| 1 | Providing and fixing factory made uPVC glazed/ wire mesh windows/doorscomprisingofleadfreeuPVCmulti- chamberedframe,sashandmullion/coupler(wherever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (whereever required) of appropriate dimension, EPDM gasket, hardware,SS 304 grade fasteners of minimum 8 mm dia. with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as perIS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steelscrewsetc.Profileofframe,sash&mullion(if required) shall be mitred cut and fusion welded/ mechanicallyjointeddulysealedat allcorners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification &direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh/ Glazing of plain/ toughened/ laminated/ double glass unit with/ without high performance coatings as per designrequirementsandconformingtoIS: 3548&IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute,to be provided by the manufacturer for : (iii)Siteswith basic wind speed > 45 m/sec as per IS 875 - Part 3 (iv) Sites with structure height more than 20m for all wind speeds. |
| 2 | Fixed window/ ventilator with mullion/ transom.i) Using R4 series with frame (64mm & above) x (50mm & above)&mullion(64mm&above)x(70mm&above). (Height above 2.5 meter) |
| 3 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 4 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 5 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 6 | Providing and fixing plain multipurpose cement board(Hight pressure steamcured)withsuitablescrewsforcementparticleboardin ceiling etc. complete (frame work to be paid seperatately). |
| 7 | 6 mm thick Cement fiber board, Type-B, Category-III as per IS: 14862:2000 |
| 8 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : |
| 9 | Two or more coats on new work |
| 10 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 11 | With cement mortar 1:4 (1 cement : 4 fine sand) |
| 12 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : |
| 13 | Of sectional area below 40 square centimetres |
| 14 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 15 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 16 | Asbestos Cement sheet |
| 17 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 18 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall |
| 19 | 25 mm nominal dia Pipes |
| 20 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 21 | 30 cm lengthi) 15 mm nominal bore |
| 22 | 45 cm lengthi) 15 mm nominal bore |
| 23 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 24 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 25 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 26 | Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in- charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). |
| 27 | Providing and fixing C.P. brass Health Faucet of approved quality & colour. |
| 28 | 15mm nominal bore (jaguar or equivalent.) |
| 29 | Providing and fixing C.P. brass Two in One bib cock of approved quality conforming to IS:8931. |
| 30 | 15 mm nominal bore. (Jaguar or equivalent) |
| 31 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 32 | 15 mm nominal bore (Jaguar or equivalent). |
| 33 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 34 | 15mm nominal bore (Jaguar or equivalent). |
| 35 | Providing and fixing pre-painted galvalume (PPGL) steel profile sheets AZ-150 of brand Tata Bluescope steel, Everest Industries Ltd., JSW Steel Ltd., Jindal India Ltd. or equalavent(size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with aluminium zinc coating 150 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling / self tapping aluminium screws (Xylan) of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 36 | Providing and fixing pre-painted galvalume (PPGL) steel profile sheets accessories 0.50 mm (+0.05 %) total coated thickness, with aluminium Zinc coating 150 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : of brand Tata Bluescope steel, Everest Industries Ltd., JSW Steel Ltd., Jindal India Ltd. |
| 37 | Ridges plain (500 - 600mm) |
| 38 | Plain Valley 900mm |
| 39 | Providing and fixing eaves or facia baord with 19mm thick WPC board 30 cm wide including fixing with GInut and bolts etc. complete. |
| 40 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor singlecorecableinsurface /recessedmediumclassPVC conduit, with modular switch, modular plate, suitable GI box and earthingthepointwith 1.5sq.mm FRLSPVC insulated copper conductor single core cable etc. as required. |
| 41 | Group C |
| 42 | Wiringforlight/powerplugwith 2X4sq.mmFRLSPVC insulatedcopperconductorsinglecorecableinsurface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 43 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 44 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 45 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 46 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 47 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 48 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 49 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 50 | Supplying and fixing 3pin, 5A ceiling rose on the existing junctionbox/woodenblockincludingconnectionsetc.as required. |
| 51 | Installation ,Testing,Commissioningofwallbracket/ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lampsperfitting,completewithallaccessoriesincluding connections etc. as required. |
| 52 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 53 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 54 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 55 | Upto 450 mm sweep |
| 56 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 57 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 58 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 59 | SupplyingandfixingPVC batten/angle holderincluding connections etc. as required. |
| 60 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 61 | 4 way (4 + 12), Double door |
| 62 | 8 way (4 + 24), Double door |
| 63 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of followingpolesintheexistingMCBDBcompletewith connections, testing and commissioning etc. as required. |
| 64 | Single pole |
| 65 | Supplyingandfixingfollowingrating,doublepole, 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 66 | 63 A |
| 67 | EarthingwithG.I.earthpipe 4.5metrelong,40mmdia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 68 | Providing and laying earth connection fromearth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 69 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 70 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 71 | Upto 35 sq. mm |
| 72 | LayingandfixingofonenumberPVCinsulatedandPVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 73 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 74 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 75 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, boltsandwasher, paintingtheflatiron withprimerand paint etc. as required. |
| 76 | SupplyingandfixingoflightclassG.I.pipeof50mmdia. (nominal)3 metreslength alongthepolefor protectionof under ground cable as required. |
| 77 | Providing, laying and fixing following diaG.I.pipe(medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required |
| 78 | 50 mm dia |
| 79 | Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 80 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 81 | Supplying of LED Adore 10 W 2 star rating B22 CDL lamp similar to Make: Havells Cat No. LHLDEUEEML8R010 6500K or its equalent to ISI standard. |
| 82 | Supplying of Batten for LED tubes equivalent to HAVELLS REGALBATTENT8UPTO1X22WSSBSWH including 20W LED Tube lamp equivalent to HAVELLS CRYSTAL GLASS LED TUBE LIGHT (Double side connection) Cat No. CRYSTALT81213DSTL20WLED865SGLASS complete or its equivalent to ISI standard. |
| 83 | Supplying of 8 W Mirror light self ballasted LED Batten, extruded thermoplastic body with PC diffuser in unique square shape, >180º wide distribution equivalent to Polycab INTENSO LXS LED BATTEN - PC PROFILE Cat No. INTENSO LXS LED BATTEN 1 FEET 8W 6500K complete or its equivalent to ISI standard etc. as required. |
| 84 | Supplying of exhaust fan 300mm sweep Heavy Duty (900 RPM) equivalent to Orient Electric 300mm Heavy Duty Exh. (900 RPM)-Grey complete or its equivalent to ISI standard. |
| 85 | Supplying of Energy efficiency BLDC ceiling fan of white in colour with remote control of 1200mm sweep, suitable for operation on 230 volts, single phase, 50Hz, AC supply including 30cm long down rod etc. as required equivalent to Havells Efficiencia Neo (BLDC 26 W) or its equivalent to ISI specifications. |
| 86 | Supplying and fixing of 45 W new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with highly efficient LEDs as Lighting Source and lens embedded PC Cover having Bottom Opening separate driver compartment with IP66 protection and impact resistance of IK08 equivalent to make Havells ENDURA SUNDOWN Cat No. ENDURASUNDOWNSL45WLED765PASYBOPC or its equivalent to ISI standard. |
| 87 | Supply, installation, testing and commissioning of following capacity and rating wall mounted split Air conditioner, inverter type fitted with rotary compressor operating on 230v ± 10%, 50Hz single phase AC supply with evaporator and condensing unit made of copper tubes , cordless remote control, copper piping for both suction and discharge of five (05) meters length with protection covering for piping of suitable size of medium PVC pipe, power and control cabling as per site requirement, outdoor stand duly painted, comprising of following etc. complete as per requirement including first charge of refrigerent. a) Insulated copper pipe lines liquid and suction lines as per manufacturer rocommendation.b) Flexible copper cable between indoor & outdoor unit of suitable size as per manufacturer rocommendation.c) Drain pipe.d) Suitable size of PVC pipe for protection covering of refrigent line if required as per direction of E-in-C. |
| 88 | 1.5 TR capacity, 5 star rating |
| 89 | Supplying of following sizes XLPE insulated heavy duty armoured aluminium conductor UG cable of 1.1 KV grade conforming to IS: 7098 (Part I) and IS No: 1554 (Part-I) 1988 as applicable.(make : CCI/ Gloster/ Havells / Polycab/ Finolex. etc as required. |
| 90 | 4 core x 35 sq.mm |
| 91 | Providing and eraction of single phase metering box made out of SMC of size 400 x 300 x 190mm with hinged cover and locking arrangements, viewing glass etc. as required similar to Sintex Model No. GSMB 4030. |