| 1 | Taking down carefully point wiring for one light, socket or power etc incl all fittings such as switches sockets, holders, light fittings, fan requlators etc and making good the disturbed surface of wall, ceiling etc includingseperating serviceabel light fittings, switches etc and keeping in safe custody for reuse and removal of unserviceable materials from site complete all as specified and directed. |
| 2 | M & L for concealed point wiringcomplete with 1.5 sq mm FRLSH, PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red/yellow/blue wires for phases and black wire for neutral),drawn into and including non metalic PVC rigid conduit medium grade of suitable size and conduit accessories fixed on wall, floor, roof etc. and including provision of PVC FRLSH insulated 1.5 sq mm copper conductor for earth continuity (Green Colour)and connected to common earth dolly and including pressed steel terminal flush boxesmade out of 1.6 mm thick MS sheet suitable for modular switches concealed in wall and modular cover plate with frame for housing the switches socket,outlet etc.,all as specified and directed by Engineer-in-Charge for one light point/fan point controled by one one way 5/6 Amp switch Note :- Cost of PVC conduit, cutting chases of wall, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface and modular box, modular cover plate with frame are deemed to be included in the quoted rate. |
| 3 | Material & Labour forpoint wiringcomplete with 1.5 sq mm FRLSH, PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red Colour use for Phase & Black Colour use for Neutral),drawn into and including PVC casing- caping (double interlock type) ofnot less than 20mm width with accessories and fittingssuch as bends, elbows, tees, crosses, junction box etc, fixed on wall/ceiling with GI saddles, GI screws, rawl plugs etc. for one light/fan/ bell point controlled by one switch including pressed steel terminal box powder coatedof suitable size with 3 mm thick plastic laminated sheet cover of approved make for housing/mounting switches, sockets & regulators etc. and drawing1.5 sq. mm copper solid conductor PVC insulated, unsheated cable as earth continuity conductor, connected to common earth and earth dolly , all as specified and directed by Engineer-in-ChargeNote :- Cost of PVC casing & capping, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate. |
| 4 | Supply and fixedswitch piano flush type, single pole , 5/6 Amps, one way complete all as specified (Note : Item to be measured if executed under new point wiring) |
| 5 | Supply & fixed ceiling rose surface bakelite 45 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified(Note : Item to be measured if executed under new point wiring) |
| 6 | Supply and fixing for concealedtype sub main wiring with two run of 4.00 Sqmm single core PVC FRLSH, PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and includingthrough Rigid non-metallic PVC conduit(medium) ISI marked of size 25mm bore with all fittings like tee/Bend/Elbow/Reducer/Bell mouth/Junction / Terminal Boxesetc. and fixing accessories such as coupler, lock nuts, saddles, pipe hook etc.including one run of 4.00 Sqmm single core PVC FRLSH, PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified.Note : (i) 2 runs of line conductor,one run of earth continuity conductor, one run of PVCconduit shall be measured as unit length. (ii)Cost of PVC conduit, conductors,making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate. |
| 7 | All as per BOQ Item No 6.00 here-in-beforebut with two run of 6.00 Sqmm single core PVC FRLSH, PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral)including one run of 6.00 Sqmm single core PVC FRLSH, PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified.Note : (i) Note : 2 runs of line conductor,one run of earth continuity conductor, one run of PVCconduit shall be measured as unit length. (ii)Cost of PVC conduit, conductors,making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate. |
| 8 | Supply and fixed 6 watt surface mounted round LED Down light Colour (CW) aesthetically designed made by aluminium P-die-cast enclousers, with separate replaceable constant current driverfor grid ceilling including electrical connection all as directed by EIC. (Note : Item to be measured if executed under new point wiring) |
| 9 | Supply and fixed 12 watt surface mounted round LED Down light Colour (CW) aesthetically designed made by aluminium P-die-cast enclousers, with separate replaceable constant current driverfor grid ceilling including electrical connection all as directed by EIC. (Note : Item to be measured if executed under new point wiring) |
| 10 | Supply and fixed 15 watt surface mounted round LED Down light Colour (CW) aesthetically designed made by aluminium P-die-cast enclousers, with separate replaceable constant current driverfor grid ceilling including electrical connection all as directed by EIC. (Note : Item to be measured if executed under new point wiring) |
| 11 | S&F LED light fitting 40/42 watt reccessed typeof size 600 mm x 600 mm, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz,lumen efficacy of minimum 115 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, ITHD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, CRCA powder coated white after phosphochromate treatment housing, life span of minimum 50000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmmx 3 core complete all as specified and directed by EIC. (Note : Item to be measured if executed under new point wiring) |
| 12 | S&F LED light fitting 35/36 watt reccessed typeof size 600 mm x 600 mm, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz,lumen efficacy of minimum 115 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, ITHD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, CRCA powder coated white after phosphochromate treatment housing, life span of minimum 50000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmmx 3 core complete all as specified and directed by EIC. (Note : Item to be measured if executed under new point wiring) |
| 13 | Supply and fixing in repairs 40 Watt decorative LED Post top lantern lumen efficacy of minimum 115 lumens per watt, isolated electronic LED BIS approved silicon gel filled potted driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 65 CRI greater than 80%, , ITHD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95,life span of minimum 50000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmmx 3 core complete all as specified and directed by |
