tender for Provision Of Extra 11Kv Underground 400Mtr Substation To Double Due To Damage Of Existing Industrial Consumers Create New Industral Feeder For Byfercation Of 11Kv Chitehara Industrial From Luharli Substation Only D P Sub Staion Under 11 Kv Outgoing, Construction of 03 no. 11 KV line under 33/11 KV sub-station Chitahara and Kudikheda in the area of power distribution division Dadri and work related to bifurcation., 1 Provision of Extra 11KV Underground 400Mtr Substation to Double due to Damage of Existing Industrial Consumer 2 Safe carriage of following stock material, from any of the Store Center of PVVNL to work siteincluding Loading from Store and safe unloading at site for Item No. 3 to 10 3 ST Pole 11Mtr 4 STONE PAD 5 TOP CHANNEL 6 DROPPER CHANNEL 7 11KV XLPE CABLE 3X185sqmm 8 11KV O/D Termination Kit for 3x185sqmm XLPE Cable 9 11KV STRAIGH THROUGH for 3X185sqmm XLPE Cable 10 11KV PIN INSUTLATOR WITH PIN 11 Errection of above Following material and Supply and errection of the D.Centralised material for completing the works as per RESPO. 12 The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, E bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule.Double Pole Structures(a)ST 11MTR LONG 13 Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming.Single Pole and Double Pole(a)ST 11MTR LONG 14 FIXING OF PIN INSULATOR WITH PIN, COMPLETE WORK IN ALL RESPECT. 15 FIXING OF TOP CHANNEL AS PER SITE REQUIREMENT. 16 FIXING OF DROPPER CHANNEL AS PER SITE REQUIREMENT. 17 FIXING OF STONE PAD AS PER SITE REQUIREMENT. 18 Laying and commissiong of 11KV 3x185sqmm XLPE CableDouble Ckt. after digging trenchof dia 220 mm in two parallel bores for Double Curcuit by manual method at a depth of 1.50 mtrs to 2.50 mtrs. (as requirement at site) below the ground levelfor laying cable and refilling of trench including connections at both ends after providing and crimping of lugs of proper size for completion of work and Providing & Laying of Ist Class Bricks, along the length on both side of 11KV XLPE Cable in Cable Trench (minium 18No. Bricks/Mtr per Cable) and Stone Slab of size 450x600x50mm on top of the each Cable, Providing 150 thickness mm River sand for cushion beneath and 150mm above the cable and Back filling of excavated earth in the cable trench upto the ground level and ramming properly. 19 Digging of pits of size 4 mtr x 4 mtr x 1.5 mtr for cable loop and making risers at double pole and re-filling of pits in proper manner with required material at kacha/pakka and hot mix road. (All Work and materialin the scope of contractor) 20 Laying of 11 KV 3X185 Sq.mm XLPE Cable in the air on cable Riser Double Pole, existing trench cable trench, nala x-ing & G.I.Pipe and making connection complete at both ends. 21 Preparation and Fixing of 11 KV Power Cable ends:Making and Fixing of 11 KV XLPE Heat shrinkable outdoor jointing kits suitable for 3x185sqmm XLPE Cable after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs with complete connention in all respect. 22 Preparation and Fixing of 11 KV Power Cable ends:Making and Fixing of 11 KV XLPE Heat shrinkable stright throughsuitable for 3x185sqmm XLPE Cable after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs with complete connention in all respect. 23 Providing and Fixing of GI Pipe 6 Dia as per site requirement. 24 Providing and Fixing of Ms Holding Clamp as per site requirement. 25 Providing and Fixing of MS Nut Bolt as per site requirement. 26 Road Cutting and Road Restoration Charges for the above work. 27 Create new industral feeder for byfercation of 11KV chitehara industrial from Luharli Substation 28 Safe carriage of following stock material, from any of the Store Center of PVVNL to work siteincluding Loading from Store and safe unloading at site for Item No. 29 to 38 29 PCC POLE 11MTR 30 STONE PAD 31 TOP CHANNEL 32 DROPPER CHANNEL 33 11KV XLPE CABLE 3X300sqmm 34 11KV O/D TERMINATION KIT FOR XLPE 3X300sqmm CABLE 35 11KV PIN INSUTLATOR WITH PIN 36 11KV VCB O/G 200/100/5AMP. 37 11KV VCB I/C 600/300/5AMP. 38 EARTHING COMPLETE 39 Errection of above Following material and Supply and errection of the D.Centralised material for completing the works as per RESPO. 40 The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, E bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule.Double Pole Structures(a)PCC POLE 11MTR 41 Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming.Single Pole and Double Pole(a)PCC POLE 11 MTR 42 FIXING OF PIN INSULATOR WITH PIN, COMPLETE WORK IN ALL RESPECT. 43 FIXING OF TOP CHANNEL AS PER SITE REQUIREMENT. 44 FIXING OF DROPPER CHANNEL AS PER SITE REQUIREMENT. 45 FIXING OF STONE PAD AS PER SITE REQUIREMENT. 46 INSTALLATION AND COMMISSIONING OF 11KV VCB O/G 200/100/5AMP. WITH COMPLETE CONNECTIONS AND WORK IN ALL RESPECT. 47 INSTALLATION AND COMMISSIONING OF 11KV VCB 1/G 600/300/5AMP. WITH COMPLETE CONNECTIONS AND WORK IN ALL RESPECT. 48 Laying and commissiong of 11KV 3x300sqmm XLPE CableDouble Ckt. after digging trenchof dia 220 mm in two parallel bores for Double Curcuit by manual method at a depth of 1.50 mtrs to 2.50 mtrs. (as requirement at site) below the ground levelfor laying cable and refilling of trench including connections at both ends after providing and crimping of lugs of proper size for completion of work and Providing & Laying of Ist Class Bricks, along the length on both side of 11KV XLPE Cable in Cable Trench (minium 18No. Bricks/Mtr per Cable) and Stone Slab of size 450x600x50mm on top of the each Cable, Providing 150 thickness mm River sand for cushion beneath and 150mm above the cable and Back filling of excavated earth in the cable trench upto the ground level and ramming properly. 49 Digging of pits of size 4 mtr x 4 mtr x 1.5 mtr for cable loop and making risers at double pole and re-filling of pits in proper manner with required material at kacha/pakka and hot mix road. (All Work and materialin the scope of contractor) 50 Laying of 11 KV 3X185 Sq.mm XLPE Cable in the air on cable Riser Double Pole, existing trench cable trench, nala x-ing & G.I.Pipe and making connection complete at both ends. 51 Preparation and Fixing of 11 KV Power Cable ends:Making and Fixing of 11 KV XLPE Heat shrinkable outdoor jointing kits suitable for 3x300sqmm XLPE Cable after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs with complete connention in all respect. 52 Driving of MSearth rod of size20x2500 mm in earth andjointing through G.I. wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts for pole earthing. Supply Erection, fixing, grouting of stay rod in cement, sand and brick ballastin ration 1:4:8 in Block 600*600*300 mm with binding & nuzzlingincluding providing & fixing of stay insulator complete in all respect with grouting. (All Work and Material in the scope of Contractor) 53 PROVIDING AND FIXING OF HOLDING CLAMP AS PER REQUIREMENT. 54 PROVIDING AND FIXING OF NUT & BOLTS AS PER REQUIREMENT. 55 Providing and Fixing of GI Pipe 6 Dia as per site requirement. 56 Road Cutting and Road Restoration Charges for the above work. 57 New Line Construction of 11KV Line Poposed Vill- Kachera To DujanaUNDER EDD DADRI 58 Safe carriage of following stock material, from any of the Store Center of PVVNL to work siteincluding Loading from Store and safe unloading at site for Item No. 59 to 74 59 PCC POLE 8.5 Mtr 60 ST Pole 11Mtr 61 PCC POLE 9Mtr 62 STONE PAD 63 DOG CONDUCTOR 64 11KV T CHANNEL 65 MS TOP CHANNEL 66 MS DROPPER CHANNEL 67 11KV DISC WITH FITTINGS 68 11KV PIN INSULATOR WITH PIN 69 EARTHING COMPLETE 70 STAY SET WITH CONCRETING 71 11KV CROSS ARM 72 11KV XLPECABLE 3X185sqmm 73 11KV O/D Termination Kit for XLPE3x185sqmm Cable 74 11KV I/D Termination Kit for XLPE3x185sqmm Cable 75 Errection of above Following material and Supply and errection of the D.Centralised material for completing the works as per RESPO. 76 The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, E bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule.Double Pole Structures(a)ST 11MTR LONG 77 The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, F bracket 75x10mm, G.I.Nut bolt & washer, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required.Single Pole(a) PCC - 8.5 Mtr. Long Pole, PCC - 9mtr Long 78 Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming.Single Pole and Double Pole(a)ST 11MTR LONG, PCC - 8.5 Mtr. Long Pole, PCC - 9mtr Long 79 FIXING OF PIN INSULATOR WITH PIN, COMPLETE WORK IN ALL RESPECT. 80 FIXING OF TOP CHANNEL AS PER SITE REQUIREMENT. 81 FIXING OF DROPPER CHANNEL AS PER SITE REQUIREMENT. 82 FIXING OF STONE PAD AS PER SITE REQUIREMENT. 83 FIXING OF DISC INSULATOR WITH FITTING, COMPLETE WORK IN ALL RESPECT. 84 FIXING OF T CHANNEL AS PER SITE REQUIREMENT. 85 FIXING OF CROSS ARM AS PER SITE REQUIREMENT. 86 FIXING OF STONE PAD AS PER SITE REQUIREMENT. 87 Preparation and Fixing of 11 KV Power Cable ends:Making and Fixing of 11 KV XLPE Heat shrinkable outdoor jointing kits suitable for 3x185sqmm XLPE Cable after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs with complete connention in all respect. 88 Preparation and Fixing of 11 KV Power Cable ends:Making and Fixing of 11 KV XLPE Heat shrinkable INDOOR jointing kits suitable for 3x185sqmm XLPE Cable after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs with complete connention in all respect. 89 Laying, Strainging, Re-Laying and commissiong of overhead 11KV 3x185sqmm XLPE Cablewith complete connections in all respect. 90 Laying, spreading, lifting and final sagging of 3 OR 4phases Dog conductor in accordance with Line chart includidng binding and fixing of all accessories in 03Nos OR 04 Nos. Conductor in parallel as per site requirement. 91 Driving of MSearth rod of size20x2500 mm in earth andjointing through G.I. wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts for pole earthing. Supply Erection, fixing, grouting of stay rod in cement, sand and brick ballastin ration 1:4:8 in Block 600*600*300 mm with binding & nuzzlingincluding providing & fixing of stay insulator complete in all respect with grouting. (All Work and Material in the scope of Contractor) 92 Fixing, tightening & nozzling of stay set with wire and stay rod with the poles of required tension as per drawing, including providing & fixing of Stay Insulators of 11KV and Stay Clamps and Grouting of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:3:6 cement, sand, 20mm Stone grift) as per drg. Including back filling of soil and proper ramming etc. 93 Providing and Fixing of F Bracket as per site requirement. 94 Providing and Fixing of Danger Board as per site requirement. 95 Providing and Fixing of Ms Holding Clamp as per site requirement. 96 Providing and Fixing of MS Nut Bolt as per site requirement.