| 1 | BoQ for Committee Room ( Room-1) |
| 2 | 85 Inch Interactive Flat Panel with OPS |
| 3 | 43 Inch Display with floor mount stand |
| 4 | PTZ Camera with Ceiling Mount20X Optical Zoom, 60 fps |
| 5 | Ceiling Microphone ( tile 2x2 ) with Tile mounting kit and 90 Watt PoE++ Injector, 2 x 25 ft CAT6 cables |
| 6 | DSP Mixer with 12 Mic/Line AEC Inputs, 8 Mic/Line Outputs, USB Audio, VoIP, Telephone Interface (TP248) |
| 7 | CeilingSpeaker- 15 Watt |
| 8 | A/V controller with Touch Panel |
| 9 | 5KVA UPS with 30 Mins Backup |
| 10 | 04K 04-Port HDMI Switcher,4@60Hz AC powered , Black |
| 11 | 8 Port Switch |
| 12 | Wireless Access Point 802.11 AC |
| 13 | Wall Plate with HDMI IN etc. |
| 14 | 4K HDMI Cable 20M |
| 15 | 4K HDMI Cable 10 M |
| 16 | USB 3.0 Cable 10M |
| 17 | USB 3.0 Cable 20 M |
| 18 | Cat 6 Cable STP with Connectors (Mtr) |
| 19 | 15U Wall mount Rack |
| 20 | 1.5 Sq. mm Speaker Cable |
| 21 | One Time Installation, system Programming & Commissioning |
| 22 | Acoustic Treatment of the Room Acoustic Treatment of the Room (20X32 ) Wall, Door, Windows , ceiling etc ( detailed BoQ in Annex. Attached)Doors & Windowsa. Providing and fixing of roller blinds on existing glass windows area of required colour and shade and with all necessary fittings of approved make complete in all respect. -150 Sq. Ftb. Modifying of existing wooden doors as approved complete in all respect to achieve STC rating upto 40 to 55c. Single Door Size : 900L X 2100H- 03 NosWALL PANELLINGAcoustic Wall Paneling : PANNELLING WITH 50MM X 50MM WPC/PVC TUBES IN TIMBER SHADE OF APPROVED COLOUR- Providing and fixingfree standing WPC/PVC Timber Tubesplaced @ 50mm c/c verticlally/ horizantally,with top and bottom runner as per design , in approved shade and pattern as directed by the architet and fixed to the ceiling/ slab/ beam at he top and floor below at the bottom. The Timber tube should be made inwith WPC/PVC box section of size 50mmx50mm of Alstone/LEBEN / Alutuff / Murratoor other approved make of approved shade in approved pattern as directed by the site-in-charge/architect. Rates shall be inclusive of all hardware fittings sna fixtures as required to fix the same on the wall and ceilings including corner beading and fastners. Note- Measurement for this item shall be as the total length multiplied by the total widh(including spacing between two timber tubes as per design and as directed by the site-incharge. architect)- 700 Sq. Ft. |
| 23 | BoQ for Conference Room (Room-2) |
| 24 | 85 Inch Interactive Flat Panel with OPS |
| 25 | 43 Inch Display with floor mount stand |
| 26 | Podium with touch screen |
| 27 | PTZ Camera with Ceiling Mount20X Optical Zoom, 60 fps |
| 28 | Video Switcher |
| 29 | Boundary layered/Gooseneck Mic with controller |
| 30 | Ceiling Microphone ( tile 2x2 ) with Tile mounting kit and 90 Watt PoE++ Injector, 2 x 25 ft CAT6 cables |
| 31 | DSP Mixer with 12 Mic/Line AEC Inputs, 8 Mic/Line Outputs, USB Audio, VoIP, Telephone Interface (TP248) |
| 32 | Ceiling Mount Speaker- 15 Watt |
| 33 | Wall mount Speaker - 15 Watt |
| 34 | Amplifier 240 Watt |
| 35 | Wireless hand held mic |
| 36 | A/V controller with Touch Panel |
| 37 | 5KVA UPS with 30 Mins Backup |
| 38 | 04K 08-Port HDMI Switcher,4@60Hz AC powered , Black |
| 39 | Wireless Presentation gateway |
| 40 | 8 Port Switch |
| 41 | Wireless Access Point 802.11 AC |
| 42 | Wall Plate with HDMI IN etc. |
| 43 | 4K HDMI Cable 20M |
| 44 | 4K HDMI Cable 10 M |
| 45 | USB 3.0 Cable 10M |
| 46 | USB 3.0 Cable 20 M |
| 47 | Cat 6 Cable STP with Connectors (Mtr) |
| 48 | 24U Wall mount Rack |
| 49 | 1.5 Sq. mm Speaker Cable |
| 50 | One Time Installation, system Programming & Commissioning |
| 51 | Acoustic Treatment of the Room Acoustic Treatment of the Room (50X64 ) Wall, Door, Windows, ( detailed BoQ as per below)Doors & Windowsa. Providing and fixing of roller blinds on existing glass windows area of required colour and shade and with all necessary fittings of approved make complete in all respect. -1250 Sq. Ftb. Modifying of existing wooden doors as approved complete in all respect.i. Double Door Size : 1800L X 2100H - 02 Nosii. Single Door Size : 900L X 2100H- 02 NosWALL PANELLINGAcoustic Wall Paneling : PANNELLING WITH 50MM X 50MM WPC/PVC TUBES IN TIMBER SHADE OF APPROVED COLOUR- Providing and fixingfree standing WPC/PVC Timber Tubesplaced @ 50mm c/c verticlally/ horizantally,with top and bottom runner as per design , in approved shade and pattern as directed by the architet and fixed to the ceiling/ slab/ beam at he top and floor below at the bottom. The Timber tube should be made inwith WPC/PVC box section of size 50mmx50mm of Alstone/LEBEN / Alutuff / Murratoor other approved make of approved shade in approved pattern as directed by the site-in-charge/architect. Rates shall be inclusive of all hardware fittings sna fixtures as required to fix the same on the wall and ceilings including corner beading and fastners. Note- Measurement for this item shall be as the total length multiplied by the total widh(including spacing between two timber tubes as per design and as directed by the site-incharge. architect)- 800 Sq. Ft. |