| 1 | ELECTRICITY |
| 2 | Wiring for light point / exhaust fan point / call bell point with 1.5 sq mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular type switch phenolic laminated sheet suitable size M.S. / PVC box etc as required. Group C |
| 3 | Wiring for twin control p;int with 1.5 sq mm FR PVC insulated copper conductor single core cable in surfce / recessed medium class PVC conduit 2 way modular type switch phenolic laminated sheet suitable size M.S./ PVC box etc. as required. |
| 4 | Wiring for light/ power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 5 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. |
| 6 | 2 x 2.5 sq.mm + 1 x 2.5 sq. mm earth wire |
| 7 | 2 x 6 sq.mm + 1 x 6 sq.mm earth wire. |
| 8 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular socket oulet and 15/16 amps modular switch, connecvtion etc. as required |
| 9 | Supplying and fixing following modular type switch/socket on the existing switch box / cover including connections etc.as required |
| 10 | 5/6 amps switch. |
| 11 | 3 pin, 5/6 amps socket outlet. |
| 12 | Supplying and fixing following size/ modules, GI box along with modular base and cover plate for modular switches in recess etc as required. |
| 13 | 4 Module (125mmX75mm) |
| 14 | 8 Module (125mmX125mm) |
| 15 | suppling and fixing fixing 3/2 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 16 | Supplying and fixing batten / angle holder including connection etc as required. |
| 17 | Supplying and fixing following rating,240/415 volts \"C\" curve, miniature circuit breaker suitable for loads of single pole in the existing MCB DB complete with connection, and commissioning etc. as required. |
| 18 | 40 amp, Single pole and neutral |
| 19 | 6/32 Single pole |
| 20 | Supplying and fixing following way,single pole & neutral, sheet steel, MCB distribution board,240 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted, including earthing etc as required. (But without MCB/RCCB/Isolator) |
| 21 | 2 + 2 way, single door, |
| 22 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required. |
| 23 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble as required. |
| 24 | Supply of Fan Tube etc.L.S |
| 25 | ADD 5.36% For G.S.T. |
| 26 | DRINKING WATER |
| 27 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. |
| 28 | 32 mm nominal outer dia Pipes |
| 29 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 30 | 32 mm nominal outer dia Pipes |
| 31 | 20 mm nominal outer dia Pipes |
| 32 | Providing and fixing brass bib cock of approved quality : |
| 33 | 20 mm nominal bore |
| 34 | Providing and fixing brass stop cock of approved quality : |
| 35 | 20 mm nominal bore |
| 36 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 37 | Earth work in excavation in foundation trenches (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 38 | Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete. |
| 39 | Providing designation 100 A one brick flat soling joints filled with localsand including cost of watering, taxes, royality all complete as per building specification and direction of E/l, |
| 40 | Providing PCC 1:3:6 (1 Cement; 3 coarse sand :6 graded stone aggregate 40 mm nominal size) in foundation excluding the cost of centring and shuttering-all work upto plinth level |
| 41 | ProvidingBrick workwith bricks ofclass designation 100A inCement mortar 1:4 (1 cement: 4 coarse sand ) in foundations and plinth . |
| 42 | Providing 125 mm thickbrick masonry with bricks of class designation 100A in wall in Cement mortar 1:4 (1 cement: 4 coarse sand). |
| 43 | Providing Reinforced cement concrete work in 1:1.5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20mm nominal size inCover Slab excluding cost of centring, shuttering, finishing and reinforcement. |
| 44 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. |
| 45 | Providing12mmcementplasterof mix 1:3 (1 cement: 3coarsesand)with5 % Water proofing materials andneat cement punning |
| 46 | Providing 12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand) in walls |
| 47 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy , bottle green , black of any size as approved by Engineer-in-charge in skirting , risers of steps and dados over 12 mm thick bed of cement Motar 1:3(1 cement: 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 48 | Chequerred precast cement concrete tiles 22 mm thick with marble chips of size 6 mm in plateform jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. Complete on 20 mm thick bed of cement mortar 1:4 (1 cement:4 coarse sand) |
