| 1 | Providing and fixing False ceiling of 12mm thick gyp board sheets inclusive of all hangers, edge members and other clips complete, with sheets fixed with proper Philip fastner by power drills and joints duly finished ensuring level in line, completewith putty, primer and painting of approved make and colour . Cost includes cutouts for electrical fittings, materials, labour, T&P etc complete as per direction of the Engineer-in-charge. |
| 2 | Providing and applying 2 coats ofPlastic Emulsion Paint of approved quality and shade overwall primer of approved quality to surfaces (interior) including throughly brushing the surface free from foreign materials, sand papering smooth the intermediate coats,including of all materials, labour, conveyance, royalties, scaffolding, watering, curing, sundries, tools and plants etc as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use) |
| 3 | Providing, fitting and fixing full height wooden paneling to walls and columns wherever necessary from floor lvl to ceiling ht as per drawing/design made out of 50.8mmx25.4mmx1.34mm thick Aluminium rectangular sections placed@ 600mm c/c both ways on grid, on top of grid 12mm marine ply (conforming to IS code :5509) to be finished with 1mm thk Laminate of approved shade and colour finished with melamine polish as per design/drawing or as directed by the Architect/Engineer-in- Charge. The rate includes cost of cutouts for electrical switches, light fixtures, wall bracket fans if any, all complete with materials, labour, T&P, taxes etc. |
| 4 | Providing, fitting and fixing 450mm width and 750mm-1200 mm height storage unit as per detail drawings/design providedwith drawers and shelves having openable doors. Storage unit top will be of 19mm thickply (conforming to IS code :5509) with 1.0mm thick laminate of approved make & shade, openable shutters are made out of 19mm thick and all horizontal & vertical members of drawers & shelves are 12mm thickply (conforming to IS code :5509), all exposed areas finished with 1.0mm thick laminate of approved make & shade & inside areas finished with .5mm thick white laminate of approved make and shade and provided with drawer sliders, S.S. autohinges, S.S. locks, handles and other necessary hardwares and accesories of approved make etc complete in all respect as per detail drawings/design or Architect/Engineer-in-charge. |
| 5 | Providing, fitting and fixing 450mm-600 width and 2100mm height storage unit as per detail drawings/design providedwith drawers and shelves having openable shutters. Storage unit top, bottom & openable shutters are made out of 19mm thickblock board and all horizontal & vertical members of drawers & shelves are 12mm thickply (conforming to IS code :5509), all exposed areas finished with 1.0mm thick laminate of approved make & shade & inside areas finished with 0.5mm thick white laminate of approved make and provided with drawer sliders, S.S. autohinges, S.S. locks, handles and other necessary hardwares and accesories of approved make etc complete in all respect as per detail drawings/design or Architect/Engineer-in-charge. |
| 6 | Providing, fitting and fixing 450mm-600 width and 2100mm height storage unit as per detail drawings/design providedwith drawers and shelves having openable shutters up to Height 1000-1200 mm and other part Open Rack Storage. Storage unit top, bottom & openable shutters are made out of 19mm thickblock board and all horizontal & vertical members of drawers & shelves are 12mm thickply (conforming to IS code :5509), all exposed areas finished with 1.0mm thick laminate of approved make & shade & inside areas finished with 0.5mm thick white laminate of approved make and provided with drawer sliders, S.S. autohinges, S.S. locks, handles and other necessary hardwares and accesories of approved make etc complete in all respect as per detail drawings/design or Architect/Engineer-in-charge. |
| 7 | Providing, fitting and fixing 450mm-600 width and 2100mm height storage unit as per detail drawings/design providedwith drawers and shelves having openable shutters up to Height 1000-1200 mm and other part 6mm Toughtened Glass Track/Shutter. Storage unit top, bottom & openable shutters are made out of 19mm thickblock board and all horizontal & vertical members of drawers & shelves are 12mm thickply (conforming to IS code :5509), all exposed areas finished with 1.0mm thick laminate of approved make & shade & inside areas finished with 0.5mm thick white laminate of approved make and provided with drawer sliders, S.S. autohinges, S.S. locks, handles and other necessary hardwares and accesories of approved make etc complete in all respect as per detail drawings/design or Architect/Engineer-in-charge. |
| 8 | Providing, fitting and fixing 450mm-600 width and 2100mm height storage Rack unit as per detail drawings/design providedwith 8mm Toughtened Clear glass Rack up to Height 2100-2400 mm with Stainless Steel Frame and other necessary hardwares and accesories of approved make etc complete in all respect as per detail drawings/design or Architect/Engineer-in-charge. |
| 9 | DISPLAY Table :- |
| 10 | Providing and fixing 12 mm thick frameless toughened etched glass Partition of approved brand with machine polished edgesincludingtop & bottom patches,QBPF-3(TOP 1500mm long),QBPF-3(BOTTOM 1500mm long), as approved by the EIC with all arrangements and making necessary holes etc. all complete, including all cost of labour, material, conveyance, T&P etc.as per direction of Engineer-in-charge |
| 11 | P/F 12 mm thick frameless toughened glass door shutter including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. |
| 12 | Dismentaling of shelves and Shutter repairing |
| 13 | Wiring for light point/ fan point/ exhaust fan/wall fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box including supplying the same and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 14 | Group B |
| 15 | Group C |
| 16 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire for 6A PP looping |
| 17 | 2 X 2.5 sq. mm + 1 X 1.5 sq. mm earth wire for 15A PP & Switch Boards & Computer points |
| 18 | 2 X 4.0 sq. mm + 1 X 2.5 sq. mm earth wire for AC |
| 19 | 4 X 4 sq. mm + 2 X 2.5 sq. mm earth wire for L .DB |
| 20 | 4 X 6 sq. mm + 2 X 4 sq. mm earth wire for P.BDB,VRF & UPS WIRING |
| 21 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire for P.BDB,VRF AC |
| 22 | Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 23 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 24 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 25 | 25 mm |
| 26 | 32 mm |
| 27 | Supplying and fixing metal box of 1.63 mm thick following sizes (nominal size) on surface or in recess without cover including cutting the wall and making good the same in case of recessed conduit,also including painting etc as required. |
| 28 | 100 mm X 100 mm X 60 mm deep |
| 29 | 150 mm X 75 mm X 60 mm deep |
| 30 | 200 mm X 125 mm X 60 mm deep |
| 31 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 32 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3nos 3 pin 5/6 amps modular socket outlet with 2nos5/6 amps modular switch, connection etc. as required. |
| 33 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2nos 3 pin 5/6 amps modular socket outlet with 2nos5/6 amps modular switch, connection etc. as required. |
| 34 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 35 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 amps modular switch, connection etc. as required. |
| 36 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 amps modular Socket , connection etc. as required. |
| 37 | Supplying and fixing of Telephone socket out let with suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing , connection etc. as required. |
| 38 | Supplying and fixing of TV antenna socket out let with suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing , connection etc. as required. |
| 39 | Installation, testing and commissioning of wall bracket /ceiling fittings /LED down light of all sizes and shapes containing upto two GLS lamps per fitting, complete with all accessories including connection etc. as required. |
| 40 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 41 | Installation, testing and commissioning of ceiling fan on down rod or wall fan on the existing ceiling /surface, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required. |
| 42 | Installation of exhaust fan with shutters/louversin the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 43 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) |
| 44 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 45 | 6 way (4 + 18), Double door |
| 46 | Supplying and fixing following way, Vertical type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 47 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 48 | Single pole & Neutral |
| 49 | Triple pole & Neutral |
| 50 | Supplying and fixing following rating, four pole, neutral), 415 volts, Module case circuit Breaker (MCCB),having breaking capasity of 16KAin the existingMCCB DB / Panel Board complete with connections, testing and commissioningetc. as required. |
| 51 | Supplying the following Size PVC/ XLPE insulated PVC seathed Alluminium unaromour cable of 1.1 kV as per IS 1554 etc as reqd. |
| 52 | d- 3.5 core 50 sq.mm -Common Panel |
| 53 | e- 3.5 core 70 sq.mm -ACPanel |
| 54 | Laying and fixing of one number .following size cabledirect in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. ISI mark Aluminum/copper conductor, XLPE insulated cable, FRLS PVC, galvanized steel flat strip armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - I) with latest amendments & complete all as required |
| 55 | Laying and fixing of one number of following size of cable on wall surface as required, ISI mark Aluminum/copper conductor, XLPE insulated cable, FRLS PVC, galvanized steel flat strip armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - I) with latest amendments & complete all as required |
| 56 | Supplying and making end termination with brass compression gland and aluminium lugs/copper for following size of PVC insulated and PVC sheathed / XLPE aluminium/copper conductor cable of 1.1 KV grade as required. |
| 57 | a-3 1/2 core 50 sq.mm |
| 58 | a-3 1/2 core 70 sq.mm |
| 59 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 60 | Supplying and laying 25 mm x 5 mm G.I earth strip ISI marked at 0.5 meter below grond level as stripearth electrode including soldering etc. as required |
| 61 | Supplying of of PVCExhaust fan 250 mm diasuitable to work on 230/250 volts, 50HZ complete with mounting Frame and louvers including making the hole to suit the size of above fan, making good the damage, connections, with 1.5 sq.mm PVC insulated, copper conductor, single core cable etc as per EIC of approved make including with all,., materials & labour..(Make,Halonix-DX or Equiv.-Usha-Crisp Air/Havells/Bajaj) |
| 62 | Supplyingof 1200 mm energy efficient BLDC ceiling fan with Remote control as per EIC of approved make including with all,., materials & labour. .(Make Halonix-Plasma or Equiv.-RR/Havells/CG/Usha) |
| 63 | Supply, Installation, Testing, and commissioning of 400mm sweep energy efficient Wall mounted fancomplete with 1.5 sq.mm PVC insulated, copper conductor,single core cable etc as required as per EIC.(Make Halonix-Helion Plus or Equiv.-RR/Havells/CG/Usha) |
| 64 | Supplyingof Surface or wall mounting 1 x 20W LEDtube light fitting including 1 no. of20watt LED luminairs as per EIC of approved make including with all,., materials & labour.(Make-Wipro, Cat-No-LL20-221-XXX-65NE3/ Philips /CG/ / HAVELLS) |
| 65 | Supplyingofrecess mounted round White LEDdownlighter with pressure die cast aluminium housing & PMMA diffuser suitable for 12W LEDfitting includded luminairs of approved make complete with all materials & labour.(Make-Wipro, Cat-No-LD90-141-XXX-30-XX/ Philips /CG/ / HAVELLS) |
| 66 | Supply, Installation,Testing & commissioning of indoor Flexible Warm White LED strip Light of 15W/Spoolwith Driver for cove lighting including all other materials as required(Make :Wipro,Cat No.-LS06-015-120-WW-50+LG40-078/Equiv.-CG/Philips/Havells) |
| 67 | Supplying of Hi Wall type split air-conditioning units suitable for operation on 230±10% volt, 50 Hz, 1 phase power supply, with air-cooled evaporator with coil, fan, and fan motor, air-cooled condenser with hermetically sealed rotary / scroll compressor |
| 68 | 2 TR ( Invereter - 3*) |
| 69 | Testing,Commissioning of Hi-Wall Unit |
| 70 | Supplay, Installation, Testing& Commissioning of the Copper refrigerant pipes with 13mm/9mm with nitrile rubber tube insulation & control cable for Hi-wall Unit |
| 71 | Supply, Installation, Testing and CommissioningofPVC drain pipe with 9mm thick nytrile tube insulation.(With necessary Lbow, Sockets & Reducers.) |
| 72 | Supply, Installation, Testing and Commissioningof Flexible drain pipe |
| 73 | Provision for erection (fitting & fixing) of MS structuralplatform for air-conditioning work carefully including cost, conveyance, loading and unloading of all materials and cost of all labour, sundries, T&P required for the work etc. complete in all respect as directed by the Engineer in charge. |