| 14 | All as per BOQ Item No 13.00 here-in-beforebut but of 20 watt complete all as specified and directed. |
| 15 | Supply and fixing in repairs 40 WattLED wellglass fittings with pressure die cast aluminium canopy & control gear housing suitable for multiple mounting options with both eye bolt & cradle lumen efficacy of minimum 120 lumens per watt,BIS approved silicon gel filled potted driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66 CRI greater than 80%, , ITHD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95,life span of minimum 50000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmmx 3 core complete all as specified and directed by |
| 16 | All as per BOQ Item No 15.00 here-in-beforebut but of capacity 70 watt. |
| 17 | All as per BOQ Item No 15.00 here-in-beforebut but of capacity 30 watt. |
| 18 | Supply and fixing in repairs 50 Watt decorative LED Post top lantern lumen efficacy of minimum 115 lumens per watt, isolated electronic LED BIS approved silicon gel filled potted driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 65 CRI greater than 80%, , ITHD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95,life span of minimum 50000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmmx 3 core complete all as specified and directed by |
| 19 | Supply and fixing in repairsLED Bollard 8/10 watt Pressure die cast powder coated housing with PC diffuser high eficientoutput LEDlumen efficacy of minimum 115 lumens per watt, isolated electronic LED BIS approved silicon gel filled potted driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 65 CRI greater than 80%, , ITHD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95,life span of minimum 50000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmmx 3 core complete all as specified and directed by |
| 20 | Supply & fixingLED street light 60 watt (Min) 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, BIS approved silicon zel fitted potted driver with impact and corrosion resistant complete with driver and lamp, Aluminum die cast housing High efficiency long life LED package in integral module with lumen efficacy of 115 lm/W (Min) and viewing angle of 45 degree to ensure better uniformity, electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other reliability test as perlatest IS. LED operational voltage of 170 volts to 270 volts, frequency of 50 Hz,protection grade IP 66, IK-08 CRI greater than or equal to 70%, CW available CCT of 5700K/6500K, power factor of minimum 0.95 , life span of minimum 50000 working hours cincluding necessary electrical connections by PVC sheathed copper conductor wireof 3 core x 1.5 Sqmm and necessary fixing arrangement all as specified.Note : (i) The minimum requirement of lumen efficiency, lumen output and power consumption has been specified. However,as per availability, the bidders may opted higher specification with out any extra cost. The quoted rate is deem to be included for that and no extra payment will be made on this account.(ii) The fittings should be marked \"Date of installation\" and \"Date of Procurement\" with marker pen.. (Note : Item to be measured if executed under new point wiring) |
| 21 | All as per BOQ Item No 20.00 here-in-beforebut but of capacity 35/36 watt. |
| 22 | S&F LED light fitting 1x9W/1x10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable . (Note : Item to be measured if executed under new point wiring) |
| 23 | Supply and fixing 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single pole and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning |
| 24 | Supply and fixedMCB SPN 32 Amps,\"C\" series 10kA, 240 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed.(Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating) |
| 25 | Supply & fixing in repairs sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated busbar, 4 way single door enclosure made up of CRCA sheet steel,powder coated, IP 30 IK 08 including fixing the DB box flush in wall of any type and making good the distrubed surface to match asthe existing withall as specified and directed by Engr-in-charge |
| 26 | Supply and fixing in repairs SMC junction box/cut-out box/fuse box for single phase/2 core low wattage of size103x103x73 mm, side hinged door, door fixed to base with hinges including connection of wire and terminal etc all as directed by EIC. |
| 27 | Supply and fixing in repairs SMC junction box/cut-out box/fuse box for single phase/2 core low wattage of size140x140x95 mm, side hinged door, door fixed to base with hinges including connection of wire and terminal etc all as directed by EIC. |
| 28 | Disconnecting & taking out defective under ground LT cable from trenches, pole, pipe,floor ,wall etc including bricks ,GI pipes and removing from work site of unserviceable material all as specified and directed.(Excavation/earth work shall be measured & paid separately under relevant item of this schedule) |
| 29 | Supply, Laying,testing and connecting XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade of size 4.0 core 25 sqmm. , laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,includingBrass Compression Cable Gland, Terminal Lugs,clamps,nut & bolts etc all as specified |
| 30 | All as per BOQ Item No 29.00 here-in-before but of size 2.0 core 10 sqmm completeall as specified and as directed |
| 31 | Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier holeetc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soilNote : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding. |
| 32 | Returning, filling in, of soil including spreading leveling, watering and well ramming in layers not exceeding 25 cmcomplete all as specified and directed . |
| 33 | Removing excavated material to a distance n.exc 50M and deposited/ spreaded where directed at a level n. exc 1.5 M above the starting point completeall as specified and as directed |
| 34 | Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cableincludingspreading and punning down to 18 cm thickness complete all as specified and as directed.(Compacted thickness shall be measured) |
| 35 | Supply and laying fly ash best quality, laid in trenches, perpandicular to U/G cable for cable protection completeall as specified and as directed |
| 36 | Supplying and fixingGalvanised mild steel pipe /tubing, light grade complete with all fittings of 40 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers as in cable protection complete all as specified and directed. |