| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-01-2025 | Addendum_05 | Date | 16-01-2025 |
| 2 | 02-01-2025 | Addendum_04 | Date | 09-01-2025 |
| 3 | 31-12-2024 | Addendum_03 | Other | 02-01-2025 |
| 4 | 20-12-2024 | Addendum_02 | Other | 02-01-2025 |
| 5 | 16-12-2024 | Addendum_01 | Other | 02-01-2025 |
| Sl. No. | Item Description |
| 1 | GENERAL NOTES(1) This document shall be read in conjunction with doc. \"ANNEXURE-II\" TO SCC - \"SCOPE OF SUPPLY - ELECTRICAL\".Technical Specification for the equipment / material to be supplied by CONTRACTOR is included therein.(2) For \"Limit of Variation\" in the rates / quantities / total value of work, please refer \"SPECIAL CONDITIONS OF CONTRACT\".(3) Refer the document \"LIST OF APPROVED VENDORS / MAKES -ELECTRICAL\" for the makes of equipment / material to be supplied by CONTRACTOR(4) For all the equipment (suitable for Explosive Atmospheres) to be supplied by CONTRACTOR, relevant certification from applicable recognised approving authority shall be provided. (5) For CONTRACTOR supplied items mentioned below, procurement / supply clearance for the items shall be given to CONTRACTOR, in lots as per Project requirement. Subsequent to the receipt of procurement / supply clearance, CONTRACTOR may initiate the required action in this regard.(6) CONTRACTOR should read entire specification to understandin totality the scope of supply and Installation. Every line item for Supplies and Installation should be read along with the respective Installation standard / hook up drawings related to that specific line item to understand the scope of supply and Installation in totality. Any miss outs in supply scope in this regard by the CONTRACTOR shall not be entertained. |
| 2 | EQUIPMENT |
| 3 | LV PANELS (WALL / CONCRETE / STEEL STRUCTURE MOUNTED)Supply of LV panels (wall / concrete / steel structure mounted) as per doc. no.TK-1ZZZA-EL-SPE-0017 (Technical specification for Industrial Equipment) and TK-1ZZZA-EL-SPE-0018 (Technical Specification for Flameproof Equipment) |
| 4 | Industrial Indoor type |
| 5 | For Explosive Atmospheres |
| 6 | LDBLighting Distribution Board) |
| 7 | 18 Way |
| 8 | ELDB(Emergency Lighting Distribution Board) |
| 9 | 15 Way |
| 10 | PDB(Auxiliary Power Distribution Boards) |
| 11 | 15 Way |
| 12 | PDB for Hydro Jet area(Auxiliary Power Distribution Boards)feeder pillar with 1No. 400A I/C and outgoings with 2Nos.250A and 1 no.125A and 1 no. of 63A (Installation type : P10) |
| 13 | LOCAL CONTROL STATIONS (LCS)Supply of Local Control Stations as per doc. no. TK-1ZZZA-EL-SPE-0021 (Technical Specification for Local Control Stations) |
| 14 | LCS for Explosive Atmospheres |
| 15 | Type A3 : Flameproof (Gas Group : IIC) : Start PB (Green); Stop PB (Red) with stay put feature, shrouded type, with pad locking facility & each PB shall have 2NO+2NC contacts |
| 16 | Type B3 :Flameproof (Gas Group : IIC) : Start PB (Green, shrouded type); Stop PB (Red) Mushroom type,with stay put feature, with pad locking facility & each PB shall have 2NO+2NC contacts & Ammeter(1A, MI type) |
| 17 | Type D3 : Flameproof (Gas Group : IIC) : Start PB (Green, shrouded type); Stop PB (Red) Mushroom type, with stay put feature, with pad locking facility & each PB shall have 2NO+2NC contacts. With Local/ Remote Selector switch lockable in both the positions, Key shall be removable only in OFF position &Ammeter(1A, MI type) |
| 18 | Type F4 :Flameproof (Gas Group : IIC) : Start PB (Green, shrouded type); Stop PB (Red), shrouded type; Key lockable emergency stop PB (Red), Mushroom type, with stay put feature, with pad locking facility; each PB shall have 2NO+2NC contacts; Ammeter (4-20mA); Analog RPM meter (4-20mA); key lockable A-M selector switch; Speed Lower-Speed Raise Push buttons |
| 19 | Type J3 :Flameproof (Gas Group : IIC) : Stop PB (Red), Mushroom type, with stay put feature, with pad locking facility & with 2NO+2NC contacts |
| 20 | Type L4 :Flameproof (Gas Group : IIC) :Trip-Neutral-Close (T-N-C) switch shall be spring return to neutral type from CLOSE position with two contacts each for time stamping & tripping signal. Switch shall be lockable in TRIP position. With Local/ Remote Selector switch lockable in both the positions, Key shall be removable only in OFF position & Ammeter(1A, MI type) (Configuration:T-N-C SWITCH + AMMETER + RUN INDICATION + TRIP INDICATION) |
| 21 | Type P3 :Flameproof (Gas Group : IIC) :Trip-Neutral-Close (T-N-C) switch shall be spring return to neutral type from CLOSE position with two contacts each for time stamping & tripping signal. Switch shall be lockable in TRIP position & Ammeter(1A, MI type) |
| 22 | CABLES AND WIRES, GLANDING, TERMINATIONS AND CABLE ROUTING SYSTEMS |
| 23 | CABLE GLANDING AND TERMINATION (HV) |
| 24 | HV Cable glands Industrial type- Supply of cable glands HV cable glands industrial type and all the associated accessories as per \"ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL\".- CONTRACTOR shall be responsible selection and supply of exactly suitable cable glands for the actual cables (technical particulars as per project technical specification) installed at site and equipment cable entry tread.\"OD\" mentioned below indicate approximate overall cable diameters. |
| 25 | HV Cable gland suitable for 6.6 / 6.6 kV (UE) voltage grade, Al conductor, XLPE insulated, screened, armoured power cable |
| 26 | 3C x 240 sq.mm A2XCEFY (UE) (OD : 69 mm) |
| 27 | HV Cable glands for Explosive Atmospheres- Supply of cable glands HV cable glands industrial type and all the associated accessories as per \"ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL\".- CONTRACTOR shall be responsible selection and supply of exactly suitable cable glands for the actual cables (technical particulars as per project technical specification) installed at site and equipment cable entry tread.\"OD\" mentioned below indicate approximate overall cable diameters. |
| 28 | HV Cable gland suitable for 6.6 / 6.6 kV (UE) voltage grade, Al conductor, XLPE insulated, screened, armoured power cable |
| 29 | 3C x 240 sq.mm A2XCEFY (UE) (OD : 69 mm) |
| 30 | HV Cable termination kit - Supply of HV cable termination kit along with all the associated accessories and suitable tinned copper lug for cable termination at designated location- CONTRACTOR shall be responsible for selection and supply of exactly suitable cable termination kit for the cables (technical particulars as per project technical specification) as per the required site conditions and available termination arrangement, and as per the cable technical specification. |
| 31 | HV Cable termination kit Heat shrinkable type (suitable for indoor installation) for 6.6 / 6.6 kV (UE) voltage grade, Al conductor, XLPE insulated, screened, armoured power cable |
| 32 | 3C x 240 sq.mm A2XCEFY (UE) (OD : 69 mm) |
| 33 | CABLE GLANDING AND TERMINATION (LV) |
| 34 | LV Cable glands Industrial type- Supply of cable glands LV cable glands industrial type and all the associated accessories as per \"ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL\".- CONTRACTOR shall be responsible selection and supply of exactly suitable cable glands for the actual cables (technical particulars as per project technical specification) installed at site and equipment cable entry tread.\"OD\" mentioned below indicate approximate overall cable diameters. |
| 35 | Cable glands suitable for 650 / 1100 V (Uo / U) voltage grade, Al / Cu conductor (stranded / solid), XLPE insulated, screened, armoured power / control / lighting cables |
| 36 | 4 x Pair x 2.5 (OD : 26.6 mm) |
| 37 | 8 x Triad x 1.5 (OD : 33.2 mm) |
| 38 | 3 x Triad x 2.5 (OD : -----mm) |
| 39 | 2C x2.5 Sq. mm (2XWY) (OD : 14 mm) |
| 40 | 2C x 6 Sq. mm (2XWY) (OD : 16.6 mm) |
| 41 | 3C x2.5 Sq. mm (2XWY) (OD : 14 mm) |
| 42 | 3C x 4 Sq. mm (2XWY) (OD : 15 mm) |
| 43 | 3C x 6 Sq. mm (2XWY) (OD : 16.5 mm) |
| 44 | 3C x 10 Sq. mm (2XWY) (OD : 18.5 mm) |
| 45 | 3C x 16 Sq. mm (2XWY/2XFY) (OD : 19.7 mm/17.8 mm) |
| 46 | 4C x 10 Sq. mm (2XWY/2XFY) (OD : 21.8 mm) |
| 47 | 5C x 2.5 Sq. mm (2XWY) (OD : 16 mm) |
| 48 | 6C x 2.5 Sq. mm (2XWY) (OD : 17.2 mm) |
| 49 | 7C x 2.5 Sq. mm (2XWY) (OD : 17 mm) |
| 50 | 8C x 2.5 Sq. mm (2XWY) (OD : 18.0 mm) |
| 51 | 10C x 2.5 Sq. mm (2XFY) (OD : 19.5 mm) |
| 52 | 12C x 2.5 Sq. mm (2XFY) (OD : 22.2 mm) |
| 53 | 16C x 2.5 Sq. mm (2XFY) (OD : 22.0 mm) |
| 54 | 24C x 2.5 Sq. mm (2XFY) (OD : 26.7 mm) |
| 55 | 2C x 50 Sq. mm (A2XFY) (OD : 22.7 mm) |
| 56 | 2C x 70 Sq. mm (A2XFY) (OD : 25.5 mm) |
| 57 | 3C x 35 Sq. mm (A2XFY) (OD : 23 mm) |
| 58 | 3C x 50 Sq. mm (A2XFY) (OD : 26 mm) |
| 59 | 3C x 70 Sq. mm (A2XFY) (OD : 29 mm) |
| 60 | 3C x 95 Sq. mm (A2XFY) (OD : 33 mm) |
| 61 | 3C x 120 Sq. mm (A2XFY) (OD : 36 mm) |
| 62 | 3C x 150 Sq. mm (A2XFY) (OD : 39.2 mm) |
| 63 | 3C x 185 Sq. mm (A2XFY) (OD : 45 mm) |
| 64 | 3C x 240 Sq. mm (A2XFY) (OD : 51 mm) |
| 65 | 3C x 300 Sq. mm (A2XFY) (OD : 53 mm) |
| 66 | 4C x 25 Sq. mm (A2XFY) (OD : 22.2 mm) |
| 67 | 4C x 35 Sq. mm (A2XFY) (OD : 27 mm) |
| 68 | 4C x 50 Sq. mm (A2XFY) (OD : 30 mm) |
| 69 | 4C x 70 Sq. mm (A2XFY) (OD : 34 mm) |
| 70 | 4C x 95 Sq. mm (A2XFY) (OD : 37 mm) |
| 71 | 4C x 120 Sq. mm (A2XFY) (OD : 41 mm) |
| 72 | 4C x 150 Sq. mm (A2XFY) (OD : 45 mm) |
| 73 | 4C x 185 Sq. mm (A2XFY) (OD : 50 mm) |
| 74 | 4C x 240 Sq. mm (A2XFY) (OD : 57 mm) |
| 75 | 4C x 300 Sq. mm (A2XFY) (OD : 59.5 mm) |
| 76 | 1C x400 Sq. mm (A2XFY/A2XWY) (OD : 34 mm / 36.5 mm) |
| 77 | 1C x500 Sq. mm (A2XFY/A2XWY) (OD : 37.5 mm / 39.5 mm) |
| 78 | 1C x630 Sq. mm (A2XWaY) (OD : 43.5 mm) |
| 79 | Cable glands suitable for 650 V voltage grade, Cu conductor (stranded / solid), XLPE / PVC insulated, armoured / unarmoured cables for FIRE ALARM AND COMMUNICATION SYSTEM CABLES |
| 80 | 1P x 0.5 sq.mm (OD : 13.2 mm) |
| 81 | 2P x 0.5 sq.mm (OD : 16.4 mm) |
| 82 | 5P x 0.5 sq.mm (OD : 18 mm) |
| 83 | 10P x 0.5 sq.mm (OD : 21.0 mm) |
| 84 | 24P x 0.5 sq.mm (OD : 29.5 mm) |
| 85 | 2P x 1.5 sq.mm (OD : 21.4 mm) |
| 86 | 12P x 1.5 sq. mm (OD : 32 mm) |
| 87 | 20P x 1.5 sq.mm |
| 88 | 50P x 1.5 sq.mm |
| 89 | 100P x 1.5 sq.mm |
| 90 | 1P x 2.5 sq.mm(OD : 23.3 mm) |
| 91 | 8Fibre FO CABLE |
| 92 | LV Cable glands for Explosive Atmospheres- Supply of cable glands LV cable glands for Explosive Atmospheres and all the associated accessories as per \"ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL\".- CONTRACTOR shall be responsible selection and supply of exactly suitable cable glands for the actual cables (technical particulars as per project technical specification) installed at site and equipment cable entry tread.\"OD\" mentioned below indicate approximate overall cable diameters. |
| 93 | Cable glands suitable for 650 / 1100 V (Uo / U) voltage grade, Al / Cu conductor (stranded / solid), XLPE insulated, screened, armoured power / control / lighting cables |
| 94 | 4 x Pair x 2.5 (OD : 26.6 mm) |
| 95 | 8 x Tried x 1.5 (OD : 33.2 mm) |
| 96 | 2C x2.5 Sq. mm (2XWY) (OD : 14 mm) |
| 97 | 2C x 4 Sq. mm (2XWY) (OD : 15.5 mm) |
| 98 | 2C x 6 Sq. mm (2XWY) (OD : 16.6 mm) |
| 99 | 2C x 10 Sq. mm (2XWY) (OD : 18.5 mm) |
| 100 | 2C x 16 Sq. mm (2XWY/2XFY) (OD : 18.8 mm) |
| 101 | 3C x2.5 Sq. mm (2XWY) (OD : 14 mm) |
| 102 | 3C x 4 Sq. mm (2XWY) (OD : 15 mm) |
| 103 | 3C x 6 Sq. mm (2XWY) (OD : 16.5 mm) |
| 104 | 3C x 10 Sq. mm (2XWY) (OD : 18.5 mm) |
| 105 | 3C x 16 Sq. mm (2XWY/2XFY) (OD : 19.7 mm/17.8 mm) |
| 106 | 4C x2.5 Sq. mm (2XWY) (OD : 15 mm) |
| 107 | 4C x 4 Sq. mm (2XWY) (OD : 16 mm) |
| 108 | 4C x 6 Sq. mm (2XWY) (OD : 17.5 mm) |
| 109 | 4C x 10 Sq. mm (2XWY/2XFY) (OD : 21.8 mm) |
| 110 | 4C x 16 Sq. mm (2XWY/2XFY) (OD : 22.8 mm/21.2 mm) |
| 111 | 5C x 2.5 Sq. mm (2XWY) (OD : 16 mm) |
| 112 | 6C x 2.5 Sq. mm (2XWY) (OD : 17.2 mm) |
| 113 | 7C x 2.5 Sq. mm (2XWY) (OD : 17 mm) |
| 114 | 8C x 2.5 Sq. mm (2XWY) (OD : 18.0 mm) |
| 115 | 10C x 2.5 Sq. mm (2XFY) (OD : 19.5 mm) |
| 116 | 12C x 2.5 Sq. mm (2XFY) (OD : 22.2 mm) |
| 117 | 16C x 2.5 Sq. mm (2XFY) (OD : 22.0 mm) |
| 118 | 24C x 2.5 Sq. mm (2XFY) (OD : 26.7 mm) |
| 119 | 3C x 25 Sq. mm (A2XFY) (OD : 21 mm) |
| 120 | 3C x 35 Sq. mm (A2XFY) (OD : 23 mm) |
| 121 | 3C x 50 Sq. mm (A2XFY) (OD : 26 mm) |
| 122 | 3C x 70 Sq. mm (A2XFY) (OD : 29 mm) |
| 123 | 3C x 95 Sq. mm (A2XFY) (OD : 33 mm) |
| 124 | 3C x 120 Sq. mm (A2XFY) (OD : 36 mm) |
| 125 | 3C x 150 Sq. mm (A2XFY) (OD : 39.2 mm) |
| 126 | 3C x 185 Sq. mm (A2XFY) (OD : 45 mm) |
| 127 | 3C x 240 Sq. mm (A2XFY) (OD : 51 mm) |
| 128 | 3C x 300 Sq. mm (A2XFY) (OD : 53 mm) |
| 129 | 4C x 25 Sq. mm (A2XFY) (OD : 22.2 mm) |
| 130 | 4C x 35 Sq. mm (A2XFY) (OD : 27 mm) |
| 131 | 4C x 50 Sq. mm (A2XFY) (OD : 30 mm) |
| 132 | 4C x 70 Sq. mm (A2XFY) (OD : 34 mm) |
| 133 | 4C x 95 Sq. mm (A2XFY) (OD : 37 mm) |
| 134 | 4C x 120 Sq. mm (A2XFY) (OD : 41 mm) |
| 135 | 4C x 150 Sq. mm (A2XFY) (OD : 45 mm) |
| 136 | 4C x 185 Sq. mm (A2XFY) (OD : 50 mm) |
| 137 | 4C x 240 Sq. mm (A2XFY) (OD : 57 mm) |
| 138 | 4C x 300 Sq. mm (A2XFY) (OD : 59.5 mm) |
| 139 | 1C x400 Sq. mm (A2XFY/A2XWY) (OD : 34 mm / 36.5 mm) |
| 140 | 1C x500 Sq. mm (A2XFY/A2XWY) (OD : 37.5 mm / 39.5 mm) |
| 141 | 1C x630 Sq. mm (A2XWaY) (OD : 43.5 mm) |
| 142 | 3.5C x 150 Sq. mm (A2XFY) |
| 143 | 3.5C x 300 Sq. mm (A2XFY) |
| 144 | Cable glands suitable for 650 V voltage grade, Cu conductor (stranded / solid), XLPE / PVC insulated, armoured / unarmoured cables for FIRE ALARM AND COMMUNICATION SYSTEM CABLES |
| 145 | 1P x 0.5 sq.mm (OD : 13.2 mm) |
| 146 | 2P x 0.5 sq.mm (OD : 16.4 mm) |
| 147 | 5P x 0.5 sq.mm (OD : 18 mm) |
| 148 | 10P x 0.5 sq.mm (OD : 21.0 mm) |
| 149 | 24P x 0.5 sq.mm (OD : 29.5 mm) |
| 150 | 1P x 1.5 sq.mm (OD : 14 mm) |
| 151 | 2P x 1.5 sq.mm (OD : 21.4 mm) |
| 152 | 12P x 1.5 sq. mm (OD : 32 mm) |
| 153 | 20P x 1.5 sq.mm |
| 154 | 50P x 1.5 sq.mm |
| 155 | 100P x 1.5 sq.mm |
| 156 | 1P x 2.5 sq.mm(OD : 23.3 mm) |
| 157 | 2P x 2.5 sq.mm(OD : 23.3 mm) |
| 158 | 4P x 2.5 sq.mm(OD : 26.6 mm) |
| 159 | 12P x 2.5 sq. mm (OD : 38.6 mm) |
| 160 | 20P x 2.5 sq.mm |
| 161 | LV Cable gland reducers / expanders- Supply of LV Cable gland reducers / expanders and all the associated accessories as per \"ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL\".- CONTRACTOR shall be responsible selection and supply of exactly suitable reducers / expanders for the actual cables gland (technical particulars as per project technical specification) installed at site and equipment cable entry tread. |
| 162 | LV Cable gland reducers Industrial type |
| 163 | M20 x 1.5 (Male thread) to M16 x 1.5 (Female thread) |
| 164 | M25 x 1.5 (Male thread) to M20 x 1.5 (Female thread) |
| 165 | M32 x 1.5 (Male thread) to M25 x 1.5 (Female thread) |
| 166 | M50 x 1.5 (Male thread) to M32 x 1.5 (Female thread) |
| 167 | M63 x 1.5 (Male thread) to M50 x 1.5 (Female thread) |
| 168 | M80 x 1.5 (Male thread) to M63 x 1.5 (Female thread) |
| 169 | LV Cable gland expander Industrial type |
| 170 | M16 x 1.5 (Male thread) to M20 x 1.5 (Female thread) |
| 171 | M20 x 1.5 (Male thread) to M25 x 1.5 (Female thread) |
| 172 | M25 x 1.5 (Male thread) to M32 x 1.5 (Female thread) |
| 173 | M32 x 1.5 (Male thread) to M50 x 1.5 (Female thread) |
| 174 | M50 x 1.5 (Male thread) to M63 x 1.5 (Female thread) |
| 175 | M63 x 1.5 (Male thread) to M80 x 1.5 (Female thread) |
| 176 | LV Cable gland reducers for Explosive Atmospheres |
| 177 | M20 x 1.5 (Male thread) to M16 x 1.5 (Female thread) |
| 178 | M25 x 1.5 (Male thread) to M20 x 1.5 (Female thread) |
| 179 | M32 x 1.5 (Male thread) to M25 x 1.5 (Female thread) |
| 180 | M50 x 1.5 (Male thread) to M32 x 1.5 (Female thread) |
| 181 | M63 x 1.5 (Male thread) to M50 x 1.5 (Female thread) |
| 182 | M80 x 1.5 (Male thread) to M63 x 1.5 (Female thread) |
| 183 | LV Cable gland expander for Explosive Atmospheres |
| 184 | M16 x 1.5 (Male thread) to M20 x 1.5 (Female thread) |
| 185 | M20 x 1.5 (Male thread) to M25 x 1.5 (Female thread) |
| 186 | M25 x 1.5 (Male thread) to M32 x 1.5 (Female thread) |
| 187 | M32 x 1.5 (Male thread) to M50 x 1.5 (Female thread) |
| 188 | M50 x 1.5 (Male thread) to M63 x 1.5 (Female thread) |
| 189 | M63 x 1.5 (Male thread) to M80 x 1.5 (Female thread) |
| 190 | LV Cable lugs- Supply of crimping type lugs for power / control / lighting / earthing cables of various sizes as per \"ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL\".- CONTRACTOR shall be responsible selection and supply of exactly suitable lug for the actual cable conductors for the cables (technical particulars as per project technical specification) installed at site and available termination arrangement. |
| 191 | Tinned copper, insulated, Pin type lugs |
| 192 | 1.5 sq.mm |
| 193 | 2.5 sq.mm |
| 194 | Tinned copper, insulated, Ring type lugs |
| 195 | 1.5 sq.mm |
| 196 | 2.5 sq.mm |
| 197 | Tinned copper, tubular type, heavy duty lugs for bolted connection |
| 198 | 4 sq. mm |
| 199 | 6 sq. mm |
| 200 | 10 sq. mm |
| 201 | 16 sq. mm |
| 202 | 25 sq. mm |
| 203 | 35 sq.mm |
| 204 | 50 sq. mm |
| 205 | 70 sq. mm |
| 206 | 95 sq. mm |
| 207 | 120 sq. mm |
| 208 | 150 sq. mm |
| 209 | 185 sq. mm |
| 210 | 240 sq. mm |
| 211 | 300 sq. mm |
| 212 | 630 sq. mm |
| 213 | Tinned copper, tubular type, long barrel type heavy duty lugs for bolted connection |
| 214 | 50 sq. mm |
| 215 | 70 sq. mm |
| 216 | 95 sq. mm |
| 217 | 120 sq. mm |
| 218 | 150 sq. mm |
| 219 | 185 sq. mm |
| 220 | 240 sq. mm |
| 221 | 300 sq. mm |
| 222 | 630 sq. mm |
| 223 | Tinned copper, tubular type, large diameter lugs for bolted connection of earthing conductor |
| 224 | 6 sq. mm |
| 225 | 10 sq. mm |
| 226 | 35 sq.mm |
| 227 | 95 sq. mm |
| 228 | 120 sq. mm |
| 229 | 185 sq. mm |
| 230 | 8 mm dia. GI wire rope |
| 231 | 10 mm dia. GI wire rope |
| 232 | 16 mm dia. GI wire rope |
| 233 | Tinned copper, insulated, Pin type lugs (for Paired Cable) |
| 234 | 0.5 sq.mm |
| 235 | 1.5 sq.mm |
| 236 | 2.5 sq.mm |
| 237 | Cable entry blanking plugs - Supply of cable entry blanking plugs and all the associated accessories for sealing of unused cable entries, as per \"ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL\".- CONTRACTOR shall be responsible selection and supply of exactly suitable Cable entry blanking plugs as per equipment cable entry tread at site. |
| 238 | Cable entry blanking plugs Industrial type |
| 239 | M16 (OD 13mm) |
| 240 | M20 ( OD 19.5 MM) |
| 241 | M25 ( OD 25.5mm) |
| 242 | M32 (OD 32.9mm) |
| 243 | M50 (OD 51mm) |
| 244 | M63 (OD 59mm) |
| 245 | Cable entry blanking plugs For Explosive Atmospheres |
| 246 | M16 (OD 13mm) |
| 247 | M20 ( OD 19.5 MM) |
| 248 | M25 ( OD 25.5mm) |
| 249 | M32 (OD 32.9mm) |
| 250 | M50 (OD 51mm) |
| 251 | M63 (OD 59mm) |
| 252 | CABLE JOINTING |
| 253 | Cable straight through jointing kit indoor type- Supply of cable jointing kit along with all the associated accessories as per \"ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL\". |
| 254 | HV Cable straight through jointing kit Heat shrinkable type (suitable for indoor installation) for 33 / 33 kV (UE) voltage grade, Al conductor, XLPE insulated, screened, armoured power cable |
| 255 | 1C x 630 sq.mm A2XCEWaY (UE) |
| 256 | PREFABRICATED CABLE TRAYS |
| 257 | Prefabricated Cable Trays (GI)- Supply of prefabricated GI perforated and ladder type cable tray / covers, tray separators along with all the associated consumable material for assembly and appropriate installation of the same, as per doc. no. TK-1ZZZA-EL-SPE-0016 (Technical Specification for GI cable Trays) |
| 258 | Cable Trays Perforated (GI) (Length 3 mtr per piece) including required hardware as per Installation dwg |
| 259 | 50 mm wide |
| 260 | 100 mm wide |
| 261 | 150 mm wide |
| 262 | Coupler plates along with SS304 fixing hardware |
| 263 | GI Coupler plates with 3 mm thick, 4 holes on both the sides of size M10 hole & M8 hardware (along with necessary fixing hardware –stainless steel (SS304) nut, bolt, lock-nut) for 50/100/150 W perforated cable trays mentioned above. (Note : 1 no. set = 2 nos. coupler plates each) |
| 264 | Stainless Steel Coupler plates with 2 mm thick, 4 holes on both the sides of size M10 hole & M8 hardware (along with necessary fixing hardware –stainless steel (SS304) nut, bolt, lock-nut) for 50/100/150W perforated cable trays mentioned above. (Note : 1 no. set = 2 nos. coupler plates each) |
| 265 | Tray Covers (length 3 mtr per piece) with fixing clamps (at every 1 meter) along with necessary SS304 hardware |
| 266 | 150 mm wide |
| 267 | 100 mm wide |
| 268 | Cable Ladders (GI) (Length 3 mtr per piece) |
| 269 | 150 mm wide |
| 270 | 300 mm wide |
| 271 | 600 mm wide |
| 272 | Pre-Fabricated 90 degree horizontal bends (Bending Radius 300mm) |
| 273 | 300 mm wide |
| 274 | 600 mm wide |
| 275 | Pre-Fabricated 90 degree horizontal bends (Bending Radius 600mm) |
| 276 | 300 mm wide |
| 277 | 600 mm wide |
| 278 | Pre-Fabricated 90 degree horizontal bends (Bending Radius 1200mm) |
| 279 | 300 mm wide |
| 280 | 600 mm wide |
| 281 | Pre-Fabricated 90 degree Inside Vertical bends (Bending Radius 300mm) |
| 282 | 600 mm wide |
| 283 | Pre-Fabricated 90 degree Inside Vertical bends (Bending Radius 600mm) |
| 284 | 300 mm wide |
| 285 | 600 mm wide |
| 286 | Pre-Fabricated 90 degree Inside Vertical bends (Bending Radius 1200mm) |
| 287 | 300 mm wide |
| 288 | Pre-Fabricated 90 degree Outside Vertical bends (Bending Radius 300mm) |
| 289 | 600 mm wide |
| 290 | Pre-Fabricated 90 degree Outside Vertical bends (Bending Radius 600mm) |
| 291 | 300 mm wide |
| 292 | 600 mm wide |
| 293 | Pre-Fabricated 90 degree Outside Vertical bends (Bending Radius 1200mm) |
| 294 | 300 mm wide |
| 295 | Pre-Fabricated 45 degree horizontal bends (Bending Radius 300mm) |
| 296 | 300 mm wide |
| 297 | 600 mm wide |
| 298 | Pre-Fabricated 45 degree horizontal bends (Bending Radius 600mm) |
| 299 | 300 mm wide |
| 300 | 600 mm wide |
| 301 | Pre-Fabricated 45 degree horizontal bends (Bending Radius 900mm) |
| 302 | 300 mm wide |
| 303 | 600 mm wide |
| 304 | Pre-Fabricated 45 degree Inside Vertical bends (Bending Radius 300mm) |
| 305 | 300 mm wide |
| 306 | 600 mm wide |
| 307 | Pre-Fabricated 45 degree Inside Vertical bends (Bending Radius 600mm) |
| 308 | 300 mm wide |
| 309 | 600 mm wide |
| 310 | Pre-Fabricated 45 degree Inside Vertical bends (Bending Radius 900mm) |
| 311 | 300 mm wide |
| 312 | 600 mm wide |
| 313 | Pre-Fabricated 45 degree Outside Vertical bends (Bending Radius 300mm) |
| 314 | 300 mm wide |
| 315 | 600 mm wide |
| 316 | Pre-Fabricated 45 degree Outside Vertical bends (Bending Radius 600mm) |
| 317 | 300 mm wide |
| 318 | 600 mm wide |
| 319 | Pre-Fabricated 45 degree Outside Vertical bends (Bending Radius 900mm) |
| 320 | 300 mm wide |
| 321 | 600 mm wide |
| 322 | Pre Fabricated Cable Tray Reducer |
| 323 | 600 to 300 mm Reducer, Right Hand Side |
| 324 | 600 to 300 mm Reducer, Left Hand Side |
| 325 | 300 to 150 mm Reducer, Right Hand Side |
| 326 | 300 to 150 mm Reducer, Left Hand Side |
| 327 | Pre Fabricated Equal Tee’s (Bending Radius-300 mm) |
| 328 | 600 mm wide |
| 329 | Pre Fabricated Equal Tee’s (Bending Radius-600 mm) |
| 330 | 300 mm wide |
| 331 | Pre Fabricated Equal Tee’s (Bending Radius-900 mm) |
| 332 | 300 mm wide |
| 333 | 600 mm wide |
| 334 | Pre Fabricated Unequal Tee’s (Bending Radius-300 mm) |
| 335 | 300 x 150 x 300 mm wide |
| 336 | 600 x 150 x 600 mm wide |
| 337 | 600 x 300 x 600 mm wide |
| 338 | Pre Fabricated Unequal Tee’s (Bending Radius-600 mm) |
| 339 | 300 x 150 x 300 mm wide |
| 340 | 600 x 150 x 600 mm wide |
| 341 | 600 x 300 x 600 mm wide |
| 342 | Coupler plates along with SS304 fixing hardware |
| 343 | GI Coupler plates with 3 mm thick, 4 holes on both the sides of size M10 hole & M8 hardware (along with necessary fixing hardware –stainless steel nut, bolt, lock-nut) for 150/300/450/600 W ladder type cable trays mentioned above. (Note : 1 no. set = 4 nos. coupler plates each) |
| 344 | Stainless Steel Coupler plates with 2 mm thick, 4 holes on both the sides of size M10 hole & M8 hardware (along with necessary fixing hardware –stainless steel nut, bolt, lock-nut) for 150/300/450/600W ladder type cable trays mentioned above. (Note : 1 no. set = 4 nos. coupler plates each) |
| 345 | Hinged GI plates for below bends with 3 mm thick, 4 holes on both the sides of size M10 hole & M8 hardware (along with necessary fixing hardware –stainless steel (SS304) nut, bolt, lock-nut) for 150/300/450/600W ladder type cable trays mentioned above. (Note : 1 no. set = 4 nos. coupler plates each) |
| 346 | Hinged GI plates for Horizontal 45 degree bends |
| 347 | Hinged GI plates for Vertical 45 degree bends |
| 348 | Clamps for fixing 45 degree Horizontal & Vertical Cable Tray cover along with necessary fixing hardware –stainless steel (SS304) nut, bolt, lock-nut for ladder type cable trays mentioned above. |
| 349 | Clamps for 300 mm wide tray |
| 350 | Clamps for 600 mm wide tray |
| 351 | Cable Tray Covers (GI) (Length 3 mtr per piece) |
| 352 | 150 mm wide |
| 353 | 300 mm wide |
| 354 | 600 mm wide |
| 355 | Pre Fabricated Tray Cover for Horizontal 900 Bends (Bending Radius-300 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware |
| 356 | 300 mm wide |
| 357 | Pre Fabricated Tray Cover for Horizontal 900 Bends (Bending Radius-600 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware |
| 358 | 300 mm wide |
| 359 | 600 mm wide |
| 360 | Pre Fabricated Tray Cover for Horizontal 900 Bends (Bending Radius-900 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware |
| 361 | 300 mm wide |
| 362 | Pre Fabricated Tray Cover for Horizontal 900 Bends (Bending Radius-1200 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware |
| 363 | 300 mm wide |
| 364 | 600 mm wide |
| 365 | Pre Fabricated Tray Cover for Inside Vertical 900Bends (Bending Radius-300 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware |
| 366 | 600 mm wide |
| 367 | Pre Fabricated Tray Cover for Inside Vertical 900Bends (Bending Radius-600 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware |
| 368 | 300 mm wide |
| 369 | 600 mm wide |
| 370 | Pre Fabricated Tray Cover for Inside Vertical 900Bends (Bending Radius-900 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware |
| 371 | 300 mm wide |
| 372 | Pre Fabricated Tray Cover for Inside Vertical 900Bends (Bending Radius-1200 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware |
| 373 | 300 mm wide |
| 374 | Pre Fabricated Tray Cover for Outside Vertical 900Bends (Bending Radius-300 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware |
| 375 | 600 mm wide |
| 376 | Pre Fabricated Tray Cover for Outside Vertical 900Bends (Bending Radius-600 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware |
| 377 | 300 mm wide |
| 378 | 600 mm wide |
| 379 | Pre Fabricated Tray Cover for Outside Vertical 900Bends (Bending Radius-900 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware |
| 380 | 300 mm wide |
| 381 | Pre Fabricated Tray Cover for Outside Vertical 900Bends (Bending Radius-1200 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware |
| 382 | 300 mm wide |
| 383 | Pre Fabricated Tray Cover for Horizontal 450Bends (Bending Radius-300 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware |
| 384 | 300 mm wide |
| 385 | 600 mm wide |
| 386 | Pre Fabricated Tray Cover for Horizontal 450Bends (Bending Radius-600 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware |
| 387 | 300 mm wide |
| 388 | 600 mm wide |
| 389 | Pre Fabricated Tray Cover for Horizontal 450Bends (Bending Radius-900 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware |
| 390 | 300 mm wide |
| 391 | 600 mm wide |
| 392 | Pre Fabricated Tray Cover for inside Vertical 450Bends (Bending Radius-300 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware |
| 393 | 300 mm wide |
| 394 | 600 mm wide |
| 395 | Pre Fabricated Tray Cover for inside Vertical 450Bends (Bending Radius-600 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware |
| 396 | 600 mm wide |
| 397 | Pre Fabricated Tray Cover for inside Vertical 450Bends (Bending Radius-900 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware |
| 398 | 300 mm wide |
| 399 | 600 mm wide |
| 400 | Pre Fabricated Tray Cover for Outside Vertical 450Bends (Bending Radius-300 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware |
| 401 | 300 mm wide |
| 402 | 600 mm wide |
| 403 | Pre Fabricated Tray Cover for Outside Vertical 450Bends (Bending Radius-600 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware |
| 404 | 300 mm wide |
| 405 | 600 mm wide |
| 406 | Pre Fabricated Tray Cover for Outside Vertical 450Bends (Bending Radius-900 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware |
| 407 | 300 mm wide |
| 408 | 600 mm wide |
| 409 | Pre Fabricated Tray Cover for Cable Tray Reducer with 2 nos. fixing clampsalong with necessary SS304 hardware |
| 410 | 600 to 300 mm Reducer, Right Hand Side |
| 411 | 600 to 300 mm Reducer, Left Hand Side |
| 412 | 300 to 150 mm Reducer, Right Hand Side |
| 413 | 300 to 150 mm Reducer, Left Hand Side |
| 414 | Pre Fabricated Tray Cover for Equal Tee’s (Bending Radius-300 mm) with 3 nos. fixing clampsalong with necessary SS304 hardware |
| 415 | 600 mm wide |
| 416 | Pre Fabricated Tray Cover for Equal Tee’s (Bending Radius-600 mm) with 3 nos. fixing clampsalong with necessary SS304 hardware |
| 417 | 300 mm wide |
| 418 | 600 mm wide |
| 419 | Pre Fabricated Tray Cover for Equal Tee’s (Bending Radius-900 mm) with 3 nos. fixing clampsalong with necessary S3304 hardware |
| 420 | 300 mm wide |
| 421 | 600 mm wide |
| 422 | Pre Fabricated Tray Cover for Unequal Tee’s(Bending Radius-300 mm) with 3 nos. fixing clampsalong with necessary SS304 hardware |
| 423 | 300 x 300 x 150 mm wide |
| 424 | 600 x 600 x 150 mm wide |
| 425 | 600 x 600 x 300 mm wide |
| 426 | Pre Fabricated Tray Cover for Unequal Tee’s (Bending Radius-600 mm) with 3 nos. fixing clampsalong with necessary SS304 hardware |
| 427 | 300 x 300 x 150 mm wide |
| 428 | 600 x 600 x 150 mm wide |
| 429 | 600 x 600 x 300 mm wide |
| 430 | Z Clamps for Holding Horizontal Cable Tray, Material - HDGI, thickness - 2 mm with necessary fixing hardware with (with M12 hole & M10 hardware SS304 nut, bolt, lock-nut) |
| 431 | Separators for Cable Ladders (GI) |
| 432 | 300 mm / 600 mm wide |
| 433 | CONDUITS FOR CABLE LAYING / PROTECTION AND PULL BOXES- Supply of heavy duty rigid GI / PVC conduits and all the associated accessories - Supply of accessories such as GI clamps, joints, bends reducers / adaptors for the conduits and other consumable material such as edge protection grommet at either ends for GIconduits as per the site requirement is considered in running meter length of the conduits. |
| 434 | Rigid GI conduits |
| 435 | 25 mm nominal dia |
| 436 | 50 mm nominal dia |
| 437 | 150 mm nominal dia |
| 438 | Rigid GI conduits RED coloured (For Fire Alarm System cables) |
| 439 | 25 mm nominal dia |
| 440 | 50 mm nominal dia |
| 441 | Heavy duty PVC conduits |
| 442 | 150 mm nominal dia |
| 443 | Flexible PVC conduits |
| 444 | 20 mm nominal dia |
| 445 | Pull boxes for cable pulling in conduitsSupply of pull boxes (GI enclosure) |
| 446 | 4 way Pull boxes,100mm L x 100mm Wx 75mm D,1no. 25mm knockout on all four sides |
| 447 | 4 way Pull boxes, 115mm L x 115mm Wx 75mm D,2nos. 25 mm knockout on all four sides |
| 448 | 4 way Pull boxes, 265mm L x 165mm Wx 75mm D, 5nos. 25mm knockout at top / bottom and 2nos. 25mm knockout on each sides. |
| 449 | LIGHTING, SMALL POWER, WELDING SOCKETS AND JUNCTION BOXES |
| 450 | LIGHTING |
| 451 | Lighting fixturesSupply of lighting fixtures and associated components / accessories such as lamps, chokes, condensers, reflectors, control gear box for non-integral fixtures etc. as per doc. no. TK-1ZZZA-EL-SPE-0019 (Technical Specification for Industrial Light Fixture) and TK-1ZZZA-EL-SPE-0020 (Technical Specification for Flameproof Light Fixture) |
| 452 | Lighting Fixtures for Explosive Atmospheres |
| 453 | 40W LED Ex-d FLP Well Glass Light Fixture |
| 454 | 100W LED Ex-d FLP Medium Bay Light Fixture |
| 455 | 150W LED Ex-d FLP Flood Light fixture |
| 456 | 20W LED Ex-d FLP Aviation Light |
| 457 | 26W, 110V DC LED Ex-d FLP Well Glass Fixture |
| 458 | Special Lighting fixturesSupply of special lighting fixtures and all the associated accessories, as per \"ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL\". |
| 459 | Emergency lighting fixture with built-in battery |
| 460 | 1x18W, Fluorescent, Industrial |
| 461 | 1x18W, Fluorescent, for Explosive Atmospheres |
| 462 | Hand lamps |
| 463 | 24V Hand lamps for Explosive Atmospheres along with 20m extension cable 3c x 1.5sq.mm, YY, 20m, along with the plug suitable for 24V, 5A Industrial switch socket |
| 464 | SMALL POWERSupply of various small power equipment and all associated accessories, as per \"ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL\". |
| 465 | Industrial type switch socket outlets (for Indoor Installation) |
| 466 | 10A, single phase socket outlet with 1no. 3 pin socket, in sheet steel enclosure |
| 467 | 10A, single phase socket outlet with 1 No. 10 A, 10 kA, SPMCB, in sheet steel enclosure |
| 468 | 10A, single phase switch socket outlet with 1no. 3 pin socket and 1 No. 10 A, 10 kA, SPMCB, in sheet steel enclosure |
| 469 | 20A, single phase socket outlet with 1no. 3 pin socket, in sheet steel enclosure |
| 470 | 20A, single phase socket outlet with 1 No. 20 A, 10 kA, SPMCB, in sheet steel enclosure |
| 471 | 20A, single phase switch socket outlet with 1no. 3 pin socket and 1 No. 20 A, 10 kA, SPMCB, in sheet steel enclosure |
| 472 | Convenience Switch socket outlets |
| 473 | Conveniencesockets (single phase) for Explosive Atmospheres |
| 474 | 16A, 3 pin,240V AC single phase socket outlet with DPMCB in die cast Al LM6 enclosure, Type S01 |
| 475 | Switch socket unit (portable) for Explosive Atmospheres |
| 476 | 240V,16A and 24V, 5A combination type switch socket unit for Explosive Atmospheres, with built-in 100VA, 240V / 24V transformer |
| 477 | JUNCTION BOXES (JB) / POWER JUNCTION BOXES (JB)- Supply of various types of junction boxes / power junction boxes suitable for the required cable entries and all associated accessories, as per doc. no.TK-1ZZZA-EL-SPE-0017 (Technical specification for Industrial Equipment) and TK-1ZZZA-EL-SPE-0018 (Technical Specification for Flameproof Equipment)- Supply of junction boxes suitable for bottom entry of incoming and outgoing cables, inclusive of suitable terminals for undrilled gland plate, cable terminations, busbars for cable termination as required, facility for earthing cable termination inside and outside the termination, along with the associated accessories such plugs for cable openings, fixing hardware |
| 478 | Junction boxes Industrial type |
| 479 | Junction boxes (Outdoor) |
| 480 | 4 way Welding socket JB, Outdoor |
| 481 | Communication Junction Boxes |
| 482 | Outdoor PA System JB for SpeakersIncoming : 12Px2.5 sq.mm(1 No.) - M40Outgoing : 2Px2.5 sq.mm(12 Nos.) - M25 (9 Nos. Gland + 3 Nos. Plug) |
| 483 | Indoor Telephone System JB (IDF)Incoming : 12Px2.5 sq.mm(1 No.) - M40Outgoing : 2Px2.5 sq.mm(12 Nos.) - M25 (9 Nos. Gland + 3 Nos. Plug) |
| 484 | Junction boxes for Explosive Atmospheres |
| 485 | Junction boxes |
| 486 | 4 way Lighting JB, Ex-d |
| 487 | 5 way JB for small power sockets, Ex-d |
| 488 | 4 way Welding socket JB, Ex-d |
| 489 | For 30 kW Motor with Incoming cable size 1R-3Cx120sq.mm and outgoing cable size 1R-3Cx50sq.mm |
| 490 | For 30 kW Motor with Incoming cable size 1R-3Cx150sq.mm and outgoing cable size 1R-3Cx95sq.mm |
| 491 | For 30 kW Motor with Incoming cable size 1R-3Cx185sq.mm and outgoing cable size 1R-3Cx95sq.mm |
| 492 | For 37 kW Motor with Incoming cable size 1R-3Cx185sq.mm and outgoing cable size 1R-3Cx95sq.mm |
| 493 | For 37 kW Motor with Incoming cable size 1R-3Cx240sq.mm and outgoing cable size 1R-3Cx95sq.mm |
| 494 | For 45kW Motor with Incoming cable size 1R-3Cx240sq.mm and outgoing cable size 1R-3Cx95sq.mm |
| 495 | For 110kW Motor with Incoming cable size 3R-3Cx240sq.mm and outgoing cable size 2R-3Cx240sq.mm |
| 496 | For 132kW Motor with Incoming cable size 4R-3Cx240sq.mm and outgoing cable size 2R-3Cx240sq.mm |
| 497 | Power JB for Instrumentation Benzene Analyser & sulphur analyser :Incoming cable size 1R-2Cx185sq.mm and outgoing cable size 1R-2Cx50sq.mm -GDS Area |
| 498 | Welding Socket JB : 1P25-WJB-0001 , 1P25-WJB-0002, 1P25-WJB-0003Incoming power cable : 1R-4Cx240sq.mmOutgoing power cable : 4R- 4Cx35sq.mm |
| 499 | Communication Junction boxes |
| 500 | Indoor FA System JB for housing addressable module of 1 no. MCPIncoming : 2Px1.5 (1 No.)Outgoing : 2Px1.5 (1 No.), 1Px1.5 (1 Nos.)NPT thread glands : 3 Nos.Plugs : 2 Nos. (Plug for 2Px1.5 size) |
| 501 | Outdoor FA System JB for housing addressable module of 1 no. MCPIncoming : 2Px1.5 (1 No.)Outgoing : 2Px1.5 (1 No.), 1Px1.5 (1 Nos.)NPT thread glands : 3 Nos.Plugs : 2 Nos. (Plug for 2Px1.5 size) |
| 502 | Outdoor FA System JB for housing addressable module of 1 no. Hooter / BeconIncoming : 2Px1.5 (1 No.)Outgoing : 2Px1.5 (1 No.), 1Px2.5 (1 Nos.)NPT thread glands : 3 Nos.Plugs : 2 Nos. (Plug for 2Px1.5 size) |
| 503 | Outdoor FA System JB for housing addressable module of 1 no. DetectorIncoming : 2Px1.5 (1 No.)Outgoing : 2Px1.5 (1 No.), 1Px1.5 (1 Nos.)NPT thread glands : 3 Nos.Plugs : 2 Nos. (Plug for 2Px1.5 size) |
| 504 | Outdoor FA System JB for Housing 2 addressable modules and 2 zener barrierIncoming : 2Px1.5 (1 No.)Outgoing : 2Px1.5 (1 No.), 1Px1.5 (2 Nos.)NPT thread glands : 4 Nos.Plugs : 2 Nos. (Plug for 2Px1.5 size) |