| 49 | Bricks |
| 50 | Local Sand |
| 51 | Sand |
| 52 | Stone |
| 53 | Cement |
| 54 | Steel |
| 55 | Bricks |
| 56 | Cement |
| 57 | Adding 15 % C.P |
| 58 | Adding 1 % Labour Cess |
| 59 | ADD GST 5.36% |
| 60 | NEW TOILET |
| 61 | Un Skilled labour for site cleaning |
| 62 | Making 25 cm (10\") dia bore up to 4 mtr depth below ground with hand auger of approved quality in ordinary soi! (vide classification of soil item A ) true to plumb and without eccentri city in any stage of operation and disposal of the excavated earth up to 50 mtr , Lead in eluding all lifts , all complete as per approved disign and direction of E/l Details of cost for 4 piles of 4 m= 16 mtrs depth ) |
| 63 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring,shuttering,finishing and reinforcement-All work puto plinth level 1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20 mm nominal size) |
| 64 | Earth work in excavation in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. all kind of soil. |
| 65 | Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete |
| 66 | Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/. |
| 67 | Providing and laying in position cement concrete of specified gradeexluding the cost of centring and shuttering-all work upto plinth level. 1.4.8 (1 Cement :4 coarse sand :8 graded stone agregate 40 mmnominal size) |
| 68 | Providing and laying in position specified grade of reinforced cementconcrete 1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20 mm nominal size) excluding the cost of centring, shuttering,finishing and reinforcement-All work puto plinth level etc all complete job as per building specification & direction of E/I. |
| 69 | Brick work with bricks of class designation 100A in foundations andplinth in : Cement mortar 1:4 |
| 70 | Half brick masonry with bricks of class designation 100A inin superstructure above pinth level upto floor V level for every four floors or part there of : Cement mortar 1:4 (1 cement: 4 coarse send |
| 71 | supply fixing and fitting of G.I. pipes 40 mm dia in railing all work completed as per direction of E/I |
| 72 | Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4(1cement:2:2 coarse sand :4 graded stone aggregate 20mm nominal size) |
| 73 | Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete ( from G.L to Plinth level) |
| 74 | Reinforced cement concrete work in lintelupto floor five level excluding cost of centring, shuttering, finishin and reinforcement.1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20mm nominal size) etc all complete job as per building specification & direction of E/I. |
| 75 | Reinforced cement concrete work in column upto floor five level excluding cost of centring, shuttering, finishin and reinforcement.1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20mm nominal size) etc all complete job as per building specification & direction of E/I. |
| 76 | 6 mm cement plaster on top of wall at roof level of mix 1:4 with punning and White washing with lime to give an ever shade New work (three or more coats) |
| 77 | Reinforced cement concrete work in roof 4 \" thickupto floor five level excluding cost of centring, shuttering, finishin and reinforcement.1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20mm nominal size) etc all complete job as per building specification & direction of E/I. |
| 78 | Cement plaster in course sand 12 mm cement plaster of mix:1:3 (1 cement:3 coarse sand) and Extra for providing and mixing water proofing material in proportionrecommended by the manufacturers: |
| 79 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. |
| 80 | Providing and fixing 1 mm thick M.S.sheet sliding - shutters with frame and diagonal braces of 40x40x6 mm angle iron,3 mm M.S. gusset plates at the junction and corners, 25 mm dia pulley, 40x40x6 mm angle and T-iron guide at the top bottem respectively including applying a priming coat of approved steel primer. |
| 81 | 12 mm cement plaster of mix:1:6(1 cement: 6 coarse sand) |
| 82 | 12 mm cement plaster of mix:1:6(1 cement: 6 coarse sand) with punning |
| 83 | 6 mm cement plaster to r to ceiling of mix 1:4 (1 cement: 4 coarse sand) |
| 84 | Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l, |
| 85 | Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level. 1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size) |
| 86 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622(thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete |
| 87 | Chequerred precast cement concrete tiles 22 mm thick with marbie chips of size 6 mm in footpath & coutyard jointed with neat cement slurry mixed with pigment to match thehade of tiles including rubbing (Dark shade using ordinary cement) and cleaning tec. Complete on 20 mm thick bed of cement mortar 1:4(1 cement:4 coarse sand) |
| 88 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy , bottle green , black of any size as approved by Engineer-in-charge in skirting , risers of steps and dados over 12 mm thick bed of cement Motar 1:3(1 cement: 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 89 | White washing with lime to give an ever shade New work (three or more coats) |
| 90 | Applying one coat of cement primer of approved brand and finishing walls with water proofing cement paint of approved brand and |
| 91 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade |
| 92 | Centring and shuttering including strutting propping etc. and removal of form for columns pillars piers abutments posts and struts. |
| 93 | Centring and shuttering including strutting propping etc. and removal of form for columns pillars piers abutments posts and struts. |
| 94 | Sanitary Fitting |
| 95 | P.V.C Pipe (4\" dia ) |
| 96 | Pan |
| 97 | P-Trap 4\" dia |
| 98 | Bend 4\" dia |
| 99 | Vitreous china angle back wash basin 600x480 mm |
| 100 | P.V.C. automatic flushing cistern 5 lts capacity |
| 101 | Diffrence rate cost of labour/ Mason |
| 102 | Labour |
| 103 | Mason |
| 104 | add labour cess |
| 105 | Carriage cost of material |
| 106 | Brick |
| 107 | Local Sand |
| 108 | Sand |
| 109 | Stone chips |
| 110 | Steel |
| 111 | Cement |
| 112 | Diffrence cost of materials |
| 113 | Bricks |
| 114 | Cement |
| 115 | Seignorage FEES |
| 116 | Local Sand |
| 117 | Sand |
| 118 | Stone chips |
| 119 | Add For water facility L.S |
| 120 | Septic Tank |
| 121 | Un Skilled labour for site cleaning |
| 122 | Earth work in excavation in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. all kind of soil. |
| 123 | Extra for every additional lift of 1.5 m or part thereof in : Ali kinds of soil. |
| 124 | Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete |
| 125 | Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l, |
| 126 | Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level. 1:3:6 (1 Cement; 3 coarse sand :6 graded stone aggregate 40 mm nominal size) |
| 127 | Brick work with bricks of class designation 100A in foundations andplinth in : Cement mortar 1:4 |
| 128 | Reinforced cement concrete work inbeamupto floor five level excluding cost of centring, shuttering, finishin and reinforcement.1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20mm nominal size) etc all complete job as per building specification & direction of E/I. |
| 129 | Half brick masonry with bricks of class designation 100A inin superstructure above pinth level upto floor V level for every four floors or part there of : Cement mortar 1:4 (1 cement: 4 coarse send |
| 130 | Reinforced cement concrete work in slabupto floor five level excluding cost of centring, shuttering, finishin and reinforcement.1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20mm nominal size) etc all complete job as per building specification & direction of E/I. |
| 131 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. |
| 132 | Cement plaster in course sand 12 mm cement plaster of mix:1:3 (1 cement:3 coarse sand) with punningand Extra for providing and mixing water proofing material in proportion recommended by the manufacturers: |
| 133 | Centring and shuttering including strutting propping etc. and removal of form for columns pillars piers abutments posts and struts. |
| 134 | Diffrence rate cost of labour/ Mason |
| 135 | Labour |
| 136 | Mason |
| 137 | add labour cess |
| 138 | Carriage cost of material |
| 139 | Brick |
| 140 | Local Sand |
| 141 | Sand |
| 142 | Stone chips |
| 143 | Steel |
| 144 | Cement |
| 145 | Diffrence cost of materials |
| 146 | Bricks |
| 147 | Cement |
| 148 | Seignorage FEES:- |
| 149 | Local Sand |
| 150 | Sand |
| 151 | Stone chips |
| 152 | ADD 5.36 % FORGST |
| 153 | ADDITIONAL CLASS ROOM |
| 154 | Un Skilled labour for site cleaning |
| 155 | Earth work in excavation in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. all kind of soil. |
| 156 | Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete |
| 157 | Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/. |
| 158 | Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level. 1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size) |
| 159 | Providing and laying in position specified grade of reinforced cementconcrete 1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20 mm nominal size) excluding the cost of centring, shuttering,finishing and reinforcement-All work puto plinth level etc all complete job as per building specification & direction of E/I. |
| 160 | Brick work with bricks of class designation 100A in foundations andplinth in : Cement mortar 1:4 |
| 161 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring,shuttering,finishing and reinforcement-All work puto plinth level of 1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20 mm nominal size) |
| 162 | Brick work with bricks of class designation 100A in foundations and plinth in : Cement mortar 1 .:4 (1 cement: 4 coarse sand ) |
| 163 | Half brick masonry with bricks of class designation 100A inin superstructure above pinth level upto floor V level for every four floors or part there of : Cement mortar 1:4 (1 cement: 4 coarse send |
| 164 | Reinforced cement concrete work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts, etc. upt floor five level excluding cost of centring, shuttering, finishin and reinforcement.1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20mm nominal size) etc all complete job as per building specification & direction of E/I. |
| 165 | Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4(1cement:2:2 coarse sand :4 graded stone aggregate 20mm nominal size) |
| 166 | Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete |
| 167 | Reinforced cement concrete work in lintel etc. upt floor five level excluding cost of centring, shuttering, finishin and reinforcement.1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20mm nominal size) etc all complete job as per building specification & direction of E/I. |
| 168 | Reinforced cement concrete work in seal band etc. upt floor five level excluding cost of centring, shuttering, finishin and reinforcement.1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20mm nominal size) etc all complete job as per building specification & direction of E/I. |
| 169 | Brick work with bricks of class designation 100A in Superstructure in : Cement mortar 1:4 |
| 170 | On roof level providing 6 mm cement plaster 1:4(1 cement : 4 coarse sand ) , cement punning & three coat Lime painting work |
| 171 | Reinforced cement concrete work in chajjaupto floor five level excluding cost of centring, shuttering, finishin and reinforcement.1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20mm nominal size) etc all complete job as per building specification & direction of E/I. |
| 172 | Reinforced cement concrete work in rackupto floor five level excluding cost of centring, shuttering, finishin and reinforcement.1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20mm nominal size) etc all complete job as per building specification & direction of E/I. |
| 173 | Reinforced cement concrete work in roof beamupto floor five level excluding cost of centring, shuttering, finishin and reinforcement.1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20mm nominal size) etc all complete job as per building specification & direction of E/I. |
| 174 | Reinforced cement concrete work in roof 5 \" thickupto floor five level excluding cost of centring, shuttering, finishin and reinforcement.1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20mm nominal size) etc all complete job as per building specification & direction of E/I. |
| 175 | Providing and fixing M.S.fan clamp type I or II of 16 mm dia.M.S. bar bent to shape with hooked ends in R.C.C slabs during laying including painting the exposed portion of loop,all as per standard design complete. |
| 176 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. |
| 177 | Providing and fixing unplasticised -PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar(1:4) 1 cement: 4corsa sand and making good the wall etc complete |
| 178 | Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3mm MS gusset plates at the junction and corners.all necessary fittings completejncluding applying a priming coat of approved steel primer. Using M.S. angle 40x40x6 mm for diagonal braces |
| 179 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete Fixed to steel windows by welding |
| 180 | Providing blackboard 20 mm cement plaster of mix 1:4 ( 1 cement : 4 coarse sand ) with cement punning |
| 181 | 12 mm cement plaster of mix 1:6 (1 cement : 4 coarse sand ) |
| 182 | 12 mm cement plaster of mix 1:6 (1 cement : 4 coarse sand )and cement punning work |
| 183 | 6 mm cement plaster to ceiling of mix 1:4 (1 cement : 4 coarse sand ) |
| 184 | Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l, |
| 185 | Kota stone slab flooring over 20 mm (average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete . Base with 1:1:1 (1 lime : 1 surkhi: 1 coarse sand ) / 1:4 (1 cement: 4 coarse sand : 20 to 25 mm thick - |
| 186 | Pro PCC (1:2:4) Work below kota stone floor |
| 187 | Pro wooden beat for fixing chart paper |
| 188 | White washing with lime to give an ever shade New work (three or more coats) |
| 189 | Applying one coat of cement primer of approved brand and finishing walls with water proofing cement paint of approved brand and |
| 190 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade |
| 191 | Centring and shuttering including strutting propping etc. and removal of form for columns pillars piers abutments posts and struts. |
| 192 | Centring and shuttering including strutting propping etc. and removal of form for columns pillars piers abutments posts and struts. |
| 193 | Centring and shuttering including strutting propping etc. and removal of form for columns pillars piers abutments posts and struts. |
| 194 | Diffrence rate cost of labour/ Mason |
| 195 | Labour |
| 196 | Mason |
| 197 | add labour cess |
| 198 | Carriage cost of material |
| 199 | Brick |
| 200 | Local Sand |
| 201 | Sand |
| 202 | Stone chips |
| 203 | Steel |
| 204 | Cement |
| 205 | Diffrence cost of materials |
| 206 | Bricks |
| 207 | Cement |
| 208 | Seignorage FEES |
| 209 | Local Sand |
| 210 | Sand |
| 211 | Stone chips |
| 212 | Wiring for light point / exhaust fan point / call bell point with 1.5 sq mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular type switch phenolic laminated sheet suitable size M.S. / PVC box etc as required. Group C |
| 213 | Wiring for twin control p;int with 1.5 sq mm FR PVC insulated copper conductor single core cable in surfce / recessed medium class PVC conduit 2 way modular type switch phenolic laminated sheet suitable size M.S./ PVC box etc. as required. |
| 214 | Wiring for light/ power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 215 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. |
| 216 | 2 x 2.5 sq.mm + 1 x 2.5 sq. mm earth wire |
| 217 | 2 x 6 sq.mm + 1 x 6 sq.mm earth wire. |
| 218 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular socket oulet and 15/16 amps modular switch, connecvtion etc. as required |
| 219 | Supplying and fixing following modular type switch/socket on the existing switch box / cover including connections etc.as required |
| 220 | 5/6 amps switch. |
| 221 | 3 pin, 5/6 amps socket outlet. |
| 222 | Supplying and fixing following size/ modules, GI box along with modular base and cover plate for modular switches in recess etc as required. |
| 223 | 4 Module (125mmX75mm) |
| 224 | 8 Module (125mmX125mm) |
| 225 | suppling and fixing fixing 3/2 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 226 | Supplying and fixing batten / angle holder including connection etc as required. |
| 227 | Supplying and fixing following rating,240/415 volts \"C\" curve, miniature circuit breaker suitable for loads of single pole in the existing MCB DB complete with connection, and commissioning etc. as required. |
| 228 | 40 amp, Single pole and neutral |
| 229 | 6/32 Single pole |
| 230 | Supplying and fixing following way,single pole & neutral, sheet steel, MCB distribution board,240 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted, including earthing etc as required. (But without MCB/RCCB/Isolator) |
| 231 | 2 + 2 way, single door, |
| 232 | Add for GST 5.36 % |