Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 08-11-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 15-11-2024 |
| 2 | 24-10-2024 | BoQ and Sch of credit | BOQ | 08-11-2024 |
| Sl. No. | Item Description |
| 1 | BR WORKS :- |
| 2 | Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting outin SOFT/LOOSE soil complete all as specified and directed. |
| 3 | Excavation in trenches n. exc 1.5 m wide for foundations, laying cables/ pipes etc. not exceeding 1.5 m deep and getting out in SOFT/LOOSE soil complete all as specified and directed. |
| 4 | Returning filling in including spreading, levelling, watering and well ramming in layers notexceeding 25cm thick complete all as specified and directed. |
| 5 | Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed. |
| 6 | M&L for PCC type E-2 (1:5:10), using 40 mm graded crushed stone aggregates as in filling & mass concrete, complete all as specified and directed. |
| 7 | M&L for PCC type C-2 (1:3:6), using 40 mm graded crushed stone aggregates as in filling & mass concrete, complete all as specified and directed. |
| 8 | M&L for Plain cement concrete, type B-0, (1:2:4), using 12.5 mm graded crushed stone aggregates in roof kerbs or mud stops, rounded or chamfered on edges etcand the like complete all as specified and directed. |
| 9 | M&L forPlain cement concrete, type B-1, (1:2:4), using 20 mm graded crushed stone crushedaggregates in roof kerbs or mud stops, rounded or chamfered on edges etcand the like complete all as specified and directed. |
| 10 | M&L forReinforced cement concrete, type B-1, (1:2:4), using 20 mm graded crushed stone aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, and in shelves and the like complete all as specified and directed. |
| 11 | M&L forBrick work using bricks as specified in PS clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified and directed. |
| 12 | M&L forBrick work in half brick thick wall using bricks as specified in PS clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:4), complete all as specified and directed. |
| 13 | Use & waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) with fair finished surfaces of concrete, complete all as specified and directed. |
| 14 | M&L forFactory made, 35 mm thick, second class hard wood,plain framed, hammer marked, skelton shutter (two panel to receive wire gauge) with lock rail . The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 15 | M&L forFactory made, flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, 35 mm thick, ISI marked, complete all as specified and directed. |
| 16 | M&L for Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded wood grain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and wood grain colour PVC sheet for top rail, lock rail and bottom rail, panelling of wood grain colour PVC sheet to be fitted in the MS frame welded / sealed to the stile and rails with suitable PVC sheet beading and jointed together with solvent cement as specified in SSR Part II, complete all as specified and directed. |
| 17 | M&L forFactory made solid PVC Door frame of size 50mm x 47mm made out of 5mm thick wood grain colour PVC sheet reinforcedwith mild steel square tube, suppling & fixing in opening, complete all as specified and directed. |
| 18 | S&F, Aluminium anodised barrel tower bolt of extruded section 150 mm long, ISI marked, complete all as specified and directed. |
| 19 | S&F, Aluminium alloy, anodised, ISI marked sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extrudedsections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy 300 mm long,complete all as specified and directed. |
| 20 | M&L for Stainless steel 100mm long butt hinges with stainless steel screws, ISI marked complete all as specified and directed.MAKE: PRAYAG CAT HG-3312 or equivalent make mentioned in Appendix \"B\" |
| 21 | S&F, Mild steel ordinary rat tail rod pattern helical door spring 250 mm long including roller and roller plate, complete all as specified and directed |
| 22 | S&F, Aluminium anodised handles cast type 75 mm long, ISI marked complete all as specified and directed. |
| 23 | S&F, Extruded aluminium anodised handles fabricated type with plate 125 mm long, ISI marked complete all as specified and directed. |
| 24 | S&F, Hasp and staple, safety type, aluminium anodised including bolt to hinge plate and fixed with screws of size 75 mm, ISI marked complete all as specified and directed. |
| 25 | S&F, Stainless steel conduit 20 mm bore, cut to size and erected in position as curtain rod on backets, with & including SS decorative finials & brackets, PVC rings @ 10 nos. per metre, fixed to walls with PVC rawl plugs & SS screws, IN REPAIRS, complete all as specified and directed. |
| 26 | S&F, Double leg aluminium anodised door stopper with rubber foot 100 mm long, ISI marked and fixed to bottom rail of doors with steel screws, complete all as specified and directed. |
| 27 | S&F, Stainless steel 100mm size auto soft closing hydraulic hinges fixed with stainless steel screws, ISI marked complete all as specified and directed. |
| 28 | M&L for Galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tacks or galvanized wire staples, complete all as specified and directed. |
| 29 | Framed mild steel work as in doors or gates of angle or other section with gusset plates, rails braces etc complete drilled for fixing steel sheeting or other covering door etc to be prepared for hanging door fittings (except steel sheeting) and hanging and similar work confirming to Fe-290-Gde E-165, complete all as specified and directed. |
| 30 | Rolled mild steel as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, quality confirming to grade Fe-290-Gde E-165, complete all as specified and directed. |
| 31 | Framed mild steel work such as grills, grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, railings and similar work confirming to Fe-290-Gde E-165, complete all as specified and directed. |
| 32 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 33 | M&L for Mild steel work as stairs (framed) including stringers, treades, landing, ballusters, hand rails etc. including cleats brackets quality confirming to grade Fe-290-Gde E-165, complete all as specified and directed. |
| 34 | S&F, Factory made pre painted pressed steel frames, conforming to IS,having profile 105 mm x 60 mm for doors with one or more rebates made out of 1.25 mm thick mild steel sheet, including necessary fixing lugs, butt hinges, lock strike plate, etc., duly filled with PCC(1:3:6) type C-0 complete, all as specified and directed. |
| 35 | S&F, Factory made pre painted pressed steel frames, conforming to IS,having profile 125 mm x 60 mm for doors with one or more rebates made out of 1.25 mm thick mild steel sheet, including necessary fixing lugs, butt hinges, lock strike plate, etc., duly filled with PCC(1:3:6) type C-0 complete, all as specified and directed. |
| 36 | S&F, Factory made steel windows with side hung shutter with glazng bars each shutter having 02 No. box type hinges & two nos. tower bolts of size not less than 150 mm size and peg stays, dovetailed or welded,including one shop coat of zink chromate primer complete all as specified and directed. |
| 37 | S&F, Factory made steel windows with side hung shutter without glazng barseach shutter having 02 No. box type hinges & two nos. tower bolts of size not less than 150 mm size and peg stays, dovetailed or welded,including one shop coat of zink chromate primer complete all as specified and directed. |
| 38 | S&F, Steel windows or ventilators, fixed type made of MS sheet 1.25 mm thick box type (primer coated), ERW hollow \"P\" section of size 60mm x 25 mm complete all as specified and directed.NOTES APPLICABLE TO SERIAL ITEM NO. 31 TO 33: (a) Profile section used under these items shall be \"P\" tube as shown in drawing No. CE/AF/STD-170/07, CE/AF/STD-171/07 and CE/AF/STD-172/07 as applicable. |
| 39 | Water Proofing Treatment to RCC roofs comprising of the following : - |
| 40 | Taking down existing water proofingtreatment (any no. of layers) from RCC roofs includingcleaning the surface including flashings and junction of parapet etc. with wire brushing & water to the entire satisfaction of EIC, complete all as specified and directed. |
| 41 | M&L for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate, laid to slope as directed by Engineer in Charge over RCC roofs as padding, ccomplete all as specified and directed. |
| 42 | M&L for Rendering15 mm thick (Average thickness) rendering on roof surface including flashings and junction of parapets etc., finished even and fairin cement mortar (1:4), using water proofing compound as recommended by manufacturers after brushing cement slurry @ 1.20 kg/Sqm, complete all as specified and directed. NOTE: Supply only WPC will be measured & paid for separately under respective item of BOQ. |
| 43 | M&L for APP based polymeric membrane laid on primed roofs & flashing by forced application using Butane torch and sealing all joints on primed surface by applying hot blown industrial grade bitumen @ 85/25 @ 1.20 kg/Sq.m over a coat of bitumenous primer @ 0.40 litre per square metre over clean RCC/plastered roof surfaces & flashings complete all as specified and directed. |
| 44 | M&L for 40 mm thick brick tiles are bedded over 15 mm thick cement mortar (1:4),and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on APP membrane complete all as specified and directed. |
| 45 | M&L for 40 mm thick brick tiles (exept tiles) are bedded over 15 mm thick cement mortar (1:4),and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on APP membrane complete all as specified and directed. |
| 46 | Water Proofing Treatment to RCC sunken surfaces comprising of : - |
| 47 | M&L for Rendering15 mm thick (Average thickness) rendering on sunken surfaes including flashings, finished even and fairin cement mortar (1:4), using water proofing compound as per recommended ratio, after brushing cement slurry @ 1.20 kg/Sq. m, complete all as specified and directed. NOTE: Supply only WPC will be measured & paid for separately under respective item of BOQ. |
| 48 | M&L forLDPE sheet 150 micron laid over applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq. m & adjoining vertical surfaces including applying bitumenous primer @ 0.40 litre per square metre over clean RCC/plastered roof surfaces complete all as specified and directed. |
| 49 | M&L for 18/19 mm thickhigh density moisture resistant (HDMR) board, flat pressed, fixed as in modular kitchen cabinets, cupboards or similar works with necessary screwscomplete all as specified and directed. |
| 50 | M&L for 25 mm thick, cement concrete type B-0, 1:2:4 using 12.5 mm graded crushed stone aggregate, finished even & rough, as in sub floors, complete all as specified and directed. |
| 51 | M&L for 100 mm thick, cement concrete type D-2, 1:4:8 using 40 mm graded crushed stone aggregate, finished even & rough, as in sub floors, complete all as specified and directed. |
| 52 | M&L for 75 mm thick, cement concrete type C-1, 1:3:6 using 20 mm graded crushed stone aggregate, finished even & smooth without using extra cement, as in plinth protection,and joints shall be sealed with joint sealing comound grade \"A\" complete all as specified and directed. |
| 53 | M&L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc., and brushing a coat of cement slurry with 3 kg of cement per Sq.m, complete all as specified and directed. |
| 54 | M&L for Granite jet black shade, 15-18 mm thick,as in step, jambs, cooking platform and like, machine cut, machine polished,bedded and jointed with grey cement slurry & pointed with grout of matching shade including necessary cutting over & including 10 mm thick (average thickness) cement mortar (1:4), complete all as specified and directed. |
| 55 | M&L for Rounding of / moulding to edges (half round) of stone of any description including rubbing and polishing (Granite finish), complete all as specified and directed. |
| 56 | M&L for Glazed ceramic coloured tiles 7mm thick,area of each tile exc. 0.17 Sq.m but n. exc. 0.19 Sq.m on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 10 mm thick bedding layer in cement mortar (1:4), complete all as specified and directed. |
| 57 | M&L for Non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exc. 0.11 Sq.m but n. exc. 0.18 Sq.m,laid in floors etc, set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 15 mm thick bedding layer in cement mortar (1:4), complete all as specified and directed. |
| 58 | M&L for Non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exc. 0.11 Sq.m but n. exc. 0.18 Sq.mon vertical surfaces as in skirting etc. set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 10 mm thick bedding layer in cement mortar (1:4), complete all as specified and directed. |
| 59 | M&L for 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of shape approved by GE, made by table vibratory method using PU mould, laid in required pattern over and including 50mm thick compacted bed of coarse sand, compacting through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. |
| 60 | M&L forRepairing of RCC projection chhajjas, roof, facia etc by necessary preparation. Scraping cutting, chiseling derusting and cleaning of exposed reinforcement with antirust zink nich prime solution and a coat of bonding agent, surfaces of damaged, loose RCC with micro concrete 20 to 30mm thick and reinforcement with chicken mesh of weight not more than n.exc 3 kg/Sq.m (if reqd) with or without facia and finished with cement and sand mortar (1:3) using coarse sand and work in patches of area n.exc 5 Sq.m and thickness of RCC member n.exc 70 mm incl necessary formworkat any height/location complete all as specified and directed. NOTE: The rate quoted by the contractor shall included for chicken mesh, scaffolding and necessary formwork upto triple storey bldg. |
| 61 | M&L for Rendering 5 mm thickon fair faces of concrete surfaces, finished even and smooth on ceiling in cement mortar (1:3), complete all as specified and directed. |
| 62 | M&L for Rendering 15 mm thickon fair faces of brick work or concrete surfaces, finished even and fairon walls in cement mortar (1:6)complete all as specified and directed. |
| 63 | M&L for Rendering 15 mm thickon fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4), mixed with water proofing compound as per manufacturers instructions, complete all as specified and directed.NOTE: WPC will be measured and paid for separately under respective item of BOQ. |
| 64 | Supply only water proofing compound, ISI marked, complete all as specified and directed. |
| 65 | M&L for Two coat of white washing on old decorated ceiling surfaces, including preparation of surfaces, complete all as specified and directed. |
| 66 | M&L for Three coats of white washing on new undecorated ceiling surfaces, including preparation of surfaces, complete all as specified and directed. |
| 67 | M&L for Two coats of interior acrylic distemper/oil bound distemper on wall surfaces, including preparation of surfaces, complete all as specified and directed. |
| 68 | Prepration of new plasterd wall surfaces of any description complete all as specified and directed and applying the following: -(a) Applying wall care putty, in two coats& smoothening the surfaces as specified. (preparatory to paint as directed).(b) Two coats of interior acrylic distemper/oil bound distemper over and including a coat of interior primer. |
| 69 | Prepration of new plasterd wall surfaces of any description complete all as specified and directed and applying the following: -a) Applying wall care putty, in two coats& smoothening the surfaces as specified. (preparatory to paint as directed).complete all as specified and directed. (b) Two coats of exterior acrylic emulson over and including a coat of water based exterior primer complete all as specified and directed. |
| 70 | M&L for Prepration of wall surfaces of any description and applying two coats of exterior acrylic emulsion paint over and including a coat ofwater based exterior primer complete all as specified and directed |
| 71 | S&F, Plain sheet glass 4mm thick ordinary quality and glazing with oil putty or wooden beads in squares n. exc. 0.5 Sq.min each pane complete all as specified and directed. |
| 72 | S&F, Figured glass 4mm thick ordinary quality and glazing with oil puttyin squares n. exc. 0.5 Sq.min each pane complete all as specified and directed. |
| 73 | M&L forApplying one coat (finishing coat) of synthetic enamel paint, including preparation of old painted wood and wood basedsurfaces of any description not other wise described over 10cm width or girth and complete all as specified and directed. |
| 74 | M&L for Two coatsof synthetic enamel paint over & including a coat of pink primer over wood and wood based surfaces of any description not other wise described over 10cm width or girth including preparation of surfaces, complete all as specified and directed. |
| 75 | M&L for Applying one coat (finishing coat) of synthetic enamel paint including peparation of old painted steel & iron surfaces of any description not other wise described over 10cm width or girth, complete all as specified and directed. |
| 76 | M&L forTwo coatsof synthetic enamel paint over & including a coat of red oxide primer over steel or iron surfaces of any description not other wise described over 10cm width or girth including preparation of surfaces, complete all as specified and directed. |
| 77 | S&F, 500 litre capacity, white, three layered polyethylene water storage tanks (cylindrical vertical with threaded lid) including hoisting and fixing in position, making connections, IN REPAIRS, complete all as specified & directed including the following acessories: -(i) Gun metal ball valves, high pressure, with metal rod & high density plastic ball complete screwed for iron pipe or brass ferrule and fixed, IN REPAIRS, suitable for 20 mm bore GI pipe.(iii) Gun-metal stop valve (quarter turn type)with MS lever handle, suitable for 20 mm bore GI tubes, ISI marked, screwed both ends for iron pipe, IN REPAIRS.(iv) Provn of 20 mm bore GI light grade tube from O/H tank to nearest mouth of RWP, IN REPAIRS. |
| 78 | S&F, Steel tubes 15 mm bore ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors, complete all as specified and directed. |
| 79 | S&F, Steel tubes 20 mm bore ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors, complete all as specified and directed. |
| 80 | S&F, Angular stop valve/cock, cast copper alloy, chromium plated, with wall flange,quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete all as specified and directed. MAKE: PRAYAG Cat No. 6510 or equivalent make mentioned in Appendix \"B\". |
| 81 | S&F, Bib tap, cast copper alloy, chromium plated fancy type, long body with wall flange,quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete all as specified and directed. MAKE: PRAYAG Cat No. 6508 or equivalent make mentioned in Appendix \"B\". |
| 82 | S&F, Pillar tap, cast copper alloy, chromium plated fancy type, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete all as specified and directed. MAKE: KEROVIT Cat No.KB1211001 or equivalent make mentioned in Appendix \"B\". |
| 83 | S&F, Brass chromium plated towel rail500-600 mm long, fixed to wall with SS screws and PVC rawl plugs, complete all as specified and directed. MAKE: PRAYAG Cat No. BA-10 or equivalent make mentioned in Appndix \"B\". |
| 84 | S&F, Looking mirror 600 x 600 mm, selected quality glass 5.5 mm thick, mounted on PVC ply not less than 4 mm thick, and provision of PVC frame alround fixed with chromium plated brass screws and rawl plugs, IN REPAIRS, complete all as specified and directed. MAKE: PRAYAG Cat No. 553 or equivalent make mentioned in Appendix \"B\". |
| 85 | S&F, Glass shelf 500x125 mm with brass brackets and fixed to wall with chromium plated brass screws and rawl plugs, complete all as specified and directed. MAKE: PRAYAG Cat No. BEA-45 or equivalent make mentioned in Appendix \"B\". |
| 86 | S&F, Stainless steel soap dish, fixed to wall with SS screws and PVC rawl plugs, complete all as specified and directed. MAKE: PRAYAG Cat No. BA-05 or equivalent make mentioned in Appendix \"B\". |
| 87 | S&F, Stainless steel round slotted grating with frame, 100 mm size fixed in position with cement joints,complete all as specified and directed. |
| 88 | S&F, Stainless steelpeg set of six, fixed to wall with SS screws and PVC rawal plugs,complete all as specified and directed. MAKE: PRAYAG Cat No. BEA-30 or equivalent make mentioned in Appendix \"B\". |
| 89 | S&F, PVC connections with PTMT nuts, 450 mm long, IN REPAIRS, complete all as specified and directed. |
| 90 | S&F, PVC flushing cistern 10 litre capacity, syphonic action type, any shade, dual flush, ISI marked with flush pipe and all fixing acessories, IN REPAIRS, complete all as specified and directed.MAKE: PRAYAG Cat No. 502 or equivalent make mentioned in Appendix \"B\" |
| 91 | S&F, Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm, ISI marked, white, with integral foot rests (excluding flushing cistern and flush pipe), 110 x 125mm size uPVC \"P\" trap & necessary joints, lime concrete IN REPAIRS, complete all as specified and directed.MAKE: PRAYAG Cat No. 4055 or equivalent make mentioned in Appendix \"B\" |
| 92 | S&F, Vitreous China wash basin, white, flat back, size 550 x 400 mm, ISI marked,including fixing acessories like rag bolts etc. with CP waste coupling half or full threaded suitable for & including 32 mm size PVC solid waste pipe,IN REPAIRS, complete all as specified and directed. MAKE: PRAYAG Cat No. 4645 or equivalent make mentioned in Appendix \"B\" |
| 93 | S&F, Stainless steel (SS-304) sink made out of 1.00mm thick sheet for kitchen or laboratory with plug waste pipe washers including cantilever cast iron brackets connecting union etc overall size460mm x 405mm x 203mmwith bowl size 405mm x 354mm x 203mm, IN REPLACEMENT complete all as specified and directed. MAKE: PRAYAG Cat No. 1316D or equivalent make mentioned in Appendix \"B\". |
| 94 | S&F, uPVC pipes 75 mm external dia, type-B, ISI marked (IS:13592) single socketed in any length with or without rubber ring joints, fixed under floors/walls as SWR pipes, IN REPAIRS, complete all as specified and directed. |
| 95 | S&F, uPVC pipes 110 mm external dia, type-B, ISI marked (IS:13592) single socketed in any length with or withou rubber ring joints, fixed under floors/walls as SWR pipes, IN REPAIRS, complete all as specified and directed. |
| 96 | S&F, uPVC/PVC bend any radius, suitable for uPVC soil waste discharge pipes 75 mm external dia,IN REPAIRS, complete all as specified and directed. |
| 97 | S&F, uPVC/PVC bend any radius, suitable for uPVC soil waste discharge pipes 110 mm external dia,IN REPAIRS, complete all as specified and directed. |
| 98 | S&F, uPVC floor trap,suitable for uPVC soil waste discharge pipes 75 mm ext dia, embedded in PCC type B-1(1:2:4), IN REPAIRS, complete all as specified and directed, |
| 99 | EM WORKS :- |
| 100 | M&L for Point wiring with multi-stranded copper conductor, single core, FRLSH PVC insulated and unsheathed cable, including FRLSH PVC insulated unsheathed stranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes with 3 mm thick plastic laminated sheet cover having necessary cutting for fixing switches/ socketscomplete all as specified and directed, comprising the following: - |
| 101 | One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit. |
| 102 | NOTES: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule \"A\". (b) GI terminal boxes shall be fixed flushto walls in position with cement mortar (1:4).(c) Conduit shall be laid on surface in case of RCC ceiling surfaces. |
| 103 | S&F, Switch piano flush button single pole one way, 6 Amp complete all as specified and directed. |
| 104 | S&F, Ceiling rose, surface bakelite, 65 x 50mm, three terminals complete all as specified and directed, |
| 105 | S&F, Fan regulator (electronic) suitable for 48”/56” sweep fan, step down type, single phase, complete all as specified and directed. |
| 106 | S&F, Surface mounted environment friendly batten with powder coated aluminium housing LED 20 W lighting , 6500K, lumen output should not be less than 90 lumens per watt complete all as specified and directed, MAKE: Havells Cat No. ENDURALINEARNEOBS20WLED865SPCWH or equivalent in makes mentioned in Appendix \"B\" here-in-after. |
| 107 | S&F, Ceiling fan1200 mm sweep, with down rod, BLDC motor, 230 V having minimimum delivery 210 CFM with 6 BEE, 5 star rated fixed to ceiling and connecting up complete from ceiling rose or connector to fan, complete all as specified and directed, MAKE: Havells Cat No. FHCEO5SWHT48 or equivalent in makes mentioned in Appendix \"B\" here-in-after. |
| 108 | WORK SERVICES FOR INSTALLATION OF STATIC AIRCRAFT ARRESTING GEARS (AAGs) :- |
| 109 | Excavation over areasnot exceeding 1.5 m deep and getting out in SOFT/LOOSE soilcomplete, all as specified. |
| 110 | Removing excavated materialto a distance exceeding 250 metre but not exc 1.0 KM and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified. |
| 111 | M&L forPCC type D-2 (1:4:8), using 40 mm graded crushed stone aggregates as in filling & mass concrete, complete all as specified and directed. |
| 112 | Use & waste of formwork to sides of concrete fdns and footing sides, complete all as specified and directed. |
| 113 | M&L forPlain cement concrete, type B-1, (1:2:4), using 20 mm graded crushed stone aggregates in foundation, filling and mass concrete complete all as specified and directed. |
| 114 | M&L for forming contraction (Dummy) Joints 65mm deep X 10mm Wide, filled with Grade B Sealing compound complete all as specified and directed |
| 115 | DISMANTLING/DEMOLITION WORKS :- |
| 116 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sq.m each and removing from site all as specified and directed. |
| 117 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 Sq.m but not exceeding 4.00 Sq.m each and removing from site all as specified and directed. |
| 118 | Taking down shutters of any description exceeding 1 Sq. m but not exceeding 2 Sq. m each and removing from site all as specified and directed. |
| 119 | Taking down shutters of any description exceeding 1 Sq. m but not exceeding 2 Sq. m each, including stacking at directed location and refixingthe same on original or new location after resecuring or easing & adjusting, complete all as specified and directed. |
| 120 | Taking down cement plaster of any description on brick walls or concrete surfaces etcincluding raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 121 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 122 | Taking up or down steel tubing 15 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified and directed. |
| 123 | Taking up or down steel tubing 20 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified and directed. |
| 124 | Demolition brickwork or stone / boulder masonrybuilt in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.d |
| 125 | Demolition of cement concreteof any description and in any position not otherwise specifically provided all as specified. |
| 126 | Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 127 | Demolition of mud phuska in roofs, any thickness including plaster and leeping plaster all as specified. |
| 128 | Dismantlig brick tiles in roof laid dry and pointed in cement mortar all as specified. |
| 129 | Dismantling boarding any description fixed in any position with screws complete all as specified and directed. |
| 130 | Notes:Amount ofcredit for retrieved materials is mentionedintender documents in pdf form which will be deducted while acceptance of tender offline. |