| 505 | Outdoor FA System JB for End of resistor / Fault Isolator in FA loopIncoming : 2Px1.5 (1 No.)Outgoing : 2Px1.5 (1 No.)NPT thread glands : 2 Nos.Plugs : 2 Nos. (Plug for 2Px1.5 size) |
| 506 | Outdoor Telephone System JB (IDF)Incoming : 10Px0.63 mm dia (1 No.)Outgoing : 5Px0.63 mm dia (5 Nos.) NPT thread glands : 6 Nos.Plugs : 3 Nos. (1 No. Plug for 10Px0.63 mm dia & 2 Nos. plugs for 5Px0.63 mm dia) |
| 507 | Outdoor PA System JB for FCSIncoming : 12Px1.5 (1 No.)Outgoing : 2Px1.5 (6 Nos.) NPT thread glands : 7 Nos.Plugs : 2 Nos. (1 No. Plug for 12Px1.5 and 1 No. for 2Px1.5) |
| 508 | Outdoor PA System JB for SpeakersIncoming : 12Px2.5 (1 No.)Outgoing : 2Px2.5 (12 Nos.) NPT thread glands : 13 Nos.Plugs : 3 Nos. (1 No. Plug for 12Px2.5 and 2 Nos. for 2Px2.5) |
| 509 | Indoor PA System JB for SpeakersIncoming : 12Px2.5 (1 No.)Outgoing : 2Px2.5 (12 Nos.) NPT thread glands : 13 Nos.Plugs : 3 Nos. (1 No. Plug for 12Px2.5 and 2 Nos. for 2Px2.5) |
| 510 | Installation Material for Junction boxes (wall / concrete / steel structure mounted) - Supply of all the Installation Material (excluding structural steel) for Junction boxes (wall / concrete / steel structure mounted) as per \"Installation Details - Power\" and applicable construction documents, including any additional material as per site requirement so as to ensure the completeness of installation work- Supply of steel support structure / supporting frames for above shall be considered separately in SECTION - F. |
| 511 | Installation Type : L08A |
| 512 | Installation Type : L08C |
| 513 | Installation Type : P10A |
| 514 | Installation Type : P10B |
| 515 | Installation Type : P10B |
| 516 | Installation Type : P17 |
| 517 | Installation Type : P10A/P10B |
| 518 | POWER SOCKET OUTLETSSupply of various types of power socket outlets and all associated accessories, as per \"ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL\". |
| 519 | Power Socket Outlets for Explosive Atmospheres |
| 520 | For Explosive Atmospheres, 415V, 63A, TPN & E socket outlet, with die cast Al LM6 enclosure, Type WS3 |
| 521 | For Explosive Atmospheres, 415V, 100A, TPN & E socket outlet, with die cast Al LM6 enclosure, Type WS4 |
| 522 | Installation Material for Power socket outlets (wall / concrete / steel structure mounted) - Supply of all the Installation Material (excluding structural steel) for Power socket outlets (wall / concrete / steel structure mounted) as per \"Installation Details - Power\" and applicable construction documents, including any additional material as per site requirement so as to ensure the completeness of installation work- Supply of steel support structure / supporting frames for above shall be considered separately in SECTION - F. |
| 523 | Installation Type : P10A (63A) On Concrete |
| 524 | Installation Type : P10A (63A) On Steel |
| 525 | Installation Type : P10B (63A) On Steel |
| 526 | Installation Type : P15 (63A) |
| 527 | Installation Type : P10A (100A) on Concrete |
| 528 | Installation Type : P10A (100A) on Steel |
| 529 | Installation Type : P10B (100A) on Steel |
| 530 | FIRE ALARM AND COMMUNICATION SYSTEMS |
| 531 | FIRE ALARM (FA) SYSTEM- Supply of all the Installation Material (excluding structural steel) for FA system equipment and associated accessories as per applicable construction documents, including any additional material as per site requirement so as to ensure the completeness of installation work- Supply of steel support structure / supporting frames for above shall be considered separately in SECTION - F. |
| 532 | FA system accessories (Industrial / For Explosive Atmospheres) |
| 533 | Installation Type: FAHC1 |
| 534 | Installation Type: FAHS1 |
| 535 | Installation Type: FASC1 |
| 536 | Installation Type: FASC2 |
| 537 | Installation Type: FASS1 |
| 538 | Installation Type: FCPC1 |
| 539 | Installation Type: FCPP1 |
| 540 | Installation Type: FCPP2 |
| 541 | Installation Type: FCPR1 |
| 542 | Installation Type: FCPS1 |
| 543 | Installation Type: FMDC1 |
| 544 | Installation Type: FMDF3 |
| 545 | Installation Type: FMDS1 |
| 546 | Installation Type: FCPS2 |
| 547 | Installation Type: CFBC1 |
| 548 | Installation Type: CFBS1 |
| 549 | Junction boxesInstallation shall be as per \"Installation Details - Lighting\" and applicable construction documents. |
| 550 | Installation Type: L08C |
| 551 | PUBLIC ADDRESS (PA) SYSTEM- Supply of all the Installation Material (excluding structural steel) for PA system equipment and associated accessories as per \"Installation standards- Communication & PA System\" and applicable construction documents, including any additional material as per site requirement so as to ensure the completeness of installation work- Supply of steel support structure / supporting frames for above shall be considered separately in SECTION - F. |
| 552 | PA system accessories (For Industrial / Explosive Atmospheres) |
| 553 | Installation Type: CTFC2 |
| 554 | Installation Type: CTFR1 |
| 555 | Installation Type: CTFR2 |
| 556 | Installation Type: CTFS2 |
| 557 | Installation Type: CTFS3 |
| 558 | Installation Type: CFBR1 |
| 559 | Installation Type: CFBS1 |
| 560 | Installation Type: CSPKP1 |
| 561 | Installation Type: CSPKS1 |
| 562 | Installation Type: CSPKR1 |
| 563 | Installation Type: CMCS1 |
| 564 | Junction boxesInstallation shall be as per \"Installation Details - Lighting\" and applicable construction documents. |
| 565 | Installation Type: L08B |
| 566 | Installation Type: L08C |
| 567 | Installation Type: L08D |
| 568 | Installation Type: L08F |
| 569 | TELEPHONE SYSTEMSupply of all the Installation Material (excluding structural steel) for Telephone system equipment and associated accessories as per \"Installation standards- Communication & PA System\" and applicable construction documents, including any additional material as per site requirement so as to ensure the completeness of installation work |
| 570 | Telephone system accessories (For Industrial / Explosive Atmospheres) |
| 571 | Installation Type: CTFC1 |
| 572 | Installation Type: CTFC2 |
| 573 | Installation Type: CTFR1 |
| 574 | Installation Type: CTFR2 |
| 575 | Installation Type: CTFS1 |
| 576 | Installation Type: CTFS2 |
| 577 | Installation Type: CTFS3 |
| 578 | Installation Type: CTFC3 |
| 579 | Installation Type: CFBC1 |
| 580 | Installation Type: CFBS1 |
| 581 | Installation Type: CSPKC1 |
| 582 | Installation Type: CSPKS1 |
| 583 | Junction boxesInstallation shall be as per \"Installation Details - Lighting\" and applicable construction documents. |
| 584 | Installation Type: L08B |
| 585 | CCTV SYSTEMSupply of all the Installation Material (excluding structural steel) for CCTV system equipment and associated accessories as per \"Installation standards- Communication & PA System\" and applicable construction documents, including any additional material as per site requirement so as to ensure the completeness of installation work |
| 586 | CCTV system accessories (For Industrial / Explosive Atmospheres) |
| 587 | Installation Type: CTVS1 |
| 588 | Junction boxesInstallation shall be as per \"Installation Details - Lighting\" and applicable construction documents. |
| 589 | Installation Type: L08C |
| 590 | Installation Type: L08G |
| 591 | EARTHING AND LIGHTNING PROTECTION |
| 592 | EARTHING MATERIAL |
| 593 | Earthing conductor Supply of GI strip / bare copper conductor for earthing |
| 594 | 50 x 6 mm GI strip |
| 595 | 75 x 10 mm GI strip |
| 596 | 8 SWG SOLID G.I. WIRE |
| 597 | 10 MM (3/8\") DIA G.I WIRE ROPE |
| 598 | 16 MM (5/8\") DIA G.I WIRE ROPE |
| 599 | 1C x 95 Sq.mm Cu Cable |
| 600 | 1C x 10 Sq.mm Cu Cable |
| 601 | Earth / lightning protection electrodesSupply of Earth / lightning protection electrodes along with the associated accessories / material as per \"Installation Details - Earthing\", including any additional hardware as per site requirement so as to ensure the completeness of installation work |
| 602 | Installation Type : E01A :100 mm Dia, 3 m length GI pipe earth electrode for Electrical Safety earth |
| 603 | Installation Type : E01B : 100 mm Dia, 6 m length GI pipe earth electrode for Instrument clean earth |
| 604 | Installation Type : E01A : 100 mm Dia, 3 m length GI pipe lightning protection electrode |
| 605 | Earth buses- Supply of Earth buses along with the associated accessories (excluding structural steel) as per \"Installation Details - Earthing\" and applicable construction documents, including any additional material as per site requirement so as to ensure the completeness of installation work- Supply of steel support structure / supporting frames for above shall be considered separately in SECTION - F. |
| 606 | Installation Type : E02A GI earth bus for Electrical safety |
| 607 | Installation Type : E02B - GI earth bus for instruments |
| 608 | Installation Type : E20 - Mounted on cable tray for Electrical |
| 609 | Installation Type : E20 - Mounted on cable tray for Instrumentation |
| 610 | LIGHTNING PROTECTION MATERIAL |
| 611 | Lightning protection conductor - Supply of GI strip / bare copper conductor/aluminium/HDGI Round conductor for Lightning protection and associated accessories- Supply of accessories such as test links, cross connectors, parallel connectors for lightning protection down conductors, epoxy insulator supports and the associated accessories as per\"Installation Details - Lightning Protection\" / as indicated in applicable construction documents / as per the site requirement, are considered in running meter length oflightning protection down conductors. |
| 612 | Installation Type: E16 Roof Conductor (Conductor Size- 25x6mm) |
| 613 | Installation Type: E16 Down Conductor (Conductor Size- 25x6mm) |
| 614 | Test Link : E16 : 50x6mm GI Link 150mm Long |
| 615 | STRUCTURAL STEEL- Supply of structural steel- The quantity of structural steel indicated below is matching with the quantity of steel indicated in SECTION-F of doc. \"BILL OF QUANTITIES -INSTALLATION (ELECTRICAL)\". - Section wise requirement shall be estimated by CONTRACTOR, as per the applicable construction documents / various applicable \"Installation Details\" mentioned in \"SECTIONS - A to E\" in this document.- Measurement of steel quantity for installation shall be based on actual quantities installed at site without wastage allowance. |
| 616 | Structural steel (MS)Supply of coating material and paint as required for surface preparation and painting of steel shall be as per doc. TP-1ZZZA-PI-SPE-0003 (Technical Specification for Painting) is included in scope. |
| 617 | Structural steel (Hot deep galvanized GI) |
| 618 | MISCELLANEOUS ITEMS |
| 619 | CANOPIES- Supply of GI / FRP canopies for various equipment and all associated accessories, as per \"ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL\".- Site visit as required to confirm the actual dimensions / arrangement of various equipment installed at site, so as to fabricate canopy exactly suitable for the equipment is considered in the scope.- Supply of all the Installation Material (including steel supporting frame as required) required as per site requirement is included in the scope. |
| 620 | Canopies for Motors |
| 621 | GI canopy complete with louvers backed up by wire mesh |
| 622 | Upto 3.0 kW |
| 623 | 3.7 kW to 15 kW |
| 624 | 18.5 kW to 37.0 kW |
| 625 | 45.0 kW to 90 kW |
| 626 | 110 kW to160 kW |
| 627 | HV (6.6kV) Motors |
| 628 | 200 kW |
| 629 | 730 kW |
| 630 | CIVIL WORK |
| 631 | Anchor fasteners- Supply of anchor fasteners for supporting various equipment in brick work / concrete work, as per \"ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL\".- Supply of anchor fasteners indicated below excludes those already considered in various \"Installation Details\" mentioned in \"SECTIONS - A to E\" in this document. |
| 632 | Anchor fasteners M8 type x 60mm |
| 633 | Anchor fasteners M10 type x 75 mm |
| 634 | Anchor fasteners M12 type x 100 mm |
| 635 | Supply of certified soft sand of known resistivity, red coloured concrete tiles of appropriate voltage grade for cable protection, ordinary bricks, warning tapes, cable markers (including steel & RFID tag) |
| 636 | Certified soil (soil resistivity 150 0C/cm/W)) |
| 637 | SAFETY ITEMSSupply of safety items as per applicable statutory requirements / HSE documents / as indicated in applicable construction documentsALL SAFETY ITEMS SHALL BE OF REPUTED MAKE & SHALL HAVE PROVENPAST TRACK RECORD. LOCAL MAKES ARE NOT ACCEPTABLE |
| 638 | Fire proof painting for cables for 3 m length at entry points of both ends |