| 1 | Supply, Installation,Testing and commissioning of 100% Inverter VRF units of 12 HP (LIBRARY) complete with Inverter Scrollcompressor fitted with Conentrated winding, air cooled condenser with low noise fan having interconnected control wiring and refrigerant piping housed in compact housing duly powder coated, Conformal Coating on PCB, Hydrophilic Blue Fins, Twin Accumulator & Two Compressors in each Outdoor Unit. All units are Cooling & Heating both with Eco Friendly Refrigerant(R-410a). Unit should deliver 100% capacity without deration upto 43°C Ambient Temperature.Operating Outdoor Ambient Temperature Range Cooling 10°C to 56°C & for Heating -10°C to 24°C. IPLV should be more than 6.7 complete all as specified and directed by Engg in charge.Note: VRF Installation work to be execute by OEM. All Drawings & Heat Load should be Vetted through OEM only. MOU with OEM shall be submitted by the contractor after acceptance of contract but before commencement of work.Make: Daikin/ LG/ Bluestar |
| 2 | All as per item No 1.00 above but for 28 HP (LIBRARY) complete all as specified and directed by Engg in charge. |
| 3 | All as per item No 1.00 above but for 16 HP (Anchor Bar) complete all as specified and directed by Engg in charge. |
| 4 | Supply, installation, testing and commissioning of Ductable Units capacity of 9.0 TR (3400 CFM) (Library) with evaporator coil, fan and Fan motor, corded remote control, and necessaryaccessories etc suitable for operation on 230 V +- 10% 50 Hz single phase AC supply as required complete all as specified and directed by Engg in charge. |
| 5 | Supply, installation, testing and commissioning of Verticool Units capacity of 4.0 TR (1060 CFM) (Anchor Bar) with evaporator coil,fan and Fan motor,cordless remote control, and necessaryaccessories etc suitable for operation on 230 V +- 10% 50 Hz single phase AC supply as required complete all as specified and directed by Engg in charge. |
| 6 | Supply, installation, testing and commissioning ofFloor Mounted AHU Units capacity of 22.0 TR (8800 CFM) (Library) with evaporator coil,fan and Fan motor,corded remote control, AHU Kit (Control Kit + Expansion kit) and necessaryaccessories etc suitable for operation on 230 V +- 10% 50 Hz single phase AC supply for Kit & 480V - % 50 Hz Three phase AC supply for AHU as required complete all as specified and directed by Engg in charge.Make: Zeco, Edgetch, Bluestar, Wave |
| 7 | S&F refrigerantY-Jointfor CombiningOutdoorandIndoorUnitsrequiredfordistributionof refrigerant in copper piping as per final approved drawing which will be submitted by OEM complete all as specified and directed. |
| 8 | Supply, installation, testing and commissioning high pressure interconnecting refrigerant pipe of size 9.5mm with 13mm thick insulation including civil work like wall opening for copper and drain pipe for VRF system with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between indoor & outdoor units as per specifications. All Piping intall on cable trays with cover for outdoor locations as per OEM recommendations and PVC sleeves shall be provided wherever pipe is crossing the wall. Food grade nitrogen shall be used while makingbrazing joints complete all as specified and directed by Engg in charge.Make: Mandev, Maxflow, Rajco |
| 9 | All as per item No 8.00 above but size 12.7 mm with 13 mm thick insulation complete all as specified and directed by Engg in charge. |
| 10 | All as per item No 8.00 above but size 15.9 mm with 13 mmthick insulation complete all as specified and directed by Engg in charge. |
| 11 | All as per item No 8.00 above but size 19.1 mm with 13 mmthick insulation complete all as specified and directed by Engg in charge. |
| 12 | All as per item No 8.00 above but size 22.2 mm with 19 mmthick insulation complete all as specified and directed by Engg in charge. |
| 13 | All as per item No 8.00 above but size 28.6 mm with 19mm thick insulation complete all as specified and directed by Engg in charge. |
| 14 | All as per item No 8.00 above but size 34.9 mm with 19mm thick insulation complete all as specified and directed by Engg in charge. |
| 15 | All as per item No 8.00 above but size 38.1mm with 19mm thick insulation complete all as specified and directed by Engg in charge. |
| 16 | Supply and fixing in position the 32mm dia of PVC (UPVC quality) pipes, cut in required lengths and joined with PVC cement and also providing and fixing in position the necessary \"U\" trap elbows, tees, and reducer and all types of fittings. Cost to include all necessary as required. Necessary Wall cutting and making the wall good and its cost should be included. The pipe to be insulated by 9mm thick nitrile rubber thermal insulation of class 0 category complete all as specified and directed by Engg in charge. |
| 17 | Supply, fixing, testing and commissioning of 2 Core x 0.75mm² control wiring (Sheilded Wire) from outdoor , indoor units to the central controllerwith all necessary accessories to make it functional as per OEM Recommendation complete all as specified and directed by Engg in charge.Make: PolyCab, Havells, Finolex |
| 18 | Supply and fixing of MS Stand as per OEM Recommendation and Placing of Outdour Unit on MS Stand of C Channel complete all as specified and directed by Engg in charge. |
| 19 | Supply, Charging of Refrigerant Gas R410a as per OEM Recommendation (Make:- SRF Floron, Honeywell & Dupont) complete all as specified and directed by Engg in charge. |
| 20 | Supply and fixing of 125mm deep AntivibrationFlexible Jointsmade out of imported fire retardant fabric with extruded aluminium frame/ flange on both sides for Outdoor Units complete all as specified and directed by Engg in charge. |
| 21 | Supply , assembly and erection GI sheet of 25 Gauge rectangular/ square duct made out of \"L\" shaped hollow profile, duly factory boxed, including all accessories such as corner, Cleat , Carrige bolt, Gasket and appropriate sealant on langitudinal joints etc complete including necessary MS Channels, Gurder supports as approved by Engr-in-charge including making of hole in any type of wall and making good with plastering work , masonry work and necessary MS channel supports complete all as specified and directed by Engg in charge. |
| 22 | All as per item No 21.00 above but size 22 Gauge complete all as specified and directed by Engg in charge. |
| 23 | Supply & erection of 19 mm thick nitrile duct insulation with Aluminum foil. The thermal insulation shall be 25 mm thick non-fibrous, fire retardant, closed cell, tri- dimensional chemically crosslinked polythylene foam, confirming to class O\" for fire propagation and class 1 for surface spread of flame & factory laminated aluminum foil complete all as specified and directed. |
| 24 | Supply and fixinginsulation acoustic lining of supply air ducting complete with GI frame , tissue paper , 26 Guage perforated AL Sheet25mm thick of density 32 kg/cum fiber glass insulation complete all as specified and directed. |
| 25 | S&F of Acoustic treatment/ lining of area of AHUroom with 22 Gauge, GI channels of 50x50 mm size fitted at 600x600mm girds, fitted with 50mm thick, 32 Kg/cum fibber glass insulation, coveredwithfibberglasstissueand24GaugeAluminiumperforatedsheetasrequired,Thejoint shall be with minimum overlapping of 75mm with 30mmx 3mmaluminium strip covering, All corners shallbeprovidedwith20x20x2mmaluminiumanglewithstainlesssteelcountersunkscrews complete all as specified and as directed. |
| 26 | SupplyandfixingoffireproofdoublelayeredcanvasclothconnectionforAHUoutlet includinginspectionopeningcompletewithflangesmadeoutof22GSSSheetonbothsidefor connection to AHE and duct with nuts , bolts complete all as specified and directed. |
| 27 | Supply, installation, testing and commission of UL-555 motorized fire dampers complete with smoke detector/ thermister linkage etc in Supply Air Ducts as required for operation complete all as specified and directed. |
| 28 | Supply, installation, testing and commission of Actuator with control panelSupply Air Ducts as required for operation complete all as specified and directed. |
| 29 | Supply, installation ,testing ofsupply air Grillsand without volume control dampers, power coated , extruded aluminium construction complete all specified and as directed. |
| 30 | Supply, installation ,testing ofsupply air Grillsand volume control dampers , power coated , extruded aluminium construction complete all specified and as directed. |
| 31 | M&L for control wiring with 4 core X 1.5sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694 with on Cable Tray complete all as specified and directedMake : Finloex/Havells/Polycab(Note : Four run of wire with PVC conduit will be considered as one Length.) |
| 32 | M&L for control wiring with 4 core X 16sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694 with on Cable Tray complete all as specified and directedMake : Finloex/Havells/Polycab(Note : Four run of wire with PVC conduit will be considered as one Length.) |
| 33 | M&L for control wiring with 4 core X 10sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694 with on Cable Tray complete all as specified and directedMake : Finloex/Havells/Polycab(Note : Four run of wire with PVC conduit will be considered as one Length.) |
| 34 | M&L for control wiring with 4 core X 6sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694 with on Cable Tray complete all as specified and directedMake : Finloex/Havells/Polycab(Note : Four run of wire with PVC conduit will be considered as one Length.) |
| 35 | M&L for control wiring with 4 core X 4sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694 with on Cable Tray complete all as specified and directedMake : Finloex/Havells/Polycab(Note : Four run of wire with PVC conduit will be considered as one Length.) |
| 36 | M&L for control wiring with 3 core X 2.5sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694 with on Cable Tray complete all as specified and directedMake : Finloex/Havells/Polycab(Note : Four run of wire with PVC conduit will be considered as one Length.) |
| 37 | M&L for control wiring with 3 core X 1.5sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694 with on Cable Tray complete all as specified and directedMake : Finloex/Havells/Polycab(Note : Four run of wire with PVC conduit will be considered as one Length.) |
| 38 | S & F MCB SP, 240 Volts, 5 to 40 Amps 240 V/415 V, 50 Hz, 10 kA complete all as specified and directed. |
| 39 | S & F MCB TPN, 40Amps 240 V/415 V, 50 Hz, 10 kA complete all as specified and directed. |
| 40 | S & F MCB TPN, 63Amps 240 V/415 V, 50 Hz, 10 kA complete all as specified and directed. |