| 1 | 11kV New Line on 8.5 Mtr. PCC Pole with ACSR Rabbit Conductor |
| 2 | PCC Pole, 8.5 Mtr. Long |
| 3 | Stone Pad (300x300x75mm) |
| 4 | V-Type Cross arm for 11KV Line, 65x65x6 mm, GI Angle |
| 5 | Cross arm holding Clamp with nuts & bolts |
| 6 | 11KV `F\" Bracket with N&B |
| 7 | Supply of ACSR RabbitConductor |
| 8 | Erection of ACSR RabbitConductor |
| 9 | 11kV Polymer Disc Insulator T&C type 45 KN |
| 10 | Disc Fittings T&C type 45 KN |
| 11 | 11 KV Composite Polymer Pin Insulator with Nut and washers as per TS |
| 12 | 11KV MS Danger Board with clamp, bolts & nuts |
| 13 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS |
| 14 | Stay Wire 7/10 SWG |
| 15 | PG Clamps |
| 16 | Earthing of pole by MS earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. |
| 17 | Aluminium Jointing Sleeves |
| 18 | G.I. Barbed Wire |
| 19 | GI Wire 6 SWG |
| 20 | GI Wire 8 SWG |
| 21 | GI Wire 16 SWG |
| 22 | Eye Bolt |
| 23 | Turn Buckle |
| 24 | 11kV \"E\" Bracket with N&B |
| 25 | GI Top Channel 100x50x2240 mm.With Clamp and NB and washer |
| 26 | GI Angle 65x65x6 mm, 2700 mm long bracing complete with clamps, Nut, bolt and washers |
| 27 | GI Channel 100x50x6 mm. 1300 mm long with clamp, nut,bolt and washer |
| 28 | GI Channel 100x50x6, 1525 mm long ,with clamp, nut,bolt and washer |
| 29 | Guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. |
| 30 | Concreting of Pole/Support as per TS |
| 31 | 11kV New Line on 8.5 Mtr. PCC Pole with ACSR Weasal Conductor |
| 32 | PCC Pole, 8.5 Mtr. Long |
| 33 | Stone Pad (300x300x75mm) |
| 34 | V-Type Cross arm for 11KV Line, 65x65x6 mm, GI Angle |
| 35 | Cross arm holding Clamp with nuts & bolts |
| 36 | 11KV `F\" Bracket with N&B |
| 37 | Supply of ACSR Weasal Conductor |
| 38 | Erection of ACSR weasal Conductor |
| 39 | 11kV Polymer Disc Insulator T&C type 45 KN |
| 40 | Disc Fittings T&C type 45 KN |
| 41 | 11 KV Composite Polymer Pin Insulator with Nut and washers as per TS |
| 42 | 11KV MS Danger Board with clamp, bolts & nuts |
| 43 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS |
| 44 | Stay Wire 7/10 SWG |
| 45 | PG Clamps |
| 46 | Earthing of pole by MS earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. |
| 47 | Aluminium Jointing Sleeves |
| 48 | G.I. Barbed Wire |
| 49 | GI Wire 6 SWG |
| 50 | GI Wire 8 SWG |
| 51 | GI Wire 16 SWG |
| 52 | Eye Bolt |
| 53 | Turn Buckle |
| 54 | 11kV \"E\" Bracket with N&B |
| 55 | GI Top Channel 100x50x2240 mm.With Clamp and NB and washer |
| 56 | GI Angle 65x65x6 mm, 2700 mm long bracing complete with Clamps, Nut, bolt and washers |
| 57 | GI Channel 100x50x6 mm. 1300 mm long with clamp, nut,bolt and washer |
| 58 | GI Channel 100x50x6, 1525 mm long ,with clamp, nut,bolt and washer |
| 59 | Guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. |
| 60 | Concreting of Pole/Support as per TS |
| 61 | New LT Line on ACSR Weasel Conductor on 8.5 Mtr. PCC Pole |
| 62 | PCC Pole, 8.5 Mtr. Long |
| 63 | Stone Pad (300x300x75mm) |
| 64 | LT clamp with nut and bolt for PCC pole |
| 65 | LT Shakle Insulator 100x115 mm With Nut and Bolt |
| 66 | Supply of ACSR Weasel Conductor |
| 67 | Erection of ACSR Weasel Conductor |
| 68 | Aluminium Jointing Sleeves |
| 69 | Earthing complete with M.S. Earthing Rod 20x2500 mm. & GI wire 6 SWG |
| 70 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS |
| 71 | Stay Wire 7/10 SWG |
| 72 | Concreting of Pole/Support as per TS |
| 73 | Guarding angle 75x75x6mm.1600 MM long with holding angle |
| 74 | G.I Wire 6 SWG along with span |
| 75 | G.I Wire 8 SWG |
| 76 | G.I Wire 16 SWG for winding |
| 77 | Eye Bolt |
| 78 | Construction of new 100 KVA, 11/0.433kV Distribution Transformer S/S |
| 79 | 11/0.44 kV 100 KVA Transformer (Level-I) as per specified in T.S. |
| 80 | PCC Pole, 8.5 Mtr. Long |
| 81 | Stone Pad (300x300x75mm) |
| 82 | GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers |
| 83 | GI Channel 100x50x2240mm (For TPMO,LA and Fuse set) |
| 84 | Holding Clamps for Top Channel TPMO & Fuse Set etc. with nuts, bolts & washers |
| 85 | GI Angle 75x75x6 mm, 2028 mm long with clamp for T/F base |
| 86 | 11kV Polymer Disc Insulator T&C type 45 KN |
| 87 | Disc Fittings T&C type 45 KN |
| 88 | 11 KV Composite Polymer Pin Insulator with clamp and washers as per TS |
| 89 | 11kV TPMO complete set |
| 90 | 11kV DO Fuse Set (3 Phase) |
| 91 | 11kV Lightening Arrestor (Set- 3 No) |
| 92 | G.I. Barbed Wire |
| 93 | 11kV MS Danger Board with clamp, bolts & nuts |
| 94 | SMCDistribution boxas per technical specificationsfor 3 Ph 100 KVA DTR |
| 95 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS |
| 96 | Stay Wire 7/10 SWG |
| 97 | Chemical Pipe Earthing (80 mm dia, 3 m long Pipe) as per TS |
| 98 | LT PVC Cable3.5x150/70Sq.mm. |
| 99 | ACSR Weasel Conductor |
| 100 | Earthing of pole by MS earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. |
| 101 | GI Channel 100x50x2028mm (ForDistribution box)) |
| 102 | Concreting of Pole/Support as per TS |
| 103 | Construction of new 63 KVA, 11/0.433kV Distribution Transformer S/S |
| 104 | 11/0.44 kV 63 KVA Transformer (Level-I) as per specified in T.S. |
| 105 | PCC Pole, 8.5 Mtr. Long |
| 106 | Stone Pad (300x300x75mm) |
| 107 | GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers |
| 108 | GI Channel 100x50x2028mm (For TPMO,LA and Fuse set) |
| 109 | Holding Clamps for Top Channel TPMO & Fuse Set etc. with nuts, bolts & washers |
| 110 | GI Angle 75x75x6 mm, 2028 mm long with clamp for T/F base |
| 111 | 11kV Polymer Disc Insulator T&C type 45 KN |
| 112 | Disc Fittings T&C type 45 KN |
| 113 | 11 KV Composite Polymer Pin Insulator with Nut and washers as per TS |
| 114 | 11kV TPMO complete set |
| 115 | 11kV DO Fuse Set (3 Phase) |
| 116 | 11kV Lightening Arrestor (Set- 3 No) |
| 117 | G.I. Barbed Wire |
| 118 | 11kV MS Danger Board with clamp, bolts & nuts |
| 119 | SMCDistribution box as per technical specifications for 3 Ph 63 KVA DTR |
| 120 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS |
| 121 | Stay Wire 7/10 SWG |
| 122 | Chemical Pipe Earthing (80 mm dia, 3 m long Pipe) |
| 123 | LT PVC Cable3.5x70/35Sq.mm. |
| 124 | ACSR Weasel Conductor |
| 125 | Earthing of pole by MS earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. |
| 126 | GI Channel 100x50x2028mm (ForDistribution box)) |
| 127 | Concreting of Pole/Support as per TS |
| 128 | Construction of new 25 KVA, 11/0.433kV Distribution Transformer S/S |
| 129 | 11/0.44 kV 25 KVA Transformer (Level-I) as per specified in T.S. |
| 130 | PCC Pole, 8.5 Mtr. Long |
| 131 | Stone Pad (300x300x75mm) |
| 132 | GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers |
| 133 | GI Channel 100x50x2240mm (For TPMO,LA and Fuse set) |
| 134 | Holding Clamps for Top Channel TPMO & Fuse Set etc. with nuts, bolts & washers |
| 135 | GI Angle 75x75x6 mm, 2028 mm long with clamp for T/F base |
| 136 | 11kV Polymer Disc Insulator T&C type 45 KN |
| 137 | Disc Fittings T&C type 45 KN |
| 138 | 11 KV Composite Polymer Pin Insulator with Nut and washers |
| 139 | 11kV TPMO complete set |
| 140 | 11kV DO Fuse Set (3 Phase) |
| 141 | 11kV Lightening Arrestor (Set- 3 No) |
| 142 | G.I. Barbed Wire |
| 143 | 11kV MS Danger Board with clamp, bolts & nuts |
| 144 | SMCDistribution boxas per technical specifications for 3 Ph 25 KVA DTR |
| 145 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS |
| 146 | Stay Wire 7/10 SWG |
| 147 | Chemical Pipe Earthing (80 mm dia, 3 m long Pipe) as per TS |
| 148 | LT XLPE insulated unarmoured 4x25 Sq. mm.Cable |
| 149 | ACSR Weasel Conductor |
| 150 | Earthing of pole by MS earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. |
| 151 | GI Channel 100x50x2028mm (ForDistribution box)) |
| 152 | Concreting of Pole/Support as per TS |
| 153 | Installation of 11 KV Outgoing VCB for Feeder Segreration |
| 154 | 11KV Outgoing CTR 400/200/5A 350 MVA |
| 155 | 11 KV rearrangement for connecting new 11 KV VCB with existing 11 KV Switch gear (Adoptor Panel) |
| 156 | 11kV 3x185 mm2XLPE Cable |
| 157 | Heat Shrinkable outdoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size |
| 158 | Heat Shrinkable indoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size |
| 159 | 11 Mtr. Long Steel Tubular pole 410 SP 55 |
| 160 | GI Top Channel 100x50x2240 mm. |
| 161 | 11 KV Polymer Disc Insulator T&C type 45 KN |
| 162 | Disc Fitting T&C type 45 KN |
| 163 | 11 KV Composite Polymer Pin Insulator with Nut and washers |
| 164 | P.G. Clamp for ACSR Dog/Raccoon |
| 165 | 11kV \"E\" Bracket with N&B |
| 166 | 11kV MS Danger Board with clamp, bolts & nuts |
| 167 | 11kV Lightening Arrestor (Set- 3 No) |
| 168 | G.I. Barbed Wire |
| 169 | Aluminium Paint |
| 170 | Red Oxide Paint |
| 171 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS |
| 172 | Stay Wire 7/10 SWG |
| 173 | Earthing of pole by MS earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. |
| 174 | GI Strip 50x6 mm |
| 175 | G.I. Pipe 6\" dia . |
| 176 | Laying of 11 KV Cable including cost of Sand & Bricks |
| 177 | Concreting of Pole/Support as per TS |
| 178 | PVC 4x2.5 sq mm (Cu) |
| 179 | PVC2x2.5 sq mm (cu) |
| 180 | Control Room Extension |
| 181 | Extension of existing substationcontrol room building,Control Room size 6x6 mtrs.( as per annexure attached in tender documents.) |
| 182 | 11 KV Railway Crossing |
| 183 | 11 Mtr. Long Steel Tubular pole 410 SP 55 |
| 184 | Stone Pad (300x300x75mm) |
| 185 | 11kV 3x185 mm2XLPE Cable |
| 186 | Top channel 125x 65 mm 3200 mm (10,7kg/m) |
| 187 | M.S Angle iron 65x65x6 mm 4300 mm long bracing with clamp |
| 188 | Heat Shrinkable outdoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size |
| 189 | Laying of HDPE Pipe underground minimum 3 meters below the Railway track by HDD Method along with laying of 11 KV 3x185 Sqmm. XLPE Cable in G.I. Pipes. |
| 190 | HDPEPipe (6\" dia.) for laying UG below the Railway track by HDD Method. |
| 191 | G.I. Pipe 6\" dia. with Clamps |
| 192 | 11 KV Polymer Disc Insulator B&S type 70 KN |
| 193 | Disc Fitting B&S type 70 KN |
| 194 | P.G. Clamp for ACSR Dog/Raccoon |
| 195 | 11kV MS Danger Board with clamp, bolts & nuts |
| 196 | G.I. Barbed Wire |
| 197 | Aluminium Paint |
| 198 | Red Oxide Paint |
| 199 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS |
| 200 | Stay Wire 7/10 SWG |
| 201 | Earthing of pole by MS earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. |
| 202 | Concreting of Pole/Support as per TS |
| 203 | Railway Crossing Documentation, Land and Approval Fee etc. (Payment shall be done as per actual) |
| 204 | Digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of11 KV XLPE cables |
| 205 | Laying of 11 KV XLPE Cable in trenches and in G.I. Pipe on double pole |
| 206 | Number plate |
| 207 | 11 KV Polymer Pin Insulator |
| 208 | Cable Route Marker |
| 209 | NHAI/State Highway Crossing |
| 210 | 11 Mtr. Long Steel Tubular pole 410 SP 55 |
| 211 | 11kV 3x185 mm2XLPE Cable |
| 212 | Heat Shrinkable outdoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size |
| 213 | HDPE Pipe for cable laying (Pipe to be laid by HDD Method) |
| 214 | G.I. Pipe 6\" dia . |
| 215 | Laying of 11 KV XLPE Cable underground in trenches/ pipes. |
| 216 | Laying of 11 KV XLPE Cable in G.I. Pipe on double pole |
| 217 | Top channel 125x 65 mm 3200 mm |
| 218 | M.S Angle iron 65x65x6 mm 4300 mm long bracing with clamp |
| 219 | 11 KV Polymer Disc Insulator B&S type 70 KN |
| 220 | Disc Fitting B&S type 70 KN |
| 221 | P.G. Clamp for ACSR Dog |
| 222 | 11kV MS Danger Board with clamp, bolts & nuts |
| 223 | G.I. Barbed Wire |
| 224 | Aluminium Paint |
| 225 | Red Oxide Paint |
| 226 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS |
| 227 | Stay Wire 7/10 SWG |
| 228 | Earthing of pole by MS earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. |
| 229 | Concreting of Pole/Support as per TS |
| 230 | NHAI/State highway crossing documentation, land charges and approval fee etc. (Payment shall be done as per actual) |
| 231 | Road Restoration (Foot Path )charges |
| 232 | Bolts Nuts & washers |
| 233 | Aluminium winding wire - 6 SWG |
| 234 | Constructionof NewLTLineon(3x50+1x35+1x16)sq.mmLTABC Cable |
| 235 | PCC Pole, 8.5 Mtr. Long |
| 236 | Stone Pad (300x300x75mm) |
| 237 | Earthing complete with M.S. Earthing Rod 20x2500 mm. & GI wire 6 SWG |
| 238 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS |
| 239 | Stay Wire 7/10 SWG |
| 240 | Dead End clamp (Insulated) |
| 241 | Suspension clamps with I-Hook (Insulated) |
| 242 | Pole Clamps with nut & bolts for laying ABC |
| 243 | LT Insulating Piercing Connector (16sq.mm) suitable for street light |
| 244 | Insulating Piercing Connector (120-50 sq.mm -50-35 sq.mm) |
| 245 | SMC LT distribution boxes/kiosk, 3 phase on the LTPoles including all clamps & material required for mounting connections |
| 246 | Supply of LT ABC of 3x50+1x35+1x16 sq. mm |
| 247 | Erection of LT ABC of 3x50+1x35+1x16 sq. mm |
| 248 | 1x35 mm2 Un-armoured XLPE insulated Al. LT Cable for energising the distribution boxes. |
| 249 | 1x16 mm2 Un-armoured XLPE insulated Al. LT Cable for energising the street light |
| 250 | End cap for LT AB cable |
| 251 | PG Clamps |
| 252 | Concreting of PCC Pole/Support as per TS |
| 253 | Construction of New LT line on (3x95 + 1x70 +1x16)sq. mm LT ABC Cable |
| 254 | PCC Pole, 8.5 Mtr. Long |
| 255 | Stone Pad (300x300x75mm) |
| 256 | Earthing complete with M.S. Earthing Rod 20x2500 mm. & GI wire 6 SWG |
| 257 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS |
| 258 | Stay Wire 7/10 SWG |
| 259 | Dead End clamp (Insulated) |
| 260 | Suspension clamps with I-Hook (Insulated) |
| 261 | Pole Clamps with nut & bolts for laying ABC |
| 262 | LT Insulating Piercing Connector (16sq.mm) suitable for street light |
| 263 | Insulating Piercing Connector (120-50 sq.mm -50-35 sq.mm) |
| 264 | SMC LT distribution boxes/kiosk, 3 phase on the LTPoles including all clamps & material required for mounting connections |
| 265 | Supply of LT ABC of 3x95+1x70+1x16 sq. mm |
| 266 | Erection of LT ABC3x95+1x70+1x16 sq. mm |
| 267 | 1x35 mm2 Un-armoured XLPE insulated Al. LT Cable for energising the distribution boxes. |
| 268 | 1x16 mm2 Un-armoured XLPE insulated Al. LT Cable for energising the street light |
| 269 | End cap for LT AB cable |
| 270 | PG Clamps |
| 271 | Concreting of PCC Pole/Support as per TS |
| 272 | Overhead crossing of existing HT Line |
| 273 | 13 meter STP Pole-SP-70 |
| 274 | X-arm MS Angle 65X65X6mm V-Type 11 KV |
| 275 | Cross arm holding clamps with bolts & nuts |
| 276 | 11 KVpolymeric Pin Insulator |
| 277 | F-bracket for fitting top insulator with bolts & nuts |
| 278 | Danger Plate with clamps & bolts |
| 279 | Aluminium paint |
| 280 | Red oxide paint |
| 281 | Number marking on Polewith paint |
| 282 | Barbed wire GI |
| 283 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS |
| 284 | Stay Wire 7/10 SWG |
| 285 | Concreting of STP 13 M supports (@.63 Cu Mtr per pole) |
| 286 | Earthing of pole by MS earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. |
| 287 | Overhead crossing of existing LT Line |
| 288 | 11 meter STP Pole-SP-55 |
| 289 | X-arm MS Angle 65X65X6mm V-Type 11 KV |
| 290 | Cross arm holding clamps with bolts & nuts |
| 291 | 11 KVpolymeric Pin Insulator |
| 292 | F-bracket for fitting top insulator with bolts & nuts |
| 293 | Danger Plate with clamps & bolts |
| 294 | Aluminium paint |
| 295 | Red oxide paint |
| 296 | Number marking on Polewith paint |
| 297 | Barbed wire GI |
| 298 | Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS |
| 299 | Stay Wire 7/10 SWG |
| 300 | Concreting of STP 11 M supports (@.44 Cu Mtr per pole) |
| 301 | Earthing of pole by MS earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. |
| 302 | Additional items that may be required for completion of work |
| 303 | 9 MTR STP Pole |
| 304 | 3x120 sq. mm 11 kV AB Cable |
| 305 | 11kV Polymer Disc Insulator with Fitting for 11 KVABC |
| 306 | 11kV Polymer Disc Insulators with I-Hook |
| 307 | Heat Shrinkable 1 ph. termination kit outdoor for 11 kV 3x120 Sq. mm. AB Cable |
| 308 | Spacers LT PVC |
| 309 | LT Insulation Piercing Connectors of 95/50 sq. mm - 70/35 sq. mm (For messenger wire jumpering & energizing DB neutral) |
| 310 | On/Off switch for street light connections |
| 311 | Height raising channel 100X50,2240 mm long |
| 312 | Back clamp for height raising channel holding clamps with bolts & nuts |