| 1 | Dismantling GS sheet roofing including ridges, hips, vaIIeys, gutters wind ties etc. including dismembering and stacking of serviceable materials and unserviceable materials separately with all lifts and upto a lead of 50 m etc. complete as per direction of the Engineer- in-charge. |
| 2 | Dismantling old plaster or pointing, raking out joints, cleaning and preparing the surface for re-plastering or re-pointing including disposal of rubbish to the dumping ground mping ground with all leads and lifts etc. complete as per direction of the Engineer- in- charge. |
| 3 | Dismantling doors, windows and clerestory windows (steal or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : a) Of area 3 sqm. and below. |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (All kinds of soil ) |
| 5 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compact or or by any suitable method complete. |
| 6 | Providing and laying in position cement concrete of Specified grade excluding the cost of centring and shuttering -All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size) |
| 7 | First class bricl‹ work in foundation and plinth including cost of all materials as required complete\"- (1) In cement mortar I .4 ( 1 cement : 4 fine sand ). |
| 8 | First class brick work in superstructure in triangular, square and rectangular pillars above plinth level including cost of all materials as required complete:- (iii) In cement mortar 1 :4(1 cement : 4 fine sand ) |
| 9 | Half brick masonry work with first class bricks in superstructure up to floor five level including cost of all materials as required complete:- (iii) In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 10 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Upto plinth level. i)Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 11 | Centering shuttering including strutting, propping etc. and removal of form work for : Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 12 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement. i) 1:2:4 ( I Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size). |
| 13 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position : i) Local Teak Wood |
| 14 | Providing wood work in frames of false ceiling, part*ions etc. sawn and put up in position : i) Local Teak Wood |
| 15 | Providing 40 • 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm 1:3:6 mix (1 cement : 3 fine sand : 6 graded stone aggregate 20mm nominal size) |
| 16 | Providing and fixing glazing of approved quality in aluminium doors, windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item)A) With float glass panes of 5.5 mm thickness ( weight not less than 13.75 kg / sqm ) |
| 17 | Providing and fixing panelled / or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked bright finished / black enamelled M.S butt hinges with necessary screws excluding panelling and or glazing, which will be paid for separately but including the wooden beading of 20 • 12 mm for fixing panelling and or glazing as per direction of Engineer-In-Charge. i) Local Teak wood. a) 35 mm thick shutters |
| 18 | Providing and fixing bright finished 10omm mortise lock with 6 levers without pair of handles for aluminium door with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge. |
| 19 | Providing and fixing IS : 3564 marked aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete. |
| 20 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Pan I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) 35 mm thick including ISI marked Stainless Steel bull hinges with |
| 21 | Providing and fixing bright finished brass handles with screws etc. complete. A) 125mm |
| 22 | Varnishing with varnish of approved brand and manufacturer [Payment shall be made alter submission of Test Certificate issued by the Manufacturer]. 1) Two or more coats of glue with copal varnish over an under coat of flitting varnish. |
| 23 | Providing and fixing P V C false ceiling providing SPUF 142-D-01(Different design 10 mm thick 150 mm width and necessary length ) approved colour concelled type penneled carrier T section (EWUF 106:40X63.5 mm and L section (EWUF 405:40X68 mm) with necessary screws, hold fast, wooden beading and M.S pipe structured 48 mm dia @1200 mm c/c including cutting holes and making good walls etc. complete as per direction of Engineer-in- Charge. |
| 24 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shattering -All work upto plinth level:1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size) |
| 25 | 12 mm cement plaster of mix (1/ In cement mortar 1 : 4 ( 1 œment : 4 fine sand ) |
| 26 | 12 mm cement plaster of mix in/c net cement punnig a) In cement morter 1 : 4 ( 1 cement : 4 fine sand ) |
| 27 | Steel work in built ug tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.1) Hot finished welded type tubes |
| 28 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required etc. complete as per direction of Engineer-in-charge. i) 0.63mm thick with zinc coating not less than 275gm/m2 |
| 29 | Providing ridge or hips of width 45 cm {Tata shakti /Jindal) fixed with Zink coated high quality Hex flanged self drilling screw (size 12 x 55 mm) by drill machine in/c. washer complete as per direction of Engineer -in -charge.) 0.35 mm thick with Zink coating not less than 275 gm /sqm. |
| 30 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : a)Local Teak Wood .i) 50 X 12 mm |
| 31 | Providing and fitting ,fixing Medium Density Fiber hard board sheet ceiling with wooden beading ,nails etc. complete as per direction of Engineer -in-Charge.(wooden beading will be paid separately) a) 6 mm thick sheet. |
| 32 | Providing and fixing factory made UPVC door frame made of UPVC extruded, section having an overall dimension, as below (Tolerance +/- 1mm) with wall thickness 2.0mm+/- 02mm. corners of the door frame to be jointed with alvanized brackets and stainless screws, joint mitred and plastic wilded. The hinge side vertical of the frames reinforced by alvanized MS tube of size 19 x 19 mm and 1 mm +/- 0.1 mm wall thickness and 3 nos stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-Charge. 1) Extruded section Profile size 48x40 mm. |
| 33 | Providing and fixing to existing door frames. a) 24 mm thick factory made PVC door shutters made of styles and rails of a UPVC hollow section of size 59x24 mm and wall thickness 2 mm + 0.2 mm with inbuilt edging on both sides. The styles and rails mitred and joined at the corners by means of M.S. galvanized /plastic brackets of size 75X220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanized MS tube of size 20x2O mm and 1 mm z + 0.1 mm wall thickness. The lock rail made up of \"H\" Section, a UPVC hollow section of size 100X24 mm and 2 mm + 0.2 mm wall thickness fixed to the shutter styles by means of plastic /galvanized MS \"U\" cleats. The shutter frame filled with a UPVC multi-chambered single panel of size not less than 620 mm, having overall thickness of 20 mm and 1 mm + 0.1 mm wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanized MS rod and fastened with nuts and washers, complete as per manufacturer\"s specification and direction of Engineer-In-Charge. (for W.C. and Bathroom door shutter). |
| 34 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 - 2017, of approved make. in all colors and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge. a) Double charged Stainfree vitrified tiles (Glossy). 1) Size of tile 600 mm x 600 mm |
| 35 | Providing and laying 1st class quality vitrified floor tiles in different size (thickness to be specified by the manufacturer) with water absorption less than 0.089s and conforming to IS: 15622 - 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm. including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge. a) Glazed vitrified Tiles (Glossy / Mat Finish/ Anti-Said). i) Size of tile 600 mm x 600 mm |
| 36 | Providing and fixing Precast chequeredcement concrete tiles 18 mm thick, laid in footpath & courtyard, on 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with neat cement slurry Including rubbing and cleaning etc. all complete as per direction of Engineer-in-charge. |
| 37 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 38 | Wall painting with acrylic plastic emulsion paintof approved brand and manufacture to give an even shade (Payment shall be made after submission of Test Certificate issued by the manufacturer} : a) Two or more coats on new work |
| 39 | Paintingwith synthetic enamel paint ( one or more coats ) of required colour of approvedbrand and manufacture on old work to give an even shade including preparation of surface required complete as per direction of the Engineer in charge |
| 40 | Finishing walls with acrylic smooth exterior paint of required shade of approved brand end manufacture [Payment shell be made after submission of TestCertificate issuedby the Manufacturer] : A) New work ( Mo or more coats applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 41 | Finishing walls with acrylic smooth exterior paint of required shade of approved brand and manufacture on old work ( one or more coats ) including preparation of surface as required complete as per direction of the Engineer in charge. |
| 42 | Painting on G.S. sheet with synthetic enamel paint ( one of more coats ) of approved brand and manufacture of required colour to give an even shade on old work including preparation of sultans as required complete as per direction of the Engineer in charge. |
| 43 | Painting with synthetic enamel paint of approved brand end manufacture of required colour to give en even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer l: a) Two or mom costs on new work over an under coat of suitable shade with ordinary paint (primer) of approved brand and manufacture. |