| 1 | 1.10.1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulatedcopper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copperconductor single core cable etc as required.Group A |
| 2 | 1.14.1Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulatedcopper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5sq.mm + 1x1.5 sq.mm earth wire |
| 3 | 1.33Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincludingconnection etc as required. |
| 4 | 1.24.1Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.5/6 amps switch |
| 5 | 1.24.3Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.15/16 amp switch |
| 6 | 1.24.4Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 7 | 1.24.5Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 8 | 1.27.2Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modularswitches in recess etc as required.3 Module (100mmX75mm) |
| 9 | 90.3.20.3Supply & installation of light fittings on TW round block Supply, conveyance installation testing andcommissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with allaccessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit thefitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wireconforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box typefixture |
| 10 | 2.3.1Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door |
| 11 | 2.10.1Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breakersuitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.Single pole |
| 12 | 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB completewith connections, testing and commissioning etc. as required.40 amps |
| 13 | 2.14.2Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual currentcircuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete withconnections, testing and commissioning etc. as required.40 amps |
| 14 | 1.17.12Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 15 | 1.17.30Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm |
| 16 | 1.21.1Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20mm |
| 17 | 5.3Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.(but without charcoal/ coke and salt ) as required. |
| 18 | 90.14.1.2Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dustand vermin proof, cubicle type MV panel board comprising of the following components/ devices &complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panelassembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved designand requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gearcompartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outsfor mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus barchamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required.CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for thefabrication of panel assembly. The measurments will be taken the area of the complete sheets used forpanel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using1.6mm CRCA sheet, powder coated (excluding base frame) |
| 19 | 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and givingconnection as required3.15 mm copper conductor ( 10 SWG) |
| 20 | od1761809/2022_2023Supply and fixing 32A backelite fuse base with HRC fuse link in the existing meter board and givingconnections etc |
| 21 | od1761810/20222023Supply and fixing 32A, 415 V, 2 way neutral link mounted on DMC/ SMC base in the existing meter boardand giving connections etc. |
| 22 | 90.14.5Supply and fabrication conveyance and installation of angle iron frame work for wallmounting panel board |