| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-01-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 20-01-2025 |
| Sl. No. | Item Description |
| 1 | Dismantling floor hearth or wall tiling including cementmortar bedding (but not backing) complete all as specified and directed |
| 2 | Glazed coloured ceramic tiles in vertical surface 350mm x 250mm x 7mm /450mm x 350 x7mm thick, set and jointed in neat cement slurry over 10mm thick thick rendering in cement mortar 1:4, for receving the tiles complete all as specified and directed. |
| 3 | Non skid ceramic coloured tiles7 to 8 mm thick area of each tile exc 0.18 sqm but not exceeding 0.38 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6, for floor finishes complete all as specified and directed. |
| 4 | Coloured vitrified ceramic tiles, light shade,8-10mm thick (square ) , area of each tiles n.exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over15mm thick screed bed in cement mortar 1:6,including dismantling olf tiles and removal of debries complete all as specified and directed. |
| 5 | All as per serial item No 4 hereinbefore but as in skirting/ daddo including and over 10mm rendreing in cement mortar 1:4 complete all as specified and as directed. |
| 6 | Demolition of cement concrete (un-reinforced) in ground floor and paving n.exc 15cm thickness (below or above GL) as in plinth protection/ path/ Hard standing/ floor etc. etc complete removal of debris outside MD land complete all as speicified and directed. |
| 7 | Plain cement mortar 1:3:6 (type C-1 using 20mm graded aggregate), 75mm thick as in Plinth protection , finishing cement concrete even and smooth without using extra cement,completed all as specified and directed. |
| 8 | Demolition of brick work built in cement mortar including all quoins, arches, pillar etccomplete all as specified and directed. |
| 9 | Brick work with subclass \"B\" brick old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:4 complete all as specified & directed. |
| 10 | All as per serial item No. 9 herein before but except bricks (using old serviceable bricks obtained from demolition of brick work can be reused) |
| 11 | Brick work with sub class\"B\" bricks, straight or curved on plan to any radius on half brick thick wallin cement mortar 1:4 complete all as specified & directed. |
| 12 | Taking down cement plaster of any descruption on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc including removing all debrish from defence ladn complete all as specifiedand as directed. |
| 13 | 15mm thick rendering in cement mortar1:6 on brick walls or concrete surface and finished fair and even without using extra cementcomplete all as specified & directed. |
| 14 | 15mm thick rendering in cement mortar1:4 on brick walls or concrete surface and finished fair and even without using extra cementcomplete all as specified & directed. |
| 15 | Rendering 15mm thick in Cement and Sand mortar 1:4 overfair faces of brick / concrete ,finished even and smooth without using extra cement, inclunding using water proofing compound complete all as specified.Note : WPC shall be measured and paid separately. |
| 16 | 10mm thick rendering in cement and sand mortar 1:3 over brick work or conrete surfaces finished even and smooth without using extra cement, as in ceiling, chajjas, facias, at any position, complete all as specifed and directed |
| 17 | Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. |
| 18 | Two or more coats on new plastered surfaces of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paintof required shade (Company Depot Tinted) with silicon additives @ 1.43 liter/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. Note Necessary scaffolding, safety precaution and other arrangement complete all as specified and directed. |
| 19 | Dismantling of wall and ceiling board (fibre, pulp insulation etc) any thickness & at any height complete all as specified and directed |
| 20 | Powder coated GI frame work grid 605 x 605mm for ceiling comprising of GI perimeterchannel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to enter/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre centre and hangers 3mm dia GI (up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 600mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and directed. |
| 21 | 4mm thick Nonasbestos fibre cement building boardsfixed or laid/ inserted to timber/GI/Aluminium framework with screws fix in ceiling flat or sloping complete all as specified. |
| 22 | PVC sheet fillet 35mm wide, 5mm thick for wall paneling inclusive of fixing in to wall to make PVC frame complete all as specified and directed. |
| 23 | Solid PVC wall lining consisting of 5mm thick wooden grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specification and complete all as specified and directed. |
| 24 | Taking down chowkhats or frame n.exc 1.5 Sqm with shutter without taking off shutter and removing from site complete all as specified & directed. |
| 25 | Taking down chowkhats or frame exc 1.5 Sqm but n.exc 4 Sqm with shutter without taking off shutters and removing from site complete all as specified & directed. |
| 26 | Taking down shutter of any description exc 1 Sqm but n.exc 2 Sqm each & removing from site complete all as specified & directed. |
| 27 | Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). |
| 28 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of EngineerIn- Charge |
| 29 | Factory made pressed steel frames of profile width 125mm x 60mm fabricated from 1.25 mm thick sheet, for doors with one or more rebate including necessary fixing lugs, hinges, lock strike plate, etc. & one shop coat of primer, and back filled with PCC 1:3:6 type C-1 complete all as specified. |
| 30 | Flush shutters 35mm thick factory made solid core construction with block board core and ply wood face panels commercials type on both side complete all as specified & directed. |
| 31 | 150mm aluminium anodized barrel tower bolts of extruded section complete all as specified and directed |
| 32 | 250 mm longAluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed,complete all as specified and directed. |
| 33 | Butt hinges 100mm long, of extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 , all as directed. |
| 34 | 150mm long aluminum handle (ISI Marked)cast type anodized , complete all as specified |
| 35 | 100mm long aluminum handle (ISI Marked)cast type anodized , complete all as specified |
| 36 | Powder coated aluminium sections as inframes/ shutter of doors/windows/ventilators /three track sliding window including necessary joinging cleats, glazing clips, rubber neoprene beading, handlea, hinges screws etc.complete all as specified and directed.Note : (i) Thickness of power coating shall not be less than 30 micron.(ii) Weight of aluminum section only shall be measuerd and paid.(iii) Aluminum doors/windows /ventilators to be fixed to jambs with chromium plated screws .(iv) The rate shall be inclusive of neoprene beadings, handles, hinges, screws etc. weight of fittings/fixtures will not be measured for ariving the weight of aluminium section.(v) Design shall be approved from Engineer-in Charge |
| 37 | 4.80mm thick ordinary quality tinted glass,fixed to aluminum frame workin panels exc 0.5 Sqm in each pane, complete all as specified & directed. |
| 38 | 3mm thick sheet glass ordinary quality any size and in any type of frame and glazing with oil putty in square n.exc 0.5 Sqm in each panes, including hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. |
| 39 | 3mm thick sheet glass ordinary quality any size and in any type of frame and glazing with oil putty in square n.exc 0.5 Sqm in each panes complete all as specified and directed. |
| 40 | Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm including fixed with stainless steel wire staple fixed as in repaircomplete all as specified & directed. |
| 41 | Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm including fixed with stainless steel wire staplescomplete all as specified & directed. |
| 42 | 150mm mild steelordinary rat tail rod pattern spring including roller and roller plate fixes as in repair complete all as specified and directed. |
| 43 | preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 44 | Two coats of synthetic enameled paint on steel and iron surfaces over one coat of red oxide primer on surfaces over 10 cm width or girth including preparation of new surfaces complete all as specified & directed. |
| 45 | Two coats of synthetic enameled paint on steel and iron surfacesover 10 cm width or girth including preparation of new surfaces complete all as specified & directed. |
| 46 | Floor door stopper of aluminum alloy body and tongue, anodized with hard drawn steel spring, fixed in floor (140mm size),fixed as in repair complete all as specified and directed. |
| 47 | 15mm bore pillar tap, fancy type,cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, fixed as in repair complete all as specified and directed. |
| 48 | Steel water tubes, 15mm dia bore, medium grade, galvanized, with and including all fittings and fixed complete to walls ceiling or laid in floors, Taking up down steel tuibing and connections 15mm bore complete all as specified and directed. |
| 49 | Steel water tubes, 20mm dia bore, medium grade, galvanized, with and including all fittings and fixed complete to walls ceiling or laid in floors, Taking up down steel tuibing and connections 15mm bore complete all as specified and directed. |
| 50 | Cuttingchases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of inserting sheets, landings, steps, cills, sunshades, shelves, lintels, etc,; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth complete all as specified and as directed. |
| 51 | Vitreous china, wash down water closet pan, white, Pedestal pattern WC with ‘P’ or ‘S’ trap, with all fittings and connection, fixed as in repairs complete all as specified and directed. |
