Tender For Special Repair To Certain Buildings At Af Stn Bamrauli (Phase-I)., bamrauli-Uttar Pradesh

Military Engineer Services has published Tender For Special Repair To Certain Buildings At Af Stn Bamrauli (Phase-I).. Submission Date for this Tender is 23-12-2024. Building Work Tenders in bamrauli Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

46195750
Corrigendum : Tender For Special Repair To Certain Buildings At Af Stn Bamrauli (Phase-I).
Tender
Indian
Uttar Pradesh
Bamrauli
23-12-2024

Tender Details

Tender For Special Repair To Certain Buildings At Af Stn Bamrauli (Phase-I).; 1 Demolition of cement Concrete unreinforced of any description and in any position not otherwise specifically provided for etc complete all as specified and as directed. 2 M&L forcement concrete 1:2:4 type B-0 using12.5mm graded aggregate as in any position etccomplete all as specified and as directed. 3 Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) , removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. 4 M&L for 7 to 8 mm thick coloured Non Skidceramic tiles(square/ rectagular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm in floors etc. setand jointed in neat cement slurry and pointed in white or coloured cement to match over andincluding 15mmthick screed bed or beddinglayer in cement mortar 1:6, surface finished even and roughcomplete all as specified and as directed. 5 M&L for10 mm thick double chargedVitrified Ceramic colouredtiles (square/ rectagular)of size of tiles exceeding 0.36 Sqm but not exceeding 0.64 Sqm in each tilesin floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchover andincluding 15mmthick screed bed or beddinglayer in cement mortar 1:6, surface finished even and roughcomplete all as specified and as directed. 6 M&L for 6 to 7 mm thick Glazed ceramic coloured tiles in vertical surface of size450mmx 350 mm, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and inclduing 10mm thick rendering in cement mortar 1:4complete all as specified and as directed. 7 M&L for filling white cement on floor/wall tiles joints including removing old fillings etc complete all as specified and as directed. 8 Taking downold PVC soil, waste and rain water pipes (any size or pattern) including all fittings, heads, shoes, bends, swan-necks,bends etc complete all as specified and as directed. 9 S&F 110 mm bore PVC (SWR) rain water pipes, single socketed, in any length withadhesive joints , fixed to walls with and including mild steel clamp of suitable sizecomplete all as specified and as directed. 10 S&F 75 mm bore PVC (SWR) rain water pipes, single socketed, in any length withadhesive joints , fixed to walls with and including mild steel clamp of suitable sizecomplete all as specified and as directed. 11 S&F110mm PVC (SWR) bendsany radiuscomplete all as specified and as directed. 12 S&F 75mm PVC (SWR) bends any radiuscomplete all as specified and as directed. 13 S&F 110mm PVC (SWR) junction single T equal or unequal with access door complete all as specified and as directed. 14 S&F 110mm PVC (SWR) vent cowl complete all as specified and as directed. 15 S&F 75mm PVC (SWR) vent cowl complete all as specified and as directed. 16 M&L forfalse ceiling at all heights with fully perforated 12 mm thick micro tegular edged or 10 mm thick square edged GRG (Glass FibreReinforced Gypsum) false ceiling tiles ofSize 595mm x 595 mm of approved texture, 12 design and patterns having moisturecontent less than 2%, humidity resistance ed- of 99%, NRCO 0.50 to 0.75 as per IS:8225:1987, Non combustible as per BS 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter- locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main- T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15mmx 32mm of length 1200 mm and secondary intermediate cross-T of size 15mm X 32 mmn of length 600 mm to form grid module of size 600mmx 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) tee 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L -shape level adjuster of size 85mmx25mmx2mm galvanised iron perimeter wall angle of size 24mmx 24mmx 0.40mm of length 3000 mm to be fixed on periphery wall partition with the help of plastic rawl plugs at 450 mn center to Center and 4Omm long dry wall wood screws, The work shall be carriod out as per specifications, drawing and asper directions of the Engineer-in- Charge including removal of existing unserviceablefalseceiling complete all as specified and as directed. 17 M&L forpowder coated (thickness of powder coating not less than 50 micron) with aluminium doorframes ofsize 101.50 mm x44.50mmx1.42mm,style & rail of shutter of size 101.6mm X44.45mm X1.42mm (Section shall be as per Drg No CE/ALD/TD -224 sh 1/1). with 3 Nos hinges powder coated including one hydraulic door closer , with glazingclips rubber packing for air lock purpose alumiumanodized snapbeadingof weight not less than0.71kg/RM screw for fixed glass panes with frame & shutter covered with selected quality of tinted glass 5.50 mm thick including necessary buildershardware fittings suchas aluminum powder tower bolts 200mmlong02 Nos for each shutter, 150mm long handle 2 Nos and 100mm size brass mortice lock four lever suitable forshutter 1No ofmake Godrejcomplete all as specified and as directed. 18 S&F in repair for powder coated (thickness of powder coating not less than 50 micron) aluminium window three track sliding type weighing not less than 1.35 Kg/RM including 5mm thick glass fixed with rubber gasket. The size ofaluminium member of shutter is 65mmx40mm alongwith required necessay fittings etc complete all as specified and directed.Note :-Aluminium section shall be as per drg. No. CE/ALD/TD-194 sheet No. 1/2 & 2/2 19 M & L for taking down cement plaster on brick work or concrete surfaces including racking out joints, hacking for key scrubbing down with water etc andapplying 10 mm thickrendering in ready mix cement plaster 1: 4 onbrick work or concrete surfaces of wallsmixed with water proofing compound@ 3% by weight of cement or as per manufacturer instructions, finished even and fair over and includingapplying one coat of smart care damp guard/block 2K ofAsian paints / Dr. Fixit or equivalent as approvedcomplete all as specified and as directed. 20 Dismantling ofboarding as in wall panelingofany description, fixed in any position with nailscomplete all as specified and as directed. 21 S&F Solid PVC Wall lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site over and including PVC frame as per specifications and drawing duly fitted into the wallas per manufacturers instruction complete all as specified and as directed. 22 Taking down cement plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etccomplete all as specified and as directed. 23 M&L 15mm thick renderingin cement mortar 1:6 onbrick work or concrete surfaces, surface finishedeven and faircomplete all as specified and as directed. 24 M&L for preparation of newly plastered surfaces of wall projected face of chajja, projected face of roof slabs and face and sides of sunshade including preparation of surfaces including cornices, plasters etc and applying two coat of exterior emulsion paint of approved shade andin pattern (two or more colour combination)as approved over one coat of alkali resistant primer over and including1mm thick wall care putty complete all as specified and as directed . 25 M&L for complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means and finishing old/new surface of walls with two coats acrylic smooth exterior paint of approved shade@ 1.67 litre /10 Sqm over and including 1 mmthick wall care putty and applyingpriming coat of exterior primer@ 2.20 Kg/10 sqm)complete all as specified and as directed. 26 M&L for applyingtwo coats of 1st quality acrylic distemper having VOC content less than 50 gms/litre of approved manufacturer of approved shadecomplete as per manufacturers instructionover 1mm thick plaster of paris putty complete all as specified and as directed. 27 M&L for applying one coat of synthetic enamel paint of approved shade including preperation of old painted wood and woodl based materials of any description not otherwise describedover 10 cm width or girth complete all as specified and directed. 28 S&F Double action floor spring hydraulically regulated made up of minium 1.25 mm thick aluminium alloysheet foundation box, main body with stainless steel cover, covering pivot made of brass, other made of mild steel heavy duty and fixedcomplete all as specified and as directed. 29 Dismantling of plain or corrugated steel sheeting , any gauge, thicknessincluding nainital or similar pattern roof covering complete all as specifed and directed 30 S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screwscomplete all as specified and as directed. 31 S&F rolled mild steeltrusses(framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe 410 -W (Gde E- 250) quality A complete all as specified and as directed. 32 Excavating over areas not exceeding 1.5 m deep and getting out in hard/dense soilcomplete all as specified and as directed. 33 M&L for cement concrete 1:2:4 type B-2using 40mm graded stone aggregate as in foundations,filling and mass concrete etccomplete all as specified and as directed. 34 Removing excavated materialto a distance exceeding 1.50 km but not exceeding 5 km and depositingwhere directed outside the defence area complete all as specified and as directed. 35 M&L applying two coat of synthetic enamel paint over a coat of red oxide primer including preperation of newly surfaces ofsteel and ironof any description over 10cm in width or girthcomplete all as specified and as directed. 36 S&F in repair One piece Vitreous china wash down water closet (Pedestal Pattern)of size 645mmx35mmx730mm white with soft close seat cover and twin flush fittings, toilet paper holder, health faucet, PVC connection, angular stop cock 2 Nos with flange etc complete all as specified and as directed.Note :- Vitreous china wash down water closet (Pedestal Pattern) Cat Part No. CURATOR S1013132 S trap 250mm of Cera or equivalent make as approved. 37 S&F in repair vitreous china wall hung wash hand basin with pedestal snow white miniumum size630mmx450mm including chromium plated brass coupling,chromium plated brass centre hole basin mixer, 450 mm PVC braided connection (02 Nos), angular stop cock 02 Nos complete all as specified and as directed.Note :- Vitreous china wall hung wash hand basin Cat Part No. CONCORD S2040112, Pedestal cat part No S2090107 & chromium plated brass centre hole basin mixer Cat part No F2002461 of Cera or equivalent as approved. 38 S&F in repair 10 litres capacity PVC valvless,syphonic action type,flushing cistern,low level,white, with inlet ball valve,float and hadle including brackets and 32 mm bore PVC flush pipe,complete all as specified and as directed. 39 S&F in repairVitreous china1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern including all necessary accessories like rag bolts, gel gasket etc. (excluding flushing cistern & flush pipe) complete including plastic water closet seat closed pattern with flat bottom and cover and mild steel chromiunm plated or aluminum hinging devicecomplete all as specified and as directed. 40 Taking up or down 15 mm dia steel tubing and connections including cleaning for refixing or removal to storecomplete all as specified and as directed. 41 S&F 15 mm bore galvanised steel water tubing medium grade with necessary fittings as required and fixed to walls, ceiling or laid in floors etc complete all as specified and as directed. 42 Taking up or down 20 mm dia steel tubing and connections including cleaning for refixing or removal to storecomplete all as specified and as directed. 43 S&F 20 mm bore galvanised steel water tubing medium grade with necessary fittings as required and fixed to walls, ceiling or laid in floors etc complete all as specified and as directed. 44 S&F in repair Mild steel chromium plated grating 125 mm dia and fixed to Nahani trapcomplete all as specified and as directed. 45 S&F in repair5 mm thick bevelled edge looking mirror of selected quality glass mounted with SS studscomplete all as specified and as directed. 46 S&F 1000 litres rotational moulded polyethylenewater storage tanks(cylindrical vertical with closed top) hoisted and fixed in positionincluding 2 Nos GI union, check nut and 25mm PTMT float Valve, overflow and washout GI medium grade pipe 15mm dia,15 mm bore gate valve & Nippule including dismantling of old unserviceaablePVC tank and removing to storecomplete all as specified and as directed. 47 Demolition of Mud/mud puska in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof)complete all as specified and as directed. 48 Dismantling of brick tiles laid bedded and pointed in any morter or brick tiles on roof , floors, channels, kerbs, aprons etc in any position not otherwise specifically provided for complete all as specified and as directed. 49 M&L 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in roof padding, benchingetc, surface finished even and faircomplete all as specified and as directed. 50 M&L for 10mm thick renderingin cement mortar 1:4 over concrete surfaces of roof, mixed with liquid water proofing compound as per manufacturerrs instruction, surfaces finished even and smooth without using extra cementcomplete all as specified and as directed. Note:- Water proofing compound shall be measured and paid separately under respective item. 51 M&L for cleaning the roof surfcae from dust /dirt and any other foreign materials and applying a coat of bituminius primer @ 0.30 liter per square meter uniformity after the surfaces fully driedcomplete all as specified and as directed. 52 M&L for applying evenlya tack coat of industrial bitumen of grade 85/25 conforming to IS 702at the rate of1.20 Kg/Sqmcomplete all as specified and as directed. 53 M&L for APP basedpolymeric water proofing membrane minimum weight 3 Kg/ Sqm and minimum 3mm thick reinforced with polyster non wove fabrick (Weight not less than 150gms/Sqm or as per IS),laid over hot bitumen surface by torch application under supervision of manufacturers technical supervisor complete all as specified and as directed.Note:- Membrane shall be laid with 100mm side/end lap on prepared surface as per manufacturer instruction. Work shall be carried out strictly by the technical tradesmen and supervision of technical staff of manufacturer. 54 M&L 40mm thick brick tiles laid over roof treatment,jointsgrouted flush in cement mortar 1:3 mixed with and including 5% curde oil by weight of cement over including 15mm thick screed bed in cement mortar (1:6) mixed withliquid water proofing compound as per manufacturers specification complete all as specified and as directed. 55 Supply only liquidintegral water proofing compund of Make Dr Fixit Pidipfoof LW+ or equivalent as approved complete all as specified and as directed.. 56 M&L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in cills, bencing and other similar bands, plinth courses, parapets, coping, bed plates and the like inclduing weathering, slightly rounded or chamfered angles and throating,surfacefinished even and smoothinclduing necessaryuse and waste of form workcomplete all as specified and as directed. 57 M&L for point wiring using approved colour coding as per IS, with Zero Halogen Flame retardant (HFFR), smoke free, non toxic, non corrosive installation cable with UNILAY construction copper conductor 1.5 Sq mm (nominal area), single core,insulated and unsheathed stranded cable 1100 Volts grade ISI-694 markedin and including heavy duty, electric resistance welded (ERW)dia not less than 15 mmstove enameled surface mounted conduit,heavy duty ISI marked as per IS:9557 (Part I) 1980 forlight points controlled by one Switch , includingHFFR insulated unsheathed unitary construction copper conductor 1.5 Sqmm nominal cross sectional area wire as earth continuity conductor and connected to main earth dolly complete all as specified and as directed. 58 S&F flame proof switch rotary type with termination box in LM6, 16 Amp, single pole 250V complete all as specified and as directed. 59 S&F LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed. 60 M&L for point wiring using approved colour coding as per IS, with Zero Halogen Flame retardant (HFFR), smoke free, non toxic, non corrosive installation cable with UNILAY construction copper conductor 4.0 Sqmm (nominal area), single core,insulated and unsheathed stranded cable 1100 Volts grade ISI-694 markedin and including heavy duty, electric resistance welded (ERW)dia not less than 15 mmstove enameled surface mounted conduit,heavy duty ISI marked as per IS:9557 (Part I) 1980 forlight points controlled by one switch , includingHFFR insulated unsheathed unitary construction copper conductor 2.5 Sqmm nominal cross sectional area wire as earth continuity conductor and connected to main earth dolly complete all as specified and as directed. 61 S&F Flame proof switch socket and plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earthcomplete all as specified and as directed. 62 M&L for sub main wiring using approved colour coding as per IS, with Zero Halogen Flame retardant (HFFR), smoke free, non toxic, non corrosive installation cable with UNILAY constructiontwo run of copper conductor 4 Sqmm (nominal area), single core,insulated and unsheathed stranded cable 1100 Volts grade ISI-694 marked and including heavy duty, electric resistance welded(ERW)dia not less than 15 mm stove enameled surface mounted conduit,heavy duty ISI marked as per IS:9557 (Part I) 1980h , includingHFFR insulated unsheathed unitary construction copper conductor 4 Sqmm nominal cross sectional area wire as earth continuity conductor omplete all as specified and as directed.Note:- Two run of 4 sqmm copper cable,one run of steel conduitand one run of 4 sq mm copper cable earth wire shall be measured as one unit.. 63 S&F MCB 5 to 32 Amp, single pole , C curvecomplete with connection testing and commissioning complete all as specified and as directed. 64 S&F MCB 40 to 63 Amp, single pole and neutral , C curvecomplete with connection testing and commissioning complete all as specified and as directed. 65 S&FMCB DB flame proof type 8 way ,220 V ,50 Hz, comprising 200 Amps bus bar ,neutral link,earth link complete all as specified and as directed. 66 M&L Earthing complete with galvanised steel earth plate electrode 600mmx600mmx6mm thick, buried directlyin ground(earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4.0 mm dia (upto 7.5 M in length from earth plate) by means of bolts, nuts, check nuts and washers of galvanisediron or steel ,filling adequate quantity of charcoldust and common salt all as shown in electrical plate No 3 of SSR Part-2009, connected to earthing with DBs all as specified including excavation and earth work in any type of soil, PCC 1:3:6 type C-1 using 20mm graded stone aggregate in chamber &cast iron earthingpit cover having size 250mmx250 mm, weight not less than 7.5 Kg as per relevant ISincluding frame, 15mm dia GI pipe light grade for earth lead protection, 20mm dia GI medium grade pipe for watering , water funnel etc complete all as specified and testing on completion. 67 S&F 25 mm diarigid steel conduit, welded with necessay fitting as requiredcomplete all as specified and as directed. 68 S&F single pole and neutral enclosure with a two pin and earth plug and socketcomplete with one single pole MCB 20 Amp complete all as specified and as directed. 69 S&F mild steel slotted cable tray with accessories of size 300 mm x 50 mm x1.6 mm as per IS 9537:1983 complete all as specified and as directed. 70 S&F Fire alarm control panel complying with BS EN 54 single loop panel of capacity from 99 detectors& 99 modules upto 200 detector and modules including public addressible system and battery backup in control panel complete all as specified and as directed. 71 S&F Detectors complying with and type certified to EN-45 addressable type multisensor detector with heat and smoke combination complete all as specified and as directed. 72 Supply , installation, testing and comissioning of addressable manual call point resettable type with dust protected design suitable for use in standard environment condition complete all as specified and as directed. 73 Supply , installation, testing and comissioning of fire alarm sounders/sirens electronic type single stage continuos normal operation for atlest 50 minute with sound level 65 DB to 120 DB measured at 1.5 m with sound output variation of +5DB 500 m range complete all as specified and as directed. 74 S&F1.5 sqmm two coreFRLS, PVC with mylertape insulated copper conductor armoured cable complete all as specified and as directed. 75 S&F 20 mm dia rigid steel conduit weldedwith necessay fitting as requiredcomplete all as specified and as directed. 76 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking creditincluding making good disturbed surfaces of walls, floors etc to match with the existing complete all as specified and as directed. 77 Taking down old unserviceable light fittings conventional type from wall surface or ceiling or any position and making good the disturbed surfacesto match with the existing complete all as specified and as directed. 78 Taking down carefully unserviceable DB any type or size disconnecting and making good disturbed surfaces to match with the existing complete all as specified and as directed. 79 Taking down carefully unserviceable MCB SP/SPN/Isolator of any rating or size complete all as specified and as directed. 80 Taking down old unserviceable sub main wiring of anyruns and any sizes from any position including, making good disturbed surface of wall, ceiling etc to match with the existing complete all as specified and as directed.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 10-12-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-12-2024
2 17-12-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-12-2024
3 28-11-2024 CORRIGENDUM NO 1 BOQ 10-12-2024
4 28-11-2024 CORRIGENDUM NO 1 Date 10-12-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-
Disclaimer :