| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete and all as specified and removingfrom site. |
| 2 | Material and labour for point wiring surface type with two single core 1.5 Sq mm (nominal area) FRLSHPVC insulated unsheathed multi-stranded copper conductor cable in and including suitable size PVC casing capping with all fittings and fixing accessories and suitable size PVC box for mounting switches, regulator etc includingmulti-stranded PVC insulated unsheathed copper cable as earth continuity conductor of size 1.5 Sq mm and connecting to light fitting/fans etc completeall as specified and directed for following : -(colour code to be followed). (a) One light /fan point controlled by one switch |
| 3 | Supply and fixing switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body complete all as specified and directed. |
| 4 | S & F in repair ceiling rose, 3 phase/PVC/polycarbonate, isolated body surface Bakelite 65mm dia three terminals all as specified and directed. |
| 5 | Supply & fix in repair sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 8 way with IP-43 protection double door complete with appropriate size bus bar and neutral link all as specified and directed. |
| 6 | Supply and fixing in repair MCB SPN 40 to 63 Amp rating 240V, 10KA \"C\" curve and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 7 | Supply and fixing in repair MCB SP 1 to 32 Amp rating 240V, 10KA \"C\" curve and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 8 | Supply and fixing in replacement LED Street Light 24/25 watts made up of pressure die cast aluminium housing with Polycarbonate cover and unique road optics for better uniformity. The luminaire shall have minimum system lumen of 2880Lm and shall be with higher ingress protection IP66 and impact resistance of IK07. Operating voltage range: 140-270V/50Hz, Average life L70B50@50000 hours. Lumen efficacy of LED >120Lm/W, CRI≥70, CCT-5700K, & SDCM<5. Powered by built-in potted LED driver gives constant light over wide voltage range. Shall have High Voltage cut-off@325V & safety from 440V (P2P) for 8 hours. Surge protection 4 KV, Power factor ≥0.95, THD ≤10,fixed to pole or wall of building with and including suitableBracket made out of25 mm dia GIlightgrade pipe, 1.00 m long bent to shape by cutting & weldingas required & directed and fixed withtwo Nos of FI clamps 35x6 mm to be tightened with suitable size of bolts, nut and washers and including painted withtwo coat of aluminium paint over a coat of red oxide primer, and including connecting the fittingto electric sourcewith & including twin twisted copper flexible wire of size 0.75 sqmm three core with suitable size flexible PVC conduitincluding all accessories and fixing arrangements for fixing the light fitting and writing the date of fixing on security light with permt marker complete all as specified and directed. Note:-The period of defects liability shall be 02 Years from the date of installation of security light. |
| 9 | Supply & fixing in repair of bulk head fitting made from POLYCARBONATE, IP-65, IK 08, SURGE 4KV Protection cover suitable for bulk head fitting integrated type 10 watts LED, 6500K, including inbuilt electronic driver complete and connecting the same to electric source with & using PVC sheathed and insulated three core copper conductor cable of size 0.50 Sqmm and fixing arrangements for fixing the light fitting complete all as specified & directed. |
| 10 | S&F LED 9/10 watts bollard Mushroom shape with robust IP 65 rating design, Height-0.80m and efficient light distribution including light fitting fixing and making PCC block foundation of size 250x250x250mm with concrete cement and connecting the fittings on PCC foundation block with suitable size of fastner complete all as specified and directed. Note:-The period of defects liability shall be 02 Years from the date of installation of security light. |
| 11 | Supply and fix in repair post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver, lamp including grouting of GI pipe medium grade not less than 50mm and provide & fix suitable size of anti monkey cage in square shape made of 4mm GI wire of suitable size for protection of post top lantern from monkey complete all as specified and directed. Note:-The period of defects liability shall be 02 Years from the date of installation of security light. |
| 12 | Supply & Fixing and connecting Eco Set Occu Switch movement detector with a build−in switch, switch off the lights in a room or area when it is vacated, single target is to achieve incremental energy saving in a simple, reliable and affordable way, control an office area up to 28m2, 2−in−1 mounting method which can support both surfaced and recessed mounting optimized for both surface and recessed ceiling mounting and for mounting heights between 2.5 and 4 meter. The Occu switch sensor switches the lights on automatically when presence is detected and switches the lights off after the area is vacated (after 2/5/15/30 minutes depending on the settings).The smart timer will extend the delay time by the set delay time (2/5/15/30mins) if movement is detected shortly after switch−off, as suming that the area is still in use, but very little movement is made. It is possible to prevent the automatic switch−on when sufficient daylight is available in order to create additional savings. Storage conditions Temperature: -25 to +85Deg C, Operating conditions Temperature: -20 to +50Deg C, Relative humidity: 0 to 95%; no condensation, Mains connection Voltage: 100-277VAC; 50/60Hz, Mains surge immunity: 4KV, Power consumption Stand-by: <1.5W, Maximum load: 4 A (Resistive load), Load peak inrush current: 80A, Protection Class: IP20, Lifetime: 50,000hrs, Detection range for 3m mounting height @25Deg C : 6m diameter in conical shape, Signify Cat. no: SES LCM1061 Occ PIR WH or equivalent in Havells/Crompton |
| 13 | M&L for Circuit/Sub main wiring with two single core FRLSH 2.5 sqmm copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall, floor (Min 250mm depth) or ceiling for sub main connection including FRLSH 2.5 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to cdommon earth and connection to earth dolly and making good disturbed surfaces of walls, floors, etc complete all as specified.Note:- Two single core FRLSH 2.5 sqmm copper conductor, one run PVC conduit and one run of FRLSH 2.5 sqmm earth wire shall be considered & measured as one unit. |
| 14 | Supply and lay XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 Sqmm 2 Core, Complete all as specified and directed |
| 15 | Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed. |
| 16 | Returning filling in including spreading levelling watering and well ramming in layers nexc 25cm as in soil complete all as specified and directed. |
| 17 | Removing excavated material nexc 50m and depositing where directed at a level nexc 1.5m above the starting point with soil complete all as specified and directed. |
| 18 | M&L for drilling suitable dia horizontal bore holes for insertion/ laying of 32 mm to 50 mm bore HDPE pipe of any description below/under existing road surfaces / floors at a level not less than 0.60 metre etc with using mechanical / or manual devices as required at site including making good the disturbed surfaces to match with the existing after laying pipes complete all as specified and directed. Note : (i) Cost of equipmenttools and plant material (horizontal boring rig machine) required for boring shall be arranged by contractor at no extra cost to the Govt. |
| 19 | Supply and lay HDPE pipe double wall medium class, ISI Marked corrugated as in cable protection pipe of outer dia 32 mm including all fittings complete all as specified and directed. |
| 20 | Supply and lay GI tube medium grade 25mm size as in cable protection pipe including all fittings complete all as specified and directed. |
| 21 | Taking down ceiling fan/exhaust fan /air circulating fan/wall fan of any size or of any make from any locations (OTM/Md Accn) under GE (East) Agraby disconnection eletric connection, cleaning the fan box area, bringing to AGE E/M Yard and refixing at the desired location after reassembling and removing of burnt out windings (copper/aluminium), servicing/ overhauling by thouroghly cleaning the shaft,rotor,stator and applying lubricant/ grease to bearings and one coat of super enamelled varnish over winding to improve the insulation resistance including repair /replacement of spare parts/ material/items,making connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.50 Sqmm upto 0.50 Mtr length including using minor sparte/parts such as screws, insulation tape, split pins etc after cleaning the metal surface, greasing/lubricant etc to make it functional complete all as specified and as directed. Note:- (i)PVC copper flexible wire 1.50 Sqmm three core, nut bolts, washers, screws, capacitor clamp, warnishing included in the quoted rate.(ii)Other connected items required like re-winding, painting, capacitors, Bearings, Bush, Canopy,down rods, hanging clamps, nut & Bolts etc will be measured and paid sperately under respective items.(iii)Total service time from taking down to rehanging must not exceed 03 Days . (iv) Cost ofT&P & transportation including taking down and re-fixingare included in the quoted rate |
| 22 | M & L for re-winding of ceiling fan 1200mm/1400mm sweep which of copper windingwith proper grade/guage super enamelled copper winding wire so as to achieve original specifications i.e current rating and RPM (RPM test of ceiling fan with suitable tachometer will be done by contractor and shown to deptt , tachometer will be provided by contractor at their own expense) and all insulating materials (spares will be used and measure in respective items) and reasembling etc complete all as specified and directed. Notes for Sr No 22 to 26 ::- (i) The fans should be re-winded either of existingcopper/ aluminium wounded.Schedule of credit deducted as per the burnt out winding (copper/aluminium).(ii)Before winding of fans winding to be cut in front of Engr-in-Charge.(iii) Under defect liability period, in case winding or any accessory i.e capacitor, regulator becomes non functional, it will be repaired without any extra cost within 05 days of complaints received.) |
| 23 | Description all as per item No 22 here-in-before but for exhaust fans of size 200 mm sweep to 380 mm sweep. |
| 24 | Description all as per item No 22 here-in-before but for exhaust fan of size 450 mm sweep |
| 25 | Description all as per item No 22 here-in-before but for Air circulator fan of any size |
| 26 | Description all as per item No 22 here-in-before but for wall fan of any size |
| 27 | M & L for replacement of defective ball bearing for ceiling fans/exhaust fans/Air-circulators of any size and of any make complete all as directed. |
| 28 | M & L for replacement of defective capacitor of size 2.5 mfd ISI marked for any type of fans suitable for 250V/230V including making connection complete all as specified and directed. |
| 29 | M & L for replacement of ceiling fan regulator with new five step electronic (Socket /Switch type) AC 230/240 Volts suitable for any sweep complete including all fixing accessories including necessary electric connection complete all as specified and directed. |
| 30 | M & L for spray painting of ceiling fans/exhaust fans/air circulators of any size, any type and any make motor, body, blade and frame with one coat of synthetic enamelpaint by spray painting to achieve smooth and uniform finish incl removal of existing paint, filling up cavities with filler and writing of MES No with black paint complete all as specified and directed.(Note :- Painting of fans must be done before delivery of fan by contractor to Deptt on the same day.) |
| 31 | Supply and fix against BER fans, Intelligent BLDC (Brush Less Direct Current) Energy Saving Ceiling fan (copper winding) of size 1200mm sweep with smart remote for easy operation with 5 speed setting and smart features like boost mode and timer functionality for 2, 4,6 and 8 hours, 230 Volts, 50Hz, power consumption is less than 28 watt,5 Star rated, noiseless motor operation, inverter stabilization technology, 350 RPM, 230 CMM alongwith necessary accessories like anti suicide down road 12\", canopy, blades, BLDC motor, hanging clip etc and 03 year On Site warranty includingwriting the MES Number with synthetic enamel paint,including electrically connecting from fan to ceiling rose including suitable size flexible PVC conduit, complete all as specified and as directed. |
| 32 | S & F against BER exhaust fan, single phase, heavy duty, 300 mm sweep, 900 RPM including fixing of mounting frame including louver shutter on outer surface of the wall and connecting with and including three core copper conductor of 1.5 Sqmm cross sectional area of required length from ceiling rose to exhaust fan including suitable size flexible PVC conduit, complete all as specified and directed. Note : Quoted rate is deemed to be included round hole cutting in the wall and making good the surface to match with the existing surfaces. |
| 33 | S & F against BER exhaust fan, single phase, heavy duty, 450 mm sweep, 1450 RPM including fixing of mounting frame including louver shutter on outer surface of the wall and connecting with and including three core copper conductor of 1.5 Sqmm cross sectional area of required length from ceiling rose to exhaust fan including suitable size flexible PVC conduit complete all as specified and directed.Note : Quoted rate is deemed to be included round hole cutting in the wall and making good the surface to match with the existing surfaces. |
| 34 | S & F against BER PVC body Exhaust fan, 300 mm sweep, AC, RPM 1200, copper windings, single phase complete with all accessories and electric connection including making necessary holes in walls including taking down old unserviceable exhaust fan from its existing position and removing to MES store yard complete all as specified and directed.Note : Quoted rate is deemed to be included round hole cutting in the wall and making good the surface to match with the existing surfaces. |
| 35 | Supply and fixing in replacement against BER Geyser of 25 Ltrs capacity, 5 star rating AC single phase, 230 volts, Stainless Steel inner tank including connection withthree core multi stranded copper conductor of size 2.5 Sqmm including necessary fixing arrangement i.e. anchor nut, bolt, washer, CP pipe connection, grouting and making good to disturbed surface and cleaning of the area, complete all as specified and as directed. |
| 36 | Supply & Fixing in repair down rod 30 cm long, 15mm bore made out of Galvanised iron, with complete provision for hanging ceiling fan including cutting of pipe at both ends and making suitable holes forinserting fixing bolts split pins/cotter pins including suitable check nuts and necessary clamps socket with insulating rubber bush and all as specified and as directed. |
| 37 | Supply & Fixing in repair down rod 60 cm long, 15mm bore made out of Galvanised iron, with complete provision for hanging ceiling fan including cutting of pipe at both ends and making suitable holes forinserting fixing bolts split pins/cotter pins including suitable check nuts and necessary clamps socket with insulating rubber bush and all as specified and as directed |
| 38 | Supply and fix in repair GI nut bolt suitable for hanging clamp with split pins as per sample etc complete as specified and directed |
| 39 | Supply and fixing in repair of Heavy duty hanging clamp suitable for 1200/1400 mm sweep complete as specified and directed |
| 40 | Supply and fixing in repair PVC canopy including screws washer etc complete as specified and directed |
| 41 | S & F Fan blade made of aluminium suitable for 1200/1400mm sweep ceiling fans(Set of 03 Nos) including framecomplete as specified and directed |
| 42 | S & F Fan blade made of aluminium/Cast Iron suitable for 300 to 380mm mm sweep exhaust fans including framecomplete as specified and directed |
| 43 | S & F Fan blade made of aluminium/Cast Iron suitable for 450mm mm sweep exhaust fans including frame complete as specified and directed |
| 44 | S & F in repairs stationary louvers suitable for exhaust fan of 300mm to 450 mm sweep made out of powder coated aluminium anodised sheet of Min 1mm thick with non removable blades fixed permanently at 45 degree angle for protection from rain including aluminium wire mesh of suitable size for bird control Complete all as per the existing specification and as directed. (Note: Louver has to fixed upto 20 metre height multistoried building. The unit quoted rate shall deemed to be inclusive of necessary scaffolding and safety measure for fixing of louver upto thirty metre height. No extra claim on this account shall be entertained later on) |
| 45 | S & F Wall mounting fan, electric driven single phase 230 volts, oscillating type, 400 mm sweep, high quality ABS base with high speed motor and balanced blades with three leafed and 3 core copper cable of suitable size complete all as per specified. |