| 1 | Building |
| 2 | 2.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavatedearth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds ofsoil |
| 3 | 13.1.112 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 4 | 13.43.1Applying one coat of water thinnable cement primer of approved brand and manufacture on wallsurface:Water thinnable cement primer |
| 5 | 13.52.1Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as permanufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete.Onsteel work |
| 6 | 13.60.1Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Twoor more coats on new work |
| 7 | 13.61.1Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two ormore coats on new work |
| 8 | 13.65.1Painting with black anti- corrosive bitumastic paint of approved brand and manufacture to give an evenshade:Two or more coats on new work |
| 9 | 4.1.3Providing and laying in position cement concrete of specified grade excluding the cost of centering andshuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) |
| 10 | 4.1.8Providing and laying in position cement concrete of specified grade excluding the cost of centering andshuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40nominal size) |
| 11 | 5.9.1Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases ofcolumns, etc for mass concrete |
| 12 | 5.33.1Providing and laying in position machine batched and machine mixed design mix M-25 grade cementconcrete for reinforced cement concrete work, using cement content as per approved design mix,including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishingand reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate,retard setting of concrete, improve workability without impairing strength and durability as per direction ofEngineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or lesscement used as per design mix is payable or recoverable separately.All work upto plinth level |
| 13 | 15.2.1Demolishing cement concrete manually / by mechanical means including disposal of material within 50metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) |
| 14 | 15.3Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposalof unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. |
| 15 | 15.7.4Demolishing brick work manually / by mechanical means including stacking of serviceable material anddisposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.Incement mortar |
| 16 | 15.23.1Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metreslead.For thickness of tiles 10 mm to 25 mm |
| 17 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position andbinding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 18 | 11.41.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours andshades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the jointswith white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 19 | 17.2.1Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seatand lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting andmaking good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seatand lid |
| 20 | 17.7.3Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass wasteof standard pattern, including painting of fittings and brackets, cutting and making good the wallswherever require:White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brasspillar taps |
| 21 | 17.23Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of430x260x350 mm or 340x410x265 mm sizes respectively. |
| 22 | 17.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) completewith 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 23 | 17.34.1Providing and fixing toilet paper holder:C.P. brass |
| 24 | 50.12.4.1Providing and fixing false ceiling with 7.5 mm thick PVC plain panel board ceiling of approved quality inaluminium frame work with necessary screws etc complete (aluminium frame work shall be paidseparately) |
| 25 | 50.17.1.4Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. |
| 26 | 21.5Providing and fixing powder coated aluminium work ( minimum thickness of powder coating 50 micron)consisting of tee /angle sections, of approved make conforming to IS : 733 in frames of false ceilingincluding aluminium angle cleats with necessary C.P brass/ stainless steel sunk screws, aluminiumperimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing theframe work to G.I level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws allcomplete as per approved architectural drawings and direction of the Engineer-in-Charge ( level adjustinghangers, ceiling cleats and expansion hold fasteners to be paid for separately ). |
| 27 | 10.16.1Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., includingcutting, hoisting, fixing position and applying a priming coat of approved steel primer, including weldingand bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 28 | 10.25.2Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, includingcutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structuralsteel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 29 | 10.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc.,including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting thesame with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessaryaccessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of thefloor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (forpayment purpose only weight of stainless steel members shall be considered excluding fixingaccessories such as nuts, bolts, fasteners etc.) |
| 30 | 50.18.8.2.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete asper direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the walletc. 20 mm pipe 10 Kgf/ cm2 |
| 31 | 50.18.8.3.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete asper direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the walletc. 25 mm pipe 10kgf /cm2 |
| 32 | 50.18.8.4.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete asper direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the walletc. 32 mm pipe 10Kgf/cm2 |
| 33 | 50.18.8.6.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete asper direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the walletc. 50 mm pipe 10 kgf/cm2 |
| 34 | 50.18.8.7.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes with one step PVC solvent cement and testing of joints complete as perdirection of Engineer-in-Charge. Concealed work including cutting chases and making good the wall etc.63 mm pipe 6 Kgf/cm2 |
| 35 | 50.18.8.8.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes with one step PVC solvent cement and testing of joints complete as perdirection of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.75 mm pipe 6 Kgf/cm2 |
| 36 | 50.18.8.9.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes with one step PVC solvent cement and testing of joints complete as perdirection of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc.110 mm pipe 6kgf/cm2 |
| 37 | 50.18.9.9.1Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching,refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 |
| 38 | 50.18.9.10.1Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 |
| 39 | 2.25Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers notexceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 mand lift up to 1.5 m. |
| 40 | 16.83Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal ofrubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be madeseparately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 41 | 8.31Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specifiedby the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black ofany size as approved by Engineerin-Charge,in skirting, risers of steps and dados, over 12 mm thick bedof cementmortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm,including pointing in white cement mixed with pigment of matchingshade complete. |
| 42 | 18.49.1Providing and fixing C.P brass bib cock of approved quality conforming to IS: 8931.15 mm nominal bore |
| 43 | 18.53.1Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved qualityconforming to IS: 893115 mm nominal bore |
| 44 | 50.18.9.20.1Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 63 mm dia Elbow |
| 45 | 50.18.9.20.2Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement -63 dia 45 degree Elbow |
| 46 | 50.18.9.20.3Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 63 mm dia Door Elbow |
| 47 | 50.18.9.20.4Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 63 mm dia Bend |
| 48 | 50.18.9.20.5Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVCsolvent cement - 63x63x63 mm dia Tee |
| 49 | 50.18.9.20.6Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement -63x63x63 mm dia Door Tee |
| 50 | 50.18.9.20.7Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 63 mm dia vent cowl |
| 51 | 50.18.9.20.8Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 63 mm dia End cap |
| 52 | 50.18.9.21Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 75 mm dia Elbow |
| 53 | 50.18.9.21.2Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVCsolvent cement -75 mm dia 45 degree Elbow |
| 54 | 50.18.9.21.3Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVCsolvent cement -75 mm dia Door Elbow |
| 55 | 50.18.9.21.4Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 75 mm dia Bend |
| 56 | 50.18.9.21.5Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement -75x75x75 mm dia Tee |
| 57 | 50.18.9.21.6Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 75x75x75 mm dia Door Tee |
| 58 | 50.18.9.21.7Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 75 mm dia Vent cowl |
| 59 | 50.18.9.21.8Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement -75 mm dia End cap |
| 60 | 50.18.9.21.9Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 75 mm dia Socket /coupling |
| 61 | 50.18.9.21.10Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement -75x63 mm dia Reducer |
| 62 | 50.18.9.22.1Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 110 mm dia Elbow |
| 63 | 50.18.9.22.2Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 110 mm dia 45 degree Elbow |
| 64 | 50.18.9.22.3Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement-110 mm dia Door Elbow |
| 65 | 50.18.9.22.4Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement- 110 mm dia Bend |
| 66 | 50.18.9.22.5Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVCsolvent cement 110x110x110 mm dia Tee |
| 67 | 50.18.9.22.12Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 110x75 mm dia Reducer |
| 68 | od155725/2024_2025OD Derived :Providing , fixing , testing and commissioning pvc single inlet/ multy inlet(110x75x50x50x50)floor trap of self cleansing design with or without vent arm complete, including cost of masonry orconcrete supports cutting and making good the walls and floors where ever required
|
| 69 | od155726/2024_2025Providing, fixing, testing and commissioning at site 100x100 mm square C.P.cast brass or stainless steelGRATING COVER with protection from cockroaches of matching size of multi inlet or \"P\" trap complete inall respects.
|
| 70 | od155727/2024_2025Supplying approved make PVC gully trap of size 160 x 110mm and CI grating 150mmx150mm size andlight duty C.I cover with frames 300mmx300mm size(inside) the weight of cover to be not less than4.5kgand frame to be not less than2.7kg (CI MH cover and frame as per IS:1726) single sealed of sizeconveying to size the above mentioned items and constructing 30cmx30cm internal size gully trapchamber and depth upto 60cm,115 thk brick wall in CM 1:6 on a foundation of PCC 1:4:8.100mm thickplastering inside with CM 1:3,12mm thk with a neat cement flushing coat and conveying to site,cleaning,installing and testing approved make PVC gully trap with 160mm outlet(Fabricated),surrounding with CC1:1.5:3, 150x150mmm,top with CI grating above the PVC gulley trap and light duty CI cover and frameover the chamber including cost of all materials, etc complete as per approved drawing and as directedby Engineer-in- Charge. |
| 71 | 11.26.1Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurrymixed with pigment to match the shade of the slab, including rubbing and polishing complete with base ofcement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick |
| 72 | 11.27Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thickcement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment tomatch the shade of the slabs, including rubbing and polishing complete. |
| 73 | 21.12.2Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0mm thick & 2100 mm long withS.S. screws etc. complete as per direction of Engineer -in-Charge.Powder coated minimum thickness 50micron aluminium tubular handle bar |
| 74 | 9.56.3Providing and fixing ISI marked, IS : 1341, M.S. heavy weight butt hinges with necessary screws etc.complete:75x60x3.10 mm |
| 75 | 9.63.2Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screwsetc. complete:200x10 mm |
| 76 | 9.65.2Providing and fixing ISI marked oxidised M S door latches conforming to IS : 5930 with screwsetc.250x20x6 mm |
| 77 | 9.66.1Providing and fixing ISI marked oxidised M.S. handles conforming to IS : 4992 with necessary screwsetc. complete:125 mm |
| 78 | od155729/2024_2025Supplying and fixing of DUST BIN. External bin made of FRP material moulded with 3mm with Granitefinish, Inner liner of FRP material to facilitate removal of garbage, Top lid made of FRP with 3mm thick.Chain to tie top cover with body of garbage bin. Approximately 3 feet or nearby height. |
| 79 | Roads |
| 80 | 4.1.A.2Construction of granular sub-base by providing graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401Grading-II - Plant Mix Method |
| 81 | 4.12 Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. |
| 82 | 55.22 Supplying and laying interlocking tile 100 mm or nearest size thickness, minimum strength M 40 including providing a layer of 6 mm aggregate for 5 cm thickness, then laying interlock cobbles in lines and levels as per the directions of the departmental officers at site inclusive of all cost & conveyance charges etc.; complete. |
| 83 | od101172/2024_2025 Assembling, joining and laying of reinforcing elements. of synthetic geogrids for Reinforced Earth Structures |
| 84 | Electrical Work |
| 85 | 1.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulatedcopper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copperconductor single core cable etc as required.Group C |
| 86 | 1.14.1Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulatedcopper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5sq.mm + 1x1.5 sq.mm earth wire |
| 87 | 1.14.2Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulatedcopper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5sq. mm + 1 X 2.5 sq. mm earth wire |
| 88 | 1.14.3Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulatedcopper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4sq. mm + 1 X 4 sq. mm earth wire |
| 89 | 1.21.2Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm |
| 90 | 1.24.1Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.5/6 amps switch |
| 91 | 1.24.4Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 92 | 1.33Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincludingconnection etc as required. |
| 93 | 1.55.3Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( withoutindependent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable insurface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable etc. as required.Group C |
| 94 | od153965/2024_2025Supply and Installation of outdoor weather proof IP66 rated Junction Box including associatedaccessories of approved make |
| 95 | od154241/2024_2025Supply, Installation, Testing and Commissioning of 250mm sweep Light Duty Exhaust fan in plastic bodywith self opening louvers working on 230V single phase A/C. |
| 96 | 90.3.23.5.4Surface mounting decorative fluorescent tube light fitting complete with lamp with complete accessoriesduly wired up for use on 230 V AC .Surface mounting LED 40W LED Batten with out put 4000 lumen foruse on 250V AC supply |
| 97 | od153967/2024_2025Providing and fixing extra conduit down rod for ceiling fan of 20 mm dia, up to 1 meter length, wiring with2 X 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable including painting etc. asrequired. |
| 98 | od153968/2024_2025Supply & fixing of 9 W LED bulb including angle batten holder with advanced international interlockconfiguration of approved make |
| 99 | 90.4.5.2Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes usingstandard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVCinsulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extendedoriginal wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod ,canopies, shackles and blades working on 230V/240V single phase A/C |
| 100 | 2.4.6Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distributionboard, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, dinbar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator)8 way (4+24), Double door |
| 101 | 2.5.1Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCBdistribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinnedcopper bus bar, common neutral link, earth bar, din bar for mounting MCB\"s (butwithout MCB\"s andincomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets arerequired.)4 way (4 + 12), Double door |
| 102 | 2.7.6Supplying and fixing following way prewired SP&N MCB distribution board of steel sheet for 240 volts onsurface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits,duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copperbus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/ RCCB/Isolator)2+12 way, Double door |
| 103 | 2.10.1Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breakersuitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.Single pole |
| 104 | 2.10.2Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breakersuitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.Single pole and netural |
| 105 | 2.10.4Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breakersuitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.Triple pole |
| 106 | 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB completewith connections, testing and commissioning etc. as required.40 amps |
| 107 | 2.13.1Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete withconnections, testing and commissioning etc. as required.40 amps |
| 108 | 2.13.2Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete withconnections, testing and commissioning etc. as required.63 amps |
| 109 | 2.15.1Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual currentcircuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete withconnections, testing and commissioning etc. as required.25 amps |
| 110 | 2.15.2Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual currentcircuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete withconnections, testing and commissioning etc. as required.40 amps |
| 111 | 14.15.1Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket,bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in theexisting trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal) |
| 112 | 90.12.5.40Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe asrequired.4 core 10 sq mm |
| 113 | 90.12.5.41Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe asrequired.4 core 16 sq mm |
| 114 | 9.1.32Supplying and making end termination with brass compression gland and aluminium lugs for followingsize of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade asrequired.4 X 10 sq. mm (25mm) |
| 115 | 9.1.33Supplying and making end termination with brass compression gland and aluminium lugs for followingsize of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade asrequired.4 X 16 sq. mm (28mm) |
| 116 | 5.7Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earthelectrode,including connection/ termination with GI thimble etc. as required. |
| 117 | 90.15.2.3Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/twosections of hot dip galvanised GI sheet 100mm top diameter, 360mm bottom diameter thickness 3mmmm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension systemwith steel wire rope 5mm dia double drum winching system w and including round arm galvanizedluminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box andlighting spikes with single phase operation power tool installed inside the base compartment includingconnector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 12Meters |
| 118 | 90.15.4.9Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factorgreater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-castPowder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98,RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatlyaccessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be producedmentioning chip manufacturer) |
| 119 | 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and givingconnection as required3.15 mm copper conductor ( 10 SWG) |
| 120 | od154153/2024_2025Supply, Installation, Testing and Comissioning of Nickel coated Copper bonded electrode made from lowcarbon steel. Earth rods and molecularly bonded with 99.9 % pure electrolytic copper with 250 microncoating, 17.2 mm dia with pressed contact including stainless steel nut, bolts and washers.Copperbonded rod of size (17.2mm x 2000mm) with 1 nos chemical bag of 25 kg. with all accessories.Approximate weight of copper electrode is 5.62 kg. The earth rod should be properly covered with UVresistant earth pit Chamber of top 300mm, bottom 400mm and height 280mm complied to IEC62561-5:2018 including boring of earth pit suitable for the earthing to be done as per the dimension of earth rodand it should be capable of holding 25kg electrafill compound. |
| 121 | od155730/2024_2025Supplying and laying of Three layer OD 160mm HDPE Power duct along with all accessories like 1 no ofcoupler included for every 12 mtr length,2 no of end plug included for every 12 mtr length confirming to IS14930, part II complete with fittings and cutting, jointing etc. direct in ground (120 cm below ground level)including excavation,laying of pipe and refilling the trench including labour and material- 160mmdia |