| 1 | Dismantling GS sheet roofing including ridges, hips, valleys, gutters wind ties etc. including dismembering and stacking of serviceable materials and unserviceable materials separately with all lifts and upto a lead of 50 m etc. complete as per direction of the Engineer- in-charge. |
| 2 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc, complete and stacking within 50 metres lead : a) Of area 3 sqm and below. |
| 3 | Dismantling old plaster or pointing, raking out joints, cleaning and preparing the surface for re-plastering or re-pointing including disposal of rubbish to the dumping ground with all leads and lifts etc. complete as per direction of the Engineer- in- charge. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering -All work upto plinth level:1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size) |
| 5 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.1. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever requirrequired etc. complete as per direction of Engineer-in-charge. a) 0.63mm thick with zinc coating not less than 275gm/m2 |
| 6 | Providing ridges or hips of width 60 cm overall width plain G.S. sheet fired with polymer coated J or L hooks, boIts and nuts 8 mm dia G.I. limpet and bitumen washers etc. complete as per direction of Engineer-in-charge. A) 0.63mm thick with zinc coating not less than 275gm/m2 |
| 7 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. i) Hot finished welded type tubes |
| 8 | Providing wood work in flames of False ceiling, partitions etc. sawn and put up in position |
| 9 | Providing and fixing wooden moulded bending to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : a)Local Teak Wood . i) 50 x 12 mm |
| 10 | Providing and fitting, fixing Medium Density Fiber h8rd board sheet ceiling with wooden beading , nails etc. complete as per direction of Engineer-in-Charge. (Wooden beading will be paid separately) a) 6 mm thick sheet. |
| 11 | 12 mm cement plaster of mix (1) In cement mortar 1 : 4 (1 cement : 4 fine sand ) |
| 12 | 12 mm cement plaster of mix in/c net cement punniga) In cement mortar 1 : 4 ( 1 cement : 4 fine sand ) |
| 13 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. complete as required\"- i) In grating, frames, guard bar, railing, brackets, gates and similar works, all complete. |
| 14 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: A) two or more coats on new work over an under coat of suitable shade with ordinary peint (primer) of approved brand and manufacture |
| 15 | Painting with synthetic enamel paint ( one or more coats ) of required colour of approved brand and manufacture on old work to give an even shade including preparation of surface as required complete as per direction of the Engineer in charge. |
| 16 | Finishing walls with acrylic smooth exterior paint of required shade of approved brand and manufacture on old work ( one or more coats ) including preparation of surface as required complete as per direction of the Engineer in charge. |
| 17 | Finishing walls with acrylic smooth exterior paint of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : A) New work ( two or more coats applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 18 | Distempering with 1st quality washable acrylic distemper of approved brand and manufacture and of required shade on old work ( one or more coats ), to give an even shade as required complete as per direction of the Engineer- in- charge. |
| 19 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre. of approved brand and manufacture to give an even shade |Payment shall be made after submission of Test Certificate issued by the Manufacturer] \" a) New work ( two or more coats) over and including water thinnable priming coat with cement primer. |