| 52 | PVC valve less syphonic action type flushing cistern low level white with PVC in let ball valve, float and handle, 10 ltrs capacity and connection to pipes including 32mm dia PVC bendfor squat/ pedastal pattern etc fixed in repair complete all as specified & directed. |
| 53 | Health faucet (ABS body) mild steel chromiu plated for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook incuding making connections and fixed in position, fixed as in repair complete all as specified and directed. |
| 54 | Wash hand basin, vitreous china, counter top of size 600 x400x 185mm, white , ofsize560X410mm, including, ,CP pillar tap, CP waste coupling, angle brackets and PVC waste pipe,including cutting and pinning in ends fixed as in repair complete all as specified and directed. |
| 55 | Beveled edged looking mirror of size 600mmx450mm of selected quality, glass 6mm thick, mounted on 6mm thick comercial plywood and fixed to wooden plugs with choumium plated brass screws and cup washer complete, all as specifiedand directed. |
| 56 | Harrison rails 25 mm size, mild steel, chromium plated with fixing brackets, stops, rollers etc. for curtain rod inclulding taking doen defective bracket as in repair all as specified and as directed. |
| 57 | Brass, chromium plated, tubular towel rail 20 mm dia. ‘D’ type, 60 cm long between flanges including brackets,fixed as in repaircomplete all as specified and directed. |
| 58 | Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard and railing 60cm long, fixed as in repaircomplete all as specified and directed. |
| 59 | Kitchen sink with drainage board made out of stainless steel sheet 1.0mm thick with plug, washers and wastes, overall size 915 x 460mm, bowl size 410x330x160mm incl fixing cantilever brackets and connection to union, pipe, fixed as in repair complete all as specified and directed. |
| 60 | 15mm bore angle valves, cast copper alloy, fancy type chromium plated, screwed pressure, with crutch of butterfly handle, screwed both ends for iron pipe for unions, fixed as in repair, complete all as specified and directed. |
| 61 | Stop valves , cast copper alloy screwed pressure, with crutch or butterfly handle,screwed both ends for iron pipes for unions and fixed 15mm bore fixed as in repair complete all as specified and directed. |
| 62 | Bib taps, cast copper alloy, fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed as in repair complete all as specified and directed. |
| 63 | Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0,fixed as in repair all as specified and directed. |
| 64 | PVC(SWR) rain water pipe, 110mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mmincluding nuts bolts etc, fixed as in repair complete all as specified and directed. |
| 65 | 110mm bore PVC (SWR) bends any radius, fixed as in repair complete all as specified and directed |
| 66 | PVC(SWR) rain water pipe, 75mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mmincluding nuts bolts etc, fixed as in repair complete all as specified and directed. |
| 67 | 75mm bore PVC (SWR) bends any radius, fixed as in repair complete all as specified and directed |
| 68 | PVC (SWR) floor traps 75mm dia with grating including jointing to waste pipe with run led jointed and setting/fixed in cement concrete type B-1 (1:2:4), fixed as in repaircomplete all as specified and directed. |
| 69 | PVC (SWR) multi floor traps 75mm dia with grating including jointing to waste pipe with run led jointed and setting/fixed in cement concrete type B-1 (1:2:4) fixed as in repair complete all as specified and directed. |
| 70 | Preparation of old decorated surfaces of walls and applying one coat of oil bound distemper of approved tint, complete all as specified and directed |
| 71 | Complete removal of existing treatment by using of wire brush /mechanical grinder including washing rubbing down and stopping of distempered or painted surface and applying wall care putty 1mm thick over and including a coat of wall primer, smoothening the surfaces with sand papers etc. and applying two coats of oil bound distemper on wall surfacecomplete all as specified and directed. |
| 72 | Preparation of old decorated surfaces of ceiling and applying one coat of oil bound distemper of approved tint, complete all as specified and directed |
| 73 | Preparation of old surfacs and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed. |
| 74 | Preparation of old wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 75 | One coats of synthetic enameled paint on old steel and iron surfaces over 10 cm width or girth including preparation of old surfaces complete all as specified & directed. |
| 76 | Preparation of old plastered surfaces of walls and applying two coats of cement base paint, complete all as specified and directed. |
| 77 | Preparation of new plastered surfaces of walls and applying two coats of cement base paint (any colour) including all necessary scaffolding and safety arrangements, complete all as specified and directed. |
| 78 | Demolition of stone slabs of any description in floors laid, bedded and pointed in any mortar complete all as specified and directed |
