Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Site Clearance and Dismantling Works |
| 2 | Carefull shifting of records and racks to safe place as per the directions of engineer-in-charge. |
| 3 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and belowDSR 15.12.1 |
| 4 | Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge.DSR 15.19 |
| 5 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mmDSR 15.23.1 |
| 6 | Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead : Thickness above 25 mm up to 40 mmDSR 15.39.3 |
| 7 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. completeDSR 13.88 |
| 8 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortarDSR 15.7.4 |
| 9 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-incharge.DSR 15.57 |
| 10 | Labour charge for dismantling of sanitary installations like wash basin, urinal, etc. (3 No for 2 days) |
| 11 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China)including stacking of useful materials near the site and disposal ofunserviceable materials within 50 metres lead.DSR 15.52 |
| 12 | Removal of old wiring |
| 13 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.DSR 15.60 |
| 14 | Interior Works |
| 15 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)DSR 6.13.2 |
| 16 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineerin- Charge. With cement mortar 1:4 (1 cement : 4 fine sand)DSR 14.1.1 |
| 17 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.DSR 13.80 |
| 18 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primerDSR 13.41.1 |
| 19 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi chambered frame, sash and mullion/coupler (where ever required)extruded profiles having minimum wall thickness of .70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367: Part 1 To 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash 7 mullion (if required) shall be mitred cut and fusion welded/ mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rof of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-charge. |
| 20 | Wire mesh/ Glazing of plain/ toughened/ laminated/ double glass unit with/ without high performance coatings as per design requirements and conforming to IS: 3548 & IS16231 shall be paid separately.Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for: (i) Sites with basic wind speed>45 m/sec as per IS 875-Part 3 (ii) Sites with structure height more than 20m for all wind speeds9.147.A4. Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.Using R3 series with frame (98 mm & above) x (40 mm & above) & both glazed and fly screen sash (30 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Heigh above 1.8 m)DSR 9.147.A4.2 |
| 21 | Toughened glass 12 mm thicknessDSR 8778 |
| 22 | Stainless steel wire guage (Grade-304) aperture 1.4 mm and0.50mm dia wireDSR 8737 |
| 23 | Weather Silicon sealantDSR 8646 |
| 24 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6mm reveal profile (white/black),comprising of main-T runners of size 15x42mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.With 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tilesDSR 26.23.1 |
| 25 | Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete.DSR 8.6 |
| 26 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thickDSR 11.26.1 |
| 27 | Providing and fixing internal wall panels on Light gauge steel frame work with 12.5 mm thick gypsum plaster board conforming IS 2095:2011 fixed on cement board as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60 cm c/c of approved make, Screws shall be of counter sunk rib head of 1.60 mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. Proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately). Cement Bonded particle board 8 mm (Termite, Fire & Moisture Resistance), as per IS:14276 : 1995 |
| 28 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.DSR 9.121 |
| 29 | 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-incharge.DSR 9.122.2 |
| 30 | Providing and fixing 18mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. in partitions, boxes, shelves, racks and cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge (Note: Fittings to be paid separately). 18 mm thickDSR 9.166.1 |
| 31 | Providing and fixing 6mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. on the backing of racks, drawer, cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-incharge.DSR 9.167 |
| 32 | Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge.(Payment of providing and fixing auto closing hinges shall be paid separately)DSR 9.168 |
| 33 | Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. 200mmDSR 9.170.1 |
| 34 | Providing and fixing concealed hinge of approved quality for 19-20mm thick door with stainless steel screws complete :DSR 26.11 |
| 35 | Washroom Upgradation |
| 36 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).DSR 5.3 |
| 37 | Providing and laying PCC 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)DSR 4.1.8 |
| 38 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmDSR 11.41.2 |
| 39 | Tile work in skirting, risers of steps and dado up to 2 m height over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm, including pointing in white cement mixed with pigment of matching shade complete.DSr 11.22 |
| 40 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.DSR 17.31 |
| 41 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidDSR 17.2.1 |
| 42 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever requiredOne urinal basin with 5 litre white PVC automatic flushing cisternDSR 17.4.1 |
| 43 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapDSR 17.7.2 |
| 44 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - chargeDSR 17.16A |
| 45 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.DSR 17.28 |
| 46 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high glossfinish etc. complete at all levels.Granite stone slab of all colour and texture except black, Cherry/Ruby redArea of slab over 0.50 sqmDSR 8.2.3.2 |
| 47 | Mobile Storage Compactors |
| 48 | Make: GodrejMain Body:(a) Construction:Rigid Knock Down construction made of 0.8 thk. CRCA Steel conforming to IS: 513 Gr.D. Each body block consists of 1 Main unit & then Add-on units (0, 1,2,3 depending on no. of bays 1, 2, 3, 4 respectively). Each unit has 5 loading levels formed by 4 nos. adjustable shelves for 1980 Height body and 6 loading levels with 5 nos. adjustable shelves for 2361 Height body.Body units are mounted on an understructure which is fixed or moving.The body comprises the following components: |
| 49 | 1. Front Cover: It is the foremost panel of the body on which the handles (Push pull)/ Drive unit (Drive Type) are fixed. It is made of 0.8 thk. CRCA Steel conforming to IS: 513 Gr.D. The front cover has a pattern of holes on the front surface for ventilation purpose.2. Back Cover: It is the backmost panel of the body and is the mirror image of the front cover. It is made of 0.8 thk. CRCA Steel conforming to IS: 513 Gr.D. The back cover has a pattern of holes on the surface for ventilation purpose.3. Back Panel: The back panels are made of 0.6 thk. CRCA Steel conforming to IS: 513 Gr.D. There are two back panels – Top back panel and Bottom back panel for 1980H unit as well as 2361H unit. The two back panels are fixed together using machine screws. The purpose of the back panel is to act as a divider between 2 opposite shelves in twin body (TM/TD). When the entire optimizer layout is locked it also prevents access to inside files from the outside in case of single body (SS/SD/SL/LD).4. Shared Panel: The shared panel acts as a partition between two adjacent bodies. It is made of 0.8 thk. CRCA Steel conforming to IS: 513 Gr.D.5. Door Frame: The door frame assembly is made of 2 vertical door stiffeners, a top horizontal stiffener and a bottom horizontal stiffener. It provides rigidity to the entire body as the topmost shelf is pop riveted with the back panel as well as both the vertical door frame. The door frame is also useful if the customer chooses to have doors for the optimizer as the doors are hinged about the door frame. It is made of 0.8 thk. CRCA Steel conforming to IS: 513 Gr.D.6. Tie rod assembly: The tie rod assembly acts as a substitute to the back panels (only in twin body) if the customer chooses to not have back panels. The assembly consists of 2 tie rods, 4 fixing brackets and 2 turnbuckles. The tie rods are fixed in a shape of ‘X’ between two opposite shelves. The tie rods are made of 4mm diameter rods of MS while the fixing brackets are made of 2mm thk. CRCA Steel conforming to IS: 513 Gr.D. This assembly is available for both heights – 1980H and 2361H |
| 50 | Height for Push Pull Optimizer:Optimizer Height from ground is 2080 mm (1980 body + 65 undercarriage + 61.5 channel system).Height for Drive Type Optimizer:Optimizer Height for ground for 1980H body is 2121.5mm (1980 body + 80 understructure + 61.5 channel system).Optimizer Height for ground for 2361H body is 2502.5mm (2361 body + 80 understructure + 61.5 channel system). |
| 51 | Finish:The bodies including shelves are given antirust surface treatment & are coated with epoxy polyester powder. It involves an 8-step treatment consisting of Hot water rinse, Knock of degreasing, degreasing, cold water rinse, phosphating, cold water rinse, and passivation & dry off oven treatment. Final finish consists of epoxy polyester powder coating of approved color & shade with a Dry Film Thickness of minimum 40 microns. The testing of paint is done for various physical & chemical properties as per IS: 101. The material is then oven baked with a controlled temperature of 180 deg.C to 200 deg.C. |
| 52 | Shelf:(a) Construction:It is made of 0.7 thk CRCA steel conforming to IS: 513 Gr.D or DD. Its max load bearing capacity is 100 Kg uniformly distributed per shelf. For P1 and P2 type of Configuration recommended shelf load is less than 100kg (Refer UDL chart below). This is done to ensure that the unit is light enough for one person to pull/push with a handle even at recommended full load capacity. Shelf can be placed at clear height of 386mm from bottom in everybody. The last loading level for shelf is 1721mm from ground level for 1980H body and 2107mm from ground for 2361H body.Shelves are mounted on support brackets & shelf level can be adjusted at approx. 25.4 pitches. There are 4 adjustable shelves per body for 1980H and 5 adjustable shelves per body for 2361H, giving 5 and 6 loading levels for 1980H and 2361H body respectively.(b) Storage capacity per shelf:The shelf is 1180mm in length and can hold up to 13 nos. of box files of size 85mm x 345mm x 285mm. |
| 53 | Understructure:(a) Construction:Push Pull Understructure:-The Understructure is a welded frame suitably fabricated to bear the loads based on configuration. The frame consists of the following parts: Main channel, body-fixing channel, body-fixing angle and bearing-fixing angle. All the components are made of CRCA sheet 2 mm thk conforming to IS:513.Drive Type Understructure:-The Understructure is a welded frame suitably fabricated to bear the loads based on configuration. The frame consists of the following parts: Main channel, body-fixing channel, U-channel and Z-channel. All the components are made of HR sheet 3 mm thk. conforming to IS:2062.(b) Size:Sizes of Understructure:Push Pull OptimizerSingle Static / Single Last – 1200 x (no. of bays)X 396 (Depth) X 65 (Height)Twin Mobile - 1200 x (no. of bays)X 796 (Depth) X 65 (Height)Drive Type OptimizerStatic Drive / Last Drive – 1200 x (no. of bays)X 396 (Depth) X 80 (Height)Twin Drive - 1200 x (no. of bays) X 796 (Depth) X 80 (Height)Refer Table 3 for dimensions as per number of bays.External Load carrying capacity per understructure -PUSH-PULL/ MANUAL TYPE (Configuration – TYPE P1) - 600 Kg. MaximumPUSH-PULL/ MANUAL TYPE (Configuration – TYPE P2) - 600 Kg. MaximumDRIVE TYPE (Configuration - TYPE D2) - 2400 Kg. Maximum.DRIVE TYPE (Configuration – Type D3) – 3600 Kg Maximum.DRIVE TYPE (Configuration – Type D4) - 4800 Kg Maximum.(c) Finish:The understructure, after pre-treatment, is coated with final finish consisting of epoxy polyester powder coat of approved color & shade with a Dry Film Thickness of minimum 40 microns. |
| 54 | Movements of the System:Push-Pull Configuration (TYPE-P1/TYPE-P2): Movement of units achieved by pushing or pulling a pair of ‘C type plastic handles’ (mounted on SL & TM units). These handles are rigidly fixed at an ergonomically suitable height on side of each moving body. Each movable body also has an understructure with 4 nos. of antifriction ball bearings for rolling on channels. The twin moving body, i.e. TM, has 4 nos. of bearing fitted horizontally to restrict the lateral movement of the body on rail while the single moving body, i.e. SL, body has 2 nos. of a special anti-tilt bearing assembly fitted to the understructure which not only restricts lateral movement but also prevents SL from toppling.Drive Type Configuration (TYPE-D2/TYPE-D3/TYPE- D4): In case of drive type movement of units is achieved by rotating a PU hand wheel. The hand wheel comprises of a welded metal frame which is then covered by PU using insert-molding process. The metal frame is made of 3 mm thk. HR conforming to IS:2062.The handwheel is connected to the rollers through a ‘Sprocket-Chain’ arrangement mounted on the side of the body. For D3 & D4 type of configurations, the ‘sprocket-chain’ arrangement is replaced by a 2-stage ‘sprocket-chain’ arrangement to accommodate higher weights of the bodies.For D2, each movable understructure is provided with 4 rollers of which 2 are driving and 2 are driven. The driving rollers are connected to the sprocket-chain arrangement through a connector tube. Through this assembly the input from handwheel is transferred to the driving rollers which then move the entire unit along the rails. On LD understructure additional 2 nos. of a special anti-tilt bearing assembly is fitted to the understructure. This prevents lateral movement as well as tilting of body.Similarly, for D3 each movable understructure has 3 driving rollers and 3 driven rollers. LD understructure has 2 nos. of anti-tilt bearing assembly.For D4 each movable understructure has 4 driving rollers and 4 driven rollers. LD understructure has 2 nos. of anti-tilt bearing assembly.The roller assembly comprises of a die-cast step wheel, 2 deep-groove ball bearings and a MS shaft. The step wheel is made of cast steel and is fitted onto the MS shaft using a feather key. The two ball bearings are then fastened on either side of the step wheel using circlips. This entire roller assembly is then snap-fitted into a wheel housing. The wheel housing is fixed in the U-channel of the understructure using machine screws. This wheel-housing is made of engineering plastic material made by injection-molding process. The entire roller assembly is designed to withstand the maximum loads of the body.The ‘sprocket-chain’ arrangement is covered by a 1 mm thk. CRCA sheet Drive Unit Cover with dimensions 1202mm x 398mm x 87mm and is fixed onto the side of the body. The PU handwheel is rigidly fixed at suitable height on side of the body & projects out of cover by another 99.0 mm. Fixed unit (SD) does not have the Drive Unit Cover. |
| 55 | Fittings:(a) Push Pull Optimizer Centralized Locking:A Centralized locking arrangement is provided through Locking Stiffener mounted onto back of Single Last unit, i.e. SL body. It gets locked into the channels when all the units are brought together, and the lock is turned. The Recess handle lock is of Godrej make & placed at a height of 940mm from ground level. The locking stiffener is made of 1.2 mm thk conforming to IS:513.(b) Drive Type Optimizer Centralized Locking:Each Drive type unit has a Locking Knob near the Drive wheel for manual locking of individual units when a person is using those units. This prevents other users from accidently moving units while someone is inside. Knob should be rotated to unlock position when units are to be moved again.A centralized locking arrangement is also provided on drive unit cover. A cam lock and lever arrangement is fitted on the drive unit cover of the last movable body, i.e. (LD). After all bodies are brought together, the bodies are locked using their respective knobs. The cam lock is then turned to lock position. This locked cam lock ensures that the knob of the last body remains in the locked position unless the cam lock is unlocked. This in turn ensures that the entire layout remains locked.When the last Body is Twin Drive, i.e. TD, hinged doors are provided for the last body. In this scenario the centralized locking system is fitted on the drive unit cover of the last TD body.(b)Door Locking / handle:Hinged doors have Recessed Die cast Handle cum lock with 3 way locking through a lever & shooting bolts.(c) Fasteners:The nuts & bolts are galvanized / blackodized / Zn Plated.(d) Rail Channels (for Push-pull and Drive type with no platform):It consists of ‘C’ section 2 mm thk HR sheet & Square 25.4mm X 2mm thk ERW tube – both connected by screws. Prior to the grouting of the guide channels with the help of raul plug & screw, ensure the ground is level. The rail channels are of 3 lengths i.e., 800mm, 1600mm and 2400mm.Connection of rail channels: The requirement of rail channels depends on the number of rows of bodies. In any configuration there is only one fixed body (SS/SD). There will be only one movable single body (SM/LD) or no movable single body depending on the layout. The number of twin bodies (TM/TD) depends on the layout and customer. In case of any layout there will always be one 2400mm long rail channel. The 800mm and 1600mm rail channels are connected to the 2400mm rail channel, depending on number of rows. The 2400mm rail channel is connected to 800mm/1600mm rail channel using a Square 19.1mm X 2mm thk ERW tube. This tube is connected to both channels using screws from bottom side.Rail Logic: For each body in the bay there is a corresponding rail. So P1/P2/D2 configuration has 2 rails, D3 configuration has 3 rails and D4 has 4 rails. |
| 56 | (e) Label Holder:It is an aluminium extrusion of length 396mm for LD/SD and 796mm for TD, fitted on to front cover of body. The Paper is 300GSM matt milky white sticker paper, to be inserted into the aluminium extrusion. The length of paper is 394mm for LD/SD and 794mm for TD. Over that a transparent plastic of corresponding length of 150-200 micron polythene is to be inserted.(g) Platform option (for drive type only): A Platform option is also provided for drive type optimizer along with Rail channel arrangement. The platform consists of Rail Extrusion which is a thick extrusion on which Rail MS bright bar of sq 25.4mm is firmly fixed from bottom using counter sunk screws. This Rail extrusion arrangement has 3 lengths similar to Rail channel i.e., 800mm, 1600mm and 2400mm.Connection of rail extrusions: The requirement of rail extrusions is same as that of the rail channels. The connection of rail extrusions is done using a metal strip which is screwed on the side of the 2400mm rail extrusion bright bar and 800mm/1600mm rail extrusion bright bar, using CSK screws. The metal strip is made of HR sheet 3 mm thk. conforming to IS:2062.Rail Logic: For each body in the bay there is a corresponding rail. So D2 configuration has 2 rails, D3 configuration has 3 rails and D4 has 4 rails.The platform has wire extrusion with snap cover and a slope extrusion on either side of the platform. It also has 3 lengths similar to the rail extrusion. There are MDF panels of 25mm thickness with 1mm Merino Laminate (AC 3 GRADE 40499 SUEDE), which are placed between the extrusions based on the layout. The AC 3 grade ensures resistance to abrasion caused by moderate to heavy footfall.The logic for platform panels booking is shared in a separate excel file. The logic shared is only up to a configuration for 1LD + 1SD + 6TD. For a layout bigger than that the wooden panels are to be booked through APO. This is applicable only for platform panels and not for rail extrusions.(h) Aisle Space:Ensure a clear aisle space on the Handle / Drive Wheel side of the Optimizer layout is at least 780mm. For comfortable access of items stored in the optimizer, ensure adjacent units can be rolled apart at least 780mm.(i) WeightsDead Weight of the system: (These are Nominal Weights. The Exact Weights may differ slightly. This is Only for Internal Purpose from Loading Point of view)(Total external load & dead weight is spread on 2/3/4 channels placed at a distance apart) |
| 57 | OPTIMIZER PLUS-DRIVE TYPE |
| 58 | Optz Plus SD2 |
| 59 | Optz Plus LD2 |
| 60 | Optz Plus TD2 Solid back panel |
| 61 | (1200W, 400D,2361H) |
| 62 | CHANNELS (RAILS) |
| 63 | Optz Plus D2 CHNL 2400mm |
| 64 | OPTIMIZER PLUS-DRIVE TYPE |
| 65 | Optz Plus SD2 |
| 66 | Optz Plus TD2 Solid back panel |
| 67 | (1200W, 400D, 2361H) |
| 68 | Optz Plus Hinge door Pair 1200mm 2361mm PS |
| 69 | CHANNELS (RAILS) |
| 70 | Optz Plus D2 CHNL 2400mm |
| 71 | Optz Plus D2 CHNL 800mm |
| 72 | OPTIMIZER PLUS-DRIVE TYPE |
| 73 | Optz Plus SD2 |
| 74 | Optz Plus TD2 Solid back panel |
| 75 | (1200W, 400D, 2361H) |
| 76 | Optz Plus Hinge door Pair 1200mm 2361mm PS |
| 77 | CHANNELS (RAILS) |
| 78 | Optz Plus D2 CHNL 2400mm |
| 79 | Optz Plus D2 CHNL 800mm |
| 80 | OPTIMIZER PLUS-DRIVE TYPE |
| 81 | Optz Plus SD2 |
| 82 | Optz Plus TD2 Solid back panel |
| 83 | (1200W, 400D, 2361H) |
| 84 | CHANNELS (RAILS) |
| 85 | Optz Plus Hinge door Pair 1200mm 2361mm PS |
| 86 | Optz Plus D2 CHNL 2400mm |
| 87 | Optz Plus D2 CHNL 800mm |
| 88 | OPTIMIZER PLUS-DRIVE TYPE |
| 89 | Optz Plus SD2 |
| 90 | Optz Plus TD2 Solid back panel |
| 91 | (1200W, 400D, 2361H) |
| 92 | CHANNELS (RAILS) |
| 93 | Optz Plus D2 CHNL 2400mm |
| 94 | Optz Plus D2 CHNL 800mm |
| 95 | OPTIMIZER PLUS-DRIVE TYPE |
| 96 | Optz Plus SD2 |
| 97 | Optz Plus LD2 |
| 98 | Optz Plus TD2 Solid back panel |
| 99 | (1200W, 400D, 2361H) |
| 100 | CHANNELS (RAILS) |
| 101 | Optz Plus D2 CHNL 2400mm |
| 102 | Optz Plus D2 CHNL 1600mm |
| 103 | Optz Plus D2 CHNL 800mm |
| 104 | OPTIMIZER PLUS-DRIVE TYPE |
| 105 | 2 Bay Drive Type 1050 SD2 |
| 106 | 2 Bay Drive Type 1050 LD2 |
| 107 | 2 Bay Drive Type 1050 TD2 |
| 108 | 1050W X 400D X 2361H |
| 109 | CHANNELS (RAILS) |
| 110 | Optz Plus D2 CHNL 2400mm |
| 111 | Optz Plus D2 CHNL 800mm |
| 112 | OPTIMIZER PLUS-DRIVE TYPE |
| 113 | 2 Bay Drive Type 1050 SD2 |
| 114 | 2 Bay Drive Type 1050 LD2 |
| 115 | 2 Bay Drive Type 1050 TD2 |
| 116 | 1050W X 400D X 2361H |
| 117 | CHANNELS (RAILS) |
| 118 | Optz Plus D2 CHNL 2400mm |
| 119 | Optz Plus D2 CHNL 1600mm |
| 120 | Optz Plus D2 CHNL 800mm |
| 121 | OPTIMIZER PLUS-DRIVE TYPE |
| 122 | 2 Bay Drive Type 1050 SD2 |
| 123 | 2 Bay Drive Type 1050 LD2 |
| 124 | 2 Bay Drive Type 1050 TD2 |
| 125 | 1050W X 400D X 2361H |
| 126 | CHANNELS (RAILS) |
| 127 | Optz Plus D2 CHNL 2400mm |
| 128 | Optz Plus D2 CHNL 1600mm |
| 129 | Optz Plus D2 CHNL 800mm |
| 130 | OPTIMIZER PLUS-DRIVE TYPE |
| 131 | 2 Bay Drive Type 1050 SD2 |
| 132 | 2 Bay Drive Type 1050 LD2 |
| 133 | 2 Bay Drive Type 1050 TD2 |
| 134 | 1050W X 400D X 2361H |
| 135 | CHANNELS (RAILS) |
| 136 | Optz Plus D2 CHNL 2400mm |
| 137 | Optz Plus D2 CHNL 800mm |
| 138 | OPTIMIZER PLUS-DRIVE TYPE |
| 139 | 2 Bay Drive Type 1050 SD2 |
| 140 | 2 Bay Drive Type 1050 LD2 |
| 141 | 2 Bay Drive Type 1050 TD2 |
| 142 | 1050W X 400D X 2361H |
| 143 | CHANNELS (RAILS) |
| 144 | Optz Plus D2 CHNL 2400mm |
| 145 | Optz Plus D2 CHNL 800mm |
| 146 | OPTIMIZER PLUS-DRIVE TYPE |
| 147 | 2 Bay Drive Type 1050 SD2 |
| 148 | 2 Bay Drive Type 1050 LD2 |
| 149 | 2 Bay Drive Type 1050 TD2 |
| 150 | 1050W X 400D X 2361H |
| 151 | CHANNELS (RAILS) |
| 152 | Optz Plus D2 CHNL 2400mm |
| 153 | Optz Plus D2 CHNL 1600mm |
| 154 | OPTIMIZER PLUS-DRIVE TYPE |
| 155 | 2 Bay Drive Type 1050 SD2 |
| 156 | 2 Bay Drive Type 1050 LD2 |
| 157 | 2 Bay Drive Type 1050 TD2 |
| 158 | (1050W, 400D, 2361H) |
| 159 | CHANNELS (RAILS) |
| 160 | Optz Plus D2 CHNL 2400mm |
| 161 | OPTIMIZER PLUS-DRIVE TYPE |
| 162 | 2 Bay Drive Type 1050 SD2 |
| 163 | 2 Bay Drive Type 1050 LD2 |
| 164 | 2 Bay Drive Type 1050 TD2 |
| 165 | (1050W, 400D, 2361H) |
| 166 | CHANNELS (RAILS) |
| 167 | Optz Plus D2 CHNL 2400mm |
| 168 | Optz Plus D2 CHNL 1600mm |
| 169 | Optz Plus D2 CHNL 800mm |
| 170 | OPTIMIZER PLUS-DRIVE TYPE |
| 171 | 2 Bay Drive Type 900 SD2 |
| 172 | 2 Bay Drive Type 900 LD2 |
| 173 | 2 Bay Drive Type 900 TD2 |
| 174 | 900W X 400D X 2361H |
| 175 | CHANNELS (RAILS) |
| 176 | Optz Plus D2 CHNL 2400mm |
| 177 | Optz Plus D2 CHNL 800mm |
| 178 | OPTIMIZER PLUS-DRIVE TYPE |
| 179 | 2 Bay Drive Type 900 SD2 |
| 180 | 2 Bay Drive Type 900 LD2 |
| 181 | 2 Bay Drive Type 900 TD2 |
| 182 | 900W X 400D X 2361H |
| 183 | CHANNELS (RAILS) |
| 184 | Optz Plus D2 CHNL 2400mm |
| 185 | Optz Plus D2 CHNL 1600mm |
| 186 | Optz Plus D2 CHNL 800mm |
| 187 | OPTIMIZER PLUS-DRIVE TYPE |
| 188 | 2 Bay Drive Type 900 SD2 |
| 189 | 2 Bay Drive Type 900 LD2 |
| 190 | 2 Bay Drive Type 900 TD2 |
| 191 | 900W X 400D X 2361H |
| 192 | CHANNELS (RAILS) |
| 193 | Optz Plus D2 CHNL 2400mm |
| 194 | Optz Plus D2 CHNL 1600mm |
| 195 | OPTIMIZER PLUS-DRIVE TYPE |
| 196 | 2 Bay Drive Type 900 SD2 |
| 197 | 2 Bay Drive Type 900 LD2 |
| 198 | 2 Bay Drive Type 900 TD2 |
| 199 | 900W X 400D X 2361H |
| 200 | CHANNELS (RAILS) |
| 201 | Optz Plus D2 CHNL 2400mm |
| 202 | Optz Plus D2 CHNL 1600mm |
| 203 | Optz Plus D2 CHNL 800mm |
| 204 | OPTIMIZER PLUS-DRIVE TYPE |
| 205 | 2 Bay Drive Type 900 SD2 |
| 206 | 2 Bay Drive Type 900 LD2 |
| 207 | 2 Bay Drive Type 900 TD2 |
| 208 | 900W X 400D X 2361H |
| 209 | CHANNELS (RAILS) |
| 210 | Optz Plus D2 CHNL 2400mm |
| 211 | Optz Plus D2 CHNL 1600mm |
| 212 | Optz Plus D2 CHNL 800mm |
| 213 | OPTIMIZER PLUS-DRIVE TYPE |
| 214 | 2 Bay Drive Type 900 SD2 |
| 215 | 2 Bay Drive Type 900 LD2 |
| 216 | 2 Bay Drive Type 900 TD2 |
| 217 | 900W X 400D X 2361H |
| 218 | CHANNELS (RAILS) |
| 219 | Optz Plus D2 CHNL 2400mm |
| 220 | Optz Plus D2 CHNL 800mm |
| 221 | OPTIMIZER PLUS-DRIVE TYPE |
| 222 | Optz Plus SD2 |
| 223 | Optz Plus TD2 Solid back panel |
| 224 | (1200W, 400D, 2361H) |
| 225 | Optz Plus Hinge door Pair 1200mm 2361mm PS |
| 226 | CHANNELS (RAILS) |
| 227 | Optz Plus D2 CHNL 2400mm |
| 228 | Optz Plus D2 CHNL 800mm |
| 229 | OPTIMIZER PLUS-DRIVE TYPE |
| 230 | Optz Plus SD2 |
| 231 | Optz Plus TD2 Solid back panel |
| 232 | (1200W, 400D, 2361H) |
| 233 | Optz Plus Hinge door Pair 1200mm 2361mm PS |
| 234 | CHANNELS (RAILS) |
| 235 | Optz Plus D2 CHNL 2400mm |
| 236 | Optz Plus D2 CHNL 800mm |
| 237 | OPTIMIZER PLUS-DRIVE TYPE |
| 238 | Optz Plus SD2 |
| 239 | Optz Plus TD2 Solid back panel |
| 240 | (1200W, 400D, 2361H) |
| 241 | Optz Plus Hinge door Pair 1200mm 2361mm PS |
| 242 | CHANNELS (RAILS) |
| 243 | Optz Plus D2 CHNL 2400mm |
| 244 | Optz Plus D2 CHNL 800mm |
| 245 | OPTIMIZER PLUS-DRIVE TYPE |
| 246 | Optz Plus SD2 |
| 247 | Optz Plus TD2 Solid back panel |
| 248 | (1200W, 400D, 2361H) |
| 249 | Optz Plus Hinge door Pair 1200mm 2361mm PS |
| 250 | CHANNELS (RAILS) |
| 251 | Optz Plus D2 CHNL 2400mm |
| 252 | Optz Plus D2 CHNL 800mm |
| 253 | OPTIMIZER PLUS-DRIVE TYPE |
| 254 | Optz Plus SD2 |
| 255 | Optz Plus LD2 |
| 256 | Optz Plus TD2 Solid back panel |
| 257 | (1200W, 400D, 2361H) |
| 258 | CHANNELS (RAILS) |
| 259 | Optz Plus D2 CHNL 2400mm |
| 260 | Optz Plus D2 CHNL 1600mm |
| 261 | Optz Plus D2 CHNL 800mm |
| 262 | OPTIMIZER PLUS-DRIVE TYPE |
| 263 | 2 Bay Drive Type 1050 SD2 |
| 264 | 2 Bay Drive Type 1050 LD2 |
| 265 | 2 Bay Drive Type 1050 TD2 |
| 266 | (1050W, 400D, 2361H) |
| 267 | CHANNELS (RAILS) |
| 268 | Optz Plus D2 CHNL 2400mm |
| 269 | Optz Plus D2 CHNL 1600mm |
| 270 | Optz Plus D2 CHNL 800mm |
| 271 | OPTIMIZER PLUS-DRIVE TYPE |
| 272 | 2 Bay Drive Type 1050 SD2 |
| 273 | 2 Bay Drive Type 1050 LD2 |
| 274 | 2 Bay Drive Type 1050 TD2 |
| 275 | (1050W, 400D, 2361H) |
| 276 | CHANNELS (RAILS) |
| 277 | Optz Plus D2 CHNL 2400mm |
| 278 | Optz Plus D2 CHNL 1600mm |
| 279 | Optz Plus D2 CHNL 800mm |
| 280 | OPTIMIZER PLUS-DRIVE TYPE |
| 281 | 2 Bay Drive Type 1050 SD2 |
| 282 | 2 Bay Drive Type 1050 LD2 |
| 283 | 2 Bay Drive Type 1050 TD2 |
| 284 | (1050W, 400D, 2361H) |
| 285 | CHANNELS (RAILS) |
| 286 | Optz Plus D2 CHNL 2400mm |
| 287 | Optz Plus D2 CHNL 800mm |
| 288 | OPTIMIZER PLUS-DRIVE TYPE |
| 289 | 2 Bay Drive Type 1050 SD2 |
| 290 | 2 Bay Drive Type 1050 LD2 |
| 291 | 2 Bay Drive Type 1050 TD2 |
| 292 | (1050W, 400D, 2361H) |
| 293 | CHANNELS (RAILS) |
| 294 | Optz Plus D2 CHNL 2400mm |
| 295 | Optz Plus D2 CHNL 1600mm |
| 296 | OPTIMIZER PLUS-DRIVE TYPE |
| 297 | 2 Bay Drive Type 1050 SD2 |
| 298 | 2 Bay Drive Type 1050 LD2 |
| 299 | 2 Bay Drive Type 1050 TD2 |
| 300 | (1050W, 400D, 2361H) |
| 301 | CHANNELS (RAILS) |
| 302 | Optz Plus D2 CHNL 2400mm |
| 303 | OPTIMIZER PLUS-DRIVE TYPE |
| 304 | 2 Bay Drive Type 1050 SD2 |
| 305 | 2 Bay Drive Type 1050 LD2 |
| 306 | 2 Bay Drive Type 1050 TD2 |
| 307 | (1050W, 400D, 2361H) |
| 308 | CHANNELS (RAILS) |
| 309 | Optz Plus D2 CHNL 2400mm |
| 310 | Optz Plus D2 CHNL 1600mm |
| 311 | Optz Plus D2 CHNL 800mm |
| 312 | OPTIMIZER PLUS-DRIVE TYPE |
| 313 | 2 Bay Drive Type 900 SD2 |
| 314 | 2 Bay Drive Type 900 LD2 |
| 315 | 2 Bay Drive Type 900 TD2 |
| 316 | 900W X 400D X 2361H |
| 317 | CHANNELS (RAILS) |
| 318 | Optz Plus D2 CHNL 2400mm |
| 319 | Optz Plus D2 CHNL 800mm |
| 320 | OPTIMIZER PLUS-DRIVE TYPE |
| 321 | 2 Bay Drive Type 900 SD2 |
| 322 | 2 Bay Drive Type 900 LD2 |
| 323 | 2 Bay Drive Type 900 TD2 |
| 324 | 900W X 400D X 2361H |
| 325 | CHANNELS (RAILS) |
| 326 | Optz Plus D2 CHNL 2400mm |
| 327 | Optz Plus D2 CHNL 1600mm |
| 328 | Optz Plus D2 CHNL 800mm |
| 329 | OPTIMIZER PLUS-DRIVE TYPE |
| 330 | 2 Bay Drive Type 900 SD2 |
| 331 | 2 Bay Drive Type 900 LD2 |
| 332 | 2 Bay Drive Type 900 TD2 |
| 333 | 900W X 400D X 2361H |
| 334 | CHANNELS (RAILS) |
| 335 | Optz Plus D2 CHNL 2400mm |
| 336 | Optz Plus D2 CHNL 1600mm |
| 337 | OPTIMIZER PLUS-DRIVE TYPE |
| 338 | 2 Bay Drive Type 900 SD2 |
| 339 | 2 Bay Drive Type 900 LD2 |
| 340 | 2 Bay Drive Type 900 TD2 |
| 341 | 900W X 400D X 2361H |
| 342 | CHANNELS (RAILS) |
| 343 | Optz Plus D2 CHNL 2400mm |
| 344 | Optz Plus D2 CHNL 1600mm |
| 345 | Optz Plus D2 CHNL 800mm |
| 346 | OPTIMIZER PLUS-DRIVE TYPE |
| 347 | 2 Bay Drive Type 900 SD2 |
| 348 | 2 Bay Drive Type 900 LD2 |
| 349 | 2 Bay Drive Type 900 TD2 |
| 350 | 900W X 400D X 2361H |
| 351 | CHANNELS (RAILS) |
| 352 | Optz Plus D2 CHNL 2400mm |
| 353 | Optz Plus D2 CHNL 1600mm |
| 354 | Optz Plus D2 CHNL 800mm |
| 355 | OPTIMIZER PLUS-DRIVE TYPE |
| 356 | 2 Bay Drive Type 900 SD2 |
| 357 | 2 Bay Drive Type 900 LD2 |
| 358 | 2 Bay Drive Type 900 TD2 |
| 359 | 900W X 400D X 2361H |
| 360 | CHANNELS (RAILS) |
| 361 | Optz Plus D2 CHNL 2400mm |
| 362 | Optz Plus D2 CHNL 800mm |
| 363 | OPTIMIZER PLUS-DRIVE TYPE |
| 364 | Optz Plus SD2 |
| 365 | Optz Plus TD2 Solid back panel |
| 366 | (1200W, 400D, 2361H) |
| 367 | Optz Plus Hinge door Pair 1200mm 2361mm PS |
| 368 | CHANNELS (RAILS) |
| 369 | Optz Plus D2 CHNL 2400mm |
| 370 | Optz Plus D2 CHNL 800mm |
| 371 | OPTIMIZER PLUS-DRIVE TYPE |
| 372 | Optz Plus SD2 |
| 373 | Optz Plus TD2 Solid back panel |
| 374 | (1200W, 400D, 2361H) |
| 375 | Optz Plus Hinge door Pair 1200mm 2361mm PS |
| 376 | CHANNELS (RAILS) |
| 377 | Optz Plus D2 CHNL 2400mm |
| 378 | Optz Plus D2 CHNL 800mm |
| 379 | OPTIMIZER PLUS-DRIVE TYPE |
| 380 | Optz Plus SD2 |
| 381 | Optz Plus TD2 Solid back panel |
| 382 | (1200W, 400D, 2361H) |
| 383 | Optz Plus Hinge door Pair 1200mm 2361mm PS |
| 384 | CHANNELS (RAILS) |
| 385 | Optz Plus D2 CHNL 2400mm |
| 386 | Optz Plus D2 CHNL 800mm |
| 387 | OPTIMIZER PLUS-DRIVE TYPE |
| 388 | Optz Plus SD2 |
| 389 | Optz Plus TD2 Solid back panel |
| 390 | (1200W, 400D, 2361H) |
| 391 | Optz Plus Hinge door Pair 1200mm 2361mm PS |
| 392 | CHANNELS (RAILS) |
| 393 | Optz Plus D2 CHNL 2400mm |
| 394 | Optz Plus D2 CHNL 800mm |
| 395 | OPTIMIZER PLUS-DRIVE TYPE |
| 396 | Optz Plus SD2 |
| 397 | Optz Plus LD2 |
| 398 | Optz Plus TD2 Solid back panel |
| 399 | (1200W, 400D, 2361H) |
| 400 | CHANNELS (RAILS) |
| 401 | Optz Plus D2 CHNL 2400mm |
| 402 | Optz Plus D2 CHNL 1600mm |
| 403 | Optz Plus D2 CHNL 800mm |
| 404 | OPTIMIZER PLUS-DRIVE TYPE |
| 405 | 2 Bay Drive Type 1050 SD2 |
| 406 | 2 Bay Drive Type 1050 LD2 |
| 407 | 2 Bay Drive Type 1050 TD2 |
| 408 | (1050W, 400D, 2361H) |
| 409 | CHANNELS (RAILS) |
| 410 | Optz Plus D2 CHNL 2400mm |
| 411 | Optz Plus D2 CHNL 1600mm |
| 412 | Optz Plus D2 CHNL 800mm |
| 413 | OPTIMIZER PLUS-DRIVE TYPE |
| 414 | 2 Bay Drive Type 1050 SD2 |
| 415 | 2 Bay Drive Type 1050 LD2 |
| 416 | 2 Bay Drive Type 1050 TD2 |
| 417 | (1050W, 400D, 2361H) |
| 418 | CHANNELS (RAILS) |
| 419 | Optz Plus D2 CHNL 2400mm |
| 420 | Optz Plus D2 CHNL 1600mm |
| 421 | Optz Plus D2 CHNL 800mm |
| 422 | OPTIMIZER PLUS-DRIVE TYPE |
| 423 | 2 Bay Drive Type 1050 SD2 |
| 424 | 2 Bay Drive Type 1050 LD2 |
| 425 | 2 Bay Drive Type 1050 TD2 |
| 426 | (1050W, 400D, 2361H) |
| 427 | CHANNELS (RAILS) |
| 428 | Optz Plus D2 CHNL 2400mm |
| 429 | Optz Plus D2 CHNL 800mm |
| 430 | OPTIMIZER PLUS-DRIVE TYPE |
| 431 | 2 Bay Drive Type 1050 SD2 |
| 432 | 2 Bay Drive Type 1050 LD2 |
| 433 | 2 Bay Drive Type 1050 TD2 |
| 434 | (1050W, 400D, 2361H) |
| 435 | CHANNELS (RAILS) |
| 436 | Optz Plus D2 CHNL 2400mm |
| 437 | Optz Plus D2 CHNL 1600mm |
| 438 | OPTIMIZER PLUS-DRIVE TYPE |
| 439 | 2 Bay Drive Type 1050 SD2 |
| 440 | 2 Bay Drive Type 1050 LD2 |
| 441 | 2 Bay Drive Type 1050 TD2 |
| 442 | (1050W, 400D, 2361H) |
| 443 | CHANNELS (RAILS) |
| 444 | Optz Plus D2 CHNL 2400mm |
| 445 | OPTIMIZER PLUS-DRIVE TYPE |
| 446 | 2 Bay Drive Type 1050 SD2 |
| 447 | 2 Bay Drive Type 1050 LD2 |
| 448 | 2 Bay Drive Type 1050 TD2 |
| 449 | (1050W, 400D, 2361H) |
| 450 | CHANNELS (RAILS) |
| 451 | Optz Plus D2 CHNL 2400mm |
| 452 | Optz Plus D2 CHNL 1600mm |
| 453 | Optz Plus D2 CHNL 800mm |
| 454 | OPTIMIZER PLUS-DRIVE TYPE |
| 455 | 2 Bay Drive Type 900 SD2 |
| 456 | 2 Bay Drive Type 900 LD2 |
| 457 | 2 Bay Drive Type 900 TD2 |
| 458 | 900W X 400D X 2361H |
| 459 | CHANNELS (RAILS) |
| 460 | Optz Plus D2 CHNL 2400mm |
| 461 | Optz Plus D2 CHNL 800mm |
| 462 | OPTIMIZER PLUS-DRIVE TYPE |
| 463 | 2 Bay Drive Type 900 SD2 |
| 464 | 2 Bay Drive Type 900 LD2 |
| 465 | 2 Bay Drive Type 900 TD2 |
| 466 | 900W X 400D X 2361H |
| 467 | CHANNELS (RAILS) |
| 468 | Optz Plus D2 CHNL 2400mm |
| 469 | Optz Plus D2 CHNL 1600mm |
| 470 | Optz Plus D2 CHNL 800mm |
| 471 | OPTIMIZER PLUS-DRIVE TYPE |
| 472 | 2 Bay Drive Type 900 SD2 |
| 473 | 2 Bay Drive Type 900 LD2 |
| 474 | 2 Bay Drive Type 900 TD2 |
| 475 | 900W X 400D X 2361H |
| 476 | CHANNELS (RAILS) |
| 477 | Optz Plus D2 CHNL 2400mm |
| 478 | Optz Plus D2 CHNL 1600mm |
| 479 | OPTIMIZER PLUS-DRIVE TYPE |
| 480 | 2 Bay Drive Type 900 SD2 |
| 481 | 2 Bay Drive Type 900 LD2 |
| 482 | 2 Bay Drive Type 900 TD2 |
| 483 | 900W X 400D X 2361H |
| 484 | CHANNELS (RAILS) |
| 485 | Optz Plus D2 CHNL 2400mm |
| 486 | Optz Plus D2 CHNL 1600mm |
| 487 | Optz Plus D2 CHNL 800mm |
| 488 | OPTIMIZER PLUS-DRIVE TYPE |
| 489 | 2 Bay Drive Type 900 SD2 |
| 490 | 2 Bay Drive Type 900 LD2 |
| 491 | 2 Bay Drive Type 900 TD2 |
| 492 | 900W X 400D X 2361H |
| 493 | CHANNELS (RAILS) |
| 494 | Optz Plus D2 CHNL 2400mm |
| 495 | Optz Plus D2 CHNL 1600mm |
| 496 | Optz Plus D2 CHNL 800mm |
| 497 | OPTIMIZER PLUS-DRIVE TYPE |
| 498 | 2 Bay Drive Type 900 SD2 |
| 499 | 2 Bay Drive Type 900 LD2 |
| 500 | 2 Bay Drive Type 900 TD2 |
| 501 | 900W X 400D X 2361H |
| 502 | CHANNELS (RAILS) |
| 503 | Optz Plus D2 CHNL 2400mm |
| 504 | Optz Plus D2 CHNL 800mm |
| 505 | Electrical Works |
| 506 | Wiring point for light in 1.5 sq. mm.FRLSHPVC insulated multistrandsingle core copper conductor cable (drawn through existing concealed steel conduit) and 5 Amp.flush type switch & ceiling rose/angle/batten holder fixed with 3mm thick phenolic laminated backalite sheet with brass machine screws andcup washers mounted over existing M.S. switch board box/ junction box with supply of all material, labour & T&P etc. required for proper completion of the work as directedat site by the Engineer in charge. 174B/2018 |
| 507 | Same asin item no.174 (B)but for ceiling fan. 177B/2018 |
| 508 | Wiring point for exhaust fan in 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable (drawn through existing concealed conduit) and 15 Amp flush type switch & ceilingrose fixed with 3 mm thick phenolic laminatedbackalite sheet with brass machine screws and cup washers mounted over the existing M.S. box/ Junction box requiredfor proper completion of the work as directed at site by the Engineer in charge. 179B/2018 |
| 509 | Wiringpointforplugwith 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable inheavyguagerigidsteel conduit partly concealed in wall and partly laid in slab alongwith the reinforcementbefore concreting, complete with14 SWG copper earth continuity wire and piano typeswitch and socket etc., complete in all respect including matching colour wash. 141B/2018 |
| 510 | Supply and fixing of switch box 100 x 100 x 50 mm size of approved make made up of 1.0 mm thickISI Marked G.P.sheet All 4 corners folded & spot welded for screw and holes plugged with PVC Nylon Caps . Two or more holes for pipe entryof 25.4 mm on upper and lower sides of the box. Holes shuld be semi-shuttered type and fitted with heavy brass Earth Piller duly screwed & brand name should be embossed. Box flushed in wall including cutting of brick work, fixing it to the level with cement sand mortar, including matching colour wash with s/o all materials, labour and T&P required for proper completion of work as directed at site by the Engineer in charge. 159/2018 |
| 511 | Supply and wiring of3 number 4 sq. mm. FRLSH PVC insulated 1100V grade multistrand single core copper conductor cablein 25 mm dia heavy guage rigid steel conduit concealed in wall with two number14SWG copper earth continuity wire, including matching colour wash etc, complete in all respect. |
| 512 | Supply and wiring of 3 number 6 sq. mm. FRLSH PVC insulated 1100V grade multistrand single core copper conductor cable in 25 mm dia heavy guage rigid steel conduit concealed in wall with twonumber 14SWG copper earth continuity wire, including matching colour wash etc, complete in all respect. |
| 513 | S&F of 0.5 Amp to 5 Amp. SP MCB (10KA) C Curve. CAT A |
| 514 | S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve. CAT A |
| 515 | S&F of50 Ampto63Amp.SPMCB(10KA)1003B/2018 |
| 516 | S&F of 63 Amp.T.P. Isolator. 1006B/2018 |
| 517 | S&F surface/flush mounting 8ways SPN distribution board with additional metal door without MCB complete in all respect, as directedbyEngineer in charge. 1024A/2018 |
| 518 | S & F surface/Flush mounting 6waysV TPN distribution board without additional Door without MCB complete in all respect,as directed at site byEngineer in charge. 1027B/2018 |
| 519 | Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc. The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountendon non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp on incoming etc. |
| 520 | The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A B & B-II and pedestal type for Cat-B and C only. |
| 521 | Incoming |
| 522 | 100 Amp. TPN-1 No |
| 523 | Outgoing |
| 524 | 63 Amp. TNP-2 Nos. |
| 525 | Cat. B. Cubicle Type |
| 526 | Supply Installation Testing & Commissioning of 10kW 24V Power Backup System with 1/2 Hour Battery Backup.The system Rating : 10kWIncoming : 230V AC +/- 10%Out Put : 24V DC +/- 1%Incoming Current Rating : 60A (Max)Outgoing Current Rating : 420A (6 Nos. x 70A)Backup : Battery BackpBackup Time : 30 MinuteIncoming Breaker : 63A DP MCCBOutput Breaker : 6 Nos. 100A DP MCB/MCCBEnclosre : CRCA Sheet Encosure Enclosre Painting : Powder Coated Painting after 7 Tank Sheet Treatement Process |
| 527 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, DC Ceiling/Wall Fans |
| 528 | Supply, installation and testing of DC Exhaust fan |
| 529 | Supply, installation and testing of DC lights |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy