Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 02-11-2024 | Corrrigendum | Technical Bid | 12-11-2024 |
| 2 | 28-10-2024 | Addenum to TCN | Technical Bid | 12-11-2024 |
| Sl. No. | Item Description |
| 1 | Earth work excavation of foundation in hard soil within initial lead of 50m and initial lift of 1.5m including dressing the sides, leveling the bed and depositing the excavated materials away from the work site, shoring etc if required, complete the item of work in all respect as per direction of the Engineer-in-charge. |
| 2 | Filling foundation and plinth with filling sand laying in layers including ramming, watering, compacting including cost, conveyance and royalty of sand from approved quarry and other taxes if any with all leads, lifts, T&P etc complete the items of work in all respect as per specification and direction of Engineer in charge. |
| 3 | CC (1:3:6) using 40 mm size and down graded crusher broken HG stone metal free from weathered surface of approved quality from approved quarry in foundation and plinth including laying concrete in layers with due compaction, watering and curing including cost, conveyance, royalty and taxes of all materials with all lead, lifts and delifts, T&P etc required for completion of the work in all respect as per direction of the Engineer-in-charge. |
| 4 | CC (1:2:4) using 12 mm size and down graded crusher broken HG stone chips free from weathered surface of approved quality from approved quarry in foundation and plinth including laying concrete in layers with due compaction, watering and curing including cost, conveyance, royalty and taxes of all materials with all lead, lifts and delifts, T&P etc required for completion of the work in all respect as per direction of the Engineer-in-charge.Ground Floor |
| 5 | Brick work with Flyash bricks of size 23 cm X 11 cm X 8 cm having crushing strength between 100 kg/cm2 to 149 kg/cm2 in cement mortar (1:6) in foundation & plinth including cost, conveyance, royalty, taxes of all materials, labour, T&P required for the work complete and as per the direction of the Engineer-in-charge. |
| 6 | Brick work with Flyash bricks of size 23 cm X 11 cm X 8 cm having crushing strength between 100 Kg/cm2 to 149 kg/cm2 in cement mortar (1:6) in superstructure including cost, conveyance, royalty, taxes of all materials, labour, T&P required for the work complete and as per the direction of the Engineer-in-charge.Ground Floor |
| 7 | First Floor |
| 8 | Second Floor |
| 9 | RCC work of M-20 grade with 20 mm and down grade black hard granite chips including cost, conveyance, royalty and all taxes of all materials with all leads, lifts, T&P etc. including rigid and smooth centering, shuttering and dismantling the same after the curing of RCC work for 28 days complete the item of work in all respect as per specification and direction of Engineer-in-charge.Column base & Footing |
| 10 | Plinth Bend |
| 11 | Column & BeamGround Floor |
| 12 | First Floor |
| 13 | Second Floor |
| 14 | Lintel Bend Ground Floor |
| 15 | First Floor |
| 16 | Second Floor |
| 17 | Chhaja and loftGround Floor |
| 18 | First Floor |
| 19 | Second Floor |
| 20 | Roof SlabGround Floor |
| 21 | First Floor |
| 22 | Second Floor |
| 23 | Staircase excluding landing but including railing.Ground Floor |
| 24 | First Floor |
| 25 | Providing MS reinforcement barsincluding cutting, bending and welding if required and tying the grills, laying and placing in proper position as per design including cost, conveyance, taxes etc of tested MS/TS rod with testing data of required specification & cost of binding wires of 18 to 20 gauge, labour, T&P required for the work complete and as per the specification and direction of the Engineer-in-charge.Ground Floor |
| 26 | First Floor |
| 27 | Second Floor |
| 28 | Supplying of M.S Doors, Window with grills, Grills,Collapsible gates made out of M.S Angle frame, M.s Flat Sheet etc. of approved section and design, electrically welded properly with all necessary locking arrangement and one coat redoxide primer including cost of all materials, labour, T&P, carriage of materials to site etc. complete as per the direction of the Engineer-in-charge.Ground Floor / First Floor / Second FloorCollapsible Gate / Window Grill |
| 29 | Labour for fitting and fixing of MS doors and windows, MS grill gate as per approved design including cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge.Ground Floor / First Floor / Second FloorCollapsible Gate / Window Grill |
