| 1 | Taking out wind ties from roof including cutting out rusted bolts, nuts etc. and removing materials to any distance within compound and stacking. |
| 2 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 3 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in charge ,Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 4 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of : Asbestos Cement Sheet |
| 5 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of : G.S. Sheet |
| 6 | Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. |
| 7 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes. |
| 8 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes(labours only employed) |
| 9 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 10 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) |
| 11 | 15 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) |
| 12 | 20 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) |
| 13 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS : 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling / self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 14 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm) |
| 15 | Fixing of old wind tie with new fittings including painting two or more coats with anticorrosive bitumastic paint of approved brand & manufacturer over and including priming coat of ready mixed zinc chromate yellow primer of approved brand. |
| 16 | Extra for providing and fixing wind ties of 40x 6 mm flat iron section. |
| 17 | Supplying and installation testing and commissioning of turboventilator size 22\"\" stainless steel 430 grade approximate weight 4.85 kg. The ventilator should have air absorption of 7km/hr,2240CFM with blade length 369m, wings of 80 mm ,outer wings 22\"\"-24 nos.inner wings 22\"\"-6nos,with self lubricating ball bearing etc.complete as per manufactures specification andstainless steel base plate etc as per direction of Engineer-in charge including cutting pre coated sheet. |
| 18 | Supplying and fixing 3 mm thick translucent white acrylic plastic sheet to suit semi-corrogated sheet roofing made from thermo setting polyster resin fiber reinforced as per ISI 2866 - 1989 to suit fully corrogated AC sheet roofing overlapping on corrogation and with light transmission not less than 80% including self tapping screws EPDM sealand washer complete as per direction of Engineer-in-charge |
| 19 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase |
| 20 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work |
| 21 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 22 | Finishing walls with water proofing cement paint of required shade New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 23 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 24 | Finishing walls with water proofing cement paint of required shade :Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 litrs/10 sqm complete including cost of Priming coat. |
| 25 | Deduction on the account of salvage value. Disposal and dismantling unserviceable materials(a) ACC Sheet |
| 26 | (b) G.S Sheet |
| 27 | (c)J or L hooks |
| 28 | (d) Dismantled rain water 15.00cm OD (Bunda) Pipes |
| 29 | (e) Dismantled 65L Pipes from purlin |
| 30 | Dismantling bunda or C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead :150 mm dia pipe |
| 31 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 32 | Removing mortar from bricks in cement mortar and cleaning bricks including stacking within a lead of 50 M (stacks of cleaned bricks shall be measured); |
| 33 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) : free supply of bricks |