Medium Voltage Power, Control And Lighting Cables For Gds, Pfcc Unit For Nrep Supply Of Medium Voltage Power, Control And Lighting Cables For Gds, Pfcc Unit For Nrep As Per Technical Specifications For Numaligarh Refinery Limited, Assam, India , Supply Of Mv Cables As Specified In Mr Including Design, Engineering, Manufacturing, Inspection, Factory Acceptance Testing (Fat), Supply, Dispatch Of Medium Voltage Cables. , Group 1 :- Supply Of Powercables For Pfcc/ Lpgtu2/ Gds/ Pru Unit For Nrep Project Stranded Aluminium Conductor, Extruded Xlpe Insulation, Extruded Pvc Inner Sheath, Armoured, Overall Pvc Outer Sheath (Frls) , 3C X 35Sq. Mm (A2xfy) , 3C X 50Sq. Mm (A2xfy) , 3C X 70Sq. Mm (A2xfy) , 3C X 95Sq. Mm (A2xfy) , 3C X 120Sq. Mm (A2xfy) , 3C X 150Sq. Mm (A2xfy) , 3C X 185Sq. Mm (A2xfy) , 3C X 240Sq. Mm (A2xfy) , 3C X 300Sq. Mm (A2xfy) , 4C X 25Sq. Mm (A2xfy) , 4C X 35Sq. Mm (A2xfy) , 4C X 50Sq. Mm (A2xfy) , 4C X 70Sq. Mm (A2xfy) , 4C X 95Sq. Mm (A2xfy) , 4C X 120Sq. Mm (A2xfy) , 4C X 150Sq. Mm (A2xfy) , 4C X 185Sq. Mm (A2xfy) , 4C X 240Sq. Mm (A2xfy) , 4C X 300Sq. Mm (A2xfy) , 1C X 630Sq. Mm (A2xway) , Group 2 :- Supply Of Powercables: (For Movs) For Pfcc/ Lpgtu2/ Gds/ Pru Unit For Nrep Project Fire Survival Cable, Stranded Copper, Epr Insulated Or Equivalent Material With Glass Mica Tape Insulation,Armoured, Inner And Outer Sheath As Per Relevant Iec Standards , 4C X 4Sq. Mm (2Xwy) , 4C X 10Sq. Mm (2Xwy) , Group 3 :- Supply Of Control Cables: For Pfcc/ Lpgtu2/ Gds/ Pru Unit For Nrep Project Stranded Copper Conductor, Extruded Xlpe Insulation, Extruded Pvc Inner Sheath, Armoured, Overall Pvc Outer Sheath (Frls) , 3C X 2.5Sq. Mm (2Xwy) , 3C X 4Sq. Mm (2Xwy) , 3C X 6 Sq. Mm (2Xwy) , 3C X 10Sq. Mm (2Xwy) , 3C X 16 Sq. Mm (2Xfy) , 3C X 50 Sq. Mm (2Xfy) , 3C X 70 Sq. Mm (2Xfy) , 3C X 120 Sq. Mm (2Xfy) , 3C X 150 Sq. Mm (2Xfy) , 3C X 185 Sq. Mm (2Xfy) , 3C X 240 Sq. Mm (2Xfy) , 3C X 300 Sq. Mm (2Xfy) , 4C X 4Sq. Mm (2Xwy) , 4C X 10Sq. Mm (2Xwy) , 5C X 2.5 Sq. Mm (2Xwy) , 8C X 2.5 Sq. Mm (2Xwy) , 10C X 2.5 Sq. Mm (2Xwy) , 12C X 2.5 Sq. Mm (2Xwy) , 16C X 2.5 Sq. Mm (2Xwy) , Group 4 :- Supply Of Lighting Cables: For Pfcc/ Lpgtu2/ Gds/ Pru Unit For Nrep Project Stranded Copper Conductor, Extruded Xlpe Insulation, Extruded Pvc Inner Sheath, Armoured, Overall Pvc Outer Sheath (Frls) , 3C X 2.5Sq. Mm (2Xwy) , 3C X 4Sq. Mm (2Xwy) , Group 5 :- Supply Of Earthing Cables For Pfcc/ Lpgtu2/ Gds/ Pru Unit For Nrep Project Flexible Stranded Copper Conductor, (Pvc, Frls) Unarmoured , 1C X 6Sq. Mm (Green With Yellow Stripes) , 1C X 120Sq. Mm (Pe Conductor) , 1C X 150 Sq. Mm (Green) => Limited