| 79 | 18-20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and likein cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade ofgranite 15mm thick screed in cement mortar 1:6 complete all as specified and directed. |
| 80 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations |
| 81 | 500 Litres capacity Rotational moulded polythene water storage tanks (cylindrical vertical with closed top) double layeredhoisted and fixed in position including PTMT ball valve 20mm bore & PTMT tank nipple, etc, fixed as in repairs, complete all as specified and directed. |
| 82 | Cleaning and removing all scale and dirt etc from overhead water storage tanks of capacity exc 500 but n.exc 1000 litres and from mouths of circulating pipes etc complete all as specified and directed. |
| 83 | PVC connections 15mm size with PTMT nuts of length 450mm, fixed as in repair all as specified and directed. |
| 84 | Demolition of textile coverings including frames (if any) and cover fillets (measured flat and not girthed) complete all as specified and directed. |
| 85 | Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 86 | Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 87 | Dismantling timber scantling exc 40 Sqcm in section in any position unframed work & removing from site complete all as specified and directed. |
| 88 | Rolled sections as in main and cross beams, hip and jack rafters,purlins where connectedto common rafters and running rails and guidesforsliding doors, fixedwithangle cleats or other connecting plates, conforming to Fe-290 Gde E165, all as specified and directed. |
| 89 | Excavation in post holes (or similar hole) each in hard and dense soil n.exc 0.50 cu m getting out and removing surplus spoil at a distance not exc 50 metre and making good surfaces complete all as specified and directed. |
| 90 | Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed. |
| 91 | 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base etc, finished even and rough complete all as specified and directed. |
| 92 | Surface dressingin soft /loose soil n.xec 15cn deep trimming of natural ground (removing vegetation/ shrubs/brushwood) undergrowth and carrying away rubbish to a distance of 50 metre complete all as specified and directed. |
| 93 | Plain cement concrete type B-0, 1:2:4 using (12.5 mm graded crushed stone aggregate) as in filling post holes, bed blocks roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including the use of forms or moulds with plain faces complete all as specified and directed. |
| 94 | 0.63mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 fixed with self tapping screws etc complete all as specified & directed by Engineer-in-charge. |
| 95 | Factory made, precast concrete interlocking paver block any shape and size withgrey cement and pigment, including 25mm sand cushioningconforming to IS 15658-2006, of 60mm thickness, M-35 Grade completeall as specified and directed. |
| 96 | PVC(SWR) rain water pipe, 110mm bore, single socketed in any length with rubber ring joints, laid in trenches, fixed as in repair complete all as specified and directed. |
| 97 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressingof sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil compelte all as specified and directed. |
| 98 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft and loose soil all as specified & directed by Engineer-in-Charge. |
| 99 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc.25cm thick each layer of soil all as specified. |
| 100 | Removal excavated soil to a distance not exceeding 250 m and depositingwhere directed at a level not exceeding 1.5 mabove the starting point complete all as specified & directed. |
| 101 | PCC (1:3:6) type C-2 using 20 mm graded stone aggregate as in surface channels, benching and drains complete all as specified and directed. |
| 102 | Flush pointing to brick walls in cement mortar 1:4 complete all as specified & directed. |
| 103 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified & directed by Engineer-in-charge. |
| 104 | Al as per serial item 103 hereinbefore but each 25mm girth or part thereof over 30cmm complete all as specified and directed. |
| 105 | Dismantling fencing wire mesh any type complete all as specified and directed |
| 106 | Dismantling of posts or struts of RCC/wood/steel any section incl taking out embedded portion and making good disturbed portion, (posts embedded in concrete or in hard core) complete all as specified and directed |
| 107 | Mild steel work as in iron post / posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-410-W (Gde.E-250)quality-A or Fe 290 (Gde -E-165) complete all as specified and directed. |
| 108 | Galvanized, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including, securing or tying at crossings with and provision of galvanized mild steel wire, staples or steel pins, etc. as directed(each line of wire to be measured) fixed as in repair complete all as specified and directed. |
| 109 | Steel work in tubular trusses and tubular posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 , complete all as specified & directed by Engineer-in-Charge. |
| 110 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in hard/dense soil, complete all as specified and directed. |
| 111 | Hard core ofbroken stone or boulders of gauge n.exc. 63mm, deposited, spread and leveled in layers n.exc. 15cm thick, watered and rammed to a true surface complete all as specified & directed. |
| 112 | Pre-cast reinforced cement concrete type B-1, 1:2:4 using (20 mm graded crushed stone aggregate) as in manhole cover slabs etc set in cement mortar 1:4,complete all as specified and directed. |
| 113 | TMT bars for reinforcement, 6 to 8mm dia & over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engineer-in-Charge. |
| 114 | Kota Stone Slab flooring, 20-25mm thick, best qualityforstaircase landing , treads steps, etc laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, laid over and including 15mm screed layer in cement mortar 1:6, cutting, rubbing, grinding and polishing upto granite finish, complete all as specified. |
| 115 | All as per serial item No 114 herein before but in skirting, riser of staircases etc over and including 10mm thick rendering in cement mortar 1:4 |
| 116 | Brick work with fly ash brick old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:4 complete all as specified & directed. |
| 117 | Steel windows , ventilator fixed type with glazing bars, including one shop coat of red oxide zinc chrome primer complete all as specified & directed. |
| 118 | 3mm thick sheet glass ordinary quality any size and in any type of frame and glazing with oil putty (or beading)in square n.exc 0.5 Sqm in each panes complete all as specified and directed. |
| 119 | Taking down carefully aluminum/copper point wiring on & including hard wood battens, surface conduit and board/blocks etc or through conduits for light , socketor power point ,fan point complete incl fitting such as switches ,sockets, ceiling rose , holder socket, light fitting, regulators and making good disturbed surfaces of wall, floor , ceiling etc and removing materials (other than those for which credit has been given by the contractor) to the MES stores yard for keeping in safe custody complete |
| 120 | Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in existing conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofOne light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : (i) Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original surface and nothing extra shall be paid on this account. (ii)Unit rate is inclusive of cutting chases in wall /foor/PCC for sunken box and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account. |
| 121 | All as per serial item 120 herein before but for socket outlet 3 pin 5 Amps on same board complete all as specified and directed |
| 122 | All as per serial item 120 herein before but for socket outlet 3 pin 6 Amps on independentboard complete all as specified and directed |
| 123 | All as per serial item 120 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSHcable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor |
| 124 | Material and labour forpoint wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofOne light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account.Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account. |
| 125 | All as per serial item 124 herein before but for socket outlet 3 pin 5 Amps on same board complete all as specified and directed |
| 126 | All as per serial item 124 herein before but for socket outlet 3 pin 6 Amps on independentboard complete all as specified and directed |
| 127 | All as per serial item 124 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSHcable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor |
| 128 | Material and labour forpoint wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and includingnew steel sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofOne light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account.Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account. |
| 129 | All as per serial item 128 herein before but for socket outlet 3 pin 5 Amps on same board complete all as specified and directed |
| 130 | All as per serial item 128 herein before but for socket outlet 3 pin 6 Amps on independentboard complete all as specified and directed |
| 131 | All as per serial item 128 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSHcable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor |
| 132 | Switch modular type (ISI marked), single pole, one way 6 Amps, one module(ISI marked), complete all as specified & directed. |
| 133 | Switch modular type (ISI marked), single pole, one way 16 Amps, one module(ISI marked), complete all as specified & directed. |
| 134 | Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed. |
| 135 | Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed. |
| 136 | Switch piano, flush type, 6 amps, 230 volts, single pole, one way (ISI marked) complete all as directed by Engineer-in-charge |
| 137 | Switch piano, flush type, 16 Amps, 230 volts, single pole, one way (ISI marked) complete all as directed by Engineer-in-charge |
| 138 | Sockets outlet multipurpose 2 in 1 pin, 6 and 6Amps flush type ISI marked all as specifiedand directed by Engineer-in-charge |
| 139 | Sockets outlet multipurpose 2 in 1 pin, 6 and 16Amps flush type ISI marked all as specifiedand directed by Engineer-in-charge |
| 140 | Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed. |
| 141 | Modular switch type bell push, single pole, 230 volt one module,(ISI marked) complete all as specified and directed. |
| 142 | Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specifiedand directed by Engineer-in-charge. |
| 143 | Electric Bell, ding dong, AC, 230 volts, single pole all as specified and directed by Engineer-in-charge. |
| 144 | Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed. |
| 145 | LED lamp9 watts, B-22 type complete all as specified . |
| 146 | Disconnecting the power supplyand taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCB\"s ,MCB\"s etcand removing from site, Complete all as specified and directed . |
| 147 | MCCB, 125 Amps, four pole, 3 phase , 16KA, 415 volt with adjustable thermal andmaganetic release, with proper thimble complete all as specified and directed |
| 148 | Vertical TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 125 Amps & outgoing 4 way having IP 43 protection Complete all as specified and directed . |
| 149 | MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way SPN with 200 Amps busbar 240V completed all as specified and directed. |
| 150 | Sheet metal enclosure for DB, flush mountedsingle door suitable for 2 way SPNwithout busbar 240V completed all as specified and directed. |
| 151 | TPN distribution board double door flush mounting with provisions for MCB TPN 4 way, 415 volts having IP 43 protection Complete all as specified and directed . |
| 152 | MCB, SPN , 240 volt,32Amps, 10 KA , \"C\" series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 153 | MCB, SPN , 240 volt,40 to 63Amps, 10 KA , \"C\" series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 154 | MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , \"C\" series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 155 | MCB , TPN/FP 40 to 100 Amp 415 volts, 16 KA , \"C\" series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 156 | LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable sizefixed as in repair complete all as specified and directed. |
| 157 | Slim LED lights fitting, 4 feet,1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed. |
| 158 | Slim LED lights fitting, 2 feet,1x 10W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed. |
| 159 | Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.Note : (i)For the purpose of measurement, 2 single core of 4 sqmm and one single core earth cable of 4 sqmm cableshall be considered as 1 running metre. (ii) colour code shall be Red for phase, Black for neutral and green for earth |
| 160 | Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.Note : (i)For the purpose of measurement, 2 single core of 6 sqmm and one single core earth cable of 6 sqmm cableshall be considered as 1 running metre. (ii) colour code shall be Red for phase, Black for neutral and green for earth |
| 161 | LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,includinglamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, including taking down old street lght complete all as specified and directed. |
| 162 | LED pannel Recess mountedultra slim 2\"x2\" - 36 watts edge lit tile in aluminum extruded housing with opal diffuser suitable for perfect lighting complete including cutting hole of required size in POP/false ceiling making good disturbed including taking down any type ceiling fitting, fixed as in repair complee all as specified and directed. |
| 163 | Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth Complete all as specified and directed . |
| 164 | Exhaust fan, steel body AC single Phase. 230V of size 450mm sweep , 1400 rpm, heavy duty with, blades, and frame and louvers complete all as specified and directed. |
| 165 | Cutting openings, through brick walls in round shape , for 450mm dia exhaust fan and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required including finishing and matching the disturbed surface and removing surplus unserviceable bricks, hard-core, etc. from site and rubbish complete all as specified & directed. |
| 166 | Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. Note(s) :-(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.(ii)PCC chamber shall be constructed 500 mm away from the edge of earth pit.(iii) Rate shall include earth lead and protection pipe of length 7.5m(iv)Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.(v) unit rate including protection pipe and GI wire 4.00mm dia from top to earth plate upto 7.5 meter |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy