| 1 | 1) The estimated amount is exclusive of GST.2) The Bidder should quote basic rates exclusive of GST and quote GST percentage separately. GST should be revised from time to time. |
| 2 | Supply, Installation, Testing and Commissioning of1250KVA transformer with 1250KVA, 11/0.433 KV,3 phase, 50 Hz, outdoor, ONAN type, delta star (Dyn11), copper wound, oil cooled, power transformer confirming tolevel-2 IS 1180 as new amendment-4 (part-1), with On load tapping of+5% to –5% in 10 equal steps /11 Positions of 2.5% on 11 KV side (primary), having 11 KV cable end termination box on primary side suitable to connect2 x 150 sq.mm, 11 KV grade, XLPE aluminium conductor power cable and secondary side cable end box suitable for connecting 4 x 300 Sq.mm XLPE insulated, 1.1 KV grade aluminium conductor power cable, with neutral brought out separately including , suitable mounting on M.S. channel with all accessories and confirming to IS 2026 (part-1 to Part 5) & CBIP specificationsincluding transportation of the transformer, connections etc. complete as required along with the following accessories and protection complete etc as required.Note:-The work shall be included Dismantling of existing 500 KVA Trasformer along with Termination etc.1) Dehydrating Silica gel Breather2) Explosion vent with Diaphragm3) Marshalling box for OTI & WTI 4) Winding temperature and indicator with alarm and trip 5) Oil temperature indicator with alarm and trip6) Magnetic oil level gauge-Alarm and trip7) Buchholz\"s relay with alarm and trip contract8) Base channel & Unidirectional wheels9)Earthing terminals10) First filling of dehydrated transformer oil11) Radiator as per standard design of manufacturer12) Lifting lugs13) Thermometer Pocket, 14) Air Release hole with Plug,15)Conservator with oil filling cap and drain plug16) Drain cum bottom filter valve with plug17) Top oil filter valve with plug, 18) Pressure relief valve19) Inspection cover20) Sampling valve at bottom 21) Uni-directional wheels & Base channels22) Rating & Diagram plate 23) Automatic voltage relay24) On load circuit Tap changerMaker: Kirloskar/Crompton/ABB |
| 3 | Sub Head-III (Cable Laying): Supply of 3.5 core x 300 sqmm XLPE insulated PVC outer sheathed Aluminium Armoured cable etc as required.Make: Finolex/Polycab/Havells. |
| 4 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 185 sq. mm and upto 400 sq. mm |
| 5 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 300 sq. mm (70mm) Make: Raychem/3M |
| 6 | supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 120 sq. mm |
| 7 | Sub Head-III (EARTHING):Earthingwithcopperearthplate600mmX 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover platehavinglockingarrangementand wateringpipeof2.7metrelongetc.With charcoal/ coke and salt as required. |
| 8 | Providingandfixing25mmX5mmcopper strip in 40 mm dia G.I.pipe from earth electrode including connection with brass nut,bolt,spring,washerexcavationandre-filling etc. as required. |
| 9 | Providingandfixing25mmX5mmcopper strip on surface or in recess for connections etc. as required. |
| 10 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Mtr long etc. with charcoal/ coke and salt as required. |
| 11 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 12 | Providing and fixing 25 mm X 5 mm G.I. Strip on surface or in recess for connections etc. as required. |
| 13 | Sub Head-III (Civil work): Coursed rubble masonry (second sort) with hard stone in foundation & plinth with : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 14 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 15 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge. |