| 1 | EXCAVATION & EARTHWORK |
| 2 | Excavation in trenchesnot exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed |
| 3 | Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed |
| 4 | Removing excavated materialsto a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed |
| 5 | B/R WORKS |
| 6 | Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and removal of debris complete all as specified and as directed |
| 7 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for and removal of debris complete all as specified and as directed |
| 8 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and disposing off complete all as specified and as directed |
| 9 | Demolition of reed, lathing, single or double including battens and plaster or chiken wire lathing complete all as specified and as directed |
| 10 | Dismantling plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding, etc. complete all as specified and as directed |
| 11 | Dismantling of timber scantling 40sqcm and over in section, in any position in unframed works complete all as specified and as directed |
| 12 | Dismantling wall and ceilingboards (fibre, pulb, insulation, etc.) or insulation boards slabs/blankets of any thickness including cover fillets complete all as specified and as directed |
| 13 | Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles and disposing off complete all as specified and as directed |
| 14 | Taking down cement or cement/lime plaster,any description on brick or stone walls, etc. including raking out joints, hacking for keys, scubbing down with water, etc. including all necessary scaffolding as required and rubbishing off the premises, etc. complete all as specified and as directed |
| 15 | Taking down chowkats or frames not exceeding 1.5sqm each with shutters (without taking off shutters from the frame), disposing off and making good the disturbed areas, portions and surfaces |
| 16 | Taking down chowkats or frames exceeding 1.5sqm but not exceeding 4.0sqm each with shutters (without taking off shutters from the frame), disposing off and making good the disturbed areas, portions and surfaces |
| 17 | S&F in position steel work in trusses, purlins, posts and the like using tubular/ square hollow sections including special shaped washer, etc. using ERW or induction butt welded tubes / SHS conforming to IS-1161-2014 / IS-4923-1997 grade St-240 complete all as specified and as directed |
| 18 | S&F bands, straps, hold fasts, wall ties, two way and three way straps, plate washers and similar articles of mild steel 25x5mm conforming to Fe-290 grade E-165 complete all as specified and as directed |
| 19 | S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar works conforming to Fe-290 grade E-165 complete all as specified and as directed |
| 20 | S&F rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing conforming to Fe 410W grade-E -250, quality \"A\" complete all as specified and as directed |
| 21 | S&F screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed at both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5cm in length, dia of neck & shank 11 to 15mm complete all as specified and as directed |
| 22 | S&F plates (plain or chequered) channels, square cut or notched (ordinay and counter sunk) forming holes, without any attachment of Fe 410W grade-E -250, quality \"B\" complete all as specified and as directed |
| 23 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed |
| 24 | M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders securing with clips complete all as specified and as directed |
| 25 | M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 200mm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 50mm but n exceeding 100mm wide complete all as specified and as directed |
| 26 | M&L for brickwork with sub-class \"B\" bricks, straight or curved on plan to any radius as in half brick thick walls built in CM (1:4) complete all as specified and as directed |
| 27 | M&L for providing RCC (nominal mix) 1:1.5:3 type A1 using 20mm graded aggregates as in beams, cantilevers, lintels, etc. over 1.5m long complete all as specified and as directed |
| 28 | M&L for 75mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregates) as in floors, plinth protection, pavings, etc. surface finished even and fair, laid in alternate bays/panels and joints filled with bituminous mix of 1 part bitumen and 3 part of sand complete all as specified and as directed |
| 29 | M&L for cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregates) as in bed blocks, back filling of steel frame and holdfasts, etc. including necessary formwork complete all as specified and as directed |
| 30 | M&L for complete removal and preparation of old decorated surfaces of walls by brooming down or steel wire brushing, scrapping down smoke shoots, moulds, moss and efforescent salts, trading oil, greasy spots, etc. including all necessary staging, scaffolding, etc. as required to work at heights, etc. complete all as specified and as directed |
| 31 | M&L for preparation of masonry / concrete wall surfaces and applying1mm thick wall care putty rubbed with sand paper for making surface smooth and even including all necessary staging, scaffolding, etc. as required to work at heights, etc. complete all as specified and as directed |
| 32 | M&L for preparation of masonry / concrete wall surfaces and applying1mm thick weather proof wall care putty rubbed with sand paper for making surface smooth and even including all necessary staging, scaffolding, etc. as required to work at heights, etc. complete all as specified and as directed |
| 33 | M&L rendering 15mm thick, in cement mortar (1:4) on walls / concretesurfaces, etc. in two layers (10+5mm) finishing layer mixed with integral water proofing compound @3% by weight of cement, finished even and smooth without using extra cement complete all as specified and as directedNote: WPC will be measured and paid separately under respective item herein |
| 34 | M&L rendering 15mm thick, in cement mortar (1:4) on walls / concretesurfaces, etc. finished even and fair without using extra cement complete all as specified and as directed |
| 35 | Supply only integral water proofing compound all as specified |
| 36 | M&L for forming construction joint 30mm deep x 10mm wide filled with sealing compound grade \"A\" complete all as specified and as directed |
| 37 | S&F in repairs 4mm dia GI wire fixed to both ends of wall by means of fastening bolts or T shaped nuts & bolts complete all as specified and as directed |
| 38 | S&F factory made solid PVC gauged door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width, stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2020) complete all as specified and as directed |
| 39 | S&F factory made solid PVC panelled door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width, stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2020) complete all as specified and as directed |
| 40 | S&F 3 way sliding anodised aluminium glazed window shutter with frame with the following specifications complete all as specified and as directed.(a) Frame 50x65x1.5mm thick(b) 35x35x1.5mm Z section in stiles, rails(c) 50x35x1.5mm T section mullion(d) PVC gasket and with 4.8mm thick coloured glass pane one side mirror finished, area not exceeding 0.5sqm each with aluminium handles and necessary locking arangements(e) Stainless steel wire mesh for mosquito proofing arrangement all as directed |
| 41 | S&F 2 way sliding anodized aluminium glazed ventilator shutter with frame consists of following specification complete all as specified and as directed(a) Ventilator frame 2 track of size 60x25x1.5mm thick(b) Stiles and rails of size 35x25x1.5mm(c) 35x35x1.5mm T section mullion(d) PVC gasket with 4mm thick tinted glass, including aluminium handles with necessary locking arrangement |
| 42 | Notes for item Nos. 40 & 41: (a) Area of opening shall only be considered for meaurement purposes (b) All necessary accessories including tinted glass, PLPB, fittings, fixtures for assembling / fixing as per drawing complete shall be included in the quoted rate |
| 43 | S&F 100mm long stainless steel butt hinges of selected quality complete all as specified and as directed |
| 44 | S&F 150mm extruded aluminum alloy handles, cast type, anodized complete all as specified and as directed |
| 45 | S&F 200mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and as directed |
| 46 | S&F in repairs 300mm aluminium anodised sliding door bolt with hasp and staple, bolt type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed |
| 47 | S&F in repairs 140mm anodized aluminium alloy body and tongue, with hard drawn steel spring with vulcanized rubber piece complete all as specified and as directed |
| 48 | S&F in repairs 20mm dia fancy type chromium coated (tint as approved) MS curtain / drapery rods, etc. of rod wall thickness 1mm (min), including pair of CP MS brackets, holders with funnel at ends complete all as specified and as directed |
| 49 | S&F false ceiling with fully perforated 12mm thick micro tegular edge of 10mm thick square at all heights with glass reinforced gypsum ceiling tiles of size 595x595mm, if approved texture, pattern and design having moisture content less than 2%, humidity resistance 99%, NCR (0.75 to 1) as per IS-8225:1987 (updated till date), nn-combustible as per BS: 475 (Part-IV) 1970 (updated till date), reflectance minimum 85% when laid truely horizontal level, suspended from interlocking \"T\" grid of hot dipped galvanized (galvanized @120gm/sqm) iron section 0.33mm thick, network comprising of main T runner of size 32x15mm 3000mm long, cross T of size 32x15mm 1200mm long, secondary intermediate cross T of size 32x15mm 600mm long, forming grid size of 600x600mm duly suspended from soffits of slab with galvanized (galvanized @80gm/sqm) iron wire 8mm outer dia, 50mm long, alongwith 6mm dia fully threaded hanger rods upto 1000mm length, L shaped adjusters of size 85x25mm GI perimeter angle of size 24x24x0.4mm 3000mm long, fixed with anchor fastners @450mm c/c and 40mm long dry wall screws complete all as per drawings, as specified and as directed |
| 50 | M&L for preparation of new masonry / concrete wall surfaces and applying two coats of acrylic distemper (tint as approved) over and including one coat of alkali resistant walll primer with all necessary staging, scaffolding, etc. as required complete all as specified and as directed |
| 51 | M&L for preparing of new steel / metal surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed |
| 52 | M&L for preparation of new plastered surfaces and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali & fungus resistant, dirt resistant, exterior paint (of approved tint, company depot tinted) with silicon additives @1.43litre/10sqm over a priming coat of exterior primer applied @0.90litre/10sqm complete all as specified and as directed |
| 53 | M&L for non-skid ceramic tiles, coloured, area of tile exceeding 0.18sqm but not exceeding 0.36sqm each, 7 to 8mm thick of superior quality as in floors, etc. laid over 15mm thick screed bed in CM (1:6) (rate shall be included) set and jointed in neat cement slurry @3.00kg of cement per sqm and pointed in white cement mixed with colouring pigment to match shade of tiles complete all as specified and as directed |
| 54 | S&F pre-painted galvalume aluminum zinc coating GI based semi corrugated steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed |
| 55 | S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed |
| 56 | E/M WORKS |
| 57 | Taking down copper / aluminium point wiring (light, fan, socket or power) including fixture and fittings viz. switches, ceiling roses, light fittings, pendants, regulators, sockets, etc. and disposing off complete all as specified and as directed |
| 58 | M&L for point wiring with 1.5sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade, IS-694 marked, with multi-stranded copper conductor, drawn through and including non-metallic heavy duty PVC conduit not less than 20mm dia and accessories concealed in walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly complete all as specified and as directed for the following: |
| 59 | One light point controlled by one 5A one way switch |
| 60 | One ceiling fan / exhaust fan point controlled by one 5A one way switch |
| 61 | One switch socket outlet 3 pin 5A controlled by one switch on independent board |
| 62 | One switch socket outlet 3 pin 5A controlled by one switch on same board |
| 63 | M&L for point wiring with 2.5sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade, IS-694 marked, with multi-stranded copper conductor, drawn through and including non-metallic heavy duty PVC conduit not less than 20mm dia and accessories concealed in walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly for 3 pin 15A switch socket independent outlet complete all as specified and as directed |
| 64 | S&F ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals complete all as specified and as directed |
| 65 | S&F switch piano flush button type, single pole, ISI marked, one way 5A, 230V complete all as specified and as directed |
| 66 | S&F switch socket combination outlet, 2 in 1, 5 & 15A flush type, ISI marked, 230V complete all as specified and as directed |
| 67 | S&F switch socket combination outlet, 5 in 1, 6 pin, 5 & 15A flush type, ISI marked, 240V complete all as specified and as directed |
| 68 | S&F switch socket outlet, 5 pin, 5A flush type, universal, ISI marked, 230V complete all as specified and as directed |
| 69 | S&F PVC / polycarbonate lamp holder, insulated body, bracket holder / angle holder with back plate 240V complete all as specified and as directed |
| 70 | S&F electronic fan regulator, stepped socket type (5 steps), 100W, 50Hz, 230V, ISI marked duly connected up complete all as specified and as directed |
| 71 | S&F in repairs fan hook fabricated in MS flat iron 25x6mm 300mm long, bent to shape with drilled holes to accommodate nuts suitable for hanging ceiling fans, entirely painted with two coats of synthetic enamel paint complete all as specified and as directed |
| 72 | S&F LED bulb 10W, 5 star rated, B-22 CDL and connecting to lamp holder including taking down and disposing off old bulb / lamp complete all as specified and as directedMake: Crompton, Phillips, Wipro, Surya, Havells, Bajaj |
| 73 | S&F 1x20W LED tube light fitting, 220V, 50Hz, decorative box type, with driver, holder, all accessories pre-wired including 20W LED bulb/lamp and connecting up with twin core twisted flexible copper conductor cable of suitable size and taking down and disposing off old fitting complete all as specified and as directed |
| 74 | S&F bulk head fitting LED, 10W, with pressure die cast housing, acrylic diffuser with frame and connecting accessories and connecting up including taking down old fitting and disposing off complete all as specified and as directed |
| 75 | S&F building security light, LED luminaire 30W IP 66 with LED lamp, driver, etc. with all accessories pre-wired and connecting with 3 core flexible copper conductor cable drawn through PVC conduit of size 20mm and taking down and disposing off old fitting completeall as specified and as directed |
| 76 | M&L for taking down ceiling fans 1200/1400mm sweep and carting to store,and scrapping old worn out paint from fan and blades, by rubbing with suitable emery paper, etc. and spray painting with two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer and writing MES number of fans (tint as approved and suitable sized font) in body of fan and refixing in position (old/new) after building repair works including providing new safty pins, etc. and greasing/oiling of moving parts and minor repairs complete all as specified and as directedNotes: (a) Cost of all carting (to and fro), loading, unloading, etc. cost of minor spares and pins shall be deemed to be included in the quoted rate (b) IVs and RVs shall be submitted by the Contractor to claim payment |
| 77 | S&F heavy duty, PVC body with PVC blades, legs, ISI marked energy efficient, exhaust fan, 250mm sweep, 230V, 50Hz, 1200RPM, copper wound, with louvers and connecting up including provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including grouting the nuts and bolts and taking down old / unserviceable fan from any location / position and disposing off complete all as specified and as directed |
| 78 | S&F sheet metal enclosures for 8 way MCB DB, 240V, SPN, double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces including taking down old damaged DB and disposing off complete all as specified and as directed |
| 79 | S&F sheet metal enclosures for 4 way MCB DB, 415V, TPN, double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces including taking down old damaged DB and disposing off complete all as specified and as directed |
| 80 | Taking down old unserviceable submain wiring of any type, any size, from any location or position and disposing off including making good the disturbed surfaces, etc. complete all as specified and as directed |
| 81 | M&L for submain wring using proper colour codingwith 2 runs of single core, PVC insulated,FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 4sqmm and 1 run of 4sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC conduit 20mm wide, heavy duty, ISI marked concealed in wall/ceiling/roof, etc. with all required accessories complete all as specified and as directedNotes: (i) 2 runs of 4sqmm main cable, 1 run of earth conductors and 1 run of PVC conduit shall be measured as one length(ii) Separate conduit shall be used for each sub-main wiring circuit irrespective of numbers of wire(iii) The minimum size of conduit shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of casing as per requirement at site |
| 82 | S&F in repairs MCB SP, 240V, 5 to 40A, 10kA, 50Hz, C curve complete all as specified and as directed |
| 83 | S&F in repairs MCB isolator SPN, 240V, 40A, 10kA, 50Hz, C curve complete all as specified and as directed |
| 84 | S&F in repairs MCB isolator TPN, 240V, 63A, 10kA, 50Hz, B curve complete all as specified and as directed |
| 85 | M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directedNote: Only punned thickness of sand shall be considered for measurement purposes |
| 86 | Supply and laying burnt bricks of sub-class \"B\" designation 75 laid in trenches for cable protection complete all as specified and as directed |
| 87 | S&Fsteel water tubing, light grade, 40mm bore, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for cable protection, etc. complete all as specified and as directed |
| 88 | Supply, laying, jointing, connecting and testing 3.5 core 25sqmm XLPE insulated PVC sheathed cable 1100V grade, screwed PVC bedded, armoured electric power cable, conforming to IS: 7098 (Part-I), heavy duty multi-stranded aluminium conductor laid in trenches / fixed on walls/poles, passing through pipes, etc. including connecting up to DBs, etc. with required lugs, end terminal / cable glands including taking out/down old unserviceable cable and disposing off complete all as specified and as directedNote: Excavation and earthwork will be measured and paid separately under respective item herein |
| 89 | M&L for earthing using GI earthing wire with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth lead wire 4mm dia extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 15mm light grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications, taking down and disposing off old earthing complete all as specified and as directed |
| 90 | Notes for serial item No. 89: (i) The cost of GI earth continuity wire / strip with GI pipe 20mm medium grade upto 7.5m is deemed to be included(ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item(iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge |