| 1 | A-SUPPLY PART |
| 2 | SUB-STATION MAIN EQUIPMENT TRANSFORMER BAY |
| 3 | 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) |
| 4 | 33 KV Isolatorwithout earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) |
| 5 | 33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase |
| 6 | 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless |
| 7 | 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port |
| 8 | 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm |
| 9 | STEEL STRUCTURES |
| 10 | Pipe Nominal bore 200, 5.9 mm thick |
| 11 | Galvanised steel structures |
| 12 | Galvanized nuts and bolts |
| 13 | CONTROL CABLES |
| 14 | 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS |
| 15 | 6 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS |
| 16 | 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS |
| 17 | Lugs & Ferrules etc. |
| 18 | CONDUCTOR AND HARDWARE |
| 19 | ACSR Conductor Panther |
| 20 | T-Clamp |
| 21 | G.I Flat 50*6 mm |
| 22 | 11KV (UE)XLPE Power Cables (Armoured) |
| 23 | 11 kV630 mm² Single Core XLPE Cable (with one spare length) armoured, FRLS |
| 24 | 11 kV (UE) 3-Core XLPE 185 mm² armoured, FRLS |
| 25 | 11KVHeat shrink termination Cable Kits (Indoor) 630 mm square (1-core) |
| 26 | 11KV Heat shrink termination Cable Kits (Outdoor) 630 mm square (1-core) |
| 27 | 11KV Heat shrink termination Cable Kits (Indoor) 185 mm square(one spare) (3-core) |
| 28 | 11KV Heat shrink terminationCable Kits (Outdoor) 185 mm square (one spare) (3-core) |
| 29 | COST FOR11 KV INDOORSWITCHGEAR OF 33/11 KV SUB-STATION |
| 30 | 11 KV VCB Panel Board ( 12KV,1250A,25KA, Indoor ) With over current,earth fault relays (IEC 61850),MIMIC diagram,Voltmeter,Ammeter,annuniaciation windows with annunciation relays,Hooter on individual Panels ,3-phase tri vector meter-5A,DLMS Compliant with RS-485 Port1 Incoming & 1 outgoings |
| 31 | CIVIL WORKS |
| 32 | 33/11kv power Transformer Foundation |
| 33 | 33kv Equipment Foundation and gantry foundation |
| 34 | Earthing electrode ( 3 meters long, 40 mm dia GI pipe) through GI strips |
| 35 | Extension of Control room Building including with internal wiringand fixing of electrical appliances like lights ,fans,geysers job |
| 36 | Yard Lighting ( 2 Nos yard and 02 Nos CR back side) on 9m Long Poles |
| 37 | B- ERECTION PART |
| 38 | 33/11 KV, 10 MVA Power Transformer (The power transformer shall be provided by the Electric Central Stores Division Jammu |
| 39 | Lifting of power transformer at Electric Central Stores Division Jammu ,Transportation, Erection testing and commissioning at Receiving Station Dandi,Bhaderwah (The ffirm will have to submit the insurance proof ofthe Transformer before despatching from the loading site) |
| 40 | SUB-STATION MAIN EQUIPMENT TRANSFORMER BAY |
| 41 | 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) |
| 42 | 33 KV Isolatorwithout earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) |
| 43 | 33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase |
| 44 | 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless |
| 45 | 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port |
| 46 | 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm |
| 47 | STEEL STRUCTURES |
| 48 | Pipe Nominal bore 200, 5.9 mm thick |
| 49 | Galvanised steel structures |
| 50 | Galvanized nuts and bolts |
| 51 | CONTROL CABLES |
| 52 | 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS |
| 53 | 6 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS |
| 54 | 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS |
| 55 | Lugs & Ferrules etc. |
| 56 | CONDUCTOR AND HARDWARE |
| 57 | ACSR Conductor Panther |
| 58 | T-Clamp |
| 59 | G.I Flat 50*6 mm |
| 60 | 11KV (UE)XLPE Power Cables (Armoured) |
| 61 | 11 kV630 mm² Single Core XLPE Cable (with one spare length) armoured, FRLS |
| 62 | 11 kV (UE) 3-Core XLPE 185 mm² armoured, FRLS |
| 63 | 11KVHeat shrink termination Cable Kits (Indoor) 630 mm square (1-core) |
| 64 | 11KV Heat shrink termination Cable Kits (Outdoor) 630 mm square (1-core) |
| 65 | 11KV Heat shrink termination Cable Kits (Indoor) 185 mm square(one spare) (3-core) |
| 66 | 11KV Heat shrink terminationCable Kits (Outdoor) 185 mm square (one spare) (3-core) |
| 67 | COST FOR11 KV INDOORSWITCHGEAR OF 33/11 KV SUB-STATION |
| 68 | 11 KV VCB Panel Board ( 12KV,1250A,25KA, Indoor ) With over current,earth fault relays (IEC 61850),MIMIC diagram,Voltmeter,Ammeter,annuniaciation windows with annunciation relays,Hooter on individual Panels ,3-phase tri vector meter-5A,DLMS Compliant with RS-485 Port1 Incoming & 1 outgoings |
| 69 | CIVIL WORKS |
| 70 | 33/11kv power Transformer Foundation |
| 71 | 33kv Equipment Foundation and gantry foundation |
| 72 | Earthing electrode ( 3 meters long, 40 mm dia GI pipe) through GI strips |
| 73 | Extension of Control room Building including with internal wiringand fixing of electrical appliances like lights ,fans,geysers job |
| 74 | Yard Lighting ( 2 Nos yard and 02 Nos CR back side) on 9m Long Poles |