| 30 | Supplying and fixing ISI marked 35mm thick flush door shutters confirming to IS : 2202 (Part-I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of approved design including cost of all door fittings and fixtures etc. complete as per the direction of the Engineer-in-charge.Ground Floor / First Floor / Second Floor |
| 31 | Supplying, fitting and fixing of window (sliding type) made up Aluminium section 9778 as window frame, section no. 4095,4096 and 9777,3994 as shutter frame with 5mm thick glasss as panel fitted with rubber beading including locking arrangement including all fitting including cost of all material, taxes labour T&P including cost ofglass etc. complete as per direction of Engineer-in-charge.Ground Floor / First Floor / Second Floor |
| 32 | Providing, fitting and fixing of Al. door with anodized Al. door section 9202 as vertical member, 9201 as top, 9200 as bottom and middle member with frame section as 9221 with tapered clip no. 4660 and the frame to be completed by means of jointing angle No. 1885with 6mm thick toughened glasss as panel fitted with rubber beading including locking arrangement, all cost of material,labour T&P, all taxes, hire charges of drilling machine etc. complete as per direction of Engineer-in-charge.Ground Floor / First Floor / Second Floor |
| 33 | Providing and fixing of WPC Door Frames with Rebate cuts and Finished cross section size 75mm x 45mm or 90mm x 50mm including cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, scaffolding, staging, watering and curing, T&P etc. complete as per the direction of the Engineer-in-charge.Ground Floor / First Floor / Second Floor |
| 34 | Providing and fixing of 30mm thick WPC door shutter with hinges, tower bolt, handle, stainless steel screws etc. including the cost of all materials, hardware fittings, cost of all labour, conveyance, taxes, loading, unloading, T&P etc. complete as per the direction of Engineer-in-charge. Ground Floor / First Floor / Second Floor |
| 35 | 12mm thick cement plaster (1:6) in cement mortar finished smooth surface on brick wall after racking out joints including watering curing to required period including cost conveyance, royalty of all materials, T&P complete etc. as per specification and direction of Engineer in charge.Ground Floor |
| 36 | First Floor |
| 37 | Second Floor |
| 38 | 16mm thick cement plaster (1:6) in cement mortar finished smooth surface on brick wall after racking out joints including watering curing to required period including cost conveyance, royalty of all materials, T&P complete etc. as per specification and direction of Engineer in charge.Ground Floor |
| 39 | First Floor |
| 40 | Second Floor |
| 41 | 6mm thick cement plaster in cement mortar (1:4)to RCC surface finishedincluding watering curing to required period including cost conveyance, royalty of all materials, T&P complete etc. as per specification and direction of Engineer in charge.Ground Floor |
| 42 | First Floor |
| 43 | Second Floor |
| 44 | 12mm thick cement plaster in cement mortar (1:4) in septic tank including cement punning with cost conveyance, royalty of all materials, T&P complete etc. as per specification and direction of Engineer in charge. |
| 45 | Supplying, fitting and fixing vitrified tiles in floors of size 600mm x 600mm of approved make confirming to IS: 13755 laid on 20mm thickcement mortar 1:4 (1 cement : 4 sand) and fillingjoined with white cement of approved qualityincluding cost, conveyance, royalty, taxes of all materials, labour, T&P required for the work complete and as per the direction of the Engineer-in-charge.Ground Floor |
| 46 | First Floor |
| 47 | Second Floor |
| 48 | Supplying, fitting and fixing vitrified tiles in dado, skirting and risers of steps on 12mm thick cement plaster (1:3) joint with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing, cost, conveyance, royalty, taxes of all materials, labour, T&P required for the work complete and as per the direction of the Engineer-in-charge.Ground Floor |
| 49 | First Floor |
| 50 | Second Floor |
| 51 | Supplying, fitting and fixing granite tiles in floors, treads on steps and landing on 25mm thick bed of cement mortar 1:1 (1 cement: 1 sand) joined with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing, cost, conveyance, royalty, taxes of all materials, labour, T&P required for the work complete and as per the direction of the Engineer-in-charge.Ground Floor |
| 52 | First Floor |
| 53 | Second Floor |
| 54 | Supplying, fitting and fixinggranitetile in dado, skirting and risers of steps on 12mm thick cement plaster (1:3) joint with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing, cost, conveyance, royalty, taxes of all materials, labour, T&P required for the work complete and as per the direction of the Engineer-in-charge.Ground Floor |
| 55 | First Floor |
| 56 | Supplying, fitting and fixingceramic floor tiles in floors, treads on steps and landing on 25mm thick bed of cement mortar 1:1(1 cement :1 sand) joined with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing, cost, conveyance, royalty, taxes of all materials, labour, T&P required for the work complete and as per the direction of the Engineer-in-charge.Ground Floor |
| 57 | First Floor |
| 58 | Second Floor |
| 59 | Supplying, fitting and fixingceramic wall tile in dado, skirting and risers of steps on 12mm thick cement plaster (1:3) joint with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing, cost, conveyance, royalty, taxes of all materials, labour, T&P required for the work complete and as per the direction of the Engineer-in-charge.Ground Floor |
| 60 | First Floor |
| 61 | Second Floor |
| 62 | 20 mm thick grading plaster in cement mortar (1:4) over roof slab including cost, conveyance, royalty, taxes of all materials & complete workas per specification and direction of Engineer in charge.Ground Floor |
| 63 | First Floor |
| 64 | Second Floor |
| 65 | Painting two coats of synthetic enamel paint over a coat of primer of approved quality, brand and shade including smoothening the surface by sand paper and filler etc complete with cost, conveyance, royalty, taxes of all materials, labours T&P required as per specification and direction of Engineer-in-charge.Ground Floor / First Floor / Second Floor |
| 66 | Finishing suface ofwallswith cement based wall putty (Water based ) of approved make and finished smooth and even surface to receive painting with cost, conveyance, royalty taxes of all materials labour T&P and scaffolding as required for the work and as per specification and direction of Engineer-in-charge.Ground Floor |
| 67 | First Floor |
| 68 | Second Floor |
| 69 | Finishing to walls with two coats weather coatover one coat primer and weather coat paint of approved brand and approved colour including cleaning the surfacewith cost, conveyance, royalty taxes of all materials labour T&P and scaffolding as required for the work and as per specification and direction of Engineer-in-charge.Ground Floor |
| 70 | First Floor |
| 71 | Second Floor |
| 72 | Finishing to walls with two coats plastic emulsion paint over one coat primer andplastic emulsion paint of approved brand and approved colour including cleaning the surfacewith cost, conveyance, royalty taxes of all materials labour T&P and scaffolding as required for the work and as per specification and direction of Engineer-in-charge.Ground Floor |
| 73 | First Floor |
| 74 | Second Floor |
| 75 | Providing and fixing in position 50mm thick pre-cast cement concrete jally (1:2:4) hard granite chips including roughening, cleaning, fixing and finishing in cement mortar (1:3) etc. complete in all respectas per the direction of the Engineer-in-charge. |
| 76 | Supplying and fixing of 60mm thick cement concrete interlocking paver block of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect confirming toIRC SP 63:2018 as per the direction of the Engineer-in-charge. |
| 77 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mmx32mmx2mm @ 0.90m C/C and stainless square pipe bracing of size 32mmx32mmx2mm in 3 rows in staircase as per approved design and specification, buffing, polishing etc. with cost, conveyance, taxes of all materials, labour, T&P etc. required for completion of work in all respect as perdirection of Engineer-in-charge. Ground Floor / First Floor / Second Floor |
| 78 | Providing and injecting chemical emulsion for pre-construction antitermite treatment and creating a chemical barrier using Chloropyriphos Emulsifiable 1.0% concentration by weight under and all around foundation pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor,along the external perimeter of building atleast 2 meter all around the outer face of plinth area, expansion joints, surrounding of pipes, water conduits or at places as per the direction of Engineer-in-charge. |
| 79 | Supplying and fixing of Pre cast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required patternetc. complete in all respect confirming to IS 5758:1984 as per the direction of the Engineer-in-charge. |
| 80 | INTERNAL ELECTRIFICATIONRecessed wirring tolight point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH/LSZHPVC insulated copper conductor of ISI markedMake- Finolex/Anchor/Polycab/ HAVELLS/RR KABLE/KEIwith 20 mm dia PVC non metallic heavy dutyconduit FRLS type ISI markedMake-AKG/BEC/Precision/Norpack6A modular type ( flame retradant type)switch ISI marked Make-Schneider (Zencelo) /legrand( Myrius) /Panasonic (vision)/Eq. and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (flame retradant type) Make-Schneider (Zencelo) / legrand( Myrius) / Panasonic (vision)/Eq. of suitable size, modular box with 1.5 sq. Mm FRLSHPVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. Group -A |
| 81 | Group-B. |
| 82 | Group-C. |
| 83 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (anti bactorial & flame retradant type))with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge..Make-Schneider (Zencelo) / legrand( Myrius) /Panasonic (vision)/Eq. (Maximum 02 nos point in one circuit). |
| 84 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) /Eq. (Maximum 02 nos point in one circuit). |
| 85 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)( flame retradant type))with suitable size modular box & cover( falme retradant type) including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge.. Make-Schneider ( Zencelo ) / legrand ( Myrius) / Panasonic(vision)/Eq.(For equipment power). |
| 86 | Wiring for twin control light point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in recess PVC conduit with 2 way modular switch with ISI marked, modular base of suitable size ISI marked with metal box(18 SWG) and earthing point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor for loop earthing etc as required. |
| 87 | Recess wiring for circuit/submain wiring with the following mentioned size PVC FRLSH / LSZHinsulated, copper conductor, single core cable Make- Finolex / Anchor / Polycab / HAVELLS / RR KABLE / KEIinrecessed PVC conduit Heavy duty FRLS of mentioned size Make-AKG / BEC / Precision/Norpakas required as per direction of Engg.-in-Charge. a) 2 x 2.5mm2 for inverter wiring |
| 88 | b) 2 x 1.5mm2 + 1 x 1.5mm2 |
| 89 | c) 2 x 2.5mm2 + 1 x 1.5mm2 |
| 90 | d) 2 x 4mm 2 + 1 x 1.5mm2 |
| 91 | e) 4 x 6mm2 + 2 x 2.5mm2 |
| 92 | f) 4 x 10mm2 + 2 x 4 mm2 |
| 93 | MAIN PANELS/I/T&Commissioning of LT indoor floor mounted cubical typeelectrical main panelmade out by 2mm CRCA steel sheet duly derusted & painted by simens gray powder cote paint is designed asG.A drawing as per direction of Engg.-in-Charge.In commer- 01 number of 100 Amps4P MCCB,25KA with 100A 4P changeover switch (Icu=100%Ics) with shunt trip.with auxuliary Busbar- 04 numbers of 100Amps Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator Out going- .(i)63A FP MCCB 16KA- 04 Nos. (ii) 63A 4P MCB-03Nos.(iii) 40A 2P MCB- 03 Nos. Instrument- (i) 06 (03 main +03 DG) numbers phase indicating lamp withHRC fuse.(ii) 01 set of digital type multifunction meter with CT for voltage, current, frequency, PF, THD indication (iii) 01 set of 40KA TYPE2+1 4P SPD along with 63A 4P MCB.Make of switchgear-Legrand / Schneider /Siemens / ABB/ Havells/ C&S/ Hagar / L&T as per the direction of the Engineer-in-charge. |
| 94 | DBs4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(but with out MCB/ RCCB/ Isolator)(FOR LIGHT,POWER INDOOR,3-PH,POWER LOAD) |
| 95 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB ofMake-LEGRAND/ Siemens/ Schneider /Equievalant model of Havells/C& S/ ABB/Hagar/L&T in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. |
| 96 | Supplying and fixing 6-32Amps DP 240 volts, MCBMake-LEGRAND/ Siemens/ Schneider /Equievalant model of Havells/C& S/ ABB/Hagar/L&T in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. |
| 97 | Supplying and fixing 40Amps 4P 415 volts MCBMake-LEGRAND/ Siemens/ Schneider /Equievalant model of Havells/C& S/ ABB/Hagar/L&Tin the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge. |
| 98 | Supplying and fixing 40Amps 4P 415 volts RCCB 30 mAMake-LEGRAND/ Siemens/ Schneider /Equievalant model of Havells/C& S/ ABB/Hagar/L&T in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. |
| 99 | Fitting & FixturesS/F. of Superior type Call bell with push & flexible cord as per direction of Engg.-in-Charge. |
| 100 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge. |
| 101 | S/F of BLDC Fan regulator.Make:Legrand / L&T / Havells / Anchor / Eq as per direction of Engg.-in-Charge. |
| 102 | S/F of 400 mm sweep wall Fan Make:Usha / Almonard / Crompton / Havells / Bajaj / Halonix as per direction of Engg.-in-Charge. |
| 103 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep(Make- Havells / Crompton / Usha / Orient / Bajaj / Halonix ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. |
| 104 | S/F. of 250mm Sweep Exhaust fans of ISI marked.(Make:-Havells Thrill Air DX / Usha / Crompton / Orient / Bajaj / Halonix/equivalent) as per direction of Engg.-in-Charge. |
| 105 | S/F. of 90Wt.With efficacy of 120lm/W Light emitting diode Street light fittings of Havells/Crompton/ Bajaj/Philips/Halonix /Panasonic/ Wipro/LT as per direction of Engg.-in-Charge. |
| 106 | S/F. of 120Wt.With efficacy of 120lm/W Light emitting diode Street light fittings of Havells/Crompton/ Bajaj/Philips/Halonix /Panasonic/ Wipro/LT |
| 107 | S/F. of 20Wt.,100lumens/watt efficacacy, aluminium battenLight emitting diode Tube light fittings of Havells/Crompton/ Bajaj/Philips/ Halonix /Panasonic/Wipro/LT as per direction of Engg.-in-Charge. |
| 108 | S/F. of 18 Wt.Surface/Recess Mounting LED Down Light of Bajaj/ Havells / Crompton/ Philips/ Panasonic/Wipro/Halonix make as per direction of Engg.-in-Charge. |
| 109 | S/F. of 15 Wt.Surface/Recess Mounting LED Down Light of Bajaj/ Havells / Crompton/ Philips/Panasonic/Wipro/Halonix make as per direction of Engg.-in-Charge. |
| 110 | S/F. of 12 Wt.Surface/Recess Mounting LED Down Light of Bajaj / Havells / Crompton / Philips / Panasonic/ Wipro / Halonix make as per direction of Engg.-in-Charge. |
| 111 | S/F of 3Modular Skirting LED light fitting.Make:Legrand / Bajaj / Havells / Crompton / Philips / Panasonic / Wipro / Halonix as per direction of Engg.-in-Charge. |
| 112 | Lightning ProtectionSupply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/Cape as per direction of Engg.-in-Charge. |
| 113 | Supply of Roof conductor holder for parapet- Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561.as per direction of engineer in charge.Make-OBO/Dehn/Cape |
| 114 | Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/Cape |
| 115 | Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561 ( 2nos / expansion piece ).Make - OBO / Dehn / Cape |
| 116 | Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305.Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO / Dehn / Cape |
| 117 | Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn/Cape |
| 118 | Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp testedupto 100KA lightning current . Make-OBO/Dehn/Cape |
| 119 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn/Cape |
| 120 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer.Tested for 100kA lightning current. Make-OBO / Dehn / Cape |
| 121 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/Cape |
| 122 | Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/Cape |
| 123 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/Cape |
| 124 | Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO / Dehn / Cape |
| 125 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/Cape |
| 126 | Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO / Dehn / Cape |
| 127 | Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn/Cape |
| 128 | Supply of Earth conductivity enhancing mineral compound shall be of 25kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO / Dehn / Cape |
| 129 | Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn/Cape |
| 130 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 131 | FIRE EXTINGUISHER Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,Carbon di-oxidetype capacity 4.5kg with all accessories (Ever safe / Fire shield / ceasefire / safex) as per direction of Engg.-in-Charge. |
| 132 | Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,ABC type capacity 6kg with all accessories(Ever safe / Fire shield / ceasefire / safex) as per direction of Engg.-in-Charge. |
| 133 | CABLESProviding,fixing and laying of 50 mm dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching (75 mm depth) and refilling as per direction of Engg.-in-Charge. |
| 134 | Supply of 35 sq.mm 3 & 1/2 core XLPE Al.Armoured Cable of ISI marked.(Make -Polycab / Havells / KEI / RR Kable / Finolex / Gloster) as per direction of Engg.-in-Charge. |
| 135 | Layingand fixing of one number of PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation, sand cushing, protective covering and refilling the trench etc. as required as per direction of Engg.-in-Charge. |
| 136 | Layingand fixing of one number of PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding25 sq.mm but not exceeding 120 sq.mm on surface as required as per direction of Engg.-in-Charge. |
| 137 | Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.(3.5C x 35 sq.mm) as per direction of Engg.-in-Charge. |
| 138 | S/F of special earthing complete with 3mtr long 40 m dia G.I pipe , 600x600x3.15mm thick copper plate , charcoal , salt including excavation of earth and filling of loose soil upto ground level including all connection and masonary work as per direction of Engg.-in-Charge. |
| 139 | Supplying and laying 25 mm x 5 mm CU earth strip ISI marked on surface or in recess for connection etc as required.as per direction of Engg.-in-Charge. |
| 140 | Supply and installation of Rubber Mats 8 mm thick as per direction of Engg.-in-Charge. |
| 141 | WATER SUPPLY AND SANITARYProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes confirming to IS 15778 having thermal stability for hot & cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints etc. complete as per specification and direction of the Engineer-in-charge.20mm ( 3/4\" dia ) |
| 142 | 25mm (1\" dia ) |
| 143 | 32mm ( 1 1/4\" dia ) |
| 144 | 50mm (2\" dia ) |
| 145 | Supplying all labour, T&P and fixing of 15mm dia CP bib cock/ Taper cock/ Long body bib cock polished bright of the following nominal sizes as per specification complete and as per the direction of the Engineer-in-charge.15mm CP bib cock ( Long Body ) |
| 146 | 15mm CP bib cock ( Short Body ) |
| 147 | Supplying all labour, T&P for fixing of brass or GM Ball valve of the followingnominal size with wheel as per specification etc. complete as per the direction of Engineer-in-charge..25mm (1\" dia ) Ball valve |
| 148 | 32mm ( 1 1/4\" dia ) Ball Valve |
| 149 | 50mm (2\" dia ) |
| 150 | Supplying all materials, labour, T&P and fiixng 500 mm x 440mm size Orissa Pan with cement concrete (1:4:8) using hard granite metal all complete as per specification and direction of the Engineer-in-charge. |
| 151 | Supplying all materials, labour, T&P and fiixng European type WC (Commode - white) with integral \"S\" trap to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement morter(1:1) etc all complete as per specification and direction of the Engineer-in-charge. |
| 152 | 1500 Ltr. Capacity water storage tank |
| 153 | Supplying all materials, labour, T&P and construction of stage for installation of PVC water storage tank of different size as per PH design and specification including cost of all materials, labour charges, T&P, royalty, taxes etc. all complete as per the direction of the Engineer-in-charge. |
| 154 | Supplying all materials, labour, T&P for fiixng wash hand basin (500 x400mm) for pillar taps with cast iron or MS brakets painted white including cutting holes in walls and making good the damages etc. all complete as per specification and direction of the Engineer-in-charge. |
| 155 | Supplying all materials, labour, T&P and fiixng S/S Kitchen Sink with cast iron or MS brackets painted white including cutting holes in walls and making good the same etc. all complete as per specification including cost of all materials, labour charges, T&P, royalty, taxes etc. all complete as per the direction of the Engineer-in-charge. |
| 156 | Supplying all materials, labour, T&P for construction of M.H Chamber of size 1.20mx 0.90mx 0.90m deep with 100 mm thick precast RCC slab in C.C (1:1.5:3), 100 mm thick sand filling in foundation, 150 mm thick cement concrete (1:3:6) using 25 mm size HGCB metal in foundation, KB brick masonary in CM (1:4) using 23 cm size KB bricks, in side plaster 12 mm thick in CM (1:4), CC (1:2:4) with neat cement punning for benching and channeling including earth work in excavation, earth filling with excavated earth to out side cavity of chamber etc.complete. |
| 157 | Supplying all materials, labour, T&P for construction of M.H Chamber of size 0.75mx 0.75mx 0.60m deep with 100 mm thick precast RCC slab in C.C (1:1.5:3), 100 mm thick sand filling in foundation, 150 mm thick cement concrete (1:3:6) using 25 mm size HGCB metal in foundation, KB brick masonary in CM (1:4) using 23 cm size KB bricks, in side plaster 12 mm thick in CM (1:4), CC (1:2:4) with neat cement punning for benching and channeling including earth work in excavation, earth filling with excavated earth to out side cavity of chamber etc.complete. |
| 158 | Providing and fixing in position RCC Main hole cover including cost of all materials, labour charges complete as per the direction of the Engineer-in-charge. |
| 159 | Providing and fixing in position RCC Main hole steps including cost of all materials, labour charges complete as per the direction of the Engineer-in-charge. |
| 160 | Fixing of 100mm dia CP round grating in floor as per specification and direction of the Engineer-in-charge. |
| 161 | Fixing CP brass soap dish complete with chromium plated brass brakets fixed towooden plugs with chromium plated brass screws etc. all complete as per the direction of the Engineer-in-charge. |
| 162 | Fixing standard size chromium plated brass towel rail complete with chromium plated brass brakets fixed to wooden plugs with chromium plated brass screws complete as per specification . |
| 163 | Fixing standard size chromium plated brass towel ring complete with chromium plated brass brakets fixed to wooden plugs with chromium plated brass screws complete as per specification . |
| 164 | Fixing of rectangular plastic framed mirror of superior glass and fixed to wooden plugs with chromium plated brass screws and washers complete as per specification complete and diection of the Engineer-in-charge. |
| 165 | Cutting holes through the brick or laterite masonry wall for taking Sand Cast Iron (SCI) /centrifugally cast (spun) iron pipes and mending good the damages as per the direction of the Engineer-in-charge. ( 250mm to 375mm thick wall ) |
| 166 | Cutting of R.C.C roof or carnice for taking S.C.I or centrifugally cast (spun) iron pipes and mending good the damages etc all complete as per the direction of the Engineer-in-charge. |
| 167 | Supplying all materials, labour and T&P for cutting groves in pucca floor and walls for taking G.I. pipes and fittings / P.V.C. pipes and fittings and making good to the damages with cement concrete (1:2:4) with 12mm size HG chips and finished smooth with cement mortar (1:3) to original shape including cost , conveyance of materials, labours, curing etc. all complete as per specification and direction of the Engineer-in-charge. |
| 168 | Fixing PVC Nahani traps of the following nominal diameter of out let of self cleaning design with sand cast iron screwed down or hinged grating with or with out vent arm complete including cost of cutting and making good the walls and floors as per specification. |
| 169 | Fixing 160mm dia PVC SWR pipes & fittings to wall with nail, bobbins and woden plug as per specification or laying in trenches including earth work in excavation in all kinds of soil, embeded pipe with cc (1:2:4) and refilling of trenches as per specification in ground floor ( jointing to be measured and paid separately) including cost of pipe and fitting as per the direction of Engineer-in-charge.. |
| 170 | Supplying all materials, labours, T&P & fitting & fixing U-PVC SWR soil waste ventilating pipes & fittings of the following outside diameter confirming to IS: 4985/2000 to wall with nail, bobbins and woden plug or laying in trenches including jointing with supply of approved rubber lubricant by non heat appplication method as per manufacturer\"s specification, testing etc. complete as per specification and direction of the Engineer-in-charge. (Eath work in excavation in all kinds of soil and refilling of trenchesto be measured and paid separately) 110mm dia PVC SWR Pipe |
| 171 | 110mm dia PVC SWR\"P\" trap |
| 172 | 110mm dia PVC SWR Plain Bend |
| 173 | 110mm dia PVC SWR Door Bend |
| 174 | 110 x 110 x 110mm dia PVCSWR Tee |
| 175 | 110mm dia PVC SWR S/J with door (Door Tee) |
| 176 | 110mm dia PVC SWR Cowl |
| 177 | 110mm PVC SWR Clamp |
| 178 | 110mm PVC SWR Coupler |
| 179 | 75mm dia PVC SWR Pipe |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail