Tender For 14 Apd Items 33421864 0003 0001 300070249 PLATE,P/N:M323551A,F/BUP,BUP,SMS Technical Details Name : Arpit Joshi Contact : Email : ARPIT.JOSHI@AMNS.IN 5 NO PLATE PART NO : M323551A , TYPE : SEAL , MAJOR EQUIPMENT : BUP MAJOR EQUIPMENT MODEL : BUP , MAJOR EQUIPMENT MAKE : SMS Item Details : Inspection clause: Vendor has to submit following reports, whichever is applicable: - Dimensional Inspection report - Material test certificate (Chemical <(>&<)> mechanical both) - NDT Report (UT, DP, MPT <(>&<)> Radiography (If required)) - Heat treatment report <(>&<)> Graph. - Hardness test report. - Impact test report. Item Note : 2 33421864 0005 0002 300152292 RING,P/N:322668A,F/BACK UP ASSEMBLY,SMS Technical Details Name : Arpit Joshi Contact : Email : ARPIT.JOSHI@AMNS.IN 11 NO RING PART NO : 322668 A , MAJOR EQUIPMENT : BACK UP ASSEMBLY MAJOR EQUIPMENT DRAWING NO : 62373 , MAJOR EQUIPMENT MAKE : SMS Item Details : Inspection clause: Vendor has to submit following reports, whichever is applicable: - Dimensional Inspection report - Material test certificate (Chemical <(>&<)> mechanical both) - NDT Report (UT, DP, MPT <(>&<)> Radiography (If required)) - Heat treatment report <(>&<)> Graph. - Hardness test report. - Impact test report. Item Note : 3 33421864 0006 0003 300070233 SPRING,P/N:84043B,F/TC,KWA,SMS Technical Details Name : Sumeet Padhi Contact : Email : SUMEET.PADHI@AMNS.IN 288 NO SPRING PART NO : 84043B , MAJOR EQUIPMENT : TC MAJOR EQUIPMENT MODEL : KWA , MAJOR EQUIPMENT MAKE : SMS Item Details : Inspection clause: Vendor has to submit following reports, whichever is applicable: - Dimensional Inspection report - Material test certificate (Chemical <(>&<)> mechanical both) - NDT Report (UT, DP, MPT <(>&<)> Radiography (If required)) - Heat treatment report <(>&<)> Graph. - Hardness test report. - Impact test report. Item Note : 4 33421864 0008 0004 300905262 PLATE,MTLC,PN:M323846A,PLAIN,MS Technical Details Name : Sumeet Padhi Contact : Email : SUMEET.PADHI@AMNS.IN 1 NO PLATE,METALLIC TYPE:PLAIN , MATERIAL:MILD STEEL , SURFACE PATTERN:PLAIN MAKE NAME:MORGOIL , MAKE PART NO:M323846A APPLICATION AREA EQUIPMENT:FINISHING MILL-1 BACKUP CHOCK DRAWING DRG NO:10078900 , DRAWING SELECT REFERENCE ATTRIBUTE:F Item Details : Inspection clause: Vendor has to submit following reports, whichever is applicable: - Dimensional Inspection report - Material test certificate (Chemical <(>&<)> mechanical both) - NDT Report (UT, DP, MPT <(>&<)> Radiography (If required)) - Heat treatment report <(>&<)> Graph. - Hardness test report. - Impact test report. Item Note : 5 33421864 0009 0005 300920477 RING,MTLC,PN:322697A Technical Details Name : Sumeet Padhi Contact : Email : SUMEET.PADHI@AMNS.IN 15 NO RING,METALLIC MAKE PART NO:322697A APPLICATION AREA EQUIPMENT:FINISHING MILL F2-F6 BACKUP CHOCK MAKE NAME:MORGOIL , DRAWING DRG NO:10078930 , DRAWING REV NO:F Item Details : Inspection clause: Vendor has to submit following reports, whichever is applicable: - Dimensional Inspection report - Material test certificate (Chemical <(>&<)> mechanical both) - NDT Report (UT, DP, MPT <(>&<)> Radiography (If required)) - Heat treatment report <(>&<)> Graph. - Hardness test report. - Impact test report. Item Note : Page 2 of 3 ArcelorMittal Nippon Steel India Limited AM/NS HAZIRA PLANT 27th KM, Surat-Hazira Road,,HAZIRA,394270,Gujarat,India GSTIN 24AAACE1741P1ZN PAN AAACE1741P CIN U27100GJ1976FLC013787 Request for Quotation Number 6000122318 Date 18.10.2024 Submission Date 25.10.2024 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ Mr. Amol Gaurkar Contact Email AMOL.GAURKAR@AMNS.IN MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Material / Service No. Quantity UOM Detail Description Other Details 6 33421864 0010 0006 300920475 RING,MTLC,PN:10078902 Technical Details Name : Sumeet Padhi Contact : Email : SUMEET.PADHI@AMNS.IN 2 NO RING,METALLIC MAKE NAME:MORGOIL , MAKE PART NO:10078902 DRAWING DRG NO:10078900 , DRAWING REV NO:F APPLICATION AREA EQUIPMENT:FINISHING MILL-1 BACKUP CHOCK Item Details : Inspection clause: Vendor has to submit following reports, whichever is applicable: - Dimensional Inspection report - Material test certificate (Chemical <(>&<)> mechanical both) - NDT Report (UT, DP, MPT <(>&<)> Radiography (If required)) - Heat treatment report <(>&<)> Graph. - Hardness test report. - Impact test report. Item Note : 7 33421864 0011 0007 300916540 BLOK,MTLC,PN:10078908 Technical Details Name : Sumeet Padhi Contact : Email : SUMEET.PADHI@AMNS.IN 2 NO BLOCK,METALLIC ADDITIONAL INFORMATION:F1 BUP ASSEMBLY NON THRUST SIDE LOCKING SEGMENT MAKE NAME:MORGOIL , DRAWING REV NO:F , MAKE PART NO:10078908 DRAWING DRG NO:10078900 Item Details : Inspection clause: Vendor has to submit following reports, whichever is applicable: - Dimensional Inspection report - Material test certificate (Chemical <(>&<)> mechanical both) - NDT Report (UT, DP, MPT <(>&<)> Radiography (If required)) - Heat treatment report <(>&<)> Graph. - Hardness test report. - Impact test report. Item Note : 8 33421864 0012 0008 300920374 BLOK,MTLC,PN:M323321A Technical Details Name : Sumeet Padhi Contact : Email : SUMEET.PADHI@AMNS.IN 2 NO BLOCK,METALLIC ADDITIONAL INFORMATION:MORGOIL LOCKING SEGMENT 52/56 TS MAKE NAME:MORGOIL , DRAWING REV NO:F , MAKE PART NO:M323321A DRAWING DRG NO:10078900 Item Details : Inspection clause: Vendor has to submit following reports, whichever is applicable: - Dimensional Inspection report - Material test certificate (Chemical <(>&<)> mechanical both) - NDT Report (UT, DP, MPT <(>&<)> Radiography (If required)) - Heat treatment report <(>&<)> Graph. - Hardness test report. - Impact test report. Item Note : 9 33421864 0013 0009 300920478 COVER,MTLC,PN:10078931 Technical Details Name : Sumeet Padhi Contact : Email : SUMEET.PADHI@AMNS.IN 2 NO COVER,METALLIC MAKE NAME:MORGOIL , MAKE PART NO:10078931 APPLICATION AREA EQUIPMENT:FINISHING MILL-1 BACKUP CHOCK DRAWING DRG NO:10078900 , DRAWING REV NO:F Item Details : Inspection clause: Vendor has to submit following reports, whichever is applicable: - Dimensional Inspection report - Material test certificate (Chemical <(>&<)> mechanical both) - NDT Report (UT, DP, MPT <(>&<)> Radiography (If required)) - Heat treatment report <(>&<)> Graph. - Hardness test report. - Impact test report. Item Note : 10 33421864 0014 0010 300920587 COVER,MTLC,PN:M323309A Technical Details Name : Sumeet Padhi Contact : Email : SUMEET.PADHI@AMNS.IN 2 NO COVER,METALLIC MAKE NAME:MORGOIL , MAKE PART NO:M323309A APPLICATION AREA EQUIPMENT:FINISHING MILL-1 BACKUP CHOCK DRAWING DRG NO:10078900 , DRAWING REV NO:F Item Details : Inspection clause: Vendor has to submit following reports, whichever is applicable: - Dimensional Inspection report - Material test certificate (Chemical <(>&<)> mechanical both) - NDT Report (UT, DP, MPT <(>&<)> Radiography (If required)) - Heat treatment report <(>&<)> Graph. - Hardness test report. - Impact test report. Item Note : Page 3 of 3 ArcelorMittal Nippon Steel India Limited AM/NS HAZIRA PLANT 27th KM, Surat-Hazira Road,,HAZIRA,394270,Gujarat,India GSTIN 24AAACE1741P1ZN PAN AAACE1741P CIN U27100GJ1976FLC013787 Request for Quotation Number 6000122318 Date 18.10.2024 Submission Date 25.10.2024 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ Mr. Amol Gaurkar Contact Email AMOL.GAURKAR@AMNS.IN MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Material / Service No. Quantity UOM Detail Description Other Details 11 33421864 0015 0011 300920825 RING,MTLC,PN:321398A Technical Details Name : Sumeet Padhi Contact : Email : SUMEET.PADHI@AMNS.IN 2 NO RING,METALLIC MAKE NAME:MORGOIL , MAKE PART NO:321398A APPLICATION AREA EQUIPMENT:FINISHING MILL-1 BACKUP CHOCK DRAWING DRG NO:10078900 , DRAWING REV NO:F Item Details : Inspection clause: Vendor has to submit following reports, whichever is applicable: - Dimensional Inspection report - Material test certificate (Chemical <(>&<)> mechanical both) - NDT Report (UT, DP, MPT <(>&<)> Radiography (If required)) - Heat treatment report <(>&<)> Graph. - Hardness test report. - Impact test report. Item Note : 12 33421864 0016 0012 300920851 PLATE,MTLC,PN:10221196 Technical Details Name : Sumeet Padhi Contact : Email : SUMEET.PADHI@AMNS.IN 2 NO PLATE,METALLIC MAKE NAME:MORGOIL , MAKE PART NO:10221196 APPLICATION AREA EQUIPMENT:FINISHING MILL-1 BACKUP CHOCK DRAWING DRG NO:10078900 , DRAWING REV NO:F Item Details : Inspection clause: Vendor has to submit following reports, whichever is applicable: - Dimensional Inspection report - Material test certificate (Chemical <(>&<)> mechanical both) - NDT Report (UT, DP, MPT <(>&<)> Radiography (If required)) - Heat treatment report <(>&<)> Graph. - Hardness test report. - Impact test report. Item Note : 13 33421864 0017 0013 300070156 SPRING,P/N:84043A,F/RS,KWA,TOSHIBA Technical Details Name : Sumeet Padhi Contact : Email : SUMEET.PADHI@AMNS.IN 100 NO SPRING PART NO : 84043A , TYPE : COMPRESSION , MAJOR EQUIPMENT : RS MAJOR EQUIPMENT MODEL : KWA , MAJOR EQUIPMENT MAKE : TOSHIBA Item Details : Inspection clause: Vendor has to submit following reports, whichever is applicable: - Dimensional Inspection report - Material test certificate (Chemical <(>&<)> mechanical both) - NDT Report (UT, DP, MPT <(>&<)> Radiography (If required)) - Heat treatment report <(>&<)> Graph. - Hardness test report. - Impact test report. Item Note : 14 33421864 0018 0014 300143331 BUMPER,134184 A;F/BACKUP ROLL ASEMBLY;F6 Technical Details Name : Sumeet Padhi Contact : Email : SUMEET.PADHI@AMNS.IN 2,000 NO BUMPER PART NO:134184 A , MAJOR EQUIPMENT:BACK UP ROLL ASSEMBLY MAJOR EQUIPMENT DRAWING NO:62375 , MAJOR EQUIPMENT MODEL:F6 MAJOR EQUIPMENT MAKE:SMS Item Details : Inspection clause: Vendor has to submit following reports, whichever is applicable: - Dimensional Inspection report - Material test certificate (Chemical <(>&<)> mechanical both) - NDT Report (UT, DP, MPT <(>&<)> Radiography (If required)) - Heat treatment report <(>&<)> Graph. - Hardness test report. - Impact test report