| 1 | PART \"A\" BUILDING WORKEarth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m |
| 2 | Earth filling with available surplus soil excavated from foundations and taken only from outside of building plinth in layers not exceeding 20cm in depth, consolidating each deposited layer including ramming and watering and consolidation with lead up to 50 m and lift upto 1.5 m. |
| 3 | Carriage of Materialsby mechanical transport including loading, unloading and stacking : Earth (Rate for lead5 km.) |
| 4 | Supplying Chlorpyriphos/ Lindane emulsifiable concentrate of 20% in sealed containers including delivery as specified. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinthlevel :1:4:8 (1 Cement : 4 fine/ coarse sand : 8 graded stone aggregate 40 mm nominal size). PCC |
| 6 | Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. |
| 7 | Columns, Pillars, Piers, Abutments, Posts and Struts up to plinth level |
| 8 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 9 | Suspended floors, roofs, landings, balconies and access platform |
| 10 | Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete. Hot rolled deformed bars |
| 11 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level : 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). (As per design mix) |
| 12 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto two stories excluding cost of centring, shuttering, finishing and reinforcement : 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) (As per design mix) |
| 13 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto two stories excluding cost of centring, shuttering, finishing and reinforcement : 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 14 | Random rubble stone masonry with hard stone in foundation and plinth : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 15 | Random rubble dry stone Kharanja (soling) under floor. |
| 16 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stoneaggregate 20 mm nominal size). Under flooring PCC |
| 17 | Brick work with FPS bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 18 | Half brick masonry with FPS bricks of class designation 75 in superstructure above plinth level upto two stories. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 19 | Supplying and fixing stone lintels / bed plates of approved quarry rough dressed in cement mortar 1 : 4 :Upto 15 cm. thick. |
| 20 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). Cement Concrete Dal |
| 21 | Extra for providing and mixing water proofing material in cement concrete work @ 1 kg per 50kg of cement. |
| 22 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto two stories, excluding the cost of centring, shuttering and finishing : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) (coping for parapat wall.) |
| 23 | Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 20 mm cement plaster of mix : 1:4 (1 cement : 4 fine/ coarse sand) |
| 24 | Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 12 mm cement plaster of mix : 1:4 (1 cement : 4 fine/ coarse sand) Ceilling plaster |
| 25 | P & F 1st quality Vitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in colour, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete.Size 450 mm X 450 mm |
| 26 | Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth completeBirla/J.K./Nerolac or ISO. As per direction of Engineer in charge. |
| 27 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shad. New work (two or more coats) over and including priming coat with cement primer. |
| 28 | 26.22 Providing and fixing double paitam (rebated) stone doors windows and ventilator frames of approved quality in cement sand mortar 1:4:(Size 125 X 100 MM) |
| 29 | Providing and fixing factory made ISI marked steel glazed doors,windows and ventilators side /top /centre hung with beading and allmembers such as F7D, F4B, K11 B and K12 B etc. complete ofstandard rolled steel sections, joints mitred and flash butt weldedand sash bars tenoned and rivetted with 15x3mm lugs, 10cm long,embedded in cement concrete blocks 15x10x10cm of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominalsize) or with wooden plugs and screws or rawl plugs and screws orwith fixing clips or with bolts and nuts as required, includingproviding and fixing of hinges, pivots, float glass panes with glazingclips and special metal sash putty of approved make and a primingcoat of approved steel primer excluding the cost of metal beadingand other fittings except necessary hinges or pivots complete as perapproved design. |
| 30 | Providing and fixing M.S. round or square bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows. |
| 31 | Providing and fixing GI wire gauge of average width of aperture 1.56mm with wire of 0.45mm to existing steel door, window shutter frames with necessary M.S. strip beading 20x3mm with suitable screw at not exceeding 150mm distance etc. complete. |
| 32 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including black enamelled ISI marked M.S butt hinges with necessary screws. Second class teak wood 35 mm thick |
| 33 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution. |
| 34 | Providing and fixing fully panelled/partly panelled/ double leafshutter frame for doors as per approved design and drawings withapproved ordinary C.P./ oxidised steel fittings as per Annexure - \"A\"and width of styles & top rails of 100mm and lock rails width of150mm and bottom rails of 200mm width including teak woodbeading of size 19mm x 12mm on both faces complete : |
| 35 | PART \"B\" ELECTIRC WORKWiring of light point/ fan point/ exhaust fan point/ call bell point asper PWD specification for electrical Works with ISI marked 1.5 sq.mm nominal size FR PVC insulated unsheathed flexible copperconductor 1.1 kV grade ( IS: 694) and 1.5 sq. mm nominal size FRPVC insulated unsheathed flexible copper earth conductor 1.1 kVgrade (IS:694) in recessed ISI marked ( IS:9537 P - II ) rigid steelconduit & it\"s all accessories, round tiles,18 SWG G.I.box with earthterminal, 6 A switch, 3 pin ceiling rose/ Lamp holder / 3 pointConnector, 3.0 mm thick ISI marked phenolic laminated sheet, pvcbushes, check nuts, Al. alloy/ cadmium plated iron screws 20 mmcup washers etc. All as per pre approved by Engineer in charge,making connections, testing etc. complete as required. Forspecification of copper Conductor, Phenolic Laminated sheet\"s &Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 .For additional technical parameters of products/ work , referAnnexure \"A\" attached with this BSR .Short point (up to 3 mtr.) |
| 36 | Medium point (up to 6 mtr.) |
| 37 | Long point (up to 10 mtr..) |
| 38 | Providing & Fixing of 240/415 V AC MCB with positive isolation ofbreaking capacity not less than 10 KA (B/ C tripping characteristic asper type of load and site requirement) 4KV impulse withstandvoltage, as per PWD specification for electrical Works with ISImarked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC, minimum phase termination capacity of35sq.mm. , conductorline load reversibility, label holding facility , IP20 contact protection and fitted with existing distributionboard/sheets, min. operation 20,000 upto 32 A rating and 10,000upto 63 A, 5000 for 80 A rating including making connections,testing etc. as required. . OEM shall have submit NABL / CPRI /ERDA accrediated lab test reports before execution & All as perpre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \"A\" attached withthis BSR . Single pole MCB 6 A to 32 A rating |
| 39 | Double pole MCB 6 A to 32 A rating |
| 40 | Providing & Fixing of 240/415 V Residual current circuit breaker(RCCB) as per PWD specification for electrical Works with ISImarked (IS:12640-1) / conforming to IEC 61008 -1 , rated conditionals/c current of 10 KA, truly current operated and shall operate onCBCT mechanisum, provision for pad lock, min. operation 10,000upto 63 A rating and 5000 for 100 A rating, minimum phasetermination capacity of 50 sq.mm. rigid wire , IP 20 contactprotection with existing distribution board / sheet including makingconnections, testing etc. as required.OEM shall have submit NABL /CPRI / ERDA accrediated lab test reports before execution & Allas per pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \"A\" attached withthis BSR .Two pole 30 mA sensitivity 16/25 A rating |
| 41 | 32/40 A rating |
| 42 | Providing & Fixing of IK09 recessed/surface mounting heavy dutyhorizontal type sheet steel not less then 1.2 mm thick Distributionboard as per PWD specification for electrical Works ISI markedconforming to IS-13032 & IS-8623 / conforming to IEC 61439-3.Phosphatised/ powder painted complete with suitable ratinginsulated copper bus bar, shorting link , neutral link, earth link ,connecting wire of suitable rating and din bar,masking sheet,including making internal DB terminations with copper lugs and withdetachable gland plate, including making connections, testing etc. asrequired.OEM shall have submit NABL / CPRI / ERDA accrediatedlab test reports before execution & All as per pre approved byEngineer in charge. For additional technical parameters of products/work , refer Annexure \"A\" attached with this BSR .IP-43 Double door (single phase),6 Way (6 O/G +2 I/C ) |
| 43 | IP-43 Double door (Three phase), 4 Way ( 12 O/G + 8 I/C ) |
| 44 | Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pinceiling roses as per PWD specification for electrical Works, madeout from industrial grade Polycarbonate or fire resistant ABSmaterial, brass terminal & captive screws including makingconnection testing etc. as required. All as per pre approved byEngineer in charge. For additional technical parameters of products/work , refer Annexure \"A\" attached with this BSR . |
| 45 | Providing & Fixing of ISI marked (IS:1258) 6 amp batten/anglelamp holder as per PWD specification for electrical Works, madeout from industrial grade Polycarbonate or fire resistant ABSmaterial, brass terminal & captive screws including makingconnection testing etc. as required. All as per pre approved byEngineer in charge. For additional technical parameters of products/work , refer Annexure \"A\" attached with this BSR . |
| 46 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured / Armoured copper cable of 1.1 KV grade as per PWDspecification for electrical Works in existing RCC / Hume /Stoneware / PVC pipe/ open duct/cable trench with filling ofexcavated earth in trench , on existing cable trays or on surface etc.including making necessary connection, testing etc. as required ofsize and as per points (a), (b), (c), mentioned below:-(a) Copper conductor of electrlytic grade copper, purity >99.97 %ISI marked as per IS:1554 P-I / IS :7098 P - I(b) conductor shall made of copper rods confirming to IS 613-1964,IS 3975-1999 for armouring of cables in armoured cable items , IS5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures(c) OEM Must have ISO 9001 & 14001 certifications & its own inhouse NABL lab setup for all testing facilities for cables .Appropriate type test certificate / OEM test report shall be submitted. All above as per pre approved by Engineer in charge. Foradditional technical parameters of products/ work , refer Annexure\"A\" attached with this BSR . |
| 47 | P/Laying ISI marked P.V.C. insulated submersible cable confirmingto IS:694 with flexible copper conductor including making connectionetc. as required\"10.0 Sq.mm 3 core flat |
| 48 | Plate Earthing as per PWD specification for electrical Works as perIS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x6.0mm by embodying 3 to 4 mtr. below the ground level with 20mm dia. G.I. \"B\" class watering Pipe ,including all accessories likenut, bolts, reducer, nipple, wire meshed funnel, and Heavy dutyweather proof poly-propylene earth pit chamber with lockable Jamfree lid suitable for safe working load 5000 Kg or more of size TopDia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to300 mm. and embodying the pipe complete with alternate layerssalt and coke/ charcoal, testing of earth resistance for value of 5ohms or less as required & must record by engineer in chargeduring site visit and ensure to enter in measurment book. All as perpre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \"A\" attached withthis BSR . |
| 49 | Supply & Laying following size earth wire in horizontal or vertical runin ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu thimble etc. as required. All as perpre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \"A\" attached withthis BSR . 6 SWG copper Wire |
| 50 | Providing & Fixing of copper tape 20mm x 3 mm on parapet orsurface of wall fixed with porcelain or bakelite insulator (SP-35) invertical/horizontal run as required. All as per pre approved byEngineer in charge. For additional technical parameters of products/work , refer Annexure \"A\" attached with this BSR , 20mm x 3mm copper strip |
| 51 | Providing & Fixing of IP20 SMD Mid Power LED batten typeintegrated light fixture made from polycarbonate /extrudedaluminium powder coated housing with in built driver , PowerConsumption of 18W/20W ,system lumen efficacy ≥ 120 lm/Wattoutput, internal surge protection of 2.5 KV with Short & Open circuitprotection ,THD < 10% ,p.f.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till lifeends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As perANSI Bin) , maximum power consumption should not more than thespecified rating and Fixture shall be of BIS standard and trademark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing.OEM must have its own in house NABL lab setup for all testingfacilities for LED fixtures. (LM79/LM80) certificate / Report fromOEM shall be submitted. All as per pre approved by engineer incharge . foe additional technical parameters of product/ work, referAnnexure \"A\" attacheded with this BSR. 4\" LED Tube shape fixture 18/20 W (Extruded Al Base) |
| 52 | Providing & Fixing of Ballast for existing FTL / CFL fixture asrequired complete in all respect. All as per pre approved by Engineerin charge. For additional technical parameters of products/ work ,refer Annexure \"A\" attached with this BSR . Vacuum pressure impregnated copper ballast for 9/11/13/18 wattCFL |
| 53 | Providing & Fixing of Heavy duty capacitor start, copper woindDouble ball bearing 900/1400 RPM single phase Exhaust fan asper PWD specification for electrical Works, conforming to IS:2312ISI marked in existing opening including making connections testingetc. as required. OEM shall be an ISO certified company.Appropriate OEM test certificate shall be submitted by contractor. Allas per pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \"A\" attached withthis BSR . 300 mm sweep(900/1400 RPM) |
| 54 | Providing & Fixing of ISO Certified company made BEE Approvedcopper wounded 1200 mm sweep BLDC technology power savingceiling fan with longer life span and low maintenance 5 star ratedwhich can withstand on votage fluctuations from 140 volts to 240volts ,power factor not less then 0.9 , service value (CMM/W)minimun 6.85 , air delivery minimun 215 CMM, speed 350 RPM (tolerance as per IS:374 2019 ) THD less then 10% and completewith down rod up to 30 cm with secondary support safety cable ,cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductormaking connection testing etc. as required. Appropriate OEM testcertificate shall be submitted by contractor. All as per pre approvedby Engineer in charge. For additional technical parameters ofproducts/ work , refer Annexure \"A\" attached with this BSR .Without Remote |
| 55 | Providing and fixing of non modular power plug point accessoriesas per PWD specification for electrical Works with 18 SWG G I boxof size 175 x 100 x 60 mm with earthing terminal/connector onrecessed/surface with suitable size phenolic laminated sheet (IS :2036 - 1995) cover including cost of 16 amp. Switch (IS :3854) and3/6 pin 16 amp. socket outlet [ as per detailed in respective item inBSR], making connection , testing , etc. as required. All as per preapproved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \"A\" attached withthis BSR . |