| 1 | Supplying and fixing 415V, 315AmpTPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. |
| 2 | Supplying & fixing 415V,600Amp, sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991)Dimension of Cu. bars [85mm long] -4 x (2x 40x5)mm Dimension of Sheet Metal Box -500x150mm |
| 3 | Supply and Drawing of 95sqmm Single Core Copper FR Insulated Unsheathed Flexible Cable copper, Voltage Grade 1100 Volts, with all necessary tie bar, flexible pipe and allied items, making necy. connection as required( Make :Havells/ Polycab/ Phinolex) |
| 4 | Supply of 4 core 185 sqmm of 1.1 KVgrade alluminium XLPE, PVC/ armouredLT cable( Make :Havells/ Polycab/ Phinolex/ Glowstar) |
| 5 | Laying of three cables above 35 sqmm and upto 185 sqmm in an underground trench in single tier formation (horizontal) the trench size : 915 mm x 760 mm average depth with brick protection on the top of each cable with 8 nos. bricks per Mtr. and 4 nos. bricksper mtr. as separator between every two cables including filling the space between the bricks and cables and also the trench with shifted soil, levelling up and restoring surface duly rammed |
| 6 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry ofXLPE/PVC armoured cables as below a) 4 core 185sqmm |
| 7 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materialsa) 4 core 185sqmm |
| 8 | Supplying & fixing medium gauge 100 mm dia GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required |
| 9 | Supplying and fixing double-door (10+2) way SPN MCB Distribution Boardwith IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.INCOMING-Supplying and fixing 240V 40A DP MCB Isolator on din rail of existing DBs and necessary connection. -- 1 Nos.OUTGOING-Supplying and fixing 240V 6-16A SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection-- 10 Nos. (Make: Legrand / L&T / Crabtree) |
| 10 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\"(Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch(Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish.Average run 9 mtr |
| 11 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works.On Board |
| 12 | Distributionwiring in 1.1 KVsingle core stranded \"FR\"PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. fittings as requireda) 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC |
| 13 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\"(Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch(Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish.Average run 9 mtr |
| 14 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works.On Board |
| 15 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. a)4 sqmm |
| 16 | b)6 sqmm |
| 17 | Supply of single LED light fitting with S & F 1 no. 18W LED tube with Alluminium Heat Sink body including inbuild driver and complete accessories( Make :Philips / CG / Havells/wipro) |
| 18 | Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceilingwith 2 No. 20 mm dia EI conduit (14 SWG) supportsfixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastenerand other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. |
| 19 | Supply of 1200 mm. 5 star BLDC Ceiling Fan, Speed 360 RPM; Air Delivery 220 CMM; Input Power 32W (Colour approved by EIC) complete with blades, canopy,fork, ruber bush etc. but without regulator. as directed by EIC ( Make :Havells/Orient/ Cromptron/ Usha) |
| 20 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. |
| 21 | Supply & FixingSocket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc. |
| 22 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. makingnecy. connections etc. |
| 23 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By TATA-Medium GI pipe |
| 24 | Excavation of soil for installation of Earth Electrode and filling & ramming.For Soft Soil |
| 25 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall includingproviding drilled holes on the busbar complete with GI bolts,nuts, washers, spacing insulators etc. as required |
| 26 | Extra for providing masoneryenclosure on the top of the earthelectrode of overall size 86.36 cm x 86.36 cm x 46 cm deep(below Ground level) complete with cemented brick work(1:6)of 25 cm width duly plastered with cement morter (inside) CIhinged inspection cover of size 36.56 cm x 35.56 cm with lockingarrangement, GI reducer including drilling of 46 nos. 12 mm diaholes on the GI pipe |
| 27 | Connecting the equipments to earth busbar including S & FGI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages 4 SWG |
| 28 | Bituminious Road cutting by using Jac Hamour Compressor Machine, Fuel, Mobile, Compressor Operator and Three Breaker |
| 29 | Supplying ready mixed concrete of M20 Grade with well graded stone chips of 20 mm norminal size containing designed qty of cement per Cu. M of wet concrete produce in computerised batching plant under controlled condition using approved super plastisizer , designing mix following I.S. 10262 and I.S . 456 , transporting the mix with agitation in transit mixer to work site depositeing the mix on a platform erected for the purpose at required level of concreting and then placing the mix its final location of form work , compacting and curing the same complete as per specification & direction of Engineer - in - charge including computerized batching plant transit mixer with all accessories vibrators etc. inclusive of all other incidental of platform and its supporting. |
| 30 | Note:1) All the above rates should be quoted inclusive of all taxes & duties and LWC as applicable.2) Total is rounded off to the nearest rupees. |