| 1 | Taking out carefully Paver blockfrom old footpath and stacking properly at suitable place nearer site etc. complete |
| 2 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. |
| 3 | Taking out stone slabs of flat V-shaped drain of road sideand resetting the same to correct line and level with cement mortar (1 : 4) including cement pointing (1 :2)a) Vertical kerb stone. |
| 4 | Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) |
| 5 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 6 | Supplying and laying in the specified pattern of interlocking concrete block pavements(ICBP) with concrete blocks (with concrete grade as specified as per table 1 of IS 15658 : 2006) manufactured from BIS license manufacturer, with spacer nib (small protruding profiles on the vertical face of a paver block used as device for keeping minimum joint gap in between the paving blocks, as per Cl. No 3.26 of IS: 1568) and specified size and shape with aspect ratio the ratio of length t othickness of a paver block, as per cl.no.3.3 of IS: 15658) as per table 2 of IS: 1568 with flexural strength/breaking load as per annexure g of IS:1568, on the prepared base as certified CBR as per table 1 of IRC SP 63 2018 or else as of 25-35 mm thick (grading of the building sand as per clause 6.5.1 of IRC SP-63) paver block with joint filling sand and completing the edges with cut blocks as perCL.No. 8.7 of IRC SP-63(2018) with proper confinement of bedding and joint filling sand, compaction, levelling and filling up of the edge gap.60 mm thicki) Coloured decorative |
| 7 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.a) Pakur Variety |
| 8 | Supplying, fitting and fixing G.I. pipes of Jindal/Bansal/Nezone make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, long screw, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accessories, specials.)(A) For Exposed Work80 mm dia. medium quality |
| 9 | Supplying, fitting and fixing G.I. pipes of Jindal/Bansal/Nezone make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, long screw, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accessories, specials.)(A) For Exposed Work40 mm dia. medium qualityRef:-Analised rate3.400m x 3nos. + 8.000m x 3 nos. + 2.000m x 2nos. +4.000m x 1nos. + 1.000m x 2nos. = 44.200 mtr |
| 10 | Supplying, fitting and fixing G.I. pipes of Jindal/Bansal/Nezone make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, long screw, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accessories, specials.)(A) For Exposed Work15 mm dia. medium quality |
| 11 | Supplying, fitting & fixing polycarbonate sheet of approvedmake & brand conforming to IS: 14443-1997 and having 50micron UV protection layer under co-extrusion technology,Fire rating being B-s1 as per EN13501-1 certification, fittedand fixed with 60mm wide aluminium channel section topand bottom member in dry-glaze sandwitch system, (unit wt.of top and bottom members: 0.375 kg/m & 0.69 kg/m) ofpproved brand and profile, EPDM quality rubber gaskets,anti dust tape, end closer \"C\" channel and 75 mm long Selftapping screw being drilled through the centre leg of thebottom section with nuts placed at 300 mm apart withoutanyway puncturing the polycarbonate sheet, EPDM Washer16 mm dia & 3 mm thick washer etc complete strictly as permanufacturers specification and direction of Engineer-in Charge. (Payment to be made on area of finished work) .In Roof:- Natural/ Blue/Green/Bronze/Opal/Metallic grey coloura)With 2 wall 6 mm overall thickness ( wt.1.30kg/sqm, Ugvalue being 3.7 W/m2K, Min. cold bending radius of 900 mm) |
| 12 | Supplying, fitting & fixing 1.5mm thick Plain CorrugationPolycarbonate clear sheet made of national brand, excluding the supporting frame work, fitted and fixed with 10mm dia x55mm Self-driving screws, EPDM washers and putty complete with 150mm end lap and one corrugation minimum side lap complete as per specification & direction of Engineer - in - charge including materials, labour, taxes and all other incidental charges.(Payment to be made on area of finished work ). |
| 13 | Providing and fixing exterior quality Aluminium Composite Panel (ACP)wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP)(a) 3mm thick (0.25mm Al.+2.5mm LDPE +0.25mm Al. PVDF coating) |
| 14 | Supplying, fitting & fixing of standard size [180cm(W) x 64cm (D) x 80cm (H)] solid back chrome steel 3 seater Lobby chairas per direction of E.I.C. |
| 15 | Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal /Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge |
| 16 | Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc.(Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge) |
| 17 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC.In Ground FloorOne Coat |
| 18 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.In Ground floor (Two Coat)a) Normal Acrylic Emulsion |
| 19 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection |
| 20 | Supply and delivery of Electronic Timer suitable for 240/ 360/415V, 50 Hz (Make: L &T/ABB/Schneider/Siemens/ GE/Minilec) of the following time (Second) range: . i) 12.0 to 12.0 |
| 21 | Supply and fixing of 240/230 volt, 50 Hz, T.P., power contactor (Make: L & T/ABB/Schneider/Simence/ GE) having contact block of the following range. 25-45 Amp |
| 22 | Supplying and Drawing 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required2 x 84/0.3 (6 sqmm). |
| 23 | Supplying and Drawing 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 2x 22/0.3 (1.5 sqmm) |
| 24 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works150 mm x 100 mm x 65 mm |
| 25 | Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required150 mm x 100 mm x 65 mm |
| 26 | Supply & Fixing 240 V 6 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/ perspex cover and making necessary connections as required |
| 27 | Supply & Fixing 240 V, 6A plug socket (Brand approved by EIC), without switch & plug top, on existing sheet metal switch board with bakelite/ perspex top cover by screws after making housing for plug by cuttingbakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc |
| 28 | Supplying & fixing of 12W LED Bulb Light (Crompton/Bajaj/ Nordusk make) |
| 29 | Supplying & fixing of 20W LED Tube Light with batten (Wipro/Bajaj/ Nordusk make) |
| 30 | Add GST@18% on Sl. No. 1 to 29 |
| 31 | Add labour cess @1% on Sl. No. 1 to 30 |