| 1 | Excavationforfoundationinhardmurum includingremovingtheexcavatedmaterialupto distanceof50metresbeyondthebuilding areaandstackingandspreadingasdirected, dewatering,preparing thebedforthefoundationandnecessarybackfilling,ramming, wateringincludingshoringandstruttingetc.complete.By Mechanical Means(Spec. No. : Bd.A. 2 Page 259/CSR I Page No. 148 |
| 2 | Excavationforfoundationinhardmurum includingremovingthe excavatedmaterialupto distanceof50metresbeyondthebuilding areaandstackingandspreadingasdirected, dewatering,preparing thebedforthefoundationandnecessarybackfilling,ramming, wateringincludingshoringandstruttingetc.complete.By Mechanical Means(Spec. No. : Bd.A. 2 Page 259/CSR I Page No. 148 |
| 3 | Providingdry/trap/granite/quartzite/gneissrubblestonesoling15 cmto20cmthick including hand packing and compacting etc. complete. |
| 4 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-10oftrap/granite/ quartzite/gneissmetalforfoundationand beddingincludingbailingoutwater,Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided,finishingifrequiredandcuringcomplete,withfully automaticmicroprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 5 | Providing and laying in situ /Ready Mixcement concreteM-20of trap /granite /quartzite/ gneiss metalforR.C.C.work infoundationslike raft,stripfoundations,grillageand footingsofR.C.C.columnsand steelstanchions etc.includingbailingoutwater, Steel centering formwork,laying/pumpingcoverblocks,compactionandcuring roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 6 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20 oftrap/granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 7 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20 oftrap/granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 8 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20 oftrap/granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 9 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20 oftrap/granite/quartzite / gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand rougheningthesurfaceifspecialfinishistobeprovidedandcuring etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 10 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20 oftrap/granite/quartzite / gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand rougheningthesurfaceifspecialfinishistobeprovidedandcuring etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 11 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20 oftrap/granite/quartzite / gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand rougheningthesurfaceifspecialfinishistobeprovidedandcuring etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 12 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20 oftrap/granite/ quartzite/ gneiss metal for R.C.C.slabs andlandings asper detaileddesigns anddrawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish isto be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 13 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20 oftrap/granite/ quartzite/ gneiss metal for R.C.C.slabs andlandings asper detaileddesigns anddrawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish isto be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 14 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20 oftrap/granite/ quartzite/ gneiss metal for R.C.C.slabs andlandings asper detaileddesigns anddrawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish isto be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 15 | Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneissmetalforbedblocks, foundationblocksand suchotheritems includingbailingoutwater, Steelcentering,formwork,laying/pumping,compacting, roughening themifspecialfinishistobeprovided,finishingunevenand honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulinetc.(Woodencenteringwillnotbeallowed.),withfully automaticmicro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Crushed sand VSI Grade) |
| 16 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM- 20oftrap/granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork,coverblocks,laying/pumping,compacting,curing, finishingand rougheningthemifspecialfinishistobeprovidedand curingcomplete.(Excluding reinforcementandstructuralsteel).with fullyautomaticmicroprocessorbasedPLCwith SCADAenabled reversibleDrumTypemixer/concreteBatchmixplant(Panmixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 17 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C.pilecaps,footings,foundations,slabs,beamscolumns, canopies,staircase,newels, chajjas,lintelspardis,copings,fins, archesetc.asperdetaileddesigns,drawingsand schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 18 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C.pilecaps,footings,foundations,slabs,beamscolumns, canopies,staircase,newels, chajjas,lintelspardis,copings,fins, archesetc.asperdetaileddesigns,drawingsand schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 19 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C.pilecaps,footings,foundations,slabs,beamscolumns, canopies,staircase,newels, chajjas,lintelspardis,copings,fins, archesetc.asperdetaileddesigns,drawingsand schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 20 | Filling in plinth and floors with contractorsmaterial/brought from outsideand approved by Engineerincharge inlayersof15cm to20cm includingwateringandcompactionetc.complete. |
| 21 | Providing secondclassBurntBrickmasonrywithconventional/I.S. typebricksincement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposedfaces, raking out joints on exposedfaces and watering etc. Complete. |
| 22 | Providing secondclassBurntBrickmasonrywithconventional/I.S. typebricksincement mortar1:6insuperstructureincludingstriking joints,rakingoutjoints,wateringandscaffolding etc. Complete |
| 23 | Providing secondclassBurntBrickmasonrywithconventional/I.S. typebricksincement mortar1:6insuperstructureincludingstriking joints,rakingoutjoints,wateringandscaffolding etc. Complete |
| 24 | Providing secondclassBurntBrickmasonrywithconventional/I.S. typebricksincement mortar1:6insuperstructureincludingstriking joints,rakingoutjoints,wateringandscaffolding etc. Complete |
| 25 | Providinginternalcementplaster12mm thickinsinglecoatin cementmortar1:4without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc.complete. |
| 26 | Providinginternalcementplaster12mm thickinsinglecoatin cementmortar1:4without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc.complete. |
| 27 | Providinginternalcementplaster12mm thickinsinglecoatin cementmortar1:4without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc.complete. |
| 28 | Providingroughcastcementplasterexternallyintwocoatsto concrete,brickorstone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough casttreatment12mm thickin proportion1:11/2:3including scaffolding andfourteendays curing complete. |
| 29 | Providingroughcastcementplasterexternallyintwocoatsto concrete,brickorstone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough casttreatment12mm thickin proportion1:11/2:3including scaffolding andfourteendays curing complete. |
| 30 | Providingroughcastcementplasterexternallyintwocoatsto concrete,brickorstone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough casttreatment12mm thickin proportion1:11/2:3including scaffolding andfourteendays curing complete. |
| 31 | Providing and laying matt finish ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. |
| 32 | Providing and laying matt finish ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. |
| 33 | Providing and laying matt finish ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. |
| 34 | Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete. |
| 35 | Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete. |
| 36 | Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete. |
| 37 | Providing and applying plastic emulsion paint of approved quality, colour and shade tonew surface in three coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete. |
| 38 | Providing and applying plastic emulsion paint of approved quality, colour and shade tonew surface in three coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete. |
| 39 | Providing and applying plastic emulsion paint of approved quality, colour and shade tonew surface in three coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete. |
| 40 | Providing and applying two coats of exteriorweather shield paint of approved manufacture andofapprovedcolourtotheplastered surfacesincludingcleaning,preparingtheplaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etccomplete.NOTE: ForItem Number 15 to 18 prior approval of Superintending Engineer will be necessary |
| 41 | Providing and applying two coats of exteriorweather shield paint of approved manufacture andofapprovedcolourtotheplastered surfacesincludingcleaning,preparingtheplaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etccomplete.NOTE: ForItem Number 15 to 18 prior approval of Superintending Engineer will be necessary |
| 42 | Providing and applying two coats of exteriorweather shield paint of approved manufacture andofapprovedcolourtotheplastered surfacesincludingcleaning,preparingtheplaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etccomplete.NOTE: ForItem Number 15 to 18 prior approval of Superintending Engineer will be necessary |
| 43 | Providing and fixing Country cut teak wood single leaf door shutter with teak wood style and rail of 25 mm thick including fixing 50 mm x 25 mm size welded mesh of 10 gauge as per detailed drawing or as directed with stainless steel fixture and fastening finishing with 3 coats of oil painting etc. complete. |
| 44 | Providing and fixing Country cut teak wood single leaf door shutter with teak wood style and rail of 25 mm thick including fixing 50 mm x 25 mm size welded mesh of 10 gauge as per detailed drawing or as directed with stainless steel fixture and fastening finishing with 3 coats of oil painting etc. complete. |
| 45 | Providing and fixing Country cut teak wood single leaf door shutter with teak wood style and rail of 25 mm thick including fixing 50 mm x 25 mm size welded mesh of 10 gauge as per detailed drawing or as directed with stainless steel fixture and fastening finishing with 3 coats of oil painting etc. complete. |
| 46 | Providing and fixing in position. (as per I.S.1868 / 1982) Aluminiumsliding window of two trackswithrectangularpipe having overall dimension63.50x38.10x1.02mm atweight0.547 Kilogram/Running metre. and window frame bottom track section61.85 x 31.75 x 1.20 mm atweight0.695Kilogram/Running metre.Top andside track section61.85x31.75x1.30 mm at weight 0.659 Kilogram/Running metre. Theshutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre.Interlocking section40x18x1.10mm at weight0.469Kilogram/Runningmetre. Andhandle section40 x18 x1.25mm at weight0.417Kilogram/Running metre. andtop section40x18x1.25mmatweight0.417Kilogram/Runningmetre.Asper detailed drawingsandasdirectedbyEngineerinchargewithall necessaryAluminiumsections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With colour Anodising without box |
| 47 | Providing and fixing in position. (as per I.S.1868 / 1982) Aluminiumsliding window of two trackswithrectangularpipe having overall dimension63.50x38.10x1.02mm atweight0.547 Kilogram/Running metre. and window frame bottom track section61.85 x 31.75 x 1.20 mm atweight0.695Kilogram/Running metre.Top andside track section61.85x31.75x1.30 mm at weight 0.659 Kilogram/Running metre. Theshutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre.Interlocking section40x18x1.10mm at weight0.469Kilogram/Runningmetre. Andhandle section40 x18 x1.25mm at weight0.417Kilogram/Running metre. andtop section40x18x1.25mmatweight0.417Kilogram/Runningmetre.Asper detailed drawingsandasdirectedbyEngineerinchargewithall necessaryAluminiumsections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With colour Anodising without box |
| 48 | Providing and fixing in position. (as per I.S.1868 / 1982) Aluminiumsliding window of two trackswithrectangularpipe having overall dimension63.50x38.10x1.02mm atweight0.547 Kilogram/Running metre. and window frame bottom track section61.85 x 31.75 x 1.20 mm atweight0.695Kilogram/Running metre.Top andside track section61.85x31.75x1.30 mm at weight 0.659 Kilogram/Running metre. Theshutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre.Interlocking section40x18x1.10mm at weight0.469Kilogram/Runningmetre. Andhandle section40 x18 x1.25mm at weight0.417Kilogram/Running metre. andtop section40x18x1.25mmatweight0.417Kilogram/Runningmetre.Asper detailed drawingsandasdirectedbyEngineerinchargewithall necessaryAluminiumsections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With colour Anodising without box |
| 49 | Providing and Fixing cladding .025 m thick of jodhpur pink sandstone approved quality vein and color with machine polished surface , including embossing, carving, hand polishing, fixing, installation, grinding etc including scaffolding, transportation of all materials etc. as per detailed drawings provided by the project consultant/ architect if required cement plaster 1:4 with readymade adhesive including filling joints, cleaning, Applying anti moss treatment along with buffing on surfaces of stone with specified chemical approved by engineer in charge etc complete |
| 50 | Providing and Fixing the tensile structure and PVC fabric with detailed, inclusive of fabrication and installation of tensile structure. Most aesthetic looking, high quality level protection against envi- ronmental influence.Providing and fixing the tensile structure and PVC fabric with de- tailed, inclusive of fabrication and installation of tensile structure.The work shall include the MS. Peripheral column/beam welded purlins. The fabric shall be fixed to column/beam assembly and intermediate purling with necessary accessories etc. complete as per design and drawing of structural design. (Apollo pipe 4 mm+) Installation & tensioning of membrane (fabric) as per the design.All ms structure should be finished with epoxy primer and two coat spray epoxy paint as per approved make direction. Fabric details; Ferrari/Sattler PRO-TEX (669 10B type II) 900 gsm pvdf 15 years warranty as per company schedule.Approximate areaHalf round roofing 13*29-377 sqmt(4057 sqft)10% of arch 406 sqft. 4460 sqft (area change as per surface area of fabric)4460 sqftCivil work will like footing/foundation which necessary for Columare in customer scope.Design as per IS; 875, supply and installation of suitable MS structure |
| 51 | Supply of Complete kit of Prefabricated Building - Components (Bamboo)Includes: Structural members like columns, A-Frame truss members, Purlions etc. fabricated using treated bamboo polesIncludes: Non-structural members like flattened Bamboo splits/Thick Bamboo woven-mats (as base-layer for roof and for Gable End closure)Includes: specialy designed gusset plates for anchoring of bamboo columns into the plinth beam, other necessary hardware for assembly and installation on site of the structure as per designincludes; 20mm thick 150mm wide hard-wood section that acts as pelmate on all four sides |
| 52 | Assembly of Bamboo building-system on site as per design |
| 53 | Profile Sheets for top layer of the roof Profile Sheets for top-layer of the roof, Supply and Installation. (The roofing material can be Shingles, MP Terracotta roofing tiles or simple profile sheets depending on client preference. |
| 54 | Seating on Two sides of the Gazebo |
| 55 | Electrical Points 4 light points and 1 fan point and a switch board |