| 1 | Boring with hydraulic piling rigs with power units, providing andinstalling cast in situ single under reamed piles of specified diameterand length below pile cap in M-25 cement concrete, to carry a safeworking load not less than specified, excluding the cost of steelreinforcement but including the cost of boring with bentonite solutionand the length of the pile to be embedded in pile cap etc. all complete.(Length of pile for payment shall be measured upto to the bottom ofpile cap) |
| 2 | Earth work inexacavationin trenches for foundations and for pipes cables etc.inordinary soil( loan clay orsand)including lift upto 1.5 mand leadup to 30m.&including filling watering& ramming of excavated earth in to trenchesor in to the space betweenthe building & the sides of foundation trenchesorinto the plinthandremoval&disposal of surplusexcavated earthas directed by the Engineer i/c upto a distance of 30 m from the foundation trenches. |
| 3 | Filling of earth in plinth under floor including watering ,ramming , consolidating & dressing complete including lead upto 30 m . & lift upto 1.5 m & including of cost. Carted up to5 km |
| 4 | Providing of sand filling in plinth under floor including watering ,ramming, consolidating anddressing complete including supply of all material labour T&P etc. required for proper completion of the work.lead upto 50 m. and lift upto 1.5m. and including cost of sand.( |
| 5 | Providing and layingin cement concrete 1:4:8 (1 cement :4 coarse sand{FM 2.20-3.60} : stone ballast of 40 mm nominal size)and curing complete,including supply of all material labour T&P etc. required for proper completion of the work, in foundation and floors. |
| 6 | Providing and injecting chemical emulsionfor preconstructional antitermite treatment andcreatinga chemical barrier underand alroundthe column pits wall trenches basement excavation top surface if plinth filling junctionofwall and floor, alongthe the external perimeter of binding expansionjoints, surrounding ofpipes andconduits etc, complete (plinth area shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or anyotherapproved materialsuch as Heptrachlor or chordancewill be used. Therateofapplicationofchemical emulsion shallbe asfollows : (1)Treatment for masonary & foundation 5 liters per/100 sqm.(2) Back fill inimmediate contact with foundation 7.5 liters/100sqm(3) Treatment of top surfaceof plinth filling 5 liters/100 sqm (4)Treatmentjunction of wallandthe floor 7.5 liters /100 sqm(5)Treatmentofsoilalong external perimeter of building 7.5liters/100sqm. (6) Treatment of soil under apronalong external perimter 5 liters/100 sqm. Chapter 8 (1) |
| 7 | R.C.C. workwith cement, approved coarse sandand2 cm. (3/4\") guageapproved stone gritin the proportion of (1:1.5:3)(1cement :1.5coarse sand( FM2.20-3.60) :3 stone aggregate20mm)in RCC FOOTING excludingsupply of reinforcement and its bending but including its fixing in position and binding with 24 B W.G.G.I. bindingwire and including necessary centering and shuttering etc.and also including supply of all materials,labour andtools andplants etc, required for proper completion of the works. |
| 8 | Same As above item No. 6 but for plinth band |
| 9 | Same As above item No.6but forcolumns 1:1.5:3 |
| 10 | Same As above item No. 6but for the havier T-beam i.e. having spans upto 6 m. |
| 11 | Same As above item No. 5 but forlintel band1:2:4 |
| 12 | Same As above item No. 5but forT-BEAMslabs |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for. Foundations, footings, bases of columns, etc. for mass concrete |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for. Suspended floors, roofs, landings, balconies and accessplatform |
| 15 | Centering and shuttering including strutting, propping etc. and removalof form for. Lintels, beams, plinth beams, girders, bressumers andcantilevers |
| 16 | Centering and shuttering including strutting, propping etc. and removalof form for.Columns, Pillars, Piers, Abutments, Posts and Struts |
| 17 | Class 150 brick work in1:6cement and coarsesandof ( FM 1.5-2.20) modulus mortar infoundation and plinth including supply ofall materials,labourand tools and plants etc.requiredforpropercompletion of the work. |
| 18 | Class 150 brick work for one brick thick wall in1:4 cement and coarsesandof ( FM 1.5-2.20)mortar in super-structureaboveplinth levelup to floor two level ( up to two storeys ) including necessary cutting and mouldingofbrickworkas requiredandalsoincludinghoney combed brick work in thickness of wall more than 12cms. |
| 19 | Same As above item No. 17but in1:3 cement and coarse sand (FM 1.50-2.20) mortar in superstructure for wall thickness 12 cms & below. S.I. No.307+309+310a |
| 20 | Providing and laying\"brick coba\" 12mm thick laid with M.150 class brick bat coba 7.50cm. Thick with gap of 15mm to each other. over 20mm. Thick base of cement morter 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with aerelic cement concrete waterproofing compound filed gaps of coba & top of coba mortar mixed with water proofing compoond. in 1:4 cement & coarse & morter finished smooth & top mashed false square 30cmX30cm. & side wall parapet shall be mono tythic plaster wall up to 30cm.higher & junction & corner shall be rounded by brick ballast cement and coarse sand masonary coba with top finished mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour, T & P etc. com.for proper completion of work. CHAPTER 11 NEW ITEM |
| 21 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction withframe of 1st class hard wood and well matched teak 3 ply veneeringwith vertical grains or cross bands and face veneers on both faces ofshutters 35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws |
| 22 | M.S or iron work of small sizes & section such as holding down bolts ,M.S GRILL,wrought to be required from including supply of steel bolts ,nuts,wastage etc. |
| 23 | Providing and fixingZ- SECTIONfor windows and ventilators ofmild steel Tee-sections, joints mitred and welded, including fixing ofnecessary butt hinges and screws and applying a priming coat ofapproved steel primer. |
| 24 | Providing and fixing angle iron frames for doors, windows and ventilatorsof mild steel angle sections of size 35x35x5 mm, joints mitred andwelded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existingT-iron frame or to the wall with dash fastener, including fixing of necessarybutt hinges and screws and applying a priming coat of approved steelprimer, all complete as per the direction of Engineer-In-charge. |
| 25 | Providing and Fixing aluminium extruded section boby tubular type universal hydraulic door closer (having brand logo with ISI, IS :3564, embossed on the boby, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm ) with double speed adjustment with necessary accessories and screws etc. complete. |
| 26 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and asdirected by the Engineer-in-Charge |
| 27 | Mild steel or iron in plain work such asreinforced concrete or reinforced, brick work(whennot includedin anover all rates )wroughttorequired shape as necessary including bending for proper completion of thework andincluding supply of steel itswastage bendhooks andauthorisedover lappingshallbe measured upto floor two level. |
| 28 | 12 mm cement plasterinsingle coat on fair sideofsingle orhalfbrickwall for interior plastering up to floor twolevelincludinginternalrounded angles not exceeding 80mm ingirth nd finshed even and smooth.(1)1 cement:6 C sand (FM 1.50-1.75) |
| 29 | 12mm cement plaster in single coat on of stairs upto floor two level. (Analysis rate)rough side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth andfinished even and smooth no extra for mixing any additive. (1)1 cement :4 C sand (FM 1.50-1.75) |
| 30 | Providing and laying vitrified floor tiles in different sizes(thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including groutingthe joints with white cement and matching pigmentsetc., complete. SIZE 600MM X 600MM |
| 31 | Providing and laying Vitrified tiles in different sizes(thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, cement: 3 coarse sand), of approved make,in all colours &shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3(1 cement:3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete SIZE 600MM X 600MMskirting |
| 32 | Supply & fixing 6 mm thick china white glazed tiles in flooring or in skirting or Dado laid with 1:3cement & approved course sand mortar finished with white cement slurry jointing & polishing complete including supply of all materials,labour & tools & plants etc. required for proper completion of work. |
| 33 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 34 | P/F white cement based putty of average thickness 1mm ,of app. Brand and manufacturer over the plastered wall surface to prepare the surface even and smooth complete. |
| 35 | Distempering (Two coat) with oilbound distemper of approved brand and manufacture of required shade on undercorted of wall surface to give an even shade overand including a priming coat with cement primer of approvedbrand and manufacture such asBerger, J & N Shalimar Paints afterthroughly brushing the surface free from mortar dropping and other foreign matter and also including prepairing the surface even with Plaster of Paris or approved synthetic material and sand paperedsmooth including cost of all materials labour T&P. |
| 36 | Finishing walls with Acrylic Smooth exterior paint of required shade :13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) |