| 1 | M&L for Comprehensive maintenance, preventive / periodical, routine and corrective (break down),maintenance, servicing, cleaning, inspection and testing ofnurse call system and ensure the proper functions of narrating type call, colour coded room No\"s, call forwrwarding, call escalltion,additional help system, hand set function, includingregular operation and maintenance complete of Make : Process care system, set of tools required for maintenance and operation, replacement of unsercive spares any type bed side unit CCRU,MBCU, emergency pull card unit, door indicators etc the system cosnsists of central display module - 4 Nos, Bed side unit CCRU, MBCU 76 Nos, Bath room emergency pull cord system for single/shared toilets -29 Nos, Door/ corridor indicatorall - 35 Nos as specified and directed. |
| 2 | Meterial and labour for refixing of detached fire alarm detectors any type, remote response indictor with suitable size of nut bolt & washers in fall celing boards and ensure the cable connections etc all as directed |
| 3 | Supply and fix SMPS based automatic floot cum bost battery charging unit suitable for 12 volts lead acid battery 180 AH for existing fire fighting control panelwith following parameters Voltage 12 voltfrequency 50 HZ ,DC, current 10 to 20 amps, input up to 270 Volts, output 12 Volt, Short circuit, over volatge, reverse polarity protection, fan cooling type, auto cut system during the time of engine working condition including taking down unserviceable chrger unit all as directed |
| 4 | Supply and fix lead acid battery 12 volt 150 AH heavey duty model XP 1500for suitable for 60 hp pump set Make - Exide, Tata, Amaron |
| 5 | Labour for repair/service ,checking and callibaration of auto/manual operation fire fighting control panel with servicing of main/jockey pump starter, auto/manual operation and main Diesel pump operation with respect water pressure switch of pipe line, auto cut operation of jockey pump etc all as directed |
| 6 | Labour for fire alarm panel servicing, configaration, testing for proper function, alarm location indication, interconnection of repeter panel etc forof 4 loop with three cards fire alarm panel minimum 190 detectors per card all as directed |
| 7 | Labour for checking and servicing, cleaning of smoke detector any type, remote response indicators for its proper function zone wise and checking of connections all as directed minimum ninetry six items per zone all as directed |
| 8 | Supply and fix CP hose 15 meter legnth for fire fighting system including taking down unserviceable hose pipeall as directed |
| 9 | Supply and fix sprikler head glass bulb type standered response as per IS 15106 pendent type temperature range 68 degree including unserviceable sprinkler all as directed |
| 10 | Supply and fix detector complying with certified EN 45 addressable type smoke detector photoelectric/optical with base with self built inteligence as per IS 11360 including taking down unserviceable detectors any type all as directed |
| 11 | Supply and fix remote response indicators including taking down unserviceable detectors all as directed |