Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #46331065

Tender For Renovation Of Terrace Of Guest House In Iop Campus, Bhubaneswar

Issued by Boards / Undertakings / PSU · bhubaneswar, Odisha
Tender Value
9.49 Lakhs
Estimated cost
Bid Submission
04 Dec 2024
0 days left
EMD
19000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
bhubaneswar → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Renovation Of Terrace Of Guest House In Iop Campus, Bhubaneswar

BOQ

Name of Work: Renovation of terrace of Guest House in IoP Campus
Sl. No. Item Description
1Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface andreinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-charge. 50 mmaverage thickness
2Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.(Approved Brand : Dr. fixit, FOSROC)
3Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer. (Approved Brand:Dr. Fixit, FOSROC)
4Providing and laying a rendering screed of avg 50 mm thick in 1:2:4 ratio (cement:sand:6 mm down aggregate) admixed with Dr. fixit Pidicrete MPB or equivalent @ 5% by weight of cement or as per requisite % as recommended by the manufacturer & sandwitched with 24 gauze chicken wire mesh all in complete including khurras with neat good finish all in complete. And allow the surface for water curing for minimum 15 days. (Approved Brand : Dr. Fixit, FOSROC)
5Providing and laying 120 gsm geotextile membranes with an overlap of 100 mm on the cured membrane surface with suitable adhesive all in complete
6Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.(Approved Brand FOSROC, DR. FIXIT)
7Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars forsunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge.Upto and including 12mm dia.
8Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge.Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).25 mm average thickness in 2 layers.(Make: Dr. Fixit, FOSROC)
9Providing and fixing 100 mm diameter and 60 cm long rain water spout in cement mortar 1:4 (1 cement : 4 fine sand).
10Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
11Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete.110 mm
12Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
13Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase
14Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
15Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Coupler.110 mm
16Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Shoe (Plain)110 mm Shoe
17Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete :Serrated with central bulb (225 mm wide, 8-11 mm thick)

AI Tender Summary

OUR REF NO 46331065
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 9.49 Lakhs
LAST DATE 04-12-2024
Authority
Authority Name Institute Of Physics
Work Description Renovation Of Terrace Of Guest House In Iop Campus, Bhubaneswar
Basic Detail
Tender No NIT/IOP/101/2024-25
Bidding Type Tender
Location
City bhubaneswar
State Odisha
Key Dates
Publish Date 22 Nov 2024
Submission Date 04 Dec 2024
Open Date 05 Dec 2024
Finance
Tender Value 9.49 Lakhs
Tender Fee Ref. Documents
EMD 19000
Exemption Available
Document List
4d870fc5-64f4-4690-9ef8-885c974168ee.html
BOQ_877799.xls
GCC.pdf
Technicalspecification.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 22, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 04, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 05, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

4d870fc5-64f4-4690-9ef8-885c974168ee.html

xls

BOQ_877799.xls

pdf

GCC.pdf

pdf

Technicalspecification.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders