| 1 | Earthworkinexcavationbymechanicalmeans(Hydraulicexcavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. |
| 2 | All kinds of soil |
| 3 | Earth work in excavation by mechanicalmeans (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 4 | All kinds of soil. |
| 5 | Fillingavailableexcavatedearth (excludingrock)intrenches,plinth.sidesof foundationsetc.inlayersnotexceeding 20cmindepth,consolidatingeach deposited layer by ramming and watering, lead up to 50 m and for all lift |
| 6 | Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. |
| 7 | Supplying chemical emulsion in sealed containers including delivery as specified. |
| 8 | Chlorpyriphos emulsifiable concentrate of 20% |
| 9 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : |
| 10 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos E.C. 20% with 1% concentration |
| 11 | Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole :With Chlorpyriphos E.C. 20% with 1% concentration |
| 12 | Providingandlayinginpositioncementconcreteof specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 13 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 14 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 15 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 16 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer\"s specification. |
| 17 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 18 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 19 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 20 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 21 | Reinforcedcement concreteworkinwalls(any thickness), includingattachedpilasters,buttresses,plinthandstring courses, fllets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: |
| 22 | 1:1.5:3 (1cement :1.5 coarsesand(zone-III)derivedfrom natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 23 | Reinforced cement concrete work in beams, suspended foors, roofshavingslopeupto 15°landings,balconies,shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 24 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 25 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 26 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 27 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 28 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 29 | Weather shade, Chajjas, corbels etc., including edges |
| 30 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 31 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 32 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 33 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 34 | ProvidingandlayingAutoclavedAeratedconcreteblocks (AAC)masonry 150mm/230mm/300mmthick AACwith Grade-1blocks of density 551-650 kg/cum conforming to IS:2185 (Part 3)in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block layingpolymermodifiedadhesivemortarallcompleteasperdirectionof Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 35 | Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete. |
| 36 | 8mm thickGranite of any colour and shade |
| 37 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 38 | Fixed to openings /wooden frames with rawl plugs screws etc. |
| 39 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 40 | 300x16 mm |
| 41 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 42 | 250x10 mm |
| 43 | 150x10 mm |
| 44 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 45 | 125 mm |
| 46 | 100 mm |
| 47 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 48 | Twin rubber stopper |
| 49 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms |
| 50 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 51 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm),with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer-in-charge |
| 52 | Extruded section profile size 48x40 mm |
| 53 | Providing and fixing to existing door frames. |
| 54 | 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of \"H\" section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. \"U\" cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer\"s specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter). |
| 55 | Providing and fixing factory made uPVC glazed/ wire mesh windows/doorscomprisingofleadfreeuPVCmulti- chamberedframe,sashandmullion/coupler(wherever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (whereever required) of appropriate dimension, EPDM gasket, hardware,SS 304 grade fasteners of minimum 8 mm dia. with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as perIS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steelscrewsetc.Profileofframe,sash&mullion(if required) shall be mitred cut and fusion welded/ mechanicallyjointeddulysealedat allcorners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification &direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh/ Glazing of plain/ toughened/ laminated/ double glass unit with/ without high performance coatings as per designrequirementsandconformingtoIS: 3548&IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute,to be provided by the manufacturer for : (iii)Siteswith basic wind speed > 45 m/sec as per IS 875 - Part 3 (iv) Sites with structure height more than 20m for all wind speeds. |
| 56 | Fixed window/ ventilator with mullion/ transom.Using R3 series with frame (55mm & above) x (45mm & above)&mullion(55mm&above)x(65mm&above). (Height upto 2.5meter) |
| 57 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 58 | Steel work in built up tubular (round, square or rectangular hollow tubesetc.)trussesetc.,includingcutting,hoisting,fixingin position and applying a priming coat of approved steel primer, including welding andbolted withspecial shaped washers etc. complete. |
| 59 | Electric resistance or induction butt welded tubes |
| 60 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 61 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 62 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding pointing the joints with white cement and matching pigments etc., complete. |
| 63 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 64 | Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm |
| 65 | Providing and fixing plain multipurpose cement board(Hight pressure steamcured)withsuitablescrewsforcementparticleboardin ceiling etc. complete (frame work to be paid seperatately). |
| 66 | 6 mm thick Cement fiber board, Type-B, Category-III as per IS: 14862:2000 |
| 67 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 68 | 110 mm diameter |
| 69 | Providing and fixing onwall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 70 | Single tee with door110x110x110 mm |
| 71 | Bend 87.5°110 mm bend |
| 72 | Shoe (Plain)110 mm Shoe |
| 73 | Providingandfixingunplasticised PVCpipeclipsof approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mmhard wood plugs,screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete. |
| 74 | 110 mm |
| 75 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws cmplete: |
| 76 | Barge board (Upto 300 mm) |
| 77 | Crimp curve |
| 78 | Gutter (600 mm over all girth) |
| 79 | 12 mm cement plaster of mix : |
| 80 | 1:4 (1 cement: 4 fine sand) |
| 81 | 6 mm cement plaster of mix : |
| 82 | 1:3 (1 cement : 3 fine sand) |
| 83 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. |
| 84 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 85 | Finishing walls with Acrylic Smooth exterior paint of required shade . |
| 86 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm |
| 87 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 88 | Two coats |
| 89 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 90 | Two or more coats on new work |
| 91 | Engraving letters in hard stone |
| 92 | Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 93 | W.C. pan with ISI marked white solid plastic seat and lid |
| 94 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 95 | Rectangular shape 453x357 mm |
| 96 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall |
| 97 | 25 mm nominal dia Pipes |
| 98 | 40 mm nominal dia Pipes |
| 99 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings withonestep CPVCsolvent cementandthe cost of cutting chasesandmaking good thesame including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
| 100 | 15 mm nominal dia Pipes |
| 101 | 20 mm nominal dia Pipes |
| 102 | 25 mm nominal dia Pipes |
| 103 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work |
| 104 | 40 mm nominal dia Pipes |
| 105 | Making connection of G.I. distribution branch with G.I main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: |
| 106 | 25 to 40 mm nominal bore |
| 107 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 108 | 25 mm nominal bore |
| 109 | 40 mm nominal bore |
| 110 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 111 | 25 mm nominal bore |
| 112 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 113 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 114 | 15 mm nominal bore |
| 115 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 116 | 15mm nominal bore |
| 117 | Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in- charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). |
| 118 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 119 | 40 mm thick with 20 mm nominal size stone aggregate |
| 120 | Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multimodals location etc., laid on 20mm thick base of cement mortar 1:4(1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc.complete as per direction of Engineer-in-Charge. |
| 121 | Providing cement concrete surface drainincluding earthexcavation 10 cm thick base concrete with 1:3:6 ( 1 cement: 3 sand: 6 graded stone aggregate 40 mm nominal size) finished with 1:4 (1 cement: 4 fine sand) including a floating coat of neatcement inside the drain and its top and exposed surface including earth work in excavation and disposed of surplus earth. |
| 122 | 23 x 23 cm surface drain |
| 123 | Providing and fixing pre-painted galvalume (PPGL) steel profile sheets AZ-150 of brand Tata Bluescope steel, Everest Industries Ltd., JSW Steel Ltd., Jindal India Ltd. or equivalent (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50mm (+ 0.05%) total coated thickness with aluminium zinc coating 150 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping aluminium screws (Xylan) of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 124 | Providing and fixing pre-painted galvalume (PPGL) steel profile sheets AZ-150 of brand Tata Bluescope steel, Everest Industries Ltd., JSW Steel Ltd., Jindal India Ltd. or equivalent (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with aluminium Zinc coating 150 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 125 | Ridges plain (500 - 600mm) |
| 126 | Extra for providing and fixing wind ties of 40x6mm flat aluminium section. |
| 127 | Providing and fixing CP brass towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, as directed by Engineer-in-charge. |
| 128 | Providing and fixing CP brass towel rail complete with brackets fixed to CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 129 | 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, as directed by EIC |
| 130 | Providing and fixing soil, waste and vent pipes with UPVC pipe conforming to IS : 13592 Type Bincluding jointingof pipes & fittings with one step solvent and testing of joints complete as per direction of Engineer-in-charge. (i) Single socketed pipes |
| 131 | 110 mm dia pipe |
| 132 | 75 mm dia pipe |
| 133 | 50 mm dia pipe |
| 134 | Providing and fixing UPVC moulded door bend of required degree with access door insertion rubber washer 3 mm thick, bolts and nuts complete for UPVC soil pipes conforming to IS : 14735Type B including jointingof pipes & fittings with one step solvent and testing of joints complete as per direction of Engineer-in-charge. |
| 135 | 110 mm dia |
| 136 | 75 mm dia |
| 137 | 50 mm dia |
| 138 | Providing and fixing UPVC moulded plain bend of required degree for UPVC soil pipes conforming to IS : 14735Type B including jointingof pipes & fittings with one step solvent and testing of joints complete as per direction of Engineer-in-charge. |
| 139 | 110 mm dia |
| 140 | 75 mm dia |
| 141 | 50 mm dia |
| 142 | Providing and fixing UPVC moulded single equaljunction with door of required degree for UPVC soil pipes conforming to IS : 14735Type B including jointingof pipes & fittings with one step solvent and testing of joints complete as per direction of Engineer-in-charge. |
| 143 | 110x110x110 mm |
| 144 | Providing and fixing UPVC terminal guard |
| 145 | 110 mm dia |
| 146 | 75 mm dia |
| 147 | Providing and fixing UPVC moulded self cleaning trap design with screw down or hinged grating with arm complete including cost cutting and making good the walls and floors complete |
| 148 | 110 mm inlet and 75 mm outlet |
| 149 | Constructing masonry Chamber 30x30x50 cm inside, in cement concrete solid block size of 400x150x200mm work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominalsize),i/cnecessaryexcavation,foundationconcrete 1:5:10) 1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : |
| 150 | Providing and fixing CP brass 2 in 1bib cock with wall flange including fittings complete of approved quality. |
| 151 | 15 mm nominal dia |
| 152 | Providing and fixing CP brass Health faucet (ABS) with rubbit cleaning system, 125cm long CP flexible tube and ABS wall hook of make - Hindware/Jaquar or its equivalent with fittings complete. |
| 153 | 15mm nominal bore |
| 154 | Providing and fixing 3 mm dia. G.I. level adjusting hangers (between 600 mm upto 1200mm length), fixed/tied to roof truss complete as per direction of Engineer-in-charge. |
| 155 | Providing and fixing UV stabilised polyethylene septic tank in colour terracotta/black of capacity 10 to 15 users (Type-I) having dimension 850mm dia 2500 mm length, 10mm thick, 03 Nos chambers and 02 Nos manholes of 550mm dia, having inlet and outlet pipe of dia 110mm with air vent pipe 50mm dia, including the cost of earth work and CC bed of 1:4:8 of 10mm thick including transportation, refilling with earth etc complete as per the direction of Engineer-in-charge. |
| 156 | Constructing soak pit 1.00x1.00x1.20 m filled with stone aggregate 90mm to 45mm in size including PVC pipe 100 mm diameter and 1.20 m long complete as per standard design. |
| 157 | Providing and fixing braille encrypted stainless steel sheets of required sizes, signages and informations in walls, rails or any location as directed by Engineer-in-charge. |