| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth within all lead and lift, as directed by Engineer-in-Charge. All kinds of soil as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift |
| 2 | Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within lead and lift. All kinds of soil as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived fromnatural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 7 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) :With F.P.S.(non-modular) bricks as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 8 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 9 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 10 | Providing and fixing pre-coated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-Charge. The sheet shall be fixed using self-drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 11 | 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 12 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 13 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 14 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 15 | Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 16 | Design, Supply, Fabrication and Installation of Multiwall Polycarbonate Sheet 5mm thick of required shade, UV stabilised and sheet should be properly jointed with M.S frame in desired shape and Size, including fixing with all necessary fasteners, hooks, bolts, nuts, sealants and aluminium strips of required size as per approved specifications. (M.S frame work shall be paid separately.) 5 mm thick multiwall Polycarbonate sheet as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 17 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 18 | Supplying and drawing 3x6 sq mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit/Casing/Wall Trunk asper entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 19 | Supplying and fixing of 25 mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required asper entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 20 | Supplying and fixing Triple pole 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of Single pole, in the existing MCB DB complete with connections, testing and commissioning etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 21 | Supplying and fixing 32 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 32 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 22 | Supplying and fixing of Premium 20 W Led batten with \"eye soft\" technology & glarefree diffuser for perfect application in modern homes. as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 23 | Supplying and fixing of 25 mm size of medium class PVC Flexible Pipe along with accessories in surface as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 24 | Supply of Metal Body Exhaust Fan Sweep 300 mm ,Air Delivery 1050 m3/hr, Speed 1325 rpm, Power Input 63 W, suitable for operation on 230 V 50 Hz supply, etc asper entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |
| 25 | Laying of 3x4 sq mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit/Casing/Wall Trunk asper entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. |