B-98/9.2) |
| 26 | Extra for facing as per design & detailed specification CR 2nd Sort (B-70/6.4.2) |
| 27 | Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). (B-86/7.13) |
| 28 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). (B-86/7.12) |
| 29 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete.40mmthickwith20mmthicknominalsizeaggregate. (B-128/11.3.1) |
| 30 | Providing gola 75 x 75 mm in cement concrete 1:2:4 91 Cement : 2 corse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3(1 cement : 3 fine sand)as per standard design. (B-109/10.22) |
| 31 | Finishing with neat cement (punning). (B-140/12.7) |
| 32 | Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint (B-100/9.17) |
| 33 | Repair to stone masonary in cement sand mortar 1:6 with old & new stone. (B-151/13.12) |
| 34 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10 cm long embeddedin cement concrete bl,ocks 15x10x10 cm of 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) or with wooden plugs and screws or rawl plugs and screws or with fixing clups or with bolts and nuts as require including fixing or necessary butt hinges and screws and applying a priming coast of approval steel primer.(B-98/9.5) |
| 35 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure \"A\":Commercial Veneer both side (B-93/8.13.2.1) |
| 36 | Providing and fixing wood panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled and glazed shutter 25 mm to 40 mm thickShesham wood grade I (S-91/8.6.1.3) + Wire gauge 24 gauge 14 mesh of IS 1568-1970 marked 85 gauge of dia 0.56 mm (S-92/8.6.1.3+8.6.8) |
| 37 | Labour charges for repair to door/window without using any material such as applying randha (finishing)tightening of bolrts & screw etc.(B-152/13.24) |
| 38 | Renewing glass panes, with puty and nails wherever necessary: Float glass panes of rthickness 4 mm .(B-150.13.4.1) |
| 39 | Pointing on stone slab ceiling with cement mortar 1:2 (1 cement: 2 fine sand ): flush/Ruled pointing (B-143/12.32) |
| 40 | Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering.M15 grade Nominal Mix1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). (B-55/3.2.2) |
| 41 | Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on new work(B-146/12.46.1) |
| 42 | Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : One or more coats on Old work(B-146/12.46.2) |
| 43 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:Newwork(twoormorecoats)overandincludingscrappingandprimingcoatwithcement primer. (B-144/12.37.1) |
| 44 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:Newwork(twoormorecoats)overandincludingscrappingandprimingcoatwithcement primer. Same Colour (B-144/12.37.2) |
| 45 | Finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding:New work (Two or more coats applied @ 3.84 kg/10 sqm). (B-145/12.41.1) |
| 46 | Finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding:Old work (One or more coats). (B-145/12.41.2) |
| 47 | P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor:Size 580x440mm.(S-217/1.2.2) |
| 48 | P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall :Size 510 mm x 400 mm (S-221/1.36.2) |
| 49 | P&F looking mirror of PVC frame ofappd make ( Atul or eq ) size 500x400 mm(S-223/1.45.1 ) |
| 50 | Const of CC chamber 125 mm diafloor with stainless steel grating( S-255/ 3.39.4) |
| 51 | P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors:Exposed on wall15 mm dia nominal bore\"B\" Class (S-229/2.1.1) |
| 52 | 25mm dia nominal bore\"B\" Class (S-229/2.1.3) |
| 53 | P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc.15mm dia nominal bore\"B\" Class (S-230/2.2.1) |
| 54 | P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: Brass 400 gm,15mm nominal bore. (S-232/2.7.1) |
| 55 | C.P. brass bib cock 15 mm nominal bore (S-232/2.7.3) |
| 56 | P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection 15mm.Brass (IS : 8931 marked) (S-233/2.12.1) |
| 57 | P & F Ball Cock (IS :1703 Mark) with Rod& P.V.C. Ball complete :Brass wt.Not less than 400 gm, 20mm. (S-232/2.11.2) |
| 58 | P & F 15 mm. Dia Connection Pipe of approved quality/make:PVC pipe with C.P. Brass nuts upto length. 450 mm.(S-233/2.13.3) |
| 59 | P & F Flush Cock/Flush Valve (IS: 9758 Mark) for WC of approved quality make: Brass / Gun metel Half-turn wt. 1 kg. of approved quality/ make, 25 mm nominal bore (S-233/2.14.9) |
| 60 | P & F Full-way Value (IS: 778 Mark) or wheet valve of approved make. Gun - metal 25 mm nominal bore.(S-233/2.15.3) |
| 61 | P & F Full-way Value (IS: 778 Mark) or wheet valve of approved make.Gun - metal 15 mm nominal bore. (S-233/2.15.1) |
| 62 | P & F PVC Storege Tank (IS : 12701 marked indicating the BIS license No.), of approved make with cover, 25 mm dia 1 M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design:500 ltr. capacity (S-236/2.26.3) |
| 63 | P & F PVC Storege Tank (IS : 12701 marked indicating the BIS license No.), of approved make with cover, 25 mm dia 1 M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design:300 ltr. capacity (S-236/2.26.3) |
| 64 | P & F Square - month gully trap \"A\" grade (IS: marked) of approved make complete with C.I. grating, frame & Cover masonary chamber in C.M. 1:6, 100mm thick C.C. 1:5:10 base concrete, 40 mm thick C.C.M-15 grade coping, 12mm thick cement plaster in CM 1:3 complete as per approved design & type. Trap size 150 x 100 mm, RCC cover with frame, Internal Chamber size 300 x 300mm.(S-244/3.5.1) |
| 65 | Construction of manhole in all type of soil inner size 90x60 cm. thick masonary in CM 1:6, 10 Cm. thick cement concrete 1:5 10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring making channels, 80mm thick stone slab covering with 40 mm thick M-15 grade C.C. flooring, RCC cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50mtr. lead. Depth up to 0.5 M (S-250/3.19.1) |
| 66 | P&F Sand cast Floor Trap (Nahni) of (IS: 1729 mark) of approved quality/make with socket down of hinged grating including cutting and making good the floor size 100x100 mm (S-247/3.12.1) |
| 67 | P & F UPVC SWR. pipes grade \"B\" for sciland wast discharge system (IS :13592-1992 marked) of approved make75 mm dia (S-257/3.44.1) |
| 68 | P & F UPVC SWR. pipes grade \"B\" for sciland wast discharge system (IS :13592-1992 marked) of approved make110 mm dia (S-257/3.44.2) |
| 69 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /makeCoupler 110mm dia (S-257/3.45.1) |
| 70 | P & F UPVC SWR. pipes grade \"B\" for sciland wast discharge system (IS :13592-1992 marked) of approved make 110 mm dia bend (S-257/3.45.4 ) 87.5 degree |
| 71 | P & F UPVC SWR. pipes grade \"B\" for sciland wast discharge system (IS :13592-1992 marked) of approved makVent Cowel 110mm dia (S-259/3.45.30) |
| 72 | P & F UPVC SWR. pipes grade \"B\" for sciland wast discharge system (IS :13592-1992 marked) of approved make110 mm dia Tee with door( S-258/3.45.17) |
| 73 | P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete. Flat Back (small) size 456x355x265mm. (S-218/1.14.1) |
| 74 | Construction of soakage well in all type of soil 300mm thick dry masonry, top and bottom 300mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1:3, Ralthal, Kharanja, 40mm thick M-15 grade C.C. flooring, earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr. : Size 240 cm. dia outside & 240 Cm. Depth. (S-252/3.22.3) |
| 75 | Making connection to G I main to Distibution i/c all fitting upto 25 mm dia ( S-231/2.3.1) |
| 76 | P&F towel rail or ring of appd quality or make Cp brass towel rail with bracket 600X20 mm heavy duty. (S-223/ 1.47.4) |
| 77 | P & F Europeantype white glazed vitreous china 1st quality W.C. (IS : 2556 Mark) including cutting and making good the wall and floor Wall Mounting(S-217/1.6.1) |
| 78 | P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: PVC with PVCbend as per IS : 7231 . (S-219/1.20.2) |
| 79 | P & F water closet Seat Covers with brass hinges complete :\"-do- White. (S-218/1.7.2) |
| 80 | P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. (S-226/1.59) |
| 81 | S & F following sizes (dia.) of ISI marked virging material MMS (IS:9537 P-III)PVC conduit along with ISI marked (IS:3419-1988) accessoriesas required in recess including cutting the wall, covering conduitand making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with the BSR . 25 mm. (E-01/1.4.2) . |
| 82 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 K V grade (IS 694) of approved make in surface/recessed ISI marked MMS (IS:9537 P-III)virgin material PVC conduit & its ISI marked (IS:3419-1988) accessories , round tiles, 1.2 mm thick Hot Dipped Galvanized Modular box with earth terminal , Short point (Upto 3 AModular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder / 3 way connector , screws, making connections, testing etc. as required. For specification of copper conductor, Phenolic Laminated sheet\"s & Electrical / Wiring accessories refer Chapetr E-04, E-05 & E-07 for additional technical parameters of product / work refer Annexure \"A\" attached with BSR Short Point (up to 3 Mtr.) (E-01/1.1.1) |
| 83 | b) Medium point (Upto 6 Mtr.)(E-01/1.1.2) |
| 84 | c) Long point (Upto 10 Mtr.) (E-01/1.1.3) |
| 85 | Supplying & drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical works withISI marked (IS:694 ) and as per IS 8130:2013 of 1.1 KV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss, oxygen free for less chances of oxidization, insulation PVC typr A/C/D, flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part-5, in existing surface or recessed PVC/MS conduit/casing capping making connections with copper lugs of suitable size, Ferrules, testing etc. as required. OEM must have its own in house NABL lab set up for all testing facilities for wires. for additional technical parameters of product / work refer Annexure \"A\" attached with BSR 2X2.5 Sq.mm+1X1.5 Sq.mm (E-04/4.1.7) |
| 86 | (b) 2x4Sq.mm. + 1x2.5 Sq.mm. (E-04/4.1.14) |
| 87 | Wiring of 3 pin 5 Amp. light plug point with 1.5 sq mm nominal size FR PVC insulated unsheathedflexible copper conductor 1.1 KV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathedflexible copper earth conductor 1.1 K V grade (IS 694)in recessed IS marked MMS (IS:9537 P-III) PVC conduit & It\"s marked (IS:3419-1988) accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin A modular socket , Modular face plate with grade plate, screws , making connections, testing etc. as required.For specification of copper conductor, Phenolic Laminated sheet\"s & Electrical / Wiring accessories refer Chapetr E-04, E-05 & E-07 for additional technical parameters of product / work refer Annexure \"A\" attached with BSR oN bOARD.(E-01/1.3.1) |
| 88 | Suppling & Fixing of power plug point WITH NON MODULAR accessoriesas per PWD specification for electrical works with Galvanized box of 1.2 mm thick with earth terminal with suitable size Phenolic laminated sheet (IS:2036-1995) cover including cost of 16 amp. switch (IS:3854) and 3/6 pin 16 amp. socket outlet making connection, testing. etc. required. For specification of Wiring refer chapter E-07 related item & For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR (E-07/7.36) |
| 89 | P & F 240/415 V AC MCB with positive isolation of 10 KA breaking capacity (B/C/D tripping characteristic as per type of load and site requirement ) 4 KV impulse with stand voltage , ISI marked IS 8828(1996) / confirming to IEC 60898-1 2002, IEC 60947-2, low watt losses , trip free mechanisum , energy limiting of class 3 conductor line load reversibility , IP 20 contact protection and fitted in existing distrubution board/sheets, minium electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL/CPRI/ERDA accrediated lab type test reports & all as pre pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR (E-06/6.1.1.2) 6 A to 32 A rating |
| 90 | P & F 240/415 V isolator ISI marked IS:13947-III/ confirming to IEC 60947-3, suitable for AC22A utilization catergory, 4KV impulse withstand voltage, true contact indication, Red colour dolly/lever shallhave single mould covering over all poles for operation, two position, two position din rail mounting, minium phase termination capacity of 35 Sq.mm. IP 20 contact protection and fitted in existing distrubution board/sheets,including making connections, testing etc. as required. OEM shall have submit NABL/CPRI/ERDA accrediated lab type test reports & all as pre pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR (E-06/6.2.1.2) 63 A rating |
| 91 | SITC of Monoblock motor pump set IS marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC:60034-30:2008, & IS12615:2011. with stainless steel impellor , stainless steel shaft , Mechanical seal, Single/Three phase (240-440 V) permanent split capacitor type (PSC), fitted with thermal overload protection, including cost of hardware etc on existing plateform complete. Pump shall have following HP rating , phase , Head , minium Discharge respectively complete in all rescpect.OEM shall have submit NABL/CPRI/ERDA accrediated lab type test reports & all as pre pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 1.0 HP, 1-Q, (10-120) Mtr, (30-12) LPM (E-21/21.7.2) |
| 92 | Pipe earthing as per IS : 3043 -1987 with 3.0 Mtr. Long, 40 mm dia \"B\" class G.I. pipe IS: 1239 (part-1) 2004, Equivalent to BS :1387 with perforated holes of 12 mm dia, including all accessoreis like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size Top dia, 225 to 260 mm, Bottom Dia 300 to 350 mm and height 250 to 300 mm and embodying the pipe complete with alternate layers salt and coke/charcol, testing of earth resistance for value of 5 Ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurement book. All per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR (E-14/14.1) |
| 93 | S & Laying followint size earth wire/strip in horizontal of vertical run in ground/surface/recess including riveting,soldering,saddles,making connection with GI/Cu purity purity > 95% thimble etc. as required . All per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR (E-14/14.6.9) 10 SWG G.I. (Hot Dipped Wire) |
| 94 | P&F of energy efficient direct fit (Ratrofit) Poly carbonate /Glass housing SMD Mid power LED tube rod (with intergal driver & alumn. Heat sink) , on existing fixture.System lumen efficacy >_ 100 lm/Watt output, internal surge protection of 2.5 KV, THD< 20% , p.f. >_ 0.95, CRI> 80, lfe time of minium 35000 Burning Hours with 70% of initial Lumen maintaned till life ends, CCT 3000*K /4000*K /5700*K /6000*K /6500*K (As per ANSI Bin), maximum power consumption should not more than the specified ratting and fixture shall be of BIS standard and trade mark certificate (T.C.) Manufcatures word Mark/Name Engraved/Embossing/Screen printing on housing. OEM must have it\"s own in hose NABL lb steup for all testing facilities for LED fixtures. (LM79 & LM80) certificate/Report form OEM shall be submitted. All per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 1200 mm, Min. Lumens output 2000 im LED tube rod with glass housing ( E-17/17.2.3) |
| 95 | P&F ISI11037:1984 marked non modular socket size flush type 180 watt rotary minium 5 step fan regulator with CM/L No. printed and made out form Industrial grade polycarbonate or fire resitantABS material including making connection testing as required. All per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR ( E-07/7.21) |
| 96 | P & F of IP20 SMD Mid power LED batten type intergrated light fixture made from powder coated extruded aluminium housing with in built driver , System lumen efficancy >_ 110 lm/Watt output, internal surge protection of 2.5 KV, THD< 20% , p.f. >_ 0.95, CRI> 80, lfe time of minium 35000 Burning Hours with 70% of initial Lumen maintaned till life ends, CCT 3000*K /4000*K /5700*K /6000*K /6500*K (As per ANSI Bin), maximum power consumption should not more than the specified ratting and fixture shall be of BIS standard and trade mark certificate (T.C.) Manufcatures word Mark/Name Engraved/Embossing/Screen printing on housing. OEM must have it\"s own in hose NABL lb steup for all testing facilities for LED fixtures. (LM79 & LM80) certificate/Report form OEM shall be submitted. All per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 570 mm (+/-10%) batten with min. Lumen output 1000 lm ( E-17/17.1.2) |
| 97 | P & F 1.2 mm thick G.I./M.S. sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 1.2 mm thick M.S. sheet boxes 250mmX300mmX75mm (E-05/5.1.1.11) |
| 98 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR Metal door (single phase) IK-09 and IP-43 with Metal end box 12 Way (12+2) (6.10.